Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.0 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | ₹6.0 L Quoted ₹5.0 L | 1 | Accepted-AOC L1 |
| 2 | 2₹5.6 LRejected-Finance | ₹5.6 L | 2 | Rejected-Finance L2 |
| 3 | 3₹5.8 LRejected-Finance | ₹5.8 L | 3 | Rejected-Finance L3 |
| 4 | 4₹6.5 LRejected-Finance UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | ₹6.5 L | 4 | Rejected-Finance L4 |
Tender Value
₹5.9 L
EMD Value
₹11,853
Closing Date
23 Jan 2026, 11:00 amClosed
Ex. Engineer (Elect)/CSPZ
OFFICE OF THE EX. ENGINEER (ELECT)/CSPZ UNDER GROUND CAR PARKING ASAF ALI ROAD, DELHI-110002
Repairing of Non functional Tube wells installed at various Municipal Parks under City SP Zone.
2026_MCD_263127_1
67/MWEEE-I/2025-26/TC
Open Tender
Electrical Works
90 days
CSPZ
Refer special conditions
2 documents required · 2 mandatory
₹590
₹11,853
3 Mar 2026
15 Jan 2026
23 Jan 2026
15 Jan 2026
23 Jan 2026
15 Jan 2026
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. Up to 35 sq.mm.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40A
Lifting of existing submersible pump set with all accessories from well and lowering the same along with all assessories for the depth Up to 50 meter complete as reqd.
Rewinding of single / three phase AC motors of vertical type multi stage submersible pump sets of following rating :- (a) Single phase 1.5 HP
single phase 3 HP
three phase 5 HP
three phase 7.5 HP
Repairing of pumping unit of 1/1.5/3 HP vertical type multi stage, submersible pump set by replacement of following accessories/parts etc. Complete as reqd. Gun metal bush / bearing.
Pump Shaft
Impeller
Repairing of pumping unit of 5/7.5/10 HP vertical type multi stage, submersible pump set by replacement of following accessories/parts etc. Complete as reqd. Gun metal bush / bearing.
Pump Shaft.
Impeller.
Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or line i/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when gravel stop sinking discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd.
Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd
a. Single Phase 1.5 HP having discharge of 72 LPM Approx. at 49 M Head
b. Single Phase 3.0 HP having discharge of 100 LPM Approx. at 52 M Head
c Three Phase 5.0 HP having discharge of 300 LPM Approx. at 39 M Head.
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*10 sqmm
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
P&F following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd.
3 X 2.5 sq.mm.
3 X 6 sq. mm
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connectionstesting and commissioning etc. as required.,
Double pole
Triple pole
Supply, lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc. ISI marked etc as reqd.
32mm(Nominal Bore)
40mm(Nominal Bore)
50mm(Nominal Bore)
S & F following size of G.I. Socket. as reqd.
S & F following size of G.I. Elbow. as reqd..
S & F MS clamp made up of iron flat of size 50X6 mm with 4 nut bolt for holding the GI pipe pipe as reqd.
Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd.
1.5 HP (Single Phase)
3 HP (Three Phase)
5 HP (Three Phase)
Replacement of following items for cubicle panel etc as required.
Capacitor (36 micro farad)
Capacitor (50 micro farad)
Capacitor (72 micro farad)
Contractor & relay of single phase starter unit
Contractor & relay of three phase starter unit
S.I.T.C of Hot Press moulded SMC panel/Canopy Box of size(OD) 920 mm x 460 mm x 260 mm & (ID) 900 mm x 450 mm x250 mm , anti – corrosive, dust proof, rust proof, shock proof , Self-extinguishing property , resistant to heat , Vermin proof, Ultra Violet stabilized, Pilfer resistant, Suitable for mounting 1 no. 3 phase Starter, 1 no. 63 Amp 4 pole isolator and 1 no. 3 phase Energy meter, Socket for outgoing connection with pilferage proof SMC door duly welded with S/S handle having danger logo on its outer surface and with 1 no Hot Dip galvanized iron stand for a base of size 40 mm x 40 mm x 5 mm and height of the stand is 600 mm including 300 mm height below the ground with side strip of size 25 x 5 mm.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 25mm x 5mm GI strip on surface or in recess for connections etc as req.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.84 MB
Tendernotice_2.pdf
PDF • 26.38 MB
Tendernotice_3.pdf
PDF • 0.70 MB
DNIT_001.pdf
Tender Documents • 5.11 MB
BOQ_305025.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid