Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹3.2 Cr+₹27.7 L (9.40%)Rejected-Finance | ₹3.2 Cr+₹27.7 L (9.40%) | L2 | Rejected-Finance Highest Rate Quoted by bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Techncially Qualified |
Tender Value
₹3.4 Cr
EMD Value
₹6.8 L
Closing Date
16 Jan 2023, 5:00 pmClosed
General Manager(Garhwal)
Office of Chief General Manager, Construction Wing, Uttarakhand Peyjal Nigam, 403/1 Indira Nagar, Dehradun
CONSTRUCTION OF SHED FOR BOILER PLANT, ADDITIONAL ROOM, ADDITIONAL WORKS OF INDUSTRIAL SHED, INDUSTRIAL SPECALISED ELECTRICAL WORK and INTERNAL ROADS AT CAP, SELAQUI, DEHRADUN
2022_MDPEY_53365_1
5451/Nivida(Garh)D.Dun/163 Dt 28-12-2022
Open Tender
Civil Works
Item Rate
365 days
CAP, SELAQUI
Please refer tender document
3 documents required · 3 mandatory
₹5,900
PM,Const.Unit, UKPJN, Dehradun
₹6.8 L
Dehradun
25 Jul 2023
29 Dec 2022
18 Jan 2023
30 Dec 2022
16 Jan 2023
4 Jan 2023
3 Jan 2023
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete.
Construction of embankment with approved material obtained from borrow pits (including cost of compensation for earth taken from private land) with a lift upt 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed by dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bar
Centring and shuttering including strutting,ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water tinnable priming coat with cement prime
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion 110 mm
Bend 87.5° 110 mm bend
Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 C ment : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Design Supply and errection of prefabricated structure frame 610 Sqm. with mezzanine area 162.00 Sqm (as per enclosed specification) inclusive of GST & freight
Mandana stone slab 24mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
Supply and filling of earth including cartage form 10-15 Km
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Supplying and stacking at site. 90 mm to 45 mm size stone aggregate
Distribution Panel RAW POWER ( UTILITY Building) Design, Supplying, Installation , testing & Commissioning of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached. Note: All Panels should be TTA Panels with gas suppression system INCOMER Nos. 250 Amp TPN M.C.C.B. of 35 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 250/5a CTs,CT shorting links.(with each breaker) MAIN BUS BARS 1 set of 300-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 250/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps 1 Sets of LED indicators for each Bus Coupler 'ON', 'OFF', 'TRIP' LED lamps Panel General Accessories - as required for all verticals Panel Light with door switch Space Heater Thermostat 6A SP MCB - 10KA OUTGOING 3 Nos. 125 Amp TPN M.C.C.B. of 35 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 125/5a CTs,CT shorting links.(with each breaker) 1 Nos. 160 Amp TPN M.C.C.B. of 35 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 160/5a CTs,CT shorting links.(with each breaker)
Distribution Panel (UTILITY HOUSE AREA -I ) Design & Supplying of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached. INCOMER 1 Nos. 125Amp TPN M.C.C.B. of 25 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 125/5a CTs,CT shorting links. MAIN BUS BARS 1 set of 150-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 125/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps Panel General Accessories - as required for all verticals Panel Light with door switch Space Heater Thermostat 6A SP MCB - 10KA OUTGOING 03 Nos. 63 Amp TPN MCB. of 10 KA 03 Nos. 40 Amp TPN MCB. of 10 KA 12 Nos. 16 Amp TPN MCB. of 10 KA
Distribution Panel (UTILITY HOUSE AREA -II ) Design & Supplying of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached. INCOMER 1 Nos. 160Amp TPN M.C.C.B. of 25 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 160/5a CTs,CT shorting links. MAIN BUS BARS 1 set of 150-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 160/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps Panel General Accessories - as required for all verticals Panel Light with door switch Space Heater Thermostat 6A SP MCB - 10KA OUTGOING 15 Nos. 32 Amp TPN MCB. of 10 KA 03 Nos. 16 Amp TPN MCB. of 10 KA
Distribution Panel for Light & Power Utility Building Design & Supplying of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached. INCOMER 1 Nos. 125Amp TPN M.C.C.B. of 25 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 125/5a CTs,CT shorting links. MAIN BUS BARS 1 set of 150-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 125/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lampsPanel General Accessories - as required for all verticals Panel Light with door switch Space Heater Thermostat 6A SP MCB - 10KA OUTGOING 6 Nos. 63 Amp TPN MCB. of 10 KA
DISTRIBUTION BOARDS UTILITY BUILDING Supplying, installing ,connecting testing and commissioning of the following industrial type double door horizontal / vertical type IP-43, IK09 with metal door, made of 1.2mm, 1.6mm & 2.0mm thick (As per manufacturer) CRCA sheet steel enclosed fully recessed type, Miniature Circuit Breakers Distribution Boards dust proof, vermin proof, with hinged and panel locks with key doors complete with MCB's and inter-connection with copper wires, or copper tapes, cable glands / conduit entry bushes, bonding to earth and painting. Also provide separate neutral busbar for each phase. Provide separate Earth Links. Use pin type copper lugs or bimetallic lugs for connections of all wires. Distribution Boards 12 Way TPNLDB 12 Way TPN MCB DB. PPI Incomer 63A TPN MCB, 10 KA 40A DP RCCB of 30mA - 3 Nos. Outgoing Each Phase Consisting of the following: - 16/20/25A SP MCB 'C' Curve type -10 Nos.
Distribution Boards 8 Way TPN LDB 8 Way TPN MCB DB. Incomer63A TPN MCB, 10 KA 40A DP RCCB of 30mA - 3 Nos. Outgoing Each Phase Consisting of the following: - 16/20/25A SP MCB 'C' Curve type -6 Nos.
UPS Distribution DB 6 Way TPN MCB DB.Incomer40A TPN MCB, 10 KA25A DP RCCB SI of 30mA - 3 Nos. Outgoing Each Phase Consisting of the following: - 10/20A SP MCB 'C' Curve type - 4 Nos.
12 Way SPN DB for External Light DB Weather Proof Incomer40A DP RCBO of 30mA -1Nos. Outgoing Consisting of the following: - 32Amp DP Contactor & Time Switch 6A SP MCB 'C' Curve type -4 Nos.
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cablee Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement.3.5c x 120 sq.mm armd. Alum. cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cablee Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 3.5c x 95 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cablee Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 3.5c x 50 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cablee Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 3.5c x 35 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cablee Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement.4c x 16 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cablee Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 4c x 10 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cablee Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 4c x 6 sq.mm armd. Alum. Cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5c x 120 sq.mm armd. Alum. cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5c x 50 sq.mm armd. Alum. Cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5c x 35 sq.mm armd. Alum. Cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 4c x 16 sq.mm armd. Alum. Cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 4c x 10 sq.mm armd. Alum. Cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 4c x 6 sq.mm armd. Alum. Cable
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2022-4.6) 100 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2022-4.6) 300 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2022-4.6) 450 mm wide x 50 mm depth x 2.0 mm thickness.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 75 mm wide x 40 mm deep.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 100 mm wide x 40 mm deep.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 150 mm wide x 40 mm deep
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification. 200 mm wide x 40 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 100 mm wide x 50 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 150 mm wide x 50 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 200 mm wide x 50 mm deep.
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 250 mm wide x 50 mm deep.
Light Points for Normal & UPS and FAN Supplying, laying, testing and commissioning of Coduiting & Wiring for primary light points for switch controlled points with 3 x 1.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed / surface mounted 20/25 mm dia MS Conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq mm. FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing of 6 amp 240 Volt grid plate mounted switch with moulded cover plate in 1.2 mm thick G.I box etc. complete as per specifications and as per direction Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for secondary light points with 3x1.5 sq. mm. FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed / surface mounted 20/25 mm dia Medium duty MS conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for Wall Mount FAN & Exhaust fan points with 3 x 2.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in concealed/surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq.mm PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing 5 pin 6 amp shuttered socket outlet a 6 amp 240 volt single pole grid plate mounted switch with moulded cover plate in a recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.( This shall include socket and plug top near fan & switch )
Supplying, laying, testing and commissioning of Coduiting & Wiring for Ceilling FAN points for switch controlled points with 3 x 2.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed / surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq mm. FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing of 6 amp 240 Volt grid plate mounted switch and 2 Module Regulator with moulded cover plate in 1.2 mm thick G.I box etc. complete as per specifications and as per direction Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 6 amp single phase and neutral switch socket outlet with 3 x 2.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined 1 Nos 5 pin 240 volt 6 amp socket outlet with safety shutters and 6 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 6 amp single phase and neutral switch socket outlet with 3 x 2.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined 2 Nos 5 pin 240 volt 6 amp socket outlet with safety shutters and2No 6 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 16 amp single phase and neutral switch socket outlet with 3 x 4 sq. mm PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 4 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined 1 Nos 5 pin 240 volt 16 amp socket outlet with safety shutters and 16 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 6 amp single phase and neutral switch socket outlet with 3 x 4 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS Conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 4 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined 1 Nos 5 pin 240 volt 6/16 amp socket outlet with safety shutters and 16 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.
16A 5 pin & Earth metal clad industrial type socket & plug top controlled by 16A TP MCB to be housed in MS Powder coated box complete with 4 core. 4.0 sqmm + 2 Nos 2.5 Sq.mm. FRLS PVC insulated copper conductor wires. Note:- Avg Circuit length is 20 Mtrs.
32A 5 pin & Earth metal clad industrial type socket & plug top controlled by 32A TP MCB to be housed in MS Powder coated box complete with 4 core. 4.0 sqmm + 2 Nos 2.5 Sq.mm. FRLS PVC insulated copper conductor wires. Note:- Avg Circuit length is 20 Mtrs.
63A 5 pin & Earth metal clad industrial type socket & plug top controlled by 63A TP MCB to be housed in MS Powder coated box complete with 4 core. 6.0 sqmm + 2 Nos 2.5 Sq.mm. FRLS PVC insulated copper conductor wires. Note:- Avg Circuit length is 20 Mtrs.
Supplying, Laying and Fixing of 63 Amp FP MCB with Metal enclouser
Supplying, Laying and Fixing of 32 Amp FP MCB with Metal enclouser
LED HIGH BAY LIGHT - 45 Watt , Pressure die cast Aluminum alloy housing for better thermal conductivity.Seperate driver and optical compartment for hermal isolation. Optical system consists of a injection molded UV stabilized lens for optimum distribution. CCT 5700K & CRI> 70 With Nominal Luminus Flux 5000 Lumens, Integral Silicon encapsulated high efficiency (>85%) electronic driver with rated voltage of 140-270V,Power factor > 0.95 and THD < 10%, Inbuilt surge protection of 5 KV, has mis wiring, Over voltage, Short circuit & Thermal protection,Ingress protection of IP66 and mpact Resistance of IK08, Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015,
Street LED Light - 45 watt Pressure die cast Aluminum alloy housing for better thermal conductivity.Seperate driver and optical compartment for Thermal isolation. Optical system consists of a injection molded UV stabilized lens for optimum distribution. CCT 5700K & CRI> 70 With Nominal Luminous Flux 4500 Lumens, Integral Silicon encapsulated high efficiency (>85%) electronic driver with rated voltage of 140-270V,Power factor > 0.95 and THD < 10%, Inbuilt surge protection of 5 KV, has mis wiring, Over voltage, Short circuit & Thermal protection,Ingress protection of IP66 and Impact Resistance of IK08, Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015,
Wall Mountable bracket of 40 mm dia 1.5 mtr long with Wall mounting clamp and IP 65 Junction box with connector & 6Amp SP MCB .
LED Tube Light 18 Watt Extruded Aluminum alloy housing for better thermal conductivity. . Extruded PC diffuser for optimum light transmission. CCT 6000K & CRI> 80 With Luminus Flux >1800 Lumens, High efficiency driver with inbuild surge protection, over voltage protection, short circuit protection and PF>0.9 & THD < 5%,
LED HIGH BAY LIGHT - 45 Watt , Pressure die cast Aluminum alloy housing for better thermal conductivity.Seperate driver and optical compartment for Thermal isolation. Optical system consists of a injection molded UV stabilized lens for optimum distribution. CCT 5700K & CRI> 70 With Nominal Luminus Flux 5000 Lumens, Integral Silicon encapsulated high efficiency (>85%) electronic driver with rated voltage of 140-270V,Power factor > 0.95 and THD < 10%, Inbuilt surge protection of 5 KV, has mis wiring, Over voltage, Short circuit & Thermal protection,Ingress protection of IP66 and Impact Resistance of IK08, Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015, Suitable for on 50mm Dia pole.
Supply, fixing, testing and commissioning of 240 Volt single phase heavy duty Exhaust Fans 300 mm dia complete with all accessories as required and with 6 amp 3 pin plug top as required.
Supply, fixing, testing and commissioning of 240 Volt single phase Ceiling fan double ball bearing 1200 mm dia complete with all accessories as required.
Supply, fixing, testing and commissioning of 240 Volt single phase Wall Mounted fan double ball bearing 300 mm dia complete with all accessories as required.
SITC of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.036 µΩm, Tensile strength - 120 to 240 MPa or N/mm², Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.
SITC of Stainless Steel Metal roof holder for 8-10 mm dia Aluminium alloy Solid Round Conductor for horizontal Air terminal above metal sheet with fixing screws . Test Parameter: Salt Spray Test ( IEC 62561-1) - No sign of Corrosion
SITC of Glue for fixing matel roof conducter holder over the metal surface to meet the requirment of IS/IEC - 62305 .
SITC of Expansion Piece with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations.Expansion piece should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor . Test Parameter: Electrical Resistivity Test-0.036 µΩm Salt Spray Test - No Sign of Corrosion Tested as per IEC 62561-1
SITC of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305.Tested for Electrical , Mechanical and chemical as per IEC 62561.
SITC of air termination rod of 1 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with H stand and fixing accessories . Test Parameter: Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm² Salt Spray Test-No sign of corrosion Tested as per IEC 62561-1&2
DOWN CONDUCTOR SYSTEM SITC of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.036 µΩm, Tensile strength - 120 to 240 MPa or N/mm², Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.
SITC of Stainless steel Conductor Holder for fixing the 10 mm dia round conductor on the side brick wall . Test Parameter: Salt Spray Test - No Sign of Corrosion Tested as per IEC 62561-1
SITC of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.
SITC of Stainless Steel Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1
EARTHING SYSTEM SITC of Rust resistant non corossive 10 mm dia Copper bonded round conductor used for Earth termination inside the concrete and soil. Test parameter: Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec(IS3043/IEEE80); Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. Tensile Test 290 to 510 N/mm². Adhesion no peel or crack & Bend test no seperation of Cu, Cu Coating thickness min. 70µm. Tested as per IEC 62561-2.
SITC of CAPE make UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 14.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. with 25 Kg earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7, Earth rod Clamp made up of stainless steel terminating cable / flat conductor, Earth Chamber Inspection Pit made up of poly propylene material 10" round shape
Supply, installation, testing and commissioning of LPCB approved Analogue addressable Multisensor Detector (Smoke + Heat) having Intelligent base (hard addressing addressing at base), having inbuilt isolator It shall have multiple modes with min four different sensitivity adjustment, 360° Visible tri colour led for Normal, Fault and Alarm Condition. It shall have hard addressing by means of suitable punched cards. It shall have compensation to drift and transient rejection, It shall be possible to insert and remove detectors by a single push twist movement, base shall have special locking tool feature to prevent loosening of detector on its own.
Supply, installation, testing and commissioning of LPCB approved Analogue addressable Dual Action (PUSH DOWN / PULL PUSH Type) Manual Call Point (Resettable Type) with inbuilt isolator and LED indicator, to be supplied with Junction Box, Glands and other mounting accessories for proper installation.
Supply, Installation, Testing & Commissioning of LPCB approved Analogue Addressable Loop Powered Sounder & Visual Strobe with inbuilt isolator and having Min 10 distinct sound patterns / multitone to indicate Exit doors and direct occupants for safe and fast evacuation variable output starting from 1Hz Frequency flash rate designed for IP65 requirements to be supplied with Junction Box, Glands and other mounting accessories for proper installation.
Supply, Installation, Testing & Commissioning of 1 KM Range Siren with isolator & Module & Power Supply IP65 requirements to be supplied with Junction Box, Glands and other mounting accessories for proper installation.
Supply, Installation, Testing & Commissioning of LPCB approved Analogue addressable Monitor module with inbuilt isolator with LED indicator to be supplied with IP 65 rated Junction Box, Glands and other mounting accessories for proper installation. (
Supply, laying, testing and commissioning of following sizes of Low Smoke Zero Halogen Silicon Insulated Fire Survival unarmd cable with Drain Wire drain wire which shall comprise one plain annealed copper wires with a total nominal cross-sectional area of not less than 2Core x 1.5 sqmm, solid copper conductor cable as per BSEN 50200:2015 PH 120 and BS-6387 CWZ. This cable shall be approved by LPCB. The cable shall sustain 950 deg. C. For 3 hours. The warranty of the products shall run for a period of two (2) years from the date of delivery and connectivity to 25 years (the “Warranty Period”).
Distribution Panel RAW POWER ( Industrial Building) Design, Supplying, Installation , testing & Commissioning of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached. Note: All Panels should be TTA Panels with gas suppression system Incomer Nos. 250 Amp TPN M.C.C.B. of 35 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 250/5a CTs,CT shorting links.(with each breaker) 1 set of 300-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 250/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps 1 Sets of LED indicators for each Bus Coupler 'ON', 'OFF', 'TRIP' LED lamps Panel General Accessories - as required for all verticals Panel Light with door switch Space Heater Thermostat 6A SP MCB - 10KA OUTGOING 4 Nos. 125 Amp TPN M.C.C.B. of 35 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 125/5a CTs,CT shorting links.(with each breaker)
Distribution Panel (Workshop area ) Design & Supplying of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached. INCOMER 1 Nos. 125 Amp TPN M.C.C.B. of 35 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 125/5a CTs,CT shorting links.(with each breaker) MAIN BUS BARS 1 set of 150-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 125/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps 1 Sets of LED indicators for each Bus Coupler 'ON', 'OFF', 'TRIP' LED lamps Panel General Accessories - as required for all verticals Panel Ligh Space Heater t with door switch Thermostat 6A SP MCB - 10KA OUTGOING 18 Nos. 16 Amp TPN MCB. of 10 KA
Distribution Panel (SOLVENT AREA ) Design & Supplying of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached.INCOMER 1 Nos. 100Amp TPN M.C.C.B. of 35 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 100/5a CTs,CT shorting links. MAIN BUS BARS 1 set of 150-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 100/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps Panel General Accessories - as required for all verticalsPanel Light with door switch Space Heater Thermostat 6A SP MCB - 10KA OUTGOING 15Nos. 16 Amp TPN MCB. of 10 KA 2 Nos. 25 Amp TPN MCB. of 10 KA
Distribution Panel (STEAM DISTILLATION AREA ) Design & Supplying of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached. INCOMER 1 Nos. 125Amp TPN M.C.C.B. of 25 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 125/5a CTs,CT shorting links. MAIN BUS BARS 1 set of 150-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 125/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lamps Panel General Accessories - as required for all verticals Panel Light with door switch Space Heater Thermostat 6A SP MCB - 10KA OUTGOING 02 Nos. 40 Amp TPN MCB. of 10 KA 9 Nos. 16 Amp TPN MCB. of 10 KA
Distribution Panel for Light & Power Industrial Building Design & Supplying of following L.T. Panels manufactured out of 14 SWG CRCA . sheet, totally vermin and dust proof duly painted complete with bus bars, neutral links, earth strips, cable alleys etc as required and as per detailed specs with following components & generally to accordance to Cat. drg. attached.INCOMER 1 Nos. 125Amp TPN M.C.C.B. of 25 KA with overload, S/C protection and inclusive 1 Set of Digital energy meter with 125/5a CTs,CT shorting links. MAIN BUS BARS 1 set of 150-Amps 3 phase 4 wire 415 volts 50 HZ aluminium bus bars with colour coded PVC heat shrinkable sleeves (Neutral to be equal to phase size). METERING 1Set of Digital multi function meter with 125/5a CTs,CT shorting links R/Y/B LED indicating lamps and 2a control SP MCBs Sets of LED indicators for each Incoming Breaker 'ON', 'OFF', 'TRIP' LED lampsPanel General Accessories - as required for all verticals Panel Light with door switch Space Heater Thermostat 6A SP MCB - 10KA OUTGOING 5 Nos. 63 Amp TPN MCB. of 10 KA 1 Nos. 100Amp TPN M.C.C.B. of 25 KA with overload, S/C protection
DISTRIBUTION BOARDS Supplying, installing ,connecting testing and commissioning of the following industrial type double door horizontal / vertical type IP-43, IK09 with metal door, made of 1.2mm, 1.6mm & 2.0mm thick (As per manufacturer) CRCA sheet steel enclosed fully recessed type, Miniature Circuit Breakers Distribution Boards dust proof, vermin proof, with hinged and panel locks with key doors complete with MCB's and inter-connection with copper wires, or copper tapes, cable glands / conduit entry bushes, bonding to earth and painting. Also provide separate neutral busbar for each phase. Provide separate Earth Links. Use pin type copper lugs or bimetallic lugs for connections of all wires. Distribution Boards 12 Way TPNLDB 12 Way TPN MCB DB. PPI Incomer 63A TPN MCB, 10 KA 40A DP RCCB of 30mA - 3 Nos. Outgoing Each Phase Consisting of the following: - 16/20/25A SP MCB 'C' Curve type -10 Nos.
Distribution Boards 8 Way TPN LDB 8 Way TPN MCB DB. Incomer 63A TPN MCB, 10 KA40A DP RCCB of 30mA - 3 Nos.Outgoing Each Phase Consisting of the following: - 16/20/25A SP MCB 'C' Curve type -6 Nos.
UPS Distribution DB Incomer 40A TPN MCB, 10 KA 25A DP RCCB SI of 30mA - 3 Nos. Outgoing Each Phase Consisting of the following: - 10/20A SP MCB 'C' Curve type - 4 Nos.
12 Way SPN DB for External Light DB Weather Proof Incomer40A DP RCBO of 30mA -1Nos. Outgoing Consisting of the following: - 32Amp DP Contactor & Time Switch 6A SP MCB 'C' Curve type -4 Nos.
HVAC DB 4 Way TPN MCB DB. Incomer 63A TPN MCB, 10AOutgoing Each Phase Consisting of the following: - 25A SP MCB 'D' Curve type - 4 Nos.
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cable Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 3.5c x 120 sq.mm armd. Alum. cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cable Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 3.5c x 95 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cable Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement.3.5c x 35 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cable Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 4c x 10 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cable Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 4c x 6 sq.mm armd. Alum. Cable
LT XLPE CABLES Supply and Laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at Cable Tray / Existing trench .On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by Engineer- Incharge, complete in all respect .The armouring of the cable shall be proerly connected with earth conductor by clamps etc. Note:- The actual length of cable should be varified at site and get approved from engineer incharge before procurement. 3C x 2.5 sqmm Cu Ar Cable for External Lighting
4C x 6 sqmm Cu Fire survival cable Insulation : Mica (fire - resistant) tapes, covered by an extruded layer of cross - linked polyethylene, An extruded layer of thermoplastic low smoke zero halogen (LSZH) compound. Armour : Single layer of galvanized steel wires. with 2R of 8swg GI wire
3C x 2.5 sqmm Cu Fire survival cable Insulation : Mica (fire - resistant) tapes, covered by an extruded layer of cross - linked polyethylene, An extruded layer of thermoplastic low smoke zero halogen (LSZH) compound. Armour : Single layer of galvanized steel wires.
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5c x 120 sq.mm armd. Alum. cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5c x 95 sq.mm armd. Alum. Cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 4c x 10 sq.mm armd. Alum. Cable
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 4c x 6 sq.mm armd. Alum. Cable flame proof
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3C x 2.5 sq.mm armd. Alum. Cable Cable flame proof
Supply and making end termination with brass compression gland and aluminium lugs for following size fo PVC insulated and PVC sheatehed/XLPE aluminium conductor cable of 1.1 KV grade as required. 3C x 2.5 sq.mm armd. Alum. Cable Cable
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2022-4.6) 100 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2022-4.6) 200 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (DSR-2022-4.6) 300 mm wide x 50 mm depth x 1.6 mm thickness.
Light Points for Normal & UPS and FAN Supplying, laying, testing and commissioning of Coduiting & Wiring for primary light points for switch controlled points with 3 x 1.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed / surface mounted 20/25 mm dia MS Conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq mm. FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing of 6 amp 240 Volt grid plate mounted switch with moulded cover plate in 1.2 mm thick G.I box etc. complete as per specifications and as per direction Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for secondary light points with 3x1.5 sq. mm. FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed / surface mounted 20/25 mm dia Medium duty MS conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for Wall Mount FAN & Exhaust fan points with 3 x 2.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in concealed/surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq.mm PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing 5 pin 6 amp shuttered socket outlet a 6 amp 240 volt single pole grid plate mounted switch with moulded cover plate in a recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.( This shall include socket and plug top near fan & switch )
Supplying, laying, testing and commissioning of Coduiting & Wiring for Ceilling FAN points for switch controlled points with 3 x 2.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed / surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq mm. FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing of 6 amp 240 Volt grid plate mounted switch and 2 Module Regulator with moulded cover plate in 1.2 mm thick G.I box etc. complete as per specifications and as per direction Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 6 amp single phase and neutral switch socket outlet with 3 x 2.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined 1 Nos 5 pin 240 volt 6 amp socket outlet with safety shutters and 6 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 6 amp single phase and neutral switch socket outlet with 3 x 2.5 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 2.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined 2 Nos 5 pin 240 volt 6 amp socket outlet with safety shutters and2No 6 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 16 amp single phase and neutral switch socket outlet with 3 x 4 sq. mm PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 4 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined 1 Nos 5 pin 240 volt 16 amp socket outlet with safety shutters and 16 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 6 amp single phase and neutral switch socket outlet with 3 x 4 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS Conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 4 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined 1 Nos 5 pin 240 volt 6/16 amp socket outlet with safety shutters and 16 amp 240 volt single pole grid plate mounted switch with moulded cover plate in recessed 1.2 mm thick G.I box etc. complete as per specification and as per direction of Project in-charge.
Supplying, laying, testing and commissioning of Conduiting & Wiring for a 5 pin 240 volt 20 amp single phase and neutral switch socket outlet for AC with 3 x 4 sq. mm FRLS PVC insulated stranded copper conductor 1100 Volt grade wires in concealed/surface mounted 20/25 mm dia MS Conduit with fish wire for wire pulling including the cost of providing circuit wiring with 3 x 4 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires and including cost of providing saddles etc as required for surface conduiting and/or cost of cutting and filling chases as required and providing and fixing of a combined with 1 Nos 5 pin 240 volt 20 amp socket outlet with DP MCB of same rating complete as per specification and as per direction of Project in-charge.
16A 5 pin & Earth metal clad industrial type socket & plug top controlled by 16A TP MCB to be housed in MS Powder coated box complete with 4 core. 4.0 sqmm + 2 Nos 2.5 Sq.mm. FRLS PVC insulated copper conductor wires with 32 mm dia MS Conduit . Note:- Avg Circuit length is 20 Mtrs.
32A 5 pin & Earth metal clad industrial type socket & plug top controlled by 32A TP MCB to be housed in MS Powder coated box complete with 4 core. 4.0 sqmm + 2 Nos 2.5 Sq.mm. FRLS PVC insulated copper conductor wires with 32 mm dia MS Conduit . Note:- Avg Circuit length is 20 Mtrs.
Supplying, Laying and Fixing of 63 Amp FP MCB with Metal enclouser
Supplying, Laying and Fixing of 32 Amp FP MCB with Metal enclouser
Power Outlet ( Flame Proof ) Supplying, Installation and Fixing of Flame Proof 1 Ph Socket Rating: 16 Amp 1PH with Plug Top Gas Group: IIA & IIB Protection: IP-65
Supplying, Installation and Fixing of Flame Proof 3 Ph Socket with Plug Top Rating: 16 Amp 3PH, Gas Group: IIA & IIB Protection: IP-65
Supplying, Installation and Fixing of Flame Proof 3 Ph Socket with Plug Top Rating: 25 Amp 3PH, Gas Group: IIA & IIB Protection: IP-65
LED FLAM PROOF LIGHT - 45 Watt ,HIGH BAY light Pressure die cast Aluminum alloy housing Gas Group: IIA & IIB Protection: IP-65 High efficiency driver with inbuilt surge protection, over voltage protection, short circuit protection and PF>0.9 & THD < 5%, impact resistance. CCT 5700K & CRI> 70 With Nominal Luminus Flux 5000 Lumens,Impact Resistance of IK08, Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015, Suitable for Suspension mounting using eyebolt.
LED HIGH BAY LIGHT - 45 Watt , Pressure die cast Aluminum alloy housing for better thermal conductivity.Seperate driver and optical compartment for Thermal isolation. Optical system consists of a injection molded UV stabilized lens for optimum distribution. CCT 5700K & CRI> 70 With Nominal Luminus Flux 5000 Lumens, Integral Silicon encapsulated high efficiency (>85%) electronic driver with rated voltage of 140-270V,Power factor > 0.95 and THD < 10%, Inbuilt surge protection of 5 KV, has mis wiring, Over voltage, Short circuit & Thermal protection,Ingress protection of IP66 and Impact Resistance of IK08, Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015, Suitable for on 50mm Dia pole.
Street LED Light - 45 watt Pressure die cast Aluminum alloy housing for better thermal conductivity.Seperate driver and optical compartment for Thermal isolation. Optical system consists of a injection molded UV stabilized lens for optimum distribution. CCT 5700K & CRI> 70 With Nominal Luminous Flux 4500 Lumens, Integral Silicon encapsulated high efficiency (>85%) electronic driver with rated voltage of 140-270V,Power factor > 0.95 and THD < 10%, Inbuilt surge protection of 5 KV, has mis wiring, Over voltage, Short circuit & Thermal protection,Ingress protection of IP66 and Impact Resistance of IK08, Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015,
Wall Mountable bracket of 40 mm dia 1.5 mtr long with Wall mounting clamp and IP 65 Junction box with connector & 6Amp SP MCB .
LED Tube Light 18 Watt Extruded Aluminum alloy housing for better thermal conductivity. . Extruded PC diffuser for optimum light transmission. CCT 6000K & CRI> 80 With Luminus Flux >1800 Lumens, High efficiency driver with inbuild surge protection, over voltage protection, short circuit protection and PF>0.9 & THD < 5%,
Down Light- 10 Watt Surface Mount Pressure die cast Aluminum alloy housing for better thermal conductivity. Injection molded UV Stabilized lens cover with high impact resistance. CCT 5700K & CRI> 80 With Nominal Luminus Flux 1000 Lumens, High efficiency driver with inbuild surge protection, over voltage protection, short circuit protection and operating , Power factor > 0.90 and THD < 10%, Inbuilt surge protection of2 KV, Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015, Cut out dia of 165mm and Overall dia of 178mm.
Bulk Head Light 10 watt - Extruded Aluminum alloy housing for better thermal conductivity. . Extruded PC diffuser for optimum light transmission. CCT 4000K & CRI> 80 With Luminus Flux >1200 Lumens, rated voltage of 140-270V,Power factor > 0.95 and THD < 10%, Inbuilt surge protection of 2 KV, has mis wiring, Over voltage, Short circuit & Thermal protection,Ingress protection of IP66 and Impact Resistance of IK08
Supply, fixing, testing and commissioning of 240 Volt single phase heavy duty Exhaust Fans 300 mm dia complete with all accessories as required and with 6 amp 3 pin plug top as required.
Supply, fixing, testing and commissioning of 240 Volt single phase Ceiling fan double ball bearing 1200 mm dia complete with all accessories as required.
Supply, fixing, testing and commissioning of 240 Volt single phase Wall Mounted fan double ball bearing 300 mm dia complete with all accessories as required.
SITC of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.036 µΩm, Tensile strength - 120 to 240 MPa or N/mm², Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.
SITC of Stainless Steel Metal roof holder for 8-10 mm dia Aluminium alloy Solid Round Conductor for horizontal Air terminal above metal sheet with fixing screws . Test Parameter: Salt Spray Test ( IEC 62561-1) - No sign of Corrosion
SITC of Glue for fixing matel roof conducter holder over the metal surface to meet the requirment of IS/IEC - 62305 .
SITC of Stainless steel Cross Connector for 8 mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross junction. Test Parameter Salt Spray Test ( IEC 62561-1) - No sign of Corrosion
SITC of Expansion Piece with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations.Expansion piece should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor . Test Parameter: Electrical Resistivity Test-0.036 µΩm Salt Spray Test - No Sign of Corrosion Tested as per IEC 62561-1
SITC of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305.Tested for Electrical , Mechanical and chemical as per IEC 62561.
SITC of air termination rod of 1 mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends(Tappered Type). The rod shall be mounted with H stand and fixing accessories . Test Parameter: Mechanical Load Test for individual aluminium alloy rods - 120 to 280 N/mm² Salt Spray Test-No sign of corrosion Tested as per IEC 62561-1&2
SITC of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination and down conductor system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.036 µΩm, Tensile strength - 120 to 240 MPa or N/mm², Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2.
SITC of Stainless steel Conductor Holder for fixing the 10 mm dia round conductor on the side Sheet wall . Test Parameter: Salt Spray Test - No Sign of Corrosion Tested as per IEC 62561-1
SITC of Stainless steel Conductor Holder for fixing the 10 mm dia round conductor on the side brick wall . Test Parameter: Salt Spray Test - No Sign of Corrosion Tested as per IEC 62561-1
SITC of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6.
SITC of Stainless Steel Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1
SITC of Rust resistant non corossive 10 mm dia Copper bonded round conductor used for Earth termination inside the concrete and soil. Test parameter: Short circuit current test for copper bonded conductor:Test 6 kA ratings, as per cross sectional area for 1 sec(IS3043/IEEE80); Electrical Resistivity before & after salt mist spray test: 0.25µΩm max. Tensile Test 290 to 510 N/mm². Adhesion no peel or crack & Bend test no seperation of Cu, Cu Coating thickness min. 70µm. Tested as per IEC 62561-2.
SITC of CAPE make UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 14.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. with 25 Kg earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7, Earth rod Clamp made up of stainless steel terminating cable / flat conductor, Earth Chamber Inspection Pit made up of poly propylene material 10" round shape
Supply, installation, testing and commissioning of EN/VDS approved addressable Networkable analogue addressable type fire alarm control panel with 4.3" fullu automated touch screen display with 3 user level protection for field programming without using any king of DONGLE OR SPECIAL CABLE. The panel should be equipped with 3 loop expandable upto 5 loop with 10% spare capacity, with each networkable intelligent fire alarm Control Panel having loop capacity of min 126 detectors and devices per loop (any combination) with dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50 Hz with built in charger. The panel shall have fire, fault relays, Option for BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 1000 event record facility, event fetch from FACP facility and inbuilt printer attachable facility. The panels hould have networking facility with max 32 panels in one network with all other accessories required to successfully run the system.This panel shall have inbuilt battery backup for 48Hr in normal condition and 30 minute backup in fire condition. 3 Loop Panel.
Supply, Installation, Testing & Commissioning of EN/VDS approved Network active Repeater Panel with 4.3" fully automated touch screen display, The screen shall Display all events/ detectors, devices status of complete systems in the networked
Supply, installation, testing and commissioning of LPCB approved Analogue addressable Multisensor Detector (Smoke + Heat) having Intelligent base (hard addressing addressing at base), having inbuilt isolator It shall have multiple modes with min four different sensitivity adjustment, 360° Visible tri colour led for Normal, Fault and Alarm Condition. It shall have hard addressing by means of suitable punched cards. It shall have compensation to drift and transient rejection, It shall be possible to insert and remove detectors by a single push twist movement, base shall have special locking tool feature to prevent loosening of detector on its own.
Supply, installation, testing and commissioning of LPCB approved Analogue addressable Dual Action (PUSH DOWN / PULL PUSH Type) Manual Call Point (Resettable Type) with inbuilt isolator and LED indicator, to be supplied with Junction Box, Glands and other mounting accessories for proper installation.
Supply, Installation, Testing & Commissioning of LPCB approved Analogue Addressable Loop Powered Sounder & Visual Strobe with inbuilt isolator and having Min 10 distinct sound patterns / multitone to indicate Exit doors and direct occupants for safe and fast evacuation variable output starting from 1Hz Frequency flash rate designed for IP65 requirements to be supplied with Junction Box, Glands and other mounting accessories for proper installation.
Supply, Installation, Testing & Commissioning of LPCB approved Analogue addressable Monitor module with inbuilt isolator with LED indicator to be supplied with IP 65 rated Junction Box, Glands and other mounting accessories for proper installation. (
Supply, laying, testing and commissioning of following sizes of Low Smoke Zero Halogen Silicon Insulated Fire Survival unarmd cable with Drain Wire drain wire which shall comprise one plain annealed copper wires with a total nominal cross-sectional area of not less than 2Core x 1.5 sqmm, solid copper conductor cable as per BSEN 50200:2015 PH 120 and BS-6387 CWZ. This cable shall be approved by LPCB. The cable shall sustain 950 deg. C. For 3 hours. The warranty of the products shall run for a period of two (2) years from the date of delivery and connectivity to 25 years (the “Warranty Period”).
Supply and laying of CAT6 cablein inside 20mm dia MS conduit 1.6 mm thick for networking
Supply and laying of 25mm MS conduit laid on surface / on tray / MS support with complete all accessories, as per standards & specifications. The rate shall include material all accessories (like screw, nuts, clamps, JB, MS support, etc..) including associated civil works (like chipping, plastering, drilling etc..) and required to complete the job.
Supply and laying of 32mm MS conduit laid on surface / on tray / MS support with complete all accessories, as per standards & specifications. The rate shall include material all accessories (like screw, nuts, clamps, JB, MS support, etc..) including associated civil works (like chipping, plastering, drilling etc..) and required to complete the job.
M.S. SECTION SUPPORTS Fabrication, Supply, Installation of various MS Section fabricated support for L.T. Cables in trench, cover of cable trenhes with Chequerred plate making of stand for DB's etc. Cost to include supply of all material & Labour including two coats of Zinc Chromate primmer & final air drying enamel, paint of approved shade, Anchor bolts, minor civil work. 8 mm flexible steel wire rope with levelers, adjusting clamps etc. All fabricated frames and supports to be painted with 2 coats of primer and 2 coats of wet paint (shade: RAL 9010) BEFORE fixing the same.
Safety Items 1.1 kV grade rubber mat of 1 meter width in Main LT room, UPS room, Machine room and Boiler room.
Supply and installation of the following portable fire extinguishers. 5 Kg dry ABC Fire extinguishers
Supply and installation of the following portable fire extinguishers. 5 Kg CO2 fire extinguishers.
Supply and fixing of 9 liters capacity fire buckets filled with dry sand including mounting MS stand.
Supply and installation of shock treatment charts as per local supply authority duly framed.
Supply and providing first aid box complete with all first aid medicines.
Supply of 11 K.V. grade hand gloves
Supplying and Installation of 1.1 KV danger plate.
Supplying and laying of the following sizes of Heavy duty DWC Pipes complete with T's, bends etc as required below paved area including chase cutting and back filling.The scope shall include excavation of any type of soil, sand moorun depth and refilling after laying of pipe, ramming and disposal surplus soil. 100 mm dia
M/S Ravindra Builders and Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .