Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.2 L+₹20,523 (0.71%)Rejected-Finance MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance Becomes L2 bidder | |
| 3 | L3₹29.6 L+₹54,942 (1.89%)Rejected-Finance H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L3 | Rejected-Finance Becomes L3 bidder | |
| 4 | L4₹35.9 L+₹6.9 L (23.7%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L4 | Rejected-Finance Becomes L4 bidder | |
| 5 | Rejected-Technical RANGIYA DIST KAMRUP ASSAM 781365 | BAKSA | ASSAM | 781365 | - | Rejected-Technical Not admitted due to WLR remark is NO |
Tender Value
Refer Docs
EMD Value
₹64,840
Closing Date
19 Oct 2023, 6:00 pmClosed
GE South Tezpur
GE South Tezpur, Mission Charlia
SPECIAL REPAIR FOR REPLACEMENT OF LT OH LINE TO UG CABLE SYSTEM AT MRS, OFFICE ENCLAVE, STN MI ROOM, MES OFFICE, AUDITORIUM AT MISA CAMP AREA UNDER GE (S) TEZPUR
2023_MES_619985_1
8805
Open Tender
Civil Works
Item Rate
210 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹64,840
Yes
20 Nov 2023
21 Sept 2023
21 Oct 2023
21 Sept 2023
19 Oct 2023
5 Oct 2023
22 Sept 2023 - 4 Oct 2023
Amount
Dismantling unserviceable ACSR conductor of any size and type from LT pole and removing the quantity from site.Complete all as specified and as directed.
Dismantling and taking down existing unserviceable / GI earth continuity conductor (of any size or type) from over head electric line and removing from site.Complete all as specified and as directed.
Dismantling insulators of any size /type and removing from site all as specified
Dismantling and taking down mild steel cross arms, bracings, supports, channels, angles, clamps etc from pole structure and removing from site complete all as specified and as directed.
Taking out unserviceable stay assembly including necessary excavation and demolition of PCC foundation and removing the same from site.Complete all as specified and as directed.
Taking down existing unserviceable stay wire of any size from LT pole all as specified
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and exc. 1.5m depth not exc 3.0m depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying and punning to 18 cm complete all as specified and as directed. (Note : Punned thickness shall be measured).
Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified.
M&L 100 mm bore steel for tubing light grade ISI marked for protection of cable including necessary joint including taking down old u/s one complete all as specified and as directed.
All as per Item No13 above but 50 mm dia.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 300 Sqmm x 3.5 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 185 Sqmm x 3.5 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm x 3.5 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm x 3.5 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm x 3.5 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm x 4 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 4 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 2 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm x 4 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
Supply, Laying, testing & commissioning of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm x 2 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge.
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 150 mm bore complete all as specified and directed.
Dismantling existing cement poles/ steel struts, any size carefully for reuse including necessary excavation demolition of concrete transportation cost etc. and removing the old unserviceable rubbish etc.Complete all as specified and as directed.
M & L for Steel tubular swaged poles complete with cast iron/MS base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31 , 9.0 meter long including making hole of 2 inch dia at 2.5 meter from bottom and 1 inch at 8 meter from bottom complete all as specified & directed. Note: PCC anti climbing device, cross arms insulator and earth work measure and paid separately)
M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ Panels etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed.
M & L PCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as coping of pole/panel including necessary form work as required complete as directed
Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension suitable to operate, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :- (a) Copper Busbar rating- 600 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-400 Amp, 4 pole, 35KA adjustable thermal and magnetic setting, 415 V, 50 Hz AC- 01 No(incoming) (d) MCCB-160 Amp, 4 pole, 25KA adjustable thermal and magnetic settig, 415 V, 50 Hz AC- 03 No(incoming) (d) MCCB-63 Amp, 4 pole, 10KA , 415 V, 50 Hz AC - 02 NoS (g) MCB-32 Amp, SPN, 10KA , 230 V, 50 Hz AC - 10 NoS (j) S&F digital ampere meter 3 1/2 display incl CT having CTR 400/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension suitable to operate, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :- (a) Copper Busbar rating- 300 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-160 Amp, 4 pole, 25K Aadjustable thermal and magnetic settig, 415 V, 50 Hz AC-01 No(incoming) (d) MCCB-63 Amp, 4 pole, 10KA fixed thermal and magnetic settig, 415 V, 50 Hz AC - 06 Nos (g) MCB-32 Amp, SPN, 10KA , 230 V, 50 Hz AC - 6 NoS (j) S&F digital ampere meter 3 1/2 display incl CT having CTR 160/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension suitable to operate, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :- (a) Copper Busbar rating- 300 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-160 Amp, 4 pole, 25K adjustable thermal and magnetic settig, 415 V, 50 Hz AC- 01 No(incoming) (d) MCCB-100 Amp, 4 pole, 16KA adjustable thermal and magnetic settig, 415 V, 50 Hz AC - 01 No (e) MCCB-63 Amp, 4 pole, 10KA thermal and magnetic settig, 415 V, 50 Hz AC - 02 No (g) MCB-32 Amp, SPN, 10KA , 230 V, 50 Hz AC - 5 NoS (j) S&F digital ampere meter 3 1/2 display incl CT having CTR 160/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
Supply, commissioning and testing cubical housing cabinet type, weather proof, outdoor type, factory made LT Panel boad, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension suitable to operate, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. Panel board shall comprise of :- (a) Copper Busbar rating- 200 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-100 Amp, 4 pole, 25KA adjustable thermal and magnetic setting, 415 V, 50 Hz AC-01 No(incoming) (d) MCCB-63 Amp, 4 pole, 10KA fixed thermal and magnetic setting, 415 V, 50 Hz AC - 03 No (g) MCB-32 Amp, SPN, 'C' curve, 10KA , 230 V, 50 Hz AC - 10 NoS (j) S&F digital ampere meter 3 1/2 display incl CT having CTR 100/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting (Inside cavity to be made in Pit for placing cover slab) made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed incl demolition to existing one complete.
Supply and fixing of loop in loop out junction box with SP 6-32 amp, IP 65 / IP 66 protection halogen free and weather proof of minimum size (130 x 180 x 77) mm, fixed to Pole with suitable clamp including nuts and bolts and washers incl provision of connector fixed to pole all as directed.
Supply and fixing PVC medium grade conduit 20 mm dia for drawing cable between pole junction box and light fitting brakect including fixing clamp made of GI strips and nut and bolts (Minimum 3 clamp in each pole to be provided.) complete all as specified and directed.
Supply and fixing 1100 volts grade PVC insulated weather proof sheathed copper cable 1.5 sqmm size 3 core between pole junction box and light fitting complete all as specified and directed. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
D G Corporation
SHANKAR ENTERPRISE
M/S Rajkamal Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .