Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.0 CrAccepted-AOC H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | ₹1.0 Cr | 1 | Accepted-AOC Being Lowest Bidder |
| 2 | 2₹1.0 Cr+₹2.0 L (2.01%)Rejected-Finance | ₹1.0 Cr+₹2.0 L (2.01%) | 2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | 3₹1.1 Cr+₹4.5 L (4.40%)Rejected-Finance | ₹1.1 Cr+₹4.5 L (4.40%) | 3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | 4₹1.1 Cr+₹6.0 L (5.86%)Rejected-Finance | ₹1.1 Cr+₹6.0 L (5.86%) | 4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | 5₹1.1 Cr+₹9.0 L (8.80%)Rejected-Finance M S SRI JAYANTH ASSOCIATES D NO 50 121 18 1 FLAT NO GROUND B SIVA SADAN APARTMENTS BS LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹1.1 Cr+₹9.0 L (8.80%) | 5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
24 Dec 2020, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Special Repairs to Eklavya P - 39 at ENC O Mess, INS Circars, Visakhapatnam
2020_MES_396439_1
82087 / E8
Open Tender
Civil Works
Item Rate
270 days
Visakhapatnam
Class B
Category a i
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹2.1 L
Yes
5 Feb 2021
19 Nov 2020
31 Dec 2020
19 Nov 2020
24 Dec 2020
10 Dec 2020
19 Nov 2020 - 26 Nov 2020
Amount
Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Sub base for flooring complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 8 to 9 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size exceeding 0.36 Sq.m and not exceeding 0.42 Sq.m, 9 to 10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size exceeding 0.36 Sq.m and not exceeding 0.42 Sq.m, 9 to 10 mm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 6mm dia bars at every fourth course of brick work complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for PCC 1:5:10, Type E-2, using 40mm graded stone aggregate as in Sunken Floors etc complete all as specified and as directed.
M & L for preparing surfaces of sunken floor and applying a coat of Brush Bond of M/s. Fosroc Chemicals or equivalent approved water proofing coating as per manufacturer's instructions complete all as required and as directed at site.
M & L for applying Chemical Injection Treatment in the form of Pressure Grouting by drilling 20 mm dia holes, 60 mm deep @ 100 cm grid at bottom floor and all the internal wall surfaces of the sunken slabs of toilet by injecting Cement Slurry mixed with Grout Admixture "CONBEXTRA EP 10" of M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. at 225 Grams for 50 KG of cement complete all as per manufacturers instructions and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:3, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] not exceeding 1.5 Sq.m each and removing to store complete all as specified and as directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, Window, Ventilator Shutters, Sliding or Openable Type, with or without Sash Bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No], Stainless Steel Friction Hinges [1 No] per Window Shutter and 150mm Dia Handles on both sides, Tower bolts, 200 mm Long [2 Nos], Double Action Floor Spring Hydraulically Regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty etc. per Door Shutter complete all as specified and as directed. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Supply only panel inserts of Glass / Particleboard / Gauze / Grills will be measured and paid separately. [c] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless Steel Friction Hinges and fixing only of panel inserts of Glass / Particleboard / Gauze / Grills etc.
S & F Aluminium Powder Coated [Minimum 50 Micron thick] Sections as in Window and Ventilator Shutters, Sliding Type, without Sash Bar, Aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No] per Shutter complete all as specified and as directed. Note: [a] Supply only panel inserts such as Glass / Gauge / Grills will be measured and paid separately. [b] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Locking Arrangement and fixing only of Panel inserts such as Glass / Gauge / Grills etc.
Supply only 5mm thick Figured Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only Stainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm complete all as specified and as directed.
S & F GI water tubing of 15 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F GI water tubing of 40 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, taking down or up steel tubing and connections of any description complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 40 mm bore with iron wheel head, screwed both ends for iron pipe, confirming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Single Lever cast copper alloy, chromium plated Hot and Cold 15mm dia Wall Mixer with provision for both Hand Shower and Overhead Shower complete with 115mm long bend pipe, connecting legs & wall flange complete [excluding hand & overhead shower] as per Jaquar Catalogue No. CON-281KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-047KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-041KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Health Faucet with 1 m long flexible tube, wall hook, non return valve complete as per Jaquar Catalogue No. ALD-577 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Stainless Steel Toilet Paper Holder, Chromium plated, Fancy type complete all as per Jaquar Catalogue No. AHS-1553 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Stainless Steel, Tubular Towel Rail, D Type, 600 mm long between flanges complete all as per Jaquar Catalogue No. ACN-1111SM or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Overhead Shower of 200mm dia with or with out swivel joints fixing to steel pipes Chromium plated, Fancy type complete all as per Jaquar Catalogue No. AHS-1553 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 630 mm X 450 mm including Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe, 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap complete all as specified and as directed.
S & F in repairs Angle Cock, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as per Jaquar Catalogue No. CON-053KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
S & F in repairs 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 75mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 32mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps as in rain water down pipes complete all as specified and as directed.
S & F 75 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 75mm bore PVC [SWR] Multi Floor Trap with grating including jointing with solvent cement complete all as specified and as directed.
M & L for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc. surface finished even and smooth with out using extra cement complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment along external walls below concrete or masonry apron using chemical emulsion @ 2.25 litres per RM by drilling 12 mm dia holes up to 300 mm deep and 300 mm centre to centre including plugging holes complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment of soil under existing floors using chemical emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as specified and as directed.
M & L for providing and injecting chemical emulsion for Post Constructional Anti - termite Treatment at points of contact of wood work by chemical emulsion [in oil or kerosene based solution] @ 0.5 litre per hole by drilling 6 mm dia holes at a downward angle of 45 degrees at 150 mm centre to centre and sealing the same complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 25mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Parapets & Chajjas etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs, Beams, Columns, Fins, Parapets Facias & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of MD land complete all as specified and as directed.
M & L for providing RCC M-20 Design Mix using 20mm graded stone aggregate as in Precast Landings, Cover Slabs [for manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves, Lintels and similar articles with plain faces set in cement mortar 1:6 complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on Wall surfaces complete all as specified and as directed.
M & L for preparing newly plastered Wall / Ceiling surfaces and applying two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer on wall / Ceiling surfaces complete all as specified and as directed.
M & L for preparing newly plastered Ceiling surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer complete all as specified and as directed.
M & L for Complete removal of existing treatment of any description on Ceiling surfaces and applying two coats of Acrylic Washable Distemper over one of alkali resistant primer on Ceiling surfaces complete all as specified and as directed.
M & L for complete removal of existing treatment on Wall / Ceiling surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint complete all as specified and as directed.
M & L for preparation of newly plastered Wall / Ceiling surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint complete all as specified and as directed.
S & F in repairs 10mm thick Calcium Silicate Boards, fixed with screws to Wooden Frames as in Partitions / Shutters / Cupboards / Shelves / Wall Panelling / Door Panels etc. complete all as specified and as directed.
S & F in repairs 18mm thick Plywood, Grade BWR, Type BB, fixed with screws to Wooden Frames as in Partitions / Shutters / Cupboards / Shelves / Wall Panelling / Door Panels etc. complete all as specified and as directed.
S & F 0.9 mm thick Decorative Laminate, Type - 1 of Surface Finish, Colour and Pattern as approved, fixed with approved adhesive as per manufacturer's instructions, complete all as specified and directed.
Taking down and refixing in the same opening shutters of any description not exceeding 1.00 Sq.m each after easing and adjusting complete all as specified and as directed.
S & F 125 mm size, Butt hinges, Stainless Steel, Medium weight, bright polished including fixtures complete all as specified and as directed.
S & F Magnetic Catches with Striking Plate, First quality complete all as specified and as directed.
S & F Stainless Steel Handles 125mm long, Decorative / Designer type suitable for Cupboard shutters complete all as specified and as directed.
S & F Solid PVC door frame of size 100mmX45mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick [Style] consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" Channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement fixing in frame at site as per specification complete all as specified and as directed.
S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 250 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed.
S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
S & F Second Class Hard Wood, plain, solid, straight Chowkats and Frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
S & F Factory made, 40 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F 4 mm thick, Veneered Decorative Plywood, Grade - I [with BWR resin] with Decorative Face Veneers on One Face, fixed with glue and including French polishing one or more coats on surfaces of any description, including cleaning and preparing the surface including a coat of wood filler complete all as specified and as directed.
S & F second class hard wood plain, Designer fillets / Beading, square, rectangular or triangular in section, wrought, secured with screws around Chowkats, cross sectional area exceeding 6 Sq.cm and not exceeding 13 Sq.cm complete all as specified and as directed.
S & F Factory made, 35mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [b] and fitted to Chowkats complete all as specified and as directed.
S & F Brass Sliding Door Bolt with sand or die-cast brass hasp, staple [Bolt Type] of size 300 mm and fixing bolt with rolled or drawn brass bolts complete all as specified and as directed.
S & F 125 mm size, Butt hinges, extruded Brass, with mild steel hinge pin, bright polished, Type B-12 including fixtures complete all as specified and as directed.
S & F Brass Polished Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed.
S & F in repairs Decorative type Stainless Steel Curtain Rod of 25 mm dia including PVC rings @ 100 mm centre to centre and Decorative type Stainless Steel Globe type Brackets of size suitable to 25mm dia curtain rod complete all as specified and as directed.
M & L for French polishing one or more coats on surfaces of any description, surfaces over 10cm width or girth including cleaning and preparing the surface including a coat of wood filler on old work complete all as specified and as directed.
S & F Mild Steel work conforming to Fe - 290, Grade E-165, as in framed work such as Grills, Gratings, Ladders etc with ends of bars shouldered and/or riveted, or forged into spikes, framed Guard Bars, Barred Iron Doors, Ladders, framed Balusters, Walk Ways, Railings, framework of Water Tanks and similar work complete all as specified and as directed.
S & F Brass barrel Tower Bolt of size 150 mm size with cast or sheet barrel and rolled or cast bolts complete all as specified and as directed.
Demolition of existing Jallies of any description, making good the disturbed surfaces to match with existing in Cement Mortar 1:3 and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
M & L for preparation of old painted wood and wood based surfaces of any description not other wise described over 10 cm width or girth and applying One coat of synthetic enamel paint complete all as specified and directed.
S & F in repairs Stainless Steel Railing made with Stainless Steel Pipes of wall thickness not less than 1.6mm, of Grade AISI 304, standard quality, bright polish finish, using 50mm dia pipes for hand rail, 25mm dia pipes for vertical supports / balusters and 25mm dia pipes as in tie bars in three layers, SS tubes shall be welded at the turnings and junctions, welded portions shall be completely grinded and brought to bright and smooth finish including all bends, elbows, making holes in the floor / steps, grouting with epoxy to achieve full strength of railing complete all as specified and as directed.
M & L for Marble Stone Slabs of 18 to 20 mm thick of Green Colour as in Flooring, Treads and Risers of Steps, Landings of Staircase etc. with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, slabs shall be of design / pattern as directed, including inlays, borders, margins, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious joint filler to match the shade of the Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: Single stone slab shall be used for entire width of Steps, Risers & Landing etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded. The edges of the treads and landings shall also be provided with three Nos of grooves.
M & L for Granite Stone Slabs of 18 to 20 mm thick of Colour Mexican Red / Ruby Red / Z Black / Pearl Black as in Steps, Jambs, Pillars, Window Cills, Cooking Platform etc. and the like with machine cut edges, Table rubbed and prepolished to smooth mirror finish all to required sizes, granite stone slabs shall be of design / pattern as directed, including inlays, borders, margins in two or more colours / shades, designs / patterns of stone slabs, set and bedded with grey cement [slurry] and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite Slabs including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: Single stone slab shall be used for entire height of Steps, Jambs, Pillars, Window Cills, Cooking Platform etc. and joints shall match with the flooring
Taking down carefully copper / aluminium point wiring [light, fan, socket or power] complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good the disturbed surfaces all as per existing complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 97 above but for One Light Point controlled by Two Nos. of, Two way Switches complete all as specified and as directed.
All as per Serial Item No. 97 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 97 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 97 above but for one SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket, with 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 and including 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 as earth continuity conductor and connecting to earth dolly complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, Two Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Ceiling Rose, Surface Bakelite, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed.
S & F Switch, Modular Type, One Module, Single Pole, One Way, 16 Amps, 230 Volts complete all as specified and as directed.
S & F Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F Electronic Fan Regulator, Stepped Type, Modular Type, One Module, 120 W, AC, 230 Volts, Single Pole complete all as specified and as directed.
S & F in repairs SP & N Enclosure with 2 Pole and Earth Metal Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, 240 Volts complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 3 runs of 2.5 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit.
M & L for Sub main wiring with 4 runs of single core 10 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 10 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor including taking down old sub main wiring of any description and making good disturbed surface complete all as specified and as directed. Note: 5 runs of 10 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
M & L for Taking down Ceiling Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, replacement of Spares such as Capacitor 2.5 Mfd, Bearings, Shaft Bushes, Capacitor, Cotter Pin, Clamps, Rubber Bushes, Nuts & Bolts etc. as required and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
Taking down Exhaust Fan of any description from its position and refixing the same after repairs to buildings, at same place or at new place including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm, cleaning, greasing etc and replacement of Spares such as Capacitor 4 Mfd, Bearings, Shaft Bushes, Condenser, Rubber Bushes, Nuts & Bolts etc. and also including cleaning, greasing and spray painting with two coats of synthetic enamel paint of approved colour over a coat of zinc chrome primer after filling cavities with filler and complete all as specified and directed.
S & F MCCB, TP, 160 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F in repairs MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB, SPN, 40 to 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, TPN, 63 Amps, 415 Volts, 50 Hz complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F in repairs Busbar Trunking System of 26 Metres long, 800 Amps, Sandwich type, Silver flashed, Bimetal Copper Contact, Aluminium Busway [3L + N + PE] with original Mylar Insulation from DuPont, 100 Natural, 100 kA for 1 Sec, 50% Integral Earth, Dual Housing [1.6mm thick Aluminium + 1.6mm thick Electro Galvanised Steel], Class "F" Insulation, epoxy powder coated including all necessary accessories, 6 Nos. of Tap off Boxes, One End Terminals, Spring Supports etc. complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.
S & F in repairs Aluminium Strip of size 25 X 3 mm, fixed to walls / columns / beams etc with Saddles or porcelain blocks of 10mm thick spaced at 1.00m centre to centre including making grooves and fixing with brass screws etc. for roof conductors and down conductors above ground complete all as specified and as directed. Note: Hylam sheet block shall be in two pieces each 10mm thick, one fixed to base with brass screws and the other fixed over it with brass screws after fixing aluminium strip in the groove provided.
S & F in repairs Earth continuity Conductor or main earthing lead made of GI Strip of size 25 X 4mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
S & F in repairs Single Pointed Air Termination Aluminium Rod, 12 mm dia and 300 mm long including necessary fasteners fixed for Lighting Protection with necessary connections to earthing etc complete all as specified and as directed.
S & F in repairs Test Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
S & F in repairs Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F in repairs TV Socket / Outlet, Co-Axial, Deluxe, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F Heavy duty PVC Conduit, 20 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable or LAN Cable etc. complete all as specified
S & F Bell Push, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed.
S & F Bell, Ding Dong / Multi Music Type, AC, 230 Volts, Single Pole complete all as specified and as directed.
RAJESH ENTERPRISES
P SRINIVASA RAO
N Sydeswara Rao
SRI JAYANTH ASSOCIATES
D NARAYANA REDDY CONSTRUCTIONS
ANIL KUMAR BISWAL
Mavee Syndicate
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .