Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAdmitted-Fee/PreQual/Technical/Finance | ₹4.3 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹4.4 L+₹2,666 (0.62%)Admitted-Fee/PreQual/Technical/Finance AT JHARKHAND 15 NO KEDLA DIST RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 825101 | ₹4.4 L+₹2,666 (0.62%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹5.4 L+₹1.1 L (25.0%)Admitted-Fee/PreQual/Technical/Finance | ₹5.4 L+₹1.1 L (25.0%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | L4₹7.2 L+₹2.9 L (66.2%)Admitted-Fee/PreQual/Technical/Finance | ₹7.2 L+₹2.9 L (66.2%) | L4 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Electro Enterprises L4 | Soni and Sons Enterprises L1 | M S VIJAY CONTRACTOR SUPPLIER L2 | SINGH ELECTRICALS L3 |
|---|---|---|---|---|---|---|---|
| 2.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable ete as required.
Group A | 165 | nos | 870 ₹1,43,550 | 450 ₹74,250 | 160 ₹26,400 Lowest | 760 ₹1,25,400 |
| 3.00 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group B | 55 | nos | 550 ₹30,250 | 353.6 ₹19,448 | 200 ₹11,000 Lowest | 476.25 ₹26,193.75 |
| 4.00 | Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed as required. 2X1.5 sq.mm + 1X1.5 sq.mm | 345 | mtr | 205 ₹70,725 | 110 ₹37,950 Lowest | 180 ₹62,100 | 177.5 ₹61,237.5 |
| 5.00 | Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed as required. 2X2.5 sq.mm + 1X2.5 sq.mm earth wire | 255 | mtr | 250 ₹63,750 | 156.4 ₹39,882 Lowest | 210 ₹53,550 | 212.5 ₹54,187.5 |
| 6.00 | Wiring for light power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 120 | mtr | 310 ₹37,200 | 191.76 ₹23,011.2 | 180 ₹21,600 Lowest | 340 ₹40,800 |
| 7.00 | Service wire 2X6 SQMM copper | 210 | mtr | 205 ₹43,050 | 125.8 ₹26,418 | 110 ₹23,100 Lowest | 172.5 ₹36,225 |
| 8.00 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc, as required. | 12 | nos | 335 ₹4,020 | 214.88 ₹2,578.56 Lowest | 450 ₹5,400 | 292.5 ₹3,510 |
| 9.00 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, eartlı bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator). 6 wav, Double door | 6 | nos | 1,950 ₹11,700 | 1,285.88 ₹7,715.28 | 220 ₹1,320 Lowest | 1,760 ₹10,560 |
| 10.00 | Supplying and fixing 5A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral | 16 | nos | 550 ₹8,800 | 352.24 ₹5,635.84 Lowest | 6,300 ₹1,00,800 | 482.5 ₹7,720 |
| 11.00 | Supplying, installing. testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.
63 Α ΤΡΝ | 2 | nos | 10,650 ₹21,300 | 6,876.84 ₹13,753.68 Lowest | 12,000 ₹24,000 | 9,456.25 ₹18,912.5 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
9 Jun 2026, 6:55 pmClosed
SO(ENM)
GM UNIT KUJU
Repairing and rewiring of Naya More Hospital, Quality Control room, Naya More ENM workshop, and Area Sales Office under GM Unit Kuju.
2026_CCL_360437_1
GM (K)/EnT/eTender/26-27/29
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
GM UNIT KUJU
2 documents required · 2 mandatory
₹10,000
17 Jun 2026
29 May 2026
10 Jun 2026
29 May 2026
9 Jun 2026
29 May 2026
29 May 2026 - 6 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable ete as required.
Group A | 165 | nos | - | - |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group B | 55 | nos | - | - |
| 4 | Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed as required. 2X1.5 sq.mm + 1X1.5 sq.mm | 345 | mtr | - | - |
| 5 | Wiring for circuit submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed as required. 2X2.5 sq.mm + 1X2.5 sq.mm earth wire | 255 | mtr | - | - |
| 6 | Wiring for light power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 120 | mtr | - | - |
| 7 | Service wire 2X6 SQMM copper | 210 | mtr | - | - |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc, as required. | 12 | nos | - | - |
| 9 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, eartlı bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator). 6 wav, Double door | 6 | nos | - | - |
| 10 | Supplying and fixing 5A to 32 As rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral | 16 | nos | - | - |
| 11 | Supplying, installing. testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.
63 Α ΤΡΝ | 2 | nos | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.20 MB
BOQ_373302.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .