GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARALI
REPAIR AINTENANCE OF TRANSFORMER,VCB, DO FUSE, PANEL BOARD AND ALLIED WORKS OF HT NETWORK AT SAA, COLD STORAGE, PACKAGE PLANT WITH ALLIED WORKS AND EXTERNAL ELECTRIC SUPPLY, OVERHEAD LINE, UG CABLE AND ALLIED WORKS AT ZONE 2 AND ZONE 4 E GE (S) TE
2021_MES_483447_1
8619
Open Tender
Civil Works
Item Rate
240 days
GE SOUTH TEZPUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOUTH TEZPUR
₹99,800
Yes
15 Dec 2021
23 Oct 2021
22 Nov 2021
23 Oct 2021
20 Nov 2021
4 Nov 2021
Amount
Excavation in trenches n.exc 1.5m wide and n.exc and 1.5 mtr in depth getting out in in soft/loose soil all as specified and directed.
All as per item No. 1 above but exceeding 1.5 mtr and not exceeding 3 mtr in depth.
Returning and filling including spreading, levelling, watering and well ramming in layer n.exc 25 CM thick in soft/loose soil all as specified and directed.
Removing excavated material to a distance not exc. 50 mtrs and depositing where directed at a level not exceeding 1.50mm above the starting point all as specified and directed.
Supply and laying natural river sand as cushioning of cables, including spreading and punning down all as per clause No 3.21 of SSR part -I complete all as specified and directed by Engineer-in-charge and directed by Engineer in charge Note : punned thickness will only be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover, but class HV, Type 1, flat, size 300mmx 180mm x 40mm complete all as specified and directed.
Supply, Laying ,testing, and commissioning size 3x120 sqmm cross-sectional area XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric cable with aluminium conductor 11000 volts grade, in tranches / fixing on wall by saddle/ fixing on poll / drawn through GI pipes including taking down Old unsv UG cable complete all as specified and directed. Make- Havells / Polycab/ Gloster
Supply, Laying ,testing, and commissioning size 3x95 sqmm cross-sectional area XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric cable with aluminium conductor 11000 volts grade, in tranches / fixing on wall by saddle/ fixing on poll / drawn through GI pipes including taking down Old unsv UG cable complete all as specified and directed. Make- Havells / Polycab/ Gloster
Supply, Laying ,testing, and commissioning size 3x95 sqmm cross-sectional area Aerial Bunch Cable with H4 grade Aluminium, with extruded semi conductor screen, XLPE insulation, Insulation screen Non-metallic extruded semi conducting layer, insulation screen metallic applied helically over the non metallic layer, sheath PVC type ST2, with messenger conductor of one run of ACSR of nominal dia 55 sqmm , heavy duty 11000 volts grade, fixing on poles including all its hardware accessories such as suspension hook, insulator, suspension clamp, rubber insert etc including taking down Old unsv ABC cable complete all as specified and directed. Make- Havells / Polycab/ Gloster
Dismantling of Steel tubular poles / struts any size complete.
M & L in repair Steel tubular swaged poles complete with cast iron base plate, finial tapr plug, bolts, nuts and screws as specified type 410 SP-55, 11 metres long complete all as specified and directed.
M & L angle iron Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M&L for cement concrete type D2, 1:4:8 (using 40 mm graded sto agg.) in foundations, filling and mass concrete complete all as specified.
M&L for cement concrete type C1 1:3:6 (20mm graded aggregate) in or mud stops, rounded or chamfered on edges etc all as specified and directed
M&L for cement concrete type B0, 1:2:4 (using 12.5 mm graded sto agg.) for coping above ground level of steel electric pole concrete complete all as specified.
M & L for Broken Stone or Boulders Hardcore of Gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rammed to a True Surface, complete all as specified and directed.
S & F in repair composite polymer type pin insulator for 11 KV overhead line including all its accessories complete all as specified.
M & L in repair composite polymer Disc type insulator, ball and socket type with tension clamps and all hardware components for conductors, working pressure for 11000 volts complete all as specified and directed.
S & F in repair composite polymer type post insulator for 11 KV overhead line including all its accessories complete all as specified.
S & F in repair composite polymer type pin insulator for 33 KV overhead line including all its accessories complete all as specified.
M & L in repair composite polymer Disc type insulator, ball and socket type with tension clamps and all hardware components for conductors, working pressure fit for 33KV complete all as specified and directed.
M & L Composite Polymer Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11 KV (station class/distribution class) to fix it on the Pole with continuity conductor up to earth terminal including taking down unsv LA complete all as specified and directed. Make- Lamco/ jaipuria/ Bhel
M & L Composite Polymer Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 33 KV (station class) to fix it on the Pole with continuity conductor up to earth terminal including taking down unsv LA complete all as specified and directed. Make- Lamco/ jaipuria/ Bhel
M & L Composite Polymer Air Break switch gang operated Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps fit for 11 KV with all accessories including taking down unsv GOD Complete all as specified and directed. Make- Rashtriya / jaipuria/ Bhel
M & L Composite Polymer Air Break switch gang operated Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps fit for 33 KV with all accessories including taking down unsv GOD Complete all as specified and directed. Make- Rashtriya / jaipuria/ Bhel
S & F in repair Male Contact/ moving contact blade of Air Break Switch 11 Kv complete all as specified and directed. Make- Rashtriya / jaipuria/ Bhel
S & F in repair Female contact/ fixed contact Jaw of Air Break Switch 11 Kv complete all as specified and directed. Make- Rashtriya / jaipuria/ Bhel
S & F in repair MS jumper Carrier of Air Break Switch 11 Kv complete all as specified and directed. Make- Rashtriya / jaipuria/ Bhel
S & F in repair Back contactor Plate of Air Break Switch 11 Kv complete all as specified and directed. Make- Rashtriya / jaipuria/ Bhel
M & L Composite Polymer Expulsion type Drop Out fuse single pole 11 KV , above 50 Amps up to 100 Amps including MS channel for fixing it with the pole including taking down old unsv DO fuse complete all as specified and directed. Make- Rashtriya / jaipuria/ Bhel
Material and labour for painting of steel tubular pole 11 mtr long, including cross arms bracing supports etc complete by applying two coat of synthetic enamelled paint (colour will be chose by EIC) after surface preparation, marking of pole numbers and making 3 Nos of black colour strip 30 cm wide on equal distance from coping complete all as specified and as directed by Engr - in Charge.
Supply & Fix synthetic mat of size 2m x 1m x 3 mm including taking out old Unserviceable Synthetic mat all as specified and directed.
Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for 20x15cm size complete all as specified and directed.
Supply and fix Cable jointing kit for 11KV grade cable for Outdoor End termination heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 120 to 185 sq mm all as specified including Disconnecting and cutting down the existing old unserviceable / worn out cable end joint Kit 11 KV grade indoor termination cold shrink type as directed by Engineer-in-charge. make- 3M/DENSON/Raychem
All As per Item No - 35, but for 50 to 95 Sqmm
All as per Item No-35 , but for outdoor End Termination Aerial Bunch Cable of 50-95Sqmm
Supply and fix Cable jointing kit for 11KV grade cable for Outdoor Straight through joint, Heat shrink type complete with Jointing material and acceesseries suitable for 3 core are XLPE armoured at conductor cable of size 50 to 95sq mm all as specified as directed by Engineer-in-charge. make- 3M/DENSON/Raychem
All As per Item No - 38, but for 120 to 180 Sqmm
All as Per Item No-38, but for outdoor Straight through Joint of Aerial Bunch Cable
Disconnecting all in coming and outgoing cables, removing the transformer of capacity 100-150 KVA from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to the contractor's workshop, carry out the required repairs and transport the transformer back to the site , install it, reconnect all the incoming and out going cables by properly crimping using lugs of suitable size lugs, taping the LT / HT bushes / bus bars, using LT / HT insulation tape and testing complete of following capacity all as directed by Engr-in-Charge Note :- (a) Shifting and fixing transformer from own arrangement temporarily from MES Area to that area ( Back up Transformer will be provided by MES) (b) The cost of transportation of 2 transformers between Existing location and the Workshop is deemed to be included in the unit price. (b) Gasket set, LT/HT side porcelain / ceramic bushing, spindle for HT/LT side , rewinding, dehydration of oil (if required) shall be measured and paid separately in respective items.
All as per Item No- 41, but for capacity 200-315 KVA capacity
All as per Item No- 41, but for capacity 400-500 KVA capacity
S & F brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of of capacity 100-150 KVA
All as per Item No-44, but for capacity 200-315 KVA capacity
All as per Item No- 44, but for capacity 400-500 KVA capacity
All as per Item No- 44, but for LT Side & capacity 100-150 KVA capacity
All as per Item No- 44, but for LT Side & capacity 200-315 KVA capacity
All as per Item No- 44 , but for LT Side & capacity 400-500 KVA capacity
Labour for filtration of transformer oil of Capacity 100 KVA to 2.5 MVA with ultra high vacuum filtration machine and checking dielectric strength (BDV), dielectric dissipation factor, neutralizing value (total activity) 55-60 KV with 2.5 mm Gap sludge content, flush point of transformer oil from Standard Testing Laboratory all as specified .Refilling the transformer oil in the shell of transformer after carrying out filtration and heating up oil to achieve reqd dielectric strength and submitting the test result before and after filtration of oil in presence of Engr- in- charge on proper proforma duly signed.
Supply and fill Transformer oil with high viscosity , high resistance to oxidation & thermal stability maintaining BDV Value of 55-60 KV in 2.5mm rod gap complete all as specified and directed. MAKE-CASTROL/INDIAN OIL/HPCL
S & F dehydrating breather for 100-150 KVA transformer with dehydrating agent (Silica gel) including taking down existing breather complete all as specified.
All as per Item No- 52 , but for 200-315 KVA transformer
All as per Item No- 52, but for 400-500 KVA transformer
Supply and fix ceramic bushing on HT side of transformer of capacity 100-150 KVA (Make : Mysore Potteries/BHEL/ :-
All as per Item No- 55, but for 200-315 KVA transformer
All as per Item No- 55, but for 400-500 KVA transformer
All as per Item No- 55, but for LT side of 100-150 KVA transformer
All as per Item No- 55, but for LT side 200-315 KVA transformer
All as per Item No- 55, but for LT side 400-500 KVA transformer
Supply and fixing in replacement of complete gasket (Cock sheet) 6 mm thick complete of capacity of following transformer including conical rubber bush for Transformer of capacity 100-150 KVA
All as per Item No- 61, but for 200-315 KVA transformer
All as per Item No- 61, but for 400-500 KVA transformer
Material and labour for painting to 100-150 KVA transformer scrapping and removing oil paint and applying 01 coats of synthetic enamel paint by taking due care for HT/LT side supply all as specified and directed by Engineer-in-charge .
All as per Item No- 64, but for 200-315 KVA Transformer
All as per Item No- 64, but for 400-500 KVA Transformer
Supply and winding of 11/0.433 KV HV coils, using new copper wire/strip of proper size including insulating materials (double insulation)as per existing size of core of transformer complete including heating , varnishing complete all as specified and directed
Supply and winding of 11/0.433 KV LV coils, using new copper wire/strip of proper size including insulating materials (double insulation)as per existing size of core of transformer complete incl heating , varnishing complete all as specified and directed
M & L for winding of 11/0.433 KV HV/LV coils coils, removing U/S insulating materials, double reinsulation with insulating papers using same copper strip and rewinding as per existing size of core of transformer complete incl heating , varnishing complete all as specified and directed
Calibration and testing of combined inverse time over current and intstantaneous relay, checking and cleaning / decarbonising its moving and fixed contacts and ensure physical healthiness with visual check for healthy tripping of over current and earth fault, adjusting tripping time, flag setting, ratio setting, instantaneous time setting etc as per installed capacity of transformer to be saved on maximum, short circuit current in accordance with percentage impedance of transformer with artificial current injection on primary side with current injection machine of HT VCB,s complete all as specified and directed Note : Spares / meters shall be measured and paid separately.
Overhauling/Repair of 33 KV VCB with panel, rated voltage- 36 KV cleaning of all parts, adjusting contacts, springs locking arrangements tripping coil circuits (closed/open) etc cleaning of CT and PT supporting insulators bush trolley auxiliary contact. Make female contact and check all wiring including minor item required for repair complete all as specified and directed
Overhauling/Repair of 11 KV VCB with panel, rated voltage- 36 KV cleaning of all parts, adjusting contacts, springs locking arrangements tripping coil circuits (closed/open) etc cleaning of CT and PT supporting insulators bush trolley auxiliary contact. Make female contact and check all wiring including minor item required for repair complete all as specified and directed
Overhauling/Repair of Float cum Boost Charger, cleaning of all parts, check all wiring , Checking Output Voltage, Checking entire DC Circuit from Charger to the panel Fuse including replacement of minor item required for repair complete all as specified and directed by Engr in Charge
S & F in repair 3 phase digital type Amp meter 0 - 200 Amps class 0.5 of size 96mm x 96mm to match the ratio of existing CTs
S & F in repair 3 phase digital type Volt meter 0 - 11 KV class 0.5 of size 96mm x 96mm to match the ratio of existing PTs.
S & F in repair 3 phase digital type Volt meter 0 - 33 KV class 0.5 of size 96mm x 96mm to match the ratio of existing PTs
S & F in repair Programmable numerical inverse time over current / earth fault relay suitable for VCB 11/12 KV of make ABB Model No - REJ-601 or Equiv of Kirloskar / Areva complete
S & F in repair Epoxy Resin Body for switchgear VMX type 11 KV VCB, 630 Amp Complete all as specified and directed. Make- Areva or Equivalent
S & F Top clamps with hardware (pair) R/B phase 630 / 800 Amps complete all as specified and directed.
S & F Top clamps with hardware (pair) Y phase 630 / 800 Amps complete all as specified and directed.
S & F in repair Half collar (Pair) of VCB 630 Amps complete all as specified and directed
S & F in repair Brass nut of VCB 630 Amps complete all as specified and directed
S & F in repair Spider for VCB 630 Amp Complete all as specified and directed
S & F in repair Epoxy Resin Spout bushings triple pole assembly fit for 11 KV VCB panel Complete all as specified and directed
S & F in repair Gromet VCB 630 Amp Complete all as specified and directed
S & F in repair Drive insulator with M10 Nylon Nut for VCB 630 Amp Complete all as specified and directed
S & F in repair Drive Beam (Pair) VCB 630 Amp Complete all as specified and directed
S & F in repair closing coil assembly 110 volt for VCB complete all as specified and directed
S & F in repair tripping coil assembly 110 Volt for VCB complete all as specified and directed
S & F in repair TNC switch , 110 Volt complete all as specified and directed
S & F in repair vacuum interrupter suitable for VCB VMX type 630/400A Model. VG2 BW524/99/Ro Make -Areva.
S & F in Bakelite HRC fuse base with carrier 32A, 415 V with HRC fuse 5 amps complete all as specified and directed.
S & F in repair Buffer for VCB 11KV complete all as specified and directed.
S & F in repair push button actuator 1 No element, 22.5 mm dia (TCH) assembly
Material and labour for cradles hexagonal / rectangular fabricated with galvanised steel wire 3.15 or 4 mm dia complete all as specified and directed
Stringing / restringing only existing cradles hexagonal / rectangular, GI earthing wire of any shape and size complete all as specified and directed. Note- 1. Span Between two consecutive poles shall be measured as one unit.
Labour for checking & rectifying High Tension (11KV/33KV) fault location by disconnecting Jumper, Climbing the pole, checking of insulators etc at any location, any time round the clock in SAA complete all as specified and directed. Note:- 1. The cost of materials used shall be measured and paid separately 2. The labourers shall be available round the clock of 24 hours a day. 3. The cost of use of tools and safety equipments is deemed to be included in the unit rate.
Supply, fixing / stringing Aluminium conductor steel reinforced of any type and size on existing steel tubular / PCC poles including winding, jumpering with alkathine pipe etc complete all as specified and as directed.
S & F in Repair WTI (Winding temperature indicator) fit for 33/11 KV, 2.5MVA Transformer complete with all its accessories all as specified and directed.
S & F in Repair OTI (Oil temperature indicator) fit for 33/11 KV, 2.5MVA Transformer complete with all its accessories all as specified and directed.
Labour for restringing/tilting, clamping, bending, jumpering etc to remove excess sag of loose ACSR overhead line using essential T&P such as manila rope, puller and teipod etc upto permissible sag between two poles continuously upto termination point. Note- 1. Three runs of ACSR shall be measured as one unit. 2. Span Between two consecutive poles shall be measured as one unit. 3. The cost of use of required tools and safety equipments is deemed to be included in this unit price.
Labour for trimming/cutting to small tree branches girth not exc 30cm upto minimum 2 Mtr clearance, tightening to stay stand in proper angle complete all as specified and directed by Engr in charge. Note- 1. Span Between two consecutive poles shall be measured as one unit. 2. The cost of use of required tools and safety equipments is deemed to be included in this unit price.
Supply and fixing in replacement to old by new Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size all as specified and directed. Note :- Instruction shall be written in three language Hindi, English and Assami on notice board.
Labour to re-stringing/ tilting, clamping, bending , jumpering, etc to be removing excess sag of loose ACSR of over head line upto permissible sag at camp area using accessories, T&P such as manila rope, puller and tripod etc upto permissible sag between two poles to continuously upto terminating point of tightening of stay strand in proper angle etc all as per site requirement and directed Note :- (i) Three/ four/six/eight runs of ACSR shall be measured against one unit. (ii) Quoted rates shall be included for all required T&P and safety equipment. (iii) Span Between two consecutive poles shall be measured as one unit.
Supply and fixing in replacement to old by new Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as specified and directed. Note :- Instruction shall be written in three language Hindi, English and Assami on notice board.
M&L in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed .
Supply and fixing in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for working pressure 1100 volts grade complete all as specified and directed .
Supply and fixing in replacement of Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, suitable for 1100 Volts, Height 100 mm, Width 115 mm including galvanised strap 31 x 5 mm, Nut bolts 14 mm and Washer 3 mm thick as under: complete all as specified and directed.
Supply and fixing in replacement of Loop type insulator, vitreous porcelain, white, brown or green, Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed.
M&L for in replacement of Stay assembly 16 mm dia stay rod complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) complete all as specified and directed . Note : Loop type insulator, excavation, earth work and concrete to be measured and paid against the respective item.
M & L in replacement Steel tubular swaged poles complete with cast iron base plate, finial tapr plug, bolts, nuts and screws as specified type 410 SP-31, 9 metres long complete all as specified and directed.
M&L for in replacement of Galvanised stay strand (Grade 2), size 7/4.0 mm mm complete all as specified and directed.
M&L for in replacement of Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4mm dia all as site required all as directed.
Labour for re-fixing/ titing/ bending /cradles, hexagonal/ rectangular, fabricated net in proper gap etc all as site to old galvanised wire in any size as safe guard of HT/LT over head line with fixing as directed. Note - The span between two poles is deemed to be considered as one unit.
Re-fixing only with tilting/ jointing/ bending/ jumpering etc all as site to aluminium conductor steel reinforced (ACSR) in any size/ dai/ type etc on existing poles using puller/ rope/ tripod etc to re-stretching in serviceable sag all as directed.
Supply and fixing in replacement of Aluminium conductor, steel reinforced complete all as specified and directed .
Supply and fixing in replacement of House service bracket (hook type complete with 3.0m long G.I. pipe 50 mm dia Med. grade, two nose 90 degree bends. M.S. hook and stay or guy complete all as site and directed..
Supply and fixing in replacement of the following cable end/ straight termination jointing kit ,1100 volt grade (earthed) , 3.5 core 400 sqmm aluminium conductor XLPE insulated armoured heavy duty cable heat shrinkable suitable in/ out door type to be fix on incoming /outgoing connection of LT panel with gland etc at various location for following size :-. Make - Dension / Raychem / 3M
All as in Item No - 120, but for 3.5 core 185 to 300 Sqmm
All as in Item No - 120, but for 3.5 core 90 to 150 sqmm
All as in Item No - 120, but for 3.5/4 core 25 to 70 Sqmm
All as in Item No - 120, but for 3.5/4 core upto 16 sqmm
Supply and laying or fixing or passing through pipe in replacement of , 1100 volts grade heavy duty cable with PVC insulated Stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as directed. Make - Finolex /Havells/Polycab or equivalent
All as in Item No- 125, but for 2core 10 sqmm
All as in Item No- 125, but for 2 core 16 sqmm
Supply and fix MCCB 4 pole, microprocessor based Release range 100 Amps to 250 Amps,415V,AC,50Hz ,36 KA Manual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down MCCB all as specified and directed by Engineer-in-charged Make - Seimens/L&T/Schneider/ABB
All as in Item No- 128, But for MCCB 160 Amps to 400 Amps.
Supply and fix MCCB 4 pole, thermal magnetic based Release range 63 Amps to 100 Amps,415V,AC,50Hz ,36 KA Manual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.8 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down MCCB all as specified and directed by Engineer-in-charged Make - L&T/Schneider/ABB
Supply and fixing in replacement of MCBs , 240 Volts grade , DP ,"B" curve , 63 Amps complete all as specified and directed by Engr-in-charge. Make :- legrand/ Seimens / Schneider
Supply and fixing in replacement of MCBs , 240 Volts grade , DP ,"B" curve , 40 Amps complete all as specified and directed by Engr-in-charge. Make :- legrand/ Seimens / Schneider
Supply and fixing in replacement of MCBs , 240 Volts grade , SP, single pole ,"C" curve , 6 to 32 Amps complete all as specified and directed by Engr-in-charge. Make :- legrand/ Seimens / Schneider
Supply, fixing and connecting in replacement of Manual On Load change over switch with sheet steel enclosure rating 200 Amps 4 pole, 440 volts grade in sheet metal enclosure conforming to IEC 60947-3, IS/IEC 60947 -3 fixing in panel/ surface of wall on wooden board with making all connection, gland etc all as site and directed. Make - L&T or equivalent in Siemens/ Phillips/ Havells/ ABB
Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armoured heavy duty electric power cable with aluminium conductor , 1100 volts grade (earthed) cross section area 240 Sqmm x 3.5 core. Make - Finolex/ Havells/Gloster/Polycab
All as in Item No-135, but for 185 Sqmm x 3.5 core
All as in Item No-135, but for 95 Sqmm x 3.5 core
All as in Item No-135, but for 70 Sqmm x 3.5 core
All as in Item No-135, but for 50 Sqmm x 3.5 core
All as in Item No-135, but for 25 Sqmm x 4 core
All as in Item No-135, but for 16 Sqmm x 4 core
All as in Item No-135, but for 10 Sqmm x 4 core
Labour for horizontal boring of Road/path for cable passing through complete all as specified
S & F in replacement cable route indicator for LT UG cable of 1100 Volt grade bolted with 40 x 6 mm flat iron member of height 1 Mtr duly painted , embedded, in PCC 1:3:6 type C2 of size 20 x 20 x 30 cm block complete all as specified and directed
Supply/ laid/ fixing in replacement of galvanised steel water tube, light grade bore of dia 80 mm with all fittings all as site and directed. Make - Tata / Jindal
Supply/ laid/ fixing in replacement of galvanised steel water tube, light grade bore of dia 50 mm with all fittings all as site and directed. Make - Tata / Jindal
M&L for jointing/ cutting/ welding/ replacing hinges etc all as site required to LT panel made out MS sheet and angle for making smooth opening and closing complete with re-painting as same matching with existing surface all as directed.
M&L for painting to electric pole steel tubular/ PCC after removing /scraping/ bruses/ cleaning to old paint on external surface in two coats of paint over one coats of red oxide primer by using synthetic enamel aluminium paint on steel tubular and cement paint on PCC poles in any height/ length/ dia etc including cross arms/ angles, nut, bolt , washers etc and making alternate strips of yellow and black paint in 30 cm minimum width upto 1.5 Mtr above normal GL and writing Pole No complete all as site and directed by Engr-in-Charge. Note : Colour of paint shall be approved by Engr-in-charge.
All as in Item No- 148, but for two pole structure including all angle iron elements
All as in Item No148, but for three pole structure including all angle iron elements
All as in Item No- 148, but for four pole structure including all angle iron elements
Decarbonising/ cleaning of Existing LT panel cubical type of various size consists of bus bar and circuit chamber, metering chambers CTs and relays chambers, checking the bus bar joints, bus bar and circuit spouts, cleaning and applying Busbar Insulation Tape to the bus bars , checking the current transformer, applying Monopolist compound at the bus bar joints after tightening of joints ,replaced new suitable size of lugs /suitable copper control cable and reassembling , if any rusted sheet replaced with new sheet as per existing size complete all as directed by Engineer-in-Charge. Note:- Cost of lubricant/ cleaning agents (CRC & rust remover) / hardware like springs/ bolts/ nuts/ washers, lugs/ suitable copper cables cost of labour, T&P required for replacement shall be etc. shall be deemed to be included in the rate quoted.
Material and labour for painting to LT panel of any size by scrapping and removing oil paint and applying 01 coats of synthetic enamel paint of approved colour by taking due complete all as specified and directed by Engineer-in-charge .
Material and labour for painting to 100-400 KVA transformer by scrapping and removing oil paint and applying 01 coats of synthetic enamel paint of approved colour by taking due care for HT/LT side supply all as specified and directed by Engineer-in-charge .
M & L for spreading crushed coarse stones aggregate upto 40mm grade suitable for substation yard complete all as specified and directed.
S & F LED indicating Lamps for R, Y, B phases complete including taking down old U/S lamps all as specified and directed.
M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.5 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge. Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate.
Supply and fixing in replacement of Test point terminal block made of gun metal or phosphorus bronze in size 75x75x25 mm drilled and screwed including 03 nos ,8 mm dai 25 mm long hex head screw complete all as specified and directed.
S & F LT in replacement overhead PVC line spacers as per the existing site requirement complete all as specified and directed.
Supply and fixing in repair compressor sealed type suitable for 3 phase split type AC 5 ton capacity including making necessary connection complete all as directed..
Supply and fixing sub zero compressor controller for two compressor including connection and wiring at specified location and testing complete all as specified and directed.
Supply and fixing in repair temperature gauge for both cold room and cool room in showing centigrade and Fahrenheit complete all as specified and directed.
Supply and fixing in repair blower fan motor (outdoor unit) for 5 ton compressor complete all as directed.
Supply and fixing in repair blower fan blade (outdoor unit) for 5 ton compressor complete all as directed.
Supply and fixing in repair three pole contactor suitable for 3 phase split type AC 5 Ton capacity including making necessary connection complete all as directed.
Supply and fixing in repair drier of 5/8 inch type for cold storage plant complete all as directed.
Supply and fixing in repair HP switch for 5 ton compressor for cold storage plant complete all as directed.
Supply and fixing in repair LP switch for 5 ton compressor for cold storage plant complete all as directed.
Supply and fixing in repair nitrile insulation 7/8' (11x5 mtr) for insulating refrigerant flow copper tube complete all as directed.
Supply and charging of refrigerant gas R-134A for cold storage plant complete all as directed.
M&L for carrying out pressure test Quarterly of the entire system connection to open type /sealed compressor unit and checking for leakage with filling nitrogen gas to required pressure rectify leakage and again testing to the entire satisfaction of GE complete all as directed.
Supply and fix in repair of rubber mounting pad for package AC outdoor unit as directed.
Supply and fix in repair of four core cable copper conductor PVC insulated multistranded sheathed 1100 Volt grade 2.5 sqmm complete all as specified & directed.
Supply and fixing in repair MCBs , 440 Volts grade , TP, triple pole ,"C" curve , 32 Amps 25 KA breaking capacity complete all as specified and directed.
M&L Subclass B old size Bricks for protection of UG Cable in trenches.complete all as specified and directed. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose.
Purbanchal Construction Co
mahinder electricals
M/s. M. G. Babloo Das
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .