Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹39.7 L
EMD Value
₹79,442
Closing Date
28 Oct 2026, 11:00 am
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer Mech and Hosp Division Udhampur
Executive Engineer Mech and Hosp Division Udhampur
Upgradation and Strengthening of Govt. Fruit Plant Nursery Ramnagar by way of Installation of Roof Top Screen House Cum Shade Net House of size 30mx10m at GFPN Ramnagar
2026_PWDJK_328147_1
MHDU/TS/2026-27/71
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
90 days
Ramnagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Mech and Hosp Division Udhampur
₹79,442
14 Oct 2026
14 Oct 2026
28 Oct 2026
14 Oct 2026
28 Oct 2026
14 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthwork in excavation by manual means over area for levelling purpose including disposal of excavated earth up to 1m from cutting edge and should be disposed in near-by all kind of soil.
Side wall foundation= 87mx0.6mx0.3m
Center Path = (0.65mx30mx0.10m)
Water Tank = 2.13mx2.13mx2.13m
Total = 27.12 Cum
Area to be excavated keeping in view the earthquake resistance for which an MS mesh (10 mm) is to be provided in the base foundation of the plinth | 27.12 | Cum | 100 | ₹2,712 |
| 2 | Providing and laying of cement concrete (1:5:10) using 40mm nominal size Nallah stone.
Side wall foundation= 87mx0.3mx0.076m
Center Path = (0.65mx30mx0.076m)
Water Tank = 2.13mx2.13mx0.076m
Total = 3.68 Cum | 3.68 | Cum | 101 | ₹371.68 |
| 3 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size
Side wall foundation= 87mx0.3mx1m
Center Path = (0.65mx30mx1m)
Water Tank = 4(2.13mx2.13mx0.23m) + 2(2.13mx2.13mx0.15m)
Total = 51.13 Cum | 51.13 | Cum | 102 | ₹5,215.26 |
| 4 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
10mm bar for Side wall foundation tie beam
10mm bar of length for Tank Floor Raft and Slab
10mm bar for Tank Walls
8mm bar of length for Rings of Tie beam
Total = 573.58Kg | 573.58 | Kg | 103 | ₹59,078.74 |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for: 4.6.1 Foundations, footings, bases for columns
Area = 2x(87mx1m) + 5(1.82mx1.82m) = 190.56 Sqm | 190.56 | Sqm | 104 | ₹19,818.24 |
| 6 | 12 mm cement plaster to plinth wall of mix 1:3 (1 cement: 3 fine sand)
Area = 5(1.82mx1.82m) + 2(87mx0.05m) = 25.26 Sqm | 25.26 | Sqm | 105 | ₹2,652.3 |
| 7 | Cement concrete flooring and foundation as per the site requirement 1:2:4 (1 cement: 2 sand: 4 graded stone finished with a floating coat of neat cement including cement slurry but excluding the cost of noising of steps Complete
50 mm thick 20 mm size stone aggregate.
Floor area = 1.82mx1.82m = 3.31 Sqm | 3.31 | Sqm | 106 | ₹350.86 |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead up to 50m and lift up to 1.5m.
Quantity = 2(87mx0.45mx.07m) + 4x(1.82mx1.82mx0.07m) = 6.408 Cum | 6.41 | Cum | 107 | ₹685.66 |
| 9 | Hot Dipped G.I. work for Net Structure Screen House 30 m x 10m with buffer room 3m x 2.5m GI Pipe ISI Standard confirming to IS 1239 B Class, Thickness 2mm, GI coat ISI standard confirming to IS 4736-1968/ISO65-1973.
For Net Structure Screen House of Size (Working area): 30m x10mx4mx 2.5 m (L x W x CH: SH). :- GI (60mmx60mmx2mm), (50mmx50mmx2mm) and (38mmx38mmx2mm) is of ISI standard IS 1239 class B anti-corrosive, humidity resistant pipe with IS 4736-1968/ISO 65-1973 Zinc coat as approved for maximum J&K, India wind/snow load conditions, structural trusses be provided for absolute strength wind load 160km/hr (BL3-P rigid, wind resistant frame.) Reinforced rigid frame walls and ceiling sealed with internal shell.
Trusses (50mmx50mmx2mm):- 15Nos. (27 meter each),Centre truss support(38mmx38 mx2mm):- 26 Nos, (5.5 meter each),Vertical supports(60mmx60mmx2mm):- 46 Nos.(3meterseach), Centre Vertical supports (38mmx38mmx2mm)-26 Nos (2 meters each), Purlins (side wise) (38mmx38mmx2mm):-6Nos.(30 meters each),Purlin Roof Top (38mmx38mmx2mm):-8Nos. (30 meters each), Purlin front/Back(38mmx38mmx2mm):-4 Nos. (10 meter each.
Buffer Room- 3m x 2.5m x 3m x2m (L x W x CH: SH):-
Trusses (50mmx50mmx2mm):- 3 Nos. (6 meter each), Vertical supports (50mmx50mmx2mm):-8 Nos.(3 meters each), Purlins (side wise) (38mmx38mmx2mm):-6Nos.(2.5 meters each),Purlin (roof top) (38mmx38mmx2mm):-3Nos. (2.5 meters each), Purlin front & Back(38mmx38mmx2mm):-2 No. (3 meter each)
Gutter Height: 12 feet minimum, measured vertically from ground level to the gutter level
Central (Ridge) Height: 15 feet minimum, measured vertically from ground level to the highest point of the roof.The height of the trusses can be increased as per the site requirement. | 3,708.6 | Kg | 108 | ₹4,00,528.8 |
| 10 | Providing and fitting of Aluminium strips/profile (Side & top) 2” -Weight 0.35 Kg / mtr
Anodized Anti dust :[email protected]/mtr = 192.50 Kg | 192.5 | Kg | 109 | ₹20,982.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
BOQ_1110748.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .