Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹1.9 Cr+₹12.5 L (6.96%)Rejected-Finance | ₹1.9 Cr+₹12.5 L (6.96%) | L2 | Rejected-Finance BEING L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical REJECTED |
| 4 | Rejected-Technical | - | - | Rejected-Technical REJECTED |
| 5 | Rejected-Technical NOT SPECIFIED | - | - | Rejected-Technical REJECTED |
Tender Value
₹1.8 Cr
EMD Value
₹2.5 L
Closing Date
5 May 2022, 11:00 amClosed
CHIEF ENGINEER PROJECT CHETAK
HEAD QUARTERS CHIEF ENGINEER PROJECT CHETAK, BIKANER C/O 56 APO, PIN 931707
IMPROVEMENT OF SECURITY INFRASTRUCTURE OF GREF CENTRE AND RECORDS, PUNE 15 UNDER PROJECT CHETAK IN MAHARASHTRA STATE
2022_BRO_517553_1
CE (P) CTK/02/2022-23
Open Tender
Civil Works - Others
Item Rate
150 days
GREF CENTRE AND RECORDS PUNE UNDER PROJECT CHETAK
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹0
₹2.5 L
Yes
HQ CE PROJECT CHETAK, BIKANER
11 Jul 2022
11 Apr 2022
6 May 2022
11 Apr 2022
5 May 2022
11 Apr 2022
11 Apr 2022 - 13 Apr 2022
12 Apr 2022
Amount
ELECTRICAL WORK Civil Works
Excavation in trenches not exceeding 1.2 m width and 1.5 m depth in soil/soil mixed with Boulder (SMB), including dressing bottom and sides getting out and disposing all excavated material lead upto 6 m and lift upto 1.5 m. (by manual means) for laying of Cable, Erection of poles etc. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
- Ditto - all as per Item No 1.01 here in before but for extra depth of 1.50 m or Part thereof. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Earthwork in embankment including excavation of earth and filling with earth free from roots etc spreading in layres not exceeding 30 cm including watering rolling and finishing to required slope and level not exceeding 1.5 m high above the base in ordinary soil in plain area, rate considering credit for manual rough excavation in SMB for earthwork in embankment. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Disposal of excavated earth with vehicle upto 5 KM initial lead. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Plain cement concrete 1:4:8 (1 cement: 4 sand: 8 stone aggregate of size 4cm graded downwards) in foundation or elsewhere (excluding the cost of centering/shuttering). All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Plain cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 stone aggregate size 4cm graded downwards) in foundation or elsewhere (excluding the cost of centering/shuttering). All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Electrical Works
Supply & Laying in trenches clear sand/m-sand/puddled sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note: Punned thickness only measured and paid.
M/L for brick well burnt locally available superior quality sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Supply and laying of 40 mm dia GI tubing light grade with all fittings as cable protection for road crossing laid / fix in trenches/on wall. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Supply and laying of 50 mm dia GI tubing light grade with all fittings as cable protection for road crossing laid / fix in trenches/on wall. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Supply and laying of 80 mm dia GI tubing light grade with all fittings as cable protection for road crossing laid / fix in trenches/on wall. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Supply, installation and erection in vertical position of steel tubular swaged poles, type 410, SP-31(09 meters long ) with 300 mm x 300 mmx 6 mm mild steel base plate contineously welded to pole, MS steel plate of 3 mm thick finial taper plug bolt, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portiion in ground level and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surfaces including numbering as per standard size after erection complete all as specified. Zebra painting with black and white paint upto 1.5 mtr height from ground level and pole marking as directed as per given design and colour. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 16 Sqmm 4 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 25 sqmm 3.5 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 25 Sqmm 4 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 35 Sqmm 3.5 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 50 Sqmm 3.5 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 70 Sqmm 3.5 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract for following sizes :- Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 95 Sqmm 3.5 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 120 Sqmm 3.5 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supply, laying, jointing and testing of XLPE insulated,sheathed, armoured, heavy duty LT 1100 volts grade electric cable 185 Sqmm 3.5 core with aluminium conductor multistranded laid in trenches/pipes, fixed to poles/walls including provision of suitable size new aluminum cable lugs, cable glands in panels/ junction boxes, fixing GI saddles incl earh connection through cable armour by means of nut & bolts in poles complete.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract. Note :- The rate inclusive of supply and fixing HT / LT cable route indicator in every 30 mtr intervals along the cable trenches, made up of MS /CI engraved the descrption on the disc not less than 5/6" dia welded with 40 x 6 mm MS Srtip of approx length 75 cm duly painted on all steel parts as per colour code and provision of PCC 1 : 4 : 8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base buried under the ground incl necessary earth work complete
Supplying & fixing of street light fitting bracket made out of 40 mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers, complete. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
M & L for junction/connecting box made out of 2mm thick MS sheet / thermoplastic front openable, weather & vermin proof of size 300 x 250x 150 mm incl painting two coats of synthetic enamel paint over a coat of red oxide primer. Connection box shall be be suitable for housing & incl Aluminium Bus bar 200Amps cap- 04 Nos, MCB SP 6 Amp-01No and having provision of cable hole in bottom for two to three cables of size 35 Sqmm 4 core armoured cable connection box shall be fitted on street light pole and fixing arrangements complete. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
M& L for Earthing complete with GI earth plate 60x60cmx6mm thick electrode and 4 mm dia GI wire as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire 4 mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 and incl earth work, PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh, charcoal dust and salt etc and connected to earthing test point all as specified or directed and testing. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
M/L for Earthing complete with GI earth plate 60x60cmx6mm thick electrode and 32 x 6 mm dia GI strip as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI strip 32 x 6 mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 and incl earth work, PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh, charcoal dust and salt etc and connected to earthing test point all as specified or directed and testing . All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
M&L for Sub Main wiring using FR Insulated unsheathed, multistrand copper conductor FR PVC cable 2 runs of size 2.5 sqmm for phase and neutral and 1.5 Sq mm for earthing. drawn through and including rigid PVC conduit of suitable size with fixing clamps on pole for connection from junction box to light fittings complete all as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Supply and fix in repairs cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces complete all as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 440 V three phase of 20 Amp rating with contactor, relays, tripping arrangement for overload protection, suitable capacity breakers, LED indicating lamps, busbars, connecting terminals, mounting insulators, 24 hours time setting relays with voltage/ current indication manual/ auto control switches, cable glands etc. complete. Fitted inside steel enclosure made up of 2 mm thick CRCA Sheet powder coated box having suitable cable entry & exists including necessary fixing clamps complete all as specified and as directed. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, with dirver, SPD complete. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
S & F MCCB 4 Pole, current rating 500/630 Amp, adjustable over load and short circuit with Micro processor release setting , breaking capacity 36 kA at 415V, 50Hz, of (Make : L & T Cat No CM93007OOOOX1 or equivalent in Legrand / Schenedier) incl necessary spreaders / cable lugs / nut, bolt and washers if required all as direcetd.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Ditto all as per item No 2.24 here in before but 4 pole 315/400 A, having breaking capacity 36 kA (Make : L & T Cat No CM93003OOOOX1 or equivalent in Legrand / Schenedier).All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Ditto all as per item No 2.24 here in before but 4 pole 200/250 A, having breaking capacity 36 kA (Make : L & T Cat No CM92151OOOOX1 or equivalent in Legrand / Schenedier) .All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Ditto all as per item No 2.24 here in before but 4 pole 100 to 160 A, having breaking capacity 36 kA, (Make : L & T Cat No CM92153OOOOX1 or equivalent .All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Ditto all as per item No 2.24 here in before but 4 pole 32 to 63 A, having breaking capacity 36 kA, (Make : L & T Cat No CM92155OOOOX1 / CM92154OOOOX1 or equivalent in Legrand / Scheneider).All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
S & F MCB TPN 32 amps 415 volts C series (Make L & T Cat No BB30630C or equivalent) all as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
S & F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 120 Sqmm.All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Taking down / dismantling old UNSV ACSR conducter of any size from pole complete. .All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Taking down / dismantling old UNSV LT insulator of any size from pole complete. .All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Taking down/dismantling old UNSV steel poles/struts any size of any size complete..All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
Taking down/dismantling old UNSV MS Cross arms /steel work from pole complete. .All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
S & F LT MCCB enclosure, outdoor type, mounted on rigid angle iron frame, overall size not less than 400 x 400 x 250 mm, cubical type, padestal mounted, having independent compartment, dust and vermin proof & lockable, factory made, fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply complete, Incoming:- (a) Indicator Lamps (LED type) showing R,Y, B phase (b) Provision for MCCB 4 Pole, 63Amp 415V - 01 No. All as specified in special conditions and particular specifications and as directed by Engineer-in-Charge/ OC Contract.
impex traders contracts
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .