| 1 | L1₹10.5 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ok | |
| 2 | L2₹14.9 L+₹4.4 L (41.8%)Rejected-AOC 2 2407 GILL COLONY NARAINPURI SAHARANPUR UP | SAHARANPUR | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-AOC ok | |
| 3 | L3₹15.0 L+₹4.5 L (42.6%)Rejected-AOC 36A 60 CIVIL LINE TELIYAR GANJ ALLAHABAD UTTAR PRADESH 211004 | PRAYAGRAJ | UTTAR PRADESH | 211004 | L3 | Rejected-AOC ok | |
| 4 | L4₹15.6 L+₹5.1 L (48.2%)Rejected-AOC | L4 | Rejected-AOC ok |
Tender Value
₹15.3 L
EMD Value
₹30,700
Closing Date
7 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Dehradun
HQ CWE Dehradun
SPL REPAIR TO UPS FOR MH AND PROVN OF CERTAIN MINOR WORK UNDER GE DEHRADUN
2023_MES_627624_1
9850/DDN/E8
Open Tender
Civil Works
Item Rate
120 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹30,700
Yes
17 Jan 2024
9 Nov 2023
9 Dec 2023
9 Nov 2023
7 Dec 2023
23 Nov 2023
Amount
Supply and fix UPS for 30 min back up three phase 40 KVA with suitable numbers of SMF batteries of size 12V/100 AH of following specifications with full responsibility to service of UPS System and keep in proper fully operation for at least period of 3 years by OEM :- Note: Old unserviceable UPS will be deposited in MES store yard. (a) Input voltage range :- 340V-460V AC Three phase. (b) Input frequency ;- 45-55 Hzs. (c) Output Voltage :- 415 Volt +/- 1% AC Three Phase. (d) Output Frequency :- 50Hz +/- 1%. (e) Power factor :- 0.95 to unity. (f) Operating Temp :- 0 to 45 deg C (g) Humidity :- working upto 95%. (h) Isolation :- Isolation between input and output through isolation transformer.
(j) Protection :- Input MCCB Battery MCCB/MCB Battery Charging current limit. DC under voltage/over voltage. Incoming/outgoing single phasing. Output over load. Output short circuit.
(k) LED indication :- Input RYB Output RYB Rectifier on Rectifier trip Boost charging Inverter on Batery Over load Low Battery DC Over voltage
(l) LCD Display :- Input voltage between RY-YB-BR Output voltage between RY-YB-BR Battery voltage in percentage *%) Output frequency Output load in percentage (%) Battery Charging Current. Battery low. Overload
(h) Bypass mode :- Manual (automatic-optional) (j) Alarm/Protection :- All types of alarms and protection should be provided. (k) Nature of Cooling :- Natural Air Cooled. (l) Efficiency :- >95 to 98 %
Supply and fix Servo Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 40 KVA with the following specifications and full responsibility to service of voltage stabilizer and keep in proper fully operation for at least period of 3 years by OEM :- :-
(a) Input voltage range :- 300V-480V AC Three phase. (b) Input frequency ;- 45-55 Hzs. (c) Output Voltage :- 415 Volt +/- 1% AC Three Phase. (d) Control Type :- Digital-Micro Controller based. (e) Reset :- Manual/Auto Reset with time delay and programmable. (f) Protections:- (i) Electronic overload protection and short circuit protection through MCB and the manual by pass is built in. (ii) Phase reversal protection and cut off. (iii) Single phase protection and cut off. (iv) Neutral failure protection. (v) Frequency cut off protection. (vi) Earth Neutral cut off protection.
(g) Metering Digital type with the followings with class 1 Accuracy with full scale (+/-1). (i) Input : - (aa) Phase to Neutral. (ab) Input Phase to Phase. (ii) Output : - (aa) Phase to Neutral. (ab) Input Phase to Phase. (iii) Load Current in all phases. (iv) Frequency. (h) Audio Alarm for tripping condition. (j) Nature of Cooling :- Natural Air Cooled. (k) Efficiency :- >95 to 98 % (l) Operating temperature :- 0-45 deg C. (m) Operating Humidity :- Up to 95 %.
Supply and fix off load change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed.
S &F PVC insulated, armoured, heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed.
M&L for sub main wiring with 4 x Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium duty PVC concealed conduit/flexible conduit where required and conduit accessories and fittings. Including 2 x single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 10 Sqmm as earth wire up to common earth and connected to earth dolly complete including taking out old unserviceable submain wiring complete all as specified and directed.
S&F surface point wiring for one light point/5 Amp socket out let (Independent point) controlled by one, one way switch, with 1.5 Sqmm size PVC insulated unsheathed 1100 volt grad single core stranded (multi strand) copper conductor cable (FRLS) drawn into and incl PVC conduct medium grade (not less than 20mm dia) with including it all necessary fittings and accessories or drawn into SUNK cast iron or pressed steel terminal boxes for mounting fitting like switches, sockets, lamp holders, sketches fittings and covered with 3mm thick plastic laminated sheet cover fixed with brass screw and cup washer including on continuous run of PVC insulated green colour) 1.5 sqmm size solid copper conductor cable as in earth wire and connected to earth dolly complete as specified and directed for surface conduit wiring on stone/brick walls.
M&L for switch piano flush button SP one-way 5 Amp complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x 25 mm two to three terminals complete all as specified and directed.
Supply, Fixing & Connecting wall mounted fan oscillating type 400 mm sweep single phase 230 Volt complete all as specified and directed.
S&F MCB SPN 240 Volt 6 to 30 amp rupturing capacity 10 KAB series complete all as specified and directed.
Supply and fix reversible type air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR with 3-star rating along with 05 KVA single phase voltage stabiliser complete all as specified and directed.
M&L sub main wiring with Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 2X 4 SQMM (nominal area) PVC conduit on wall and floor complete all as specified and directed.
S & F single pole and neutral enclosure with a two pin and earth plug with socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F sheet metal enclosures 240-volt 4 way with suitable rated bus bar for double door IP-43DB’s complete all as specified and directed.
S&F MCB single pole 240 volt 10 KA 5 to 40 Amp, conforming to relevant IS complete all as specified & directed.
S&F MCB SPN 240 Volt 10 KA 40 Amp conforming to IS complete all as specified & directed.
RAMAPATI ENGINEERING SERVICES
PRAGATI ENTERPRISES
WAVESHAPES INDIA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .