| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹10.0 L Quoted ₹10.2 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹10.7 L+₹43,019 (4.20%)Rejected-AOC | ₹10.7 L+₹43,019 (4.20%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹13.0 L+₹2.7 L (26.8%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | ₹13.0 L+₹2.7 L (26.8%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹13.3 L+₹3.1 L (30.2%)Rejected-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹13.3 L+₹3.1 L (30.2%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹13.7 L+₹3.5 L (33.9%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹13.7 L+₹3.5 L (33.9%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
10 Jan 2023, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ CWE HILLS DEHRADUN, MALL ROAD, Dehradun Cantt -248003
REPAIR AND REPLACEMENT OF CERTAIN ELECTRIC WIRING, FITTING, FIXTURES , LIGHTENING CONDUCTOR AND EARTH PITS IN OTM ACCN AT MIL STATION RAIWALA
2022_MES_569316_1
86381/RWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) RAIWAL
Class E Category b(i)
7 documents required · 7 mandatory
₹500
AGE I RAIWALA
₹30,000
Yes
28 Feb 2023
15 Dec 2022
17 Jan 2023
15 Dec 2022
10 Jan 2023
29 Dec 2022
Amount
Dismantling and taking down old unserviceable point wiring of any type (light, fan, socket, power etc) complete with fitting such as switches, sockets, ceiling roses, pendants, lamp holders, light fitting etc including CI/ pressed steel terminals, switch box and making good the disturbed surface of wall/ floor etc to match with the existing surfaces of wall/ floor complete all as specified and directed. Note :- (i) If the contractor fail to make good the disturbed surface of wall/ floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute, the decision of Accepting Officer will be final and binding. (ii) Old fittings/ fixtures / accessories like switches, sockets, lamp holders, regulators etc., if found in serviceable condition shall be removed carefully for reuse in the work or taking on charge. (iii) Only old unserviceable items will be considered in credit Sch.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit "medium grade" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:- Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
One light point controlled by two way 5 Amp switch.
Descrition same all as per item No 2 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in existing concealed conduit (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
One light point controlled by two way 5 Amp switch.
Descrition same all as per item No 4 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including PVC Casing caping (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
One light point controlled by two way 5 Amp switch.
Descrition same all as per item No 6 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S&F modular switch piano, 1module, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or equilent make as specified.
S&F modular switch piano, 1module, flush type button 15/16 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand Cat No: 6734 11/ Indoasian Cat No: 800002 or equilent make as specified.
S&F modular socket outlet, 2 module, five pin 2 in 1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Legrand Cat No: 6734 52 / Indoasian Cat No: 800020 or equilent make as specified.
S&F modular socket outlet, 2 module, five pin 2 in1, 15 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Legrand Cat No: 6734 55 / Indoasian Cat No: 800022 or equilent make as specified.
S&F modular switch piano, 1module, flush type button 5/6 Amp single pole two way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 02/ Indoasian Cat No: 800001 or equilent make as specified.
S&F modular switch bell push button type, 1module, 6 Amp single pole complete all as specified and as directed. Make – Legrand cat No: 6734 04 or equivalent make as specified.
S&F bell electric DING DONG type, AC, 230V single pole, 2module complete all as specified and as directed. Make – Legrand cat No: 5734 43 or equivalent make as specified.
S&F modular fan regulator electronic, 2module, stepped type, suitable for ceiling fans of any capacity, pre-wired 120/ 280 volts AC 50Hz supply 100Watt complete all as specified and directed. Make: Legrand cat No: 6734 30 or equivalent others make as specified.
S&F ceiling rose surface bakelite 65 x 25mm dia three terminals (ISI Marked) complete all as specified and directed.
S&F in repair switch piano, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Anchor Cat Part No- 95111/ 14111 or equivalent of makes as specified.
S&F in repair socket outlet, five pin 2in1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor Cat Part No- 14304 / 95304 or equivalent of others makes as specified.
S&F in repair switch piano flush button type 15 Amp single pole one way complete all as specified and as directed. Make – Anchor Cat Part No-14401 or equivalent of makes as specified.
S&Fin repair socket outlet 2 in 1, 3/6 pin, 5 Amp and 15 Amp multipurpose flush type complete all as specified and as directed.. Make – Anchor Cat Part No-14307 or equivalent of makes as specified.
S&F in repair bell electric DING DONG type, AC, 230V single pole complete all as specified and as directed. Make – Anchor Penta -Code-38921 or equivalent make as specified.
S&F angle Lamp holder, insulated body, of PVC/ Polycorbonate with back plate suitable for batten fitting complete all as specified and as directed. Make– Anchor, Code-39797 or equivalent others make as specified.
S&F in repair angle Lamp holder, insulated body, of PVC/ Polycorbonate with back plate suitable for batten fitting complete all as specified and as directed. Make– Anchor, Code-39797 or equivalent others make as specified.
S&F in repair fan regulator electronic, stepped type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed. Make: Anchor, Cat Part No 14501/ 95502 or equivalent others make as specified.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH, PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:- NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs.
2x4 Sqmm + 1x4 Sqmm earth wire with PVC conduit 20mm dia or more
S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn with existing conduit of the following sizes of cable complete all as specified and directed:- NOTE :- (i) Two run of single core FRLSH PVC cable with one run of earth conductor shall be measured as one unit.
2x4 Sqmm + 1x4 Sqmm earth wire
S&F surface mounted LED luminiare, 20 watt with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified and directed. Make :- Shakti, Model: SZSLBMX020 / Crompton, Cat No LCTLN-20-CDL / Havells, Cat No LHEXACP7FN1W020. Note: The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period.
S&F LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive wway, 80 degree luminaire efficiciency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including connecting with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution box to light complete all as specified and directed. Make :- Shakti Cat No SZPCLPM020 / Havells Cat No: LHEXAYP7PN6K020 / Crompton Cat No:TRP-400-20-57-LM-NSR Note :- (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory. (iii) The fiitting should have BIS , CRS No(iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.
S&F recessed mounted LED light fitting 36 watt, 230V, 2'x2', with diffused acrylic cover with all accessories having high lumen output, driver PF>0.98 having over voltage protection upto 400 V, ISI marked square lit panel 2x2 LED luminaire with diffuser 3 core with flexible copper cable PVC insulated of size 1.5 Sqmm complete fixing on existing false ceiling/ POP ceiling/ Armstrong ceiling/ Grid ceiling and required cutting of any type of ceiling to fix the light and making good as peer existing ceiling included on quoted rates, necessary T&P like hydraulic ladders or normal ladders for fixing height upto 4.5 mtrs arranged by contractor on own arrangement is included on quoted rate the light id to be fixed on buildings like Auditorium, Arty mess Gym, Officer transit mess etc complete all as specified and directed Make : Shakti Cat part No: SZRSRMX036 or or equivalent make as specified.
S&F surface mounted LED luminaire. 18 Watt, Trim clipon LED panel round type with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, internally wired through flexible wire connecting with ceiling rose complete fixing on ceiling with necessary drilling and screw materials necessary T&P like hydraulic ladders or normal ladders for fixing height upto 4.5 mtrs arranged by contractor on own arrangement is included on quoted rate the light is to be fixed on buildings like Auditorium, Arty mess, Gym, Officer transit mess etc complete all as specified and directed
M&L for repair and replacement of existing rusted metal circuit box including hylam sheet and switch, sockets, regulators with new 1/2 way-way modular type metal box with and incl decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete and connect existing circuit wiring with new switches & testing complete all as specified and directed Note:- 1 payment witll be done for each module as per rates quoted by the contractor 2.switch/ socket/ regulators will be paid seperately.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed.
Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Disconnecting and taking out old damaged existing main switch/ distribution board of MCB/MCCB of any description from wall with and including all fitting and fixture and making good to disturbed surface of wall/ floor to match with the existing wall/ floor etc complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 240V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps rating having following capacity complete all as specified and directed:-
DB SPN, 4 way Make :-Legrand Cat Part No- 5076 10 or equivalent others make as specified.
DB SPN, 8 way Make :-Legrand Cat Part No- 5076 11 or equivalent others make as specified.
DB SPN, 12 way Make :-Legrand Cat Part No- 5076 12 or equivalent others make as specified.
S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 415V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps rating having following capacity complete all as specified and directed:-
DB TPN, 4 way Make :-Legrand Cat Part No- 6077 15 or equivalent others make as specified.
S&F connecting & testing sheet metal enclsoure double door type for MCCB DB VTPN 4 way with MCCB 4 pole, adjustable thermal & fixed magnetic type 40-63 Amp, 16 KA, 4 pole complete all as specified and directed. Note: Set the MCCB as per builidng load and distribute the load before charge the load.
S&F connecting & testing MCB, 230V with rupturing capacity 10 KA of following capacity complete all as specified and directed:-
MCB 6 to 32Amp, SP 'B' series/ curve, Make :- Legrand, Cat Part No 4024 31 to 4024 36 or equivalent others make as specified.
MCB 6 to 32Amp, SPN, 'C' series/ curve, Make :- Legrand, Cat Part No 4086 17 or equivalent others make as specified.
MCB 6 to 32 Amp, TPN, 'C' series/ curve, Make :- Legrand, Cat Part No 4086 72, 4086 75, 4086 77 to 4086 80 or equivalent others make as specified.
S&F industrial type socket & plug top of 20Amp, 230V, Single Pole and neutral, sheet metal enclosure with and including MCB of ‘C’ series 10KA of following capacity complete all as directed and specified :- Make :- Legrand, Cat Part No- 5078 11 (socket & plug top) or equivalent others make as specified.
Single Pole, 20 Amps, 240 volt. Make :- Legrand, Cat Part No- 4085 93 or equivalent others make as specified.
S&F industrial type socket & plug top of 20Amp, 415V, double Pole, sheet metal enclosure with and including RCB of 16Amp, DP with base face plate capacity complete all as directed and specified. Make :- Legrand, Cat Part No- 5078 20 (socket & plug top) & 4113 24 (RCB) or equivalent others make as specified.
S&F in repair air termination rod single pointed, aluminium rod 2mm dia and 300mm long as specified in SSR Part-I (2009) complete all as specified and as directed
S&F in repair test point terminal box made of gun metal or phosphorous brounze of size 75 x 75 x 25 mm 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed
S&F in repair aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and as directed
S&F Switch flame proof rotary type with termination box inLM6, 16A, single pole 250V complete all as specified and as directed
G S CONSTRUCTIONS
BK CONSTRUCTION
A ONE BUILDERS AND ENGINEERS
TARUN ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .