| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.4 LAdmitted-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹65.4 L | L1 | Admitted-Finance |
| 2 | L2₹65.5 LAdmitted-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | ₹65.5 L | L2 | Admitted-Finance |
| 3 | L3₹99.3 LAdmitted-Finance UPPER SARTHI VIHAR AJABPUR DANDA PO NEHRU GRAM POLICE STATION DALANWALA HARIDWAR ROAD DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹99.3 L | L3 | Admitted-Finance |
| 4 | Rejected-Technical 13 218 MASJI EXTN SADAR BAZAR DELHI CANTT 10 | DELHI | DELHI | DELHI | 10 | - | - | Rejected-Technical Not enlisted in appropriate Category as per NIT |
| Sl No | Description | Qty | Unit | Roy and Sons Infrastructures L1 | Garhwal Enterprises L3 | bharat contrectors L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning transformer step down 11/0.433 KV outdoor type plinth mounted, copper wound AC 3 Phase, 50 Hz oil immersed naturally cooled, ONAN with external cooling tube, delta connected on primary side (11 KV HV side) & star connected on secondary side (433 V LV side) in accordance with vector group Dyn-11 with neutral brought out on secondary side with tapping at ± 2.5% ±5% ±7.5% off load tap changer gear in steps of 2.5% continous rating of capacity 100 KVA including initial oil fill to appropriate level & all standard fitting all as per IS 1180 and maximum temp rise should not exceeds 40 degree celcius in oil and 45 degree celcius in HV/LV windings when measured by resistance method afterr contionious full load run on ambient temperature on 40 degree celcius complete all as specified and directed. The unit rate for each transformer includes the cost of following accessories/fittings :- | 4 | Each | 6,12,000 ₹24.5 L | 9,50,000 ₹38 L | 7,00,000 ₹28 L |
| 1.10(a) Rating and terminal marking plates, non detachable (b) Earthing terminals with lugs-02 Nos (c) Lifting lugs for main tank and top cover (d) Thermometer pocket with cap along with dial type thermometer-01 No (e) Externally hand operated OFF circuit tap, changing device with locking arrangement. (f) Oil conservator tank with fitting hole, drain plug, prismatic oil level gauge. (g) Silica gel dehydrating breather charged with silica gel. (h) Top filter valve with plug (j) Drain valve with plug (k) Air Release Valve (l) Explosive Vent (m) Earthing terminals with lugs-02 Nos (n) Lifting hooks. (o) Unidirectional reversible roller-04 Nos. (p) HV copper bushing-03 Nos. (q) LV copper bushing-04 Nos. (r) Radiators. (s) Arcing horn on HT side-03 Nos. (t) Terminal connection on the HV bushing. (u) Additional neutral separately brought out side, LV cable end box with bush insulator for neutral earthing, gland etc. (v) First fill of Transformer oil upto appropriate level. (w) Base channel 100x50 mm, 460 mm long with holes to make them suitable for fixing on a platform or plinth (x) Danger Notice Plate - 01 No. Note : 1. The Trasformer shall be ISI marked with min energy efficiency level 3 as per IS 1180 (Pt-I) : 2014. 2. Any other accessories/work which is required to be provided as per relivent IS but not specified above will be provided by the firm without any extra cost to the Department . | ||||||
| 2.00 | Supply, install, testing and commissioning transformer step down 11/0.433 KV outdoor type plinth mounted, copper wound AC 3 Phase, 50 Hz oil immersed naturally cooled, ONAN with external cooling tube, delta connected on primary side (11 KV HV side) & star connected on secondary side (433 V LV side) in accordance with vector group Dyn-11 with neutral brought out on secondary side with tapping at ± 2.5% ±5% ±7.5% off load tap changer gear in steps of 2.5% continous rating of capacity 200 KVA including initial oil fill to appropriate level & all standard fitting all as per IS 1180 and maximum temp rise should not exceeds 40 degree celcius in oil and 45 degree celcius in HV/LV windings when measured by resistance method afterr contionious full load run on ambient temperature on 40 degree celcius complete all as specified and directed. The unit rate for each transformer includes the cost of following accessories/fittings :- | 3 | Each | 9,60,000 ₹28.8 L | 17,35,000 ₹52.0 L | 10,00,000 ₹30 L |
| 2.10(a) Rating and terminal marking plates, non detachable (b) Earthing terminals with lugs-02 Nos (c) Lifting lugs for main tank and top cover (d) Thermometer pocket with cap along with dial type thermometer-01 No (e) Externally hand operated OFF circuit tap, changing device with locking arrangement. (f) Oil conservator tank with fitting hole, drain plug, prismatic oil level gauge. (g) Silica gel dehydrating breather charged with silica gel. (h) Top filter valve with plug (j) Drain valve with plug (k) Air Release Valve (l) Explosive Vent (m) Earthing terminals with lugs-02 Nos (n) Lifting hooks. (o) Unidirectional reversible roller-04 Nos. (p) HV copper bushing-03 Nos. (q) LV copper bushing-04 Nos. (r) Radiators. (s) Arcing horn on HT side-03 Nos. (t) Terminal connection on the HV bushing. (u) Additional neutral separately brought out side, LV cable end box with bush insulator for neutral earthing, gland etc. (v) First fill of Transformer oil upto appropriate level. (w) Base channel 100x50 mm, 460 mm long with holes to make them suitable for fixing on a platform or plinth (x) Danger Notice Plate - 01 No. Note : 1. The Trasformer shall be ISI marked with min energy efficiency level 3 as per IS 1180 (Pt-I) : 2014. 2. Any other accessories/work which is required to be provided as per relivent IS but not specified above will be provided by the firm without any extra cost to the Department . | ||||||
| 3.00 | Supply, installation, commissioning and testing in replacement of HT 11 KV outdoor type gang operated triple pole air break switch suitable for Horizontal or vertical mounting fixed type complete with 12 insulator 200 amps rating and steel frame mechanically oprated mechanism consisting of operating rod of 25 mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50 mmx6mm including MS channel of suitable size length for fixing GOD including bolts, nuts and washer complete all as specified and directed. | 5 | Each | 25,000 ₹1.3 L | 11,000 ₹55,000 | 12,000 ₹60,000 |
| 4.00 | Supply, installation, testing and commissioning in replacement of Lighting Arresters non linear Metal oxide type, distribution class with all fittings arrangements suitable to 11000 volts grade and discharge capacity 12 KV/10KA with and incuding lighting counter and cable of sutable size and core from lightning arrestor to ligting counter complete all as specified & directed. | 5 | Set of Three | 18,000 ₹90,000 | 9,000 ₹45,000 | 4,000 ₹20,000 |
| 5.00 | Taking up/down of old U/S HT armoured cable and Supply and lay XLPE insulated, screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (conforming to IS 7098), grade (earthed) cross sectional area 95 Sqmm, 3 core complete all as specified and directed.
Note;- The earth work, HDPE pipe shall be measured and paid sepretely under appropriate item of Sch A | 190 | RM | 1,086 ₹2.1 L | 1,100 ₹2.1 L | 1,050 ₹2.0 L |
| 6.00 | S&F in replacement cable jointing kit 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cabe of size 95 sqmm , complete all as specfied and directed. | 14 | EACH | 7,000 ₹98,000 | 8,000 ₹1.1 L | 3,000 ₹42,000 |
| 7.00 | Excavating in trenches n exc 1.5 m width and n exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. | 21 | Cum | 300 ₹6,300 | 500 ₹10,500 | 150 ₹3,150 |
| 8.00 | Returning filling in including spreading, leveling,watering and well ramming in layers not exc 25 cm in Hard/Dense Soil complete all as specified and directed. | 18.5 | Cum | 80 ₹1,480 | 250 ₹4,625 | 50 ₹925 |
Updated dates
Tender Value
₹70.9 L
EMD Value
₹1.3 L
Closing Date
19 May 2026, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 248003
SPECIAL REPAIR/REPLACEMENT OF VARIOUS CAPACITY OF LT DISTRIBUTION TRANSFORMERS AGAINST BER AND CONNECTED WORK UNDER AGE(I) MES LANSDOWNE
2026_MES_759905_1
87294/LDN/E8
Open Tender
Electrical and Maintenance Works
150 days
AGE (I) Lansdowne
Class C Cat b (ii)
6 documents required · 6 mandatory
₹1,000
Yes
AGE (I) Lansdowne
₹1.3 L
Yes
9 Jun 2026
10 Apr 2026
27 May 2026
10 Apr 2026
19 May 2026
6 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, install, testing and commissioning transformer step down 11/0.433 KV outdoor type plinth mounted, copper wound AC 3 Phase, 50 Hz oil immersed naturally cooled, ONAN with external cooling tube, delta connected on primary side (11 KV HV side) & star connected on secondary side (433 V LV side) in accordance with vector group Dyn-11 with neutral brought out on secondary side with tapping at ± 2.5% ±5% ±7.5% off load tap changer gear in steps of 2.5% continous rating of capacity 100 KVA including initial oil fill to appropriate level & all standard fitting all as per IS 1180 and maximum temp rise should not exceeds 40 degree celcius in oil and 45 degree celcius in HV/LV windings when measured by resistance method afterr contionious full load run on ambient temperature on 40 degree celcius complete all as specified and directed. The unit rate for each transformer includes the cost of following accessories/fittings :- | |||||
| 1.1 | (a) Rating and terminal marking plates, non detachable (b) Earthing terminals with lugs-02 Nos (c) Lifting lugs for main tank and top cover (d) Thermometer pocket with cap along with dial type thermometer-01 No (e) Externally hand operated OFF circuit tap, changing device with locking arrangement. (f) Oil conservator tank with fitting hole, drain plug, prismatic oil level gauge. (g) Silica gel dehydrating breather charged with silica gel. (h) Top filter valve with plug (j) Drain valve with plug (k) Air Release Valve (l) Explosive Vent (m) Earthing terminals with lugs-02 Nos (n) Lifting hooks. (o) Unidirectional reversible roller-04 Nos. (p) HV copper bushing-03 Nos. (q) LV copper bushing-04 Nos. (r) Radiators. (s) Arcing horn on HT side-03 Nos. (t) Terminal connection on the HV bushing. (u) Additional neutral separately brought out side, LV cable end box with bush insulator for neutral earthing, gland etc. (v) First fill of Transformer oil upto appropriate level. (w) Base channel 100x50 mm, 460 mm long with holes to make them suitable for fixing on a platform or plinth (x) Danger Notice Plate - 01 No. Note : 1. The Trasformer shall be ISI marked with min energy efficiency level 3 as per IS 1180 (Pt-I) : 2014. 2. Any other accessories/work which is required to be provided as per relivent IS but not specified above will be provided by the firm without any extra cost to the Department . | - | - | - | - |
| 2Supply, install, testing and commissioning transformer step down 11/0.433 KV outdoor type plinth mounted, copper wound AC 3 Phase, 50 Hz oil immersed naturally cooled, ONAN with external cooling tube, delta connected on primary side (11 KV HV side) & star connected on secondary side (433 V LV side) in accordance with vector group Dyn-11 with neutral brought out on secondary side with tapping at ± 2.5% ±5% ±7.5% off load tap changer gear in steps of 2.5% continous rating of capacity 200 KVA including initial oil fill to appropriate level & all standard fitting all as per IS 1180 and maximum temp rise should not exceeds 40 degree celcius in oil and 45 degree celcius in HV/LV windings when measured by resistance method afterr contionious full load run on ambient temperature on 40 degree celcius complete all as specified and directed. The unit rate for each transformer includes the cost of following accessories/fittings :- | |||||
| 2.1 | (a) Rating and terminal marking plates, non detachable (b) Earthing terminals with lugs-02 Nos (c) Lifting lugs for main tank and top cover (d) Thermometer pocket with cap along with dial type thermometer-01 No (e) Externally hand operated OFF circuit tap, changing device with locking arrangement. (f) Oil conservator tank with fitting hole, drain plug, prismatic oil level gauge. (g) Silica gel dehydrating breather charged with silica gel. (h) Top filter valve with plug (j) Drain valve with plug (k) Air Release Valve (l) Explosive Vent (m) Earthing terminals with lugs-02 Nos (n) Lifting hooks. (o) Unidirectional reversible roller-04 Nos. (p) HV copper bushing-03 Nos. (q) LV copper bushing-04 Nos. (r) Radiators. (s) Arcing horn on HT side-03 Nos. (t) Terminal connection on the HV bushing. (u) Additional neutral separately brought out side, LV cable end box with bush insulator for neutral earthing, gland etc. (v) First fill of Transformer oil upto appropriate level. (w) Base channel 100x50 mm, 460 mm long with holes to make them suitable for fixing on a platform or plinth (x) Danger Notice Plate - 01 No. Note : 1. The Trasformer shall be ISI marked with min energy efficiency level 3 as per IS 1180 (Pt-I) : 2014. 2. Any other accessories/work which is required to be provided as per relivent IS but not specified above will be provided by the firm without any extra cost to the Department . | - | - | - | - |
| 3Supply, installation, commissioning and testing in replacement of HT 11 KV outdoor type gang operated triple pole air break switch suitable for Horizontal or vertical mounting fixed type complete with 12 insulator 200 amps rating and steel frame mechanically oprated mechanism consisting of operating rod of 25 mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50 mmx6mm including MS channel of suitable size length for fixing GOD including bolts, nuts and washer complete all as specified and directed. | |||||
| 4Supply, installation, testing and commissioning in replacement of Lighting Arresters non linear Metal oxide type, distribution class with all fittings arrangements suitable to 11000 volts grade and discharge capacity 12 KV/10KA with and incuding lighting counter and cable of sutable size and core from lightning arrestor to ligting counter complete all as specified & directed. | |||||
| 5Taking up/down of old U/S HT armoured cable and Supply and lay XLPE insulated, screened, PVC bedded, galvanized steel strip armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (conforming to IS 7098), grade (earthed) cross sectional area 95 Sqmm, 3 core complete all as specified and directed. Note;- The earth work, HDPE pipe shall be measured and paid sepretely under appropriate item of Sch A | |||||
| 6S&F in replacement cable jointing kit 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cabe of size 95 sqmm , complete all as specfied and directed. | |||||
| 7Excavating in trenches n exc 1.5 m width and n exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. | |||||
| 8Returning filling in including spreading, leveling,watering and well ramming in layers not exc 25 cm in Hard/Dense Soil complete all as specified and directed. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender87294.pdf
Tender Documents • 1.15 MB
BOQ_851155.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid