CAPTAIN RUPESH VENUGOPAL
FLEET MAINTENANCE UNIT (MBI), NAVAL DOCKYARD, MUMBAI 400001
REPAIR RATE CONTRACT (RRC) FOR UNDERTAKING REPAIR/ MAINTENANCE OF ENGINEERING CONTROLS AND INSTRUMENTATION ONBOARD INDIAN NAVAL SHIPS
2022_NAVY_535624_1
FMU/344/NECTAR INSTRUMENTATION
Single
Marine Services
Turn-key
365 days
FLEET MAINTENANCE UNIT MUMBAI
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
PCDA NAVY
Exempted
29 Jul 2022
4 Jul 2022
12 Jul 2022
4 Jul 2022
11 Jul 2022
4 Jul 2022
4 Jul 2022 - 10 Jul 2022
Amount
CHARGES FOR 1ST YEAR
SERVICE CHARGES
Service Charges for EHM trial per ship for 03 days
Additional charges for the team if required for EHM trial
Charges for one training session for 02 days for one class of ship
Service Charges to attend the services other than mumbai for first day
Additional per day cost other than mumbai
TANK LEVEL AND FLOOD SENSORS
Diagnostic visit (which includes the following Services) - Check physical condition - Wiring check (Complete health check of cable from sensor to JB including insulation checks) - Functional/operational checks - Simulation - Locating faults - Serviceable / BER certificate - Refurbishment scope
Servicing of defective sensors/ renewal of cabling (which includes the following)
Removal of defective sensors and placing a blank to cover the opening (applicable only for tank level sensors0 along with securing of neked cables
Services for removal
Services for Blanking
Carriage of sensor for repairs - Protective packaging and transport from FMU/Ship to & fro Workshop/Office for refurbishment
Repairs / Renewal of cabling • Services - Removal/renewal of cables - Disconnection from sensor & JB - Removal of old cables - Re- laying of new cables - Securing of new cables - Refurbishment of cable tallies - Refurbishment of grounding cables
Repair of Sensors
• Services - Cost for carrying out major repairs / including change of module
Services – Installation & STW onboard includes - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
PRESSURE AND DIFFRENTIAL PRESSURE SENSORS
Diagnostic visit (which includes the following Services) - Pressure sensor - Check physical condition - Wiring check (Complete health check of cable from sensor to JB including insulation checks) - Functional/operational check - Simulation - Locating faults - Serviceable / BER certificate - Refurbishment work plan
Diagnostic visit (which includes the following Services) - Diffrential Pressure sensor - Check physical condition - Wiring check (Complete health check of cable from sensor to JB including insulation checks) - Functional/operational check - Simulation - Locating faults - Serviceable / BER certificate - Refurbishment work plan
Servicing of defective sensors / renewal of cabling (which includes the following
Removal of defective sensor and placing a blank to cover the opening alongwith securing of naked cables
Services for removal of sensor
Relative / Absolute Pressure
Differential Pressure
Smart Submersible fitted on Avcat Tanks
Services for blanking of sensor
Relative / Absolute Pressure
Differential Pressure
Smart Submersible fitted on Avcat Tanks
Carriage of sensor for repairs - Protective packaging and transport from FMU / Ship to & fro Workshop/Office for refurbishment
Renewal of cabling • Services - Removal/renewal of cables - Disconnection from sensor & JB - Removal of old cables - Re- laying of new cables - Securing of new cables - Refurbishment of cable tallies - Refurbishment of grounding cables
• Services for Soldering and securing cable connector
Repairs of sensors
• Services - Cost for carrying out major repairs if possible includes changing electronics modules
Services in Installation & STW onboard includes - Relative / Absolute Pressure - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
Services in Installation & STW onboard includes - Differential Pressure - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
Services in Installation & STW onboard includes - Smart Submersible Sensor - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
TEMPRATURE SENSOR
Diagnostic visit (which includes the following Services) - Check physical condition - Wiring check (Complete health check of cable from sensor to JB including insulation checks) - Functional/operational checks - Simulation - Locating faults - Serviceable / BER certificate - Refurbishment scope
Servicing of defective sensors / renewal of cabling (which includes the following
Removal of defective sensor and placing a blank to cover the opening along with securing of naked cables
Services – Removal of sensor
Services for Blanking of sensor
Carriage of sensor for repairs - Protective packaging and transport from FMU/Ship to & fro Workshop/Office for refurbishment
Repairs / Renewal of cabling • Services - Removal/renewal of cables - Disconnection from sensor & JB - Removal of old cables - Re- laying of new cables - Securing of new cables - Refurbishment of cable tallies - Refurbishment of grounding cables
Repairs of sensors
• Services - Cost for carrying out major repairs including change module
Services – Installation & STW onboard includes - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
Temperature Measurement and Indicating Systems
Services - Removal of PTR
Services - Securing of onboard connectors
Services - Serviceability checks onboard
Serviceable/BER Certificate
Service - Refurbishment at firms premises
Services - Cable heath checks and insulation check per PTR from PTR to 1st Junction box
Services - Functionality checks and calibration
Services - Installation and commissioning
KC429 JUNCTION BOX
Services – Disconnection and Removal of KC429
Services - securing of onboard connectors
Services - Serviceability checks onboard / ashore
Serviceable/BER Certificate
Service - Refurbishment in firms premises
Services - Cable heath checks and insulation check (per KC429) - from KC429 to 1st Junction box - of KC429 cable and connector
Services - Functionality checks and calibration w.r.t OEM Standards
Services - Installation and STW
functionality checks, refurbishment and replacement of following equipments
- Removal
- Serviceability checks
- BER certificate
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector each
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
- Removal & cable securing
- Serviceability checks
- BER certificate / report
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
- Removal & cable securing
- Serviceability checks
- BER certificate / report
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
- Removal & Blanking
- Serviceability checks
- BER certificate / report
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
- Removal & Blanking
- Serviceability checks
- BER certificate / report
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
SHAFT RPM SYSTEM
REMOVAL OF
Sensor
Convertor
Indicator (each)
Serviceability checks (cold) of
· Sensor
· Intermediate converter unit
· Indicators
· Serviceable/BER certificate / report (each)
Refurbishment of
· Sensor
· Converter
· Indicator
Calibration of
· Converter with NABL Certificate
· Indicator with NABL Certificate
System cable health checks from
· Sensor to converter,
· Converter to indicators
Installation
· Sensor
· Convertor
· Indicator
RPM System (STW)
MKY PRESSURE GAUGES
- Removal and blanking
- Serviceability checks
- Serviceable/BER Certificate
- Repairs
- Calibration with NABL Certificate
Installation
LIMIT SWITCHES
- Insitu Cold checks
- Serviceable/BER Certificate
- Removal of switches
- Cable health & Insulation checks from switch to 1st Jb
- Refurbishment of Switch
Installation and STW of Switch
HANGER DOOR LIMIT SWITCHES
- Insitu Cold checks
- Serviceable/BER Certificate
- Removal of switches
- Cable health & Insulation checks from switch to 1st Jb
- Refurbishment of Switch
Installation and STW of Switch
PУM-1 (MINIMUM LEVEL RELAY)
Level Sensor
- Insitu Cold checks for sensor
- Serviceable/BER Certificate
- Removal of sensor
- Cable health & Insulation checks from sensor to relay
- Functionality checks of sensor
- Installation and STW of sensor
Level Relay box
- Insitu cold checks of relay unit
- Serviceable/BER Certificate
- Removal of Relay Box
- Refurbishment of Rely Box
- Connector (4 & 5 pin m/f) each
- Calibration/Tuning
- Cable health & insulation checks from Relay box to 1st JB
- Installation and STW of Relay unit
GTG RPM Measurement and Indication System
Tachogenerator
· Removal of tacho
· Serviceability checks
· Serviceable/BER Certificate
· Refurbishment
· Calibration checks
· Cable health checks
· Installation and STW
Indicator
· Removal of indicator
· Serviceability checks
· Serviceable/BER Certificate
· Refurbishment
· Installation and STW
Converter Unit
· Removal of Unit
· Serviceability checks
· Serviceable/BER Certificate
· Refurbishment
· Calibration checks
· Cable health checks
Installation and STW
CHARGES FOR CONSUMABLE SPARES
Tank Level and Flood Sensors
Material Cost of new 5 core cable as per IN specs
Material List for repairs
- Material -Connecting terminals
- Material -Connecting screws
- Material -Gaskets
Material for changing Electronics module
PRESSURE AND DIFFERENTIAL PRESSURE SENSORS
Cost of new 4 core cable as per IN specs
Cost of new Connector
Material List for repairs
- Material –Connectors for sensor
- Material -Connecting screws
- Material -Gaskets
Material for changing Electronics module
Absolute/relative sensor
Differential sensor
Smart Submersible sensor
Temperature sensors
Material List for repairs
- Material -Connecting terminals
- Material -Connecting screws
- Material -Gaskets
Material for changing sensing element
Temperature Measurement and Indication Systems
Connector/ cable connectors
Gasket
Grounding cable
KC 429 JUNCTION BOX
Connector along with cable
cable glands
Lid gasket
Grounding cable
CHARGES FOR SPARES
LAVEL SENSORS
ASL Level switch, Alum, 1"GM, 114 mm,PG13, relay
ASL Level switch, AISI, DN25, 400 mm, PG9, current
ASL Level switch, AISI, DN25, 430 mm, PG9, current
ASL Level switch, AISI, DN25, 680 mm, PG9, current
ASL Level switch, AISI, DN25, 1300 mm, PG13, relay
ASL Level switch, AISI, DN25, 200 mm, PG13, relay
ASL Level switch, AISI, DN25, 350 mm, PG13, relay
ASL Level switch, AISI, DN25, 400 mm, PG13, relay
ASL Level switch, AISI, DN25, 480 mm, PG13, relay
ASL Level switch, AISI, DN25, 160 mm, PG9, current, EX
ASL Level switch, AISI, DN25, 690 mm, PG9, current, EX
ASL Level switch, AISI, DN25, 114 mm, PG13, relay
ASL Level switch, AISI, 1"GM, 114 mm, PG13, relay
ASL Level switch, AISI, 1"GM, 114 mm, PG9, current, EX
ASL Level switch, Alum, DN25, 114 mm,PG13, relay
ASL Level switch, AISI, 1"GM, 114 mm, PG9A, relay, CABLE 5M
ASL Level switch, AISI, 1"GM, 114 mm, PG9A, relay, CABLE 5M
ASL Level switch, AISI, DN25, 200 mm, PG9A, relay, CABLE 5M
ASL Level switch, AISI, DN25, 114 mm, PG9A, relay, CABLE 5M
PRESSURE AND DIFFERENTIAL PRESSURE SENSORS
Absolute Pressure Transmitter,0/1.6 kg/cm2 ABS,M22x1,5t,MIL
Relative Pressure Transmitter, 0/4 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/6 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/10 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/16 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/25 kg/cm2, M22x1,5t,MIL
SMART Relative Pressure Transmitter 0-2.5kg/cm2, M20x1,5t,EX
Relative Pressure Transmitter, 0/60 kg/cm2, M27X1,5,MIL
Relative Pressure Transmitter, 0/100 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/160 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/250 kg/cm2, M27X1,5,MIL
Differential Pressure Transmitter, 40 mbar, M22X1,5t,MIL
Differential Pressure Transmitter, 2,5 Kg/cm2, M22X1,5t,MIL
SMART Submersible sensor,0/4mWC,1”GM,M PG13 DN65,L950,EX
SMART Submersible sensor,0/4mWC,1”GM,M PG13 DN65,L1400,EX
SMART Submersible sensor,0/4mWC,1”GM,M PG13 DN65,L1600,EX
SMART Submersible sensor,0/4mWC,1”GM,M PG13 DN65,L2050,EX
SMART Submersible Transmitter, 0/2,5mWC, 1”GM,Cable-10m
TEMPERATURE MONITORING AND CONTROLLING SYSTEMS
PTR -012 Pulse Regulator Temperature
Measuring Unit No.1
Amplifier Unit No.2
Power Supply Unit No.3
Galvanic Isolation Unit No.4
Correction Unit No. 5
Amplifier Unit No. 6
Setters Unit No. 7
Signal Unit No. 8
Adjustment Unit No.9
Junction Box KC-429M1
TEMPERATURE SENSORS TYPE TC(P) AND TXA
THERMO ELECT. CONVERTER
TXA-1172 5(TS)2-821-679-66-01
THERMAL CONVERTER TC(P)-1-8040 B(P) 004-47, ЮВма.405211.004-47
Thermocouple transducer(0-600)
TEMPERATURE TRANSDUCER THERMOELECTRIC TXA-1368 VERSION
TCП-Z8040 5Ц2.821.439-01
RESISTANCE THERMOMETER
Additional Temperature Sensors
Thermal converter TCП-8040
Resistence thermometer
GT RELATED ITEMS/EQUIPMENT INDIGENISED / LOCALLY DEVELOPED
SHAFT RPM SYSTEM
MKY PRESS. GAUGES
LIMIT SWITCHES
HANGER DOOR LIMIT SWITCHES
GTG RPM Measuring & Indicating System
CHARGES FOR 2ND YEAR
SERVICE CHARGES
Service Charges for EHM trial per ship for 03 days
Additional charges for the team if required for EHM trial
Charges for one training session for 02 days for one class of ship
Service Charges to attend the services other than mumbai for first day
Additional per day cost other than mumbai
TANK LEVEL AND FLOOD SENSORS
Diagnostic visit (which includes the following Services) - Check physical condition - Wiring check (Complete health check of cable from sensor to JB including insulation checks) - Functional/operational checks - Simulation - Locating faults - Serviceable / BER certificate - Refurbishment scope
Servicing of defective sensors/ renewal of cabling (which includes the following)
Removal of defective sensors and placing a blank to cover the opening (applicable only for tank level sensors0 along with securing of neked cables
Services for removal
Services for Blanking
Carriage of sensor for repairs - Protective packaging and transport from FMU/Ship to & fro Workshop/Office for refurbishment
Repairs / Renewal of cabling • Services - Removal/renewal of cables - Disconnection from sensor & JB - Removal of old cables - Re- laying of new cables - Securing of new cables - Refurbishment of cable tallies - Refurbishment of grounding cables
Repair of Sensors
• Services - Cost for carrying out major repairs / including change of module
Services – Installation & STW onboard includes - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
PRESSURE AND DIFFRENTIAL PRESSURE SENSORS
Diagnostic visit (which includes the following Services) - Pressure sensor - Check physical condition - Wiring check (Complete health check of cable from sensor to JB including insulation checks) - Functional/operational check - Simulation - Locating faults - Serviceable / BER certificate - Refurbishment work plan
Diagnostic visit (which includes the following Services) - Diffrential Pressure sensor - Check physical condition - Wiring check (Complete health check of cable from sensor to JB including insulation checks) - Functional/operational check - Simulation - Locating faults - Serviceable / BER certificate - Refurbishment work plan
Servicing of defective sensors / renewal of cabling (which includes the following
Removal of defective sensor and placing a blank to cover the opening alongwith securing of naked cables
Services for removal of sensor
Relative / Absolute Pressure
Differential Pressure
Smart Submersible fitted on Avcat Tanks
Services for blanking of sensor
Relative / Absolute Pressure
Differential Pressure
Smart Submersible fitted on Avcat Tanks
Carriage of sensor for repairs - Protective packaging and transport from FMU / Ship to & fro Workshop/Office for refurbishment
Renewal of cabling • Services - Removal/renewal of cables - Disconnection from sensor & JB - Removal of old cables - Re- laying of new cables - Securing of new cables - Refurbishment of cable tallies - Refurbishment of grounding cables
• Services for Soldering and securing cable connector
Repairs of sensors
• Services - Cost for carrying out major repairs if possible includes changing electronics modules
Services in Installation & STW onboard includes - Relative / Absolute Pressure - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
Services in Installation & STW onboard includes - Differential Pressure - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
Services in Installation & STW onboard includes - Smart Submersible Sensor - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
TEMPRATURE SENSOR
Diagnostic visit (which includes the following Services) - Check physical condition - Wiring check (Complete health check of cable from sensor to JB including insulation checks) - Functional/operational checks - Simulation - Locating faults - Serviceable / BER certificate - Refurbishment scope
Servicing of defective sensors / renewal of cabling (which includes the following
Removal of defective sensor and placing a blank to cover the opening along with securing of naked cables
Services – Removal of sensor
Services for Blanking of sensor
Carriage of sensor for repairs - Protective packaging and transport from FMU/Ship to & fro Workshop/Office for refurbishment
Repairs / Renewal of cabling • Services - Removal/renewal of cables - Disconnection from sensor & JB - Removal of old cables - Re- laying of new cables - Securing of new cables - Refurbishment of cable tallies - Refurbishment of grounding cables
Repairs of sensors
• Services - Cost for carrying out major repairs including change module
Services – Installation & STW onboard includes - Removal of blanking - Re-fitment of Sensor - Restoring electrical Connectorisation - Securing grounding cable - STW - Test reports/calibration certificate
Temperature Measurement and Indicating Systems
Services - Removal of PTR
Services - Securing of onboard connectors
Services - Serviceability checks onboard
Serviceable/BER Certificate
Service - Refurbishment at firms premises
Services - Cable heath checks and insulation check per PTR from PTR to 1st Junction box
Services - Functionality checks and calibration
Services - Installation and commissioning
KC429 JUNCTION BOX
Services – Disconnection and Removal of KC429
Services - securing of onboard connectors
Services - Serviceability checks onboard / ashore
Serviceable/BER Certificate
Service - Refurbishment in firms premises
Services - Cable heath checks and insulation check (per KC429) - from KC429 to 1st Junction box - of KC429 cable and connector
Services - Functionality checks and calibration w.r.t OEM Standards
Services - Installation and STW
functionality checks, refurbishment and replacement of following equipments
- Removal
- Serviceability checks
- BER certificate
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector each
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
- Removal & cable securing
- Serviceability checks
- BER certificate / report
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
- Removal & cable securing
- Serviceability checks
- BER certificate / report
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
- Removal & Blanking
- Serviceability checks
- BER certificate / report
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
- Removal & Blanking
- Serviceability checks
- BER certificate / report
- Refurbishment
- Calibration with NABL Certificate
- Connector/cable connector
- Cable heath & insulation checks from sensor to 1st JB
Installation & STW
SHAFT RPM SYSTEM
REMOVAL OF
Sensor
Convertor
Indicator (each)
Serviceability checks (cold) of
· Sensor
· Intermediate converter unit
· Indicators
· Serviceable/BER certificate / report (each)
Refurbishment of
· Sensor
· Converter
· Indicator
Calibration of
· Converter with NABL Certificate
· Indicator with NABL Certificate
System cable health checks from
· Sensor to converter,
· Converter to indicators
Installation
· Sensor
· Convertor
· Indicator
RPM System (STW)
MKY PRESSURE GAUGES
- Removal and blanking
- Serviceability checks
- Serviceable/BER Certificate
- Repairs
- Calibration with NABL Certificate
Installation
LIMIT SWITCHES
- Insitu Cold checks
- Serviceable/BER Certificate
- Removal of switches
- Cable health & Insulation checks from switch to 1st Jb
- Refurbishment of Switch
Installation and STW of Switch
HANGER DOOR LIMIT SWITCHES
- Insitu Cold checks
- Serviceable/BER Certificate
- Removal of switches
- Cable health & Insulation checks from switch to 1st Jb
- Refurbishment of Switch
Installation and STW of Switch
PУM-1 (MINIMUM LEVEL RELAY)
Level Sensor
- Insitu Cold checks for sensor
- Serviceable/BER Certificate
- Removal of sensor
- Cable health & Insulation checks from sensor to relay
- Functionality checks of sensor
- Installation and STW of sensor
Level Relay box
- Insitu cold checks of relay unit
- Serviceable/BER Certificate
- Removal of Relay Box
- Refurbishment of Rely Box
- Connector (4 & 5 pin m/f) each
- Calibration/Tuning
- Cable health & insulation checks from Relay box to 1st JB
- Installation and STW of Relay unit
GTG RPM Measurement and Indication System
Tachogenerator
· Removal of tacho
· Serviceability checks
· Serviceable/BER Certificate
· Refurbishment
· Calibration checks
· Cable health checks
· Installation and STW
Indicator
· Removal of indicator
· Serviceability checks
· Serviceable/BER Certificate
· Refurbishment
· Installation and STW
Converter Unit
· Removal of Unit
· Serviceability checks
· Serviceable/BER Certificate
· Refurbishment
· Calibration checks
· Cable health checks
Installation and STW
CHARGES FOR CONSUMABLE SPARES
Tank Level and Flood Sensors
Material Cost of new 5 core cable as per IN specs
Material List for repairs
- Material -Connecting terminals
- Material -Connecting screws
- Material -Gaskets
Material for changing Electronics module
PRESSURE AND DIFFERENTIAL PRESSURE SENSORS
Cost of new 4 core cable as per IN specs
Cost of new Connector
Material List for repairs
- Material –Connectors for sensor
- Material -Connecting screws
- Material -Gaskets
Material for changing Electronics module
Absolute/relative sensor
Differential sensor
Smart Submersible sensor
Temperature sensors
Material List for repairs
- Material -Connecting terminals
- Material -Connecting screws
- Material -Gaskets
Material for changing sensing element
Temperature Measurement and Indication Systems
Connector/ cable connectors
Gasket
Grounding cable
KC 429 JUNCTION BOX
Connector along with cable
cable glands
Lid gasket
Grounding cable
CHARGES FOR SPARES
LAVEL SENSORS
ASL Level switch, Alum, 1"GM, 114 mm,PG13, relay
ASL Level switch, AISI, DN25, 400 mm, PG9, current
ASL Level switch, AISI, DN25, 430 mm, PG9, current
ASL Level switch, AISI, DN25, 680 mm, PG9, current
ASL Level switch, AISI, DN25, 1300 mm, PG13, relay
ASL Level switch, AISI, DN25, 200 mm, PG13, relay
ASL Level switch, AISI, DN25, 350 mm, PG13, relay
ASL Level switch, AISI, DN25, 400 mm, PG13, relay
ASL Level switch, AISI, DN25, 480 mm, PG13, relay
ASL Level switch, AISI, DN25, 160 mm, PG9, current, EX
ASL Level switch, AISI, DN25, 690 mm, PG9, current, EX
ASL Level switch, AISI, DN25, 114 mm, PG13, relay
ASL Level switch, AISI, 1"GM, 114 mm, PG13, relay
ASL Level switch, AISI, 1"GM, 114 mm, PG9, current, EX
ASL Level switch, Alum, DN25, 114 mm,PG13, relay
ASL Level switch, AISI, 1"GM, 114 mm, PG9A, relay, CABLE 5M
ASL Level switch, AISI, 1"GM, 114 mm, PG9A, relay, CABLE 5M
ASL Level switch, AISI, DN25, 200 mm, PG9A, relay, CABLE 5M
ASL Level switch, AISI, DN25, 114 mm, PG9A, relay, CABLE 5M
PRESSURE AND DIFFERENTIAL PRESSURE SENSORS
Absolute Pressure Transmitter,0/1.6 kg/cm2 ABS,M22x1,5t,MIL
Relative Pressure Transmitter, 0/4 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/6 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/10 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/16 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/25 kg/cm2, M22x1,5t,MIL
SMART Relative Pressure Transmitter 0-2.5kg/cm2, M20x1,5t,EX
Relative Pressure Transmitter, 0/60 kg/cm2, M27X1,5,MIL
Relative Pressure Transmitter, 0/100 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/160 kg/cm2, M22x1,5t,MIL
Relative Pressure Transmitter, 0/250 kg/cm2, M27X1,5,MIL
Differential Pressure Transmitter, 40 mbar, M22X1,5t,MIL
Differential Pressure Transmitter, 2,5 Kg/cm2, M22X1,5t,MIL
SMART Submersible sensor,0/4mWC,1”GM,M PG13 DN65,L950,EX
SMART Submersible sensor,0/4mWC,1”GM,M PG13 DN65,L1400,EX
SMART Submersible sensor,0/4mWC,1”GM,M PG13 DN65,L1600,EX
SMART Submersible sensor,0/4mWC,1”GM,M PG13 DN65,L2050,EX
SMART Submersible Transmitter, 0/2,5mWC, 1”GM,Cable-10m
TEMPERATURE MONITORING AND CONTROLLING SYSTEMS
PTR -012 Pulse Regulator Temperature
Measuring Unit No.1
Amplifier Unit No.2
Power Supply Unit No.3
Galvanic Isolation Unit No.4
Correction Unit No. 5
Amplifier Unit No. 6
Setters Unit No. 7
Signal Unit No. 8
Adjustment Unit No.9
Junction Box KC-429M1
TEMPERATURE SENSORS TYPE TC(P) AND TXA
THERMO ELECT. CONVERTER
TXA-1172 5(TS)2-821-679-66-01
THERMAL CONVERTER TC(P)-1-8040 B(P) 004-47, ЮВма.405211.004-47
Thermocouple transducer(0-600)
TEMPERATURE TRANSDUCER THERMOELECTRIC TXA-1368 VERSION
TCП-Z8040 5Ц2.821.439-01
RESISTANCE THERMOMETER
Additional Temperature Sensors
Thermal converter TCП-8040
Resistence thermometer
GT RELATED ITEMS/EQUIPMENT INDIGENISED / LOCALLY DEVELOPED
SHAFT RPM SYSTEM
MKY PRESS. GAUGES
LIMIT SWITCHES
HANGER DOOR LIMIT SWITCHES
GTG RPM Measuring & Indicating System
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .