Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-Finance | L1 | Accepted-Finance L1 bidder | |
| 2 | L2₹19.5 L+₹34,880 (1.82%)Accepted-Finance | L2 | Accepted-Finance L2 Bidder | |
| 3 | L3₹19.9 L+₹68,370.50 (3.56%)Accepted-Finance | L3 | Accepted-Finance L3 Bidder | |
| 4 | Not Admitted-Fee/PreQual/Technical 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical 18 19 MUNESWAR PURAM PARA ALAMNAGAR BIHIND ROSE CHILDREN ACADEMIC LUCKNOW UTTAR PRADESH 226017 | LUCKNOW | UTTAR PRADESH | 226017 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹19.5 L
EMD Value
₹20,000
Closing Date
15 Apr 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC I, Lucknow
Pareshan Bhawan, Vibhuti Khand, Lucknow
Work
2024_UPTCL_920467_1
Short term e-tender 119/2023-24
Open Tender
Electrical Works
Piece-work
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹20,000
30 May 2024
27 Mar 2024
16 Apr 2024
27 Mar 2024
15 Apr 2024
27 Mar 2024
Amount
Supply of 5 No. U-Bolted type Single Tension Fitting Assembly with Turn Buckle, suitable for Twin ACSR Moose Conductors and 33 K.V. Bus Bar Disc Insulator String, comprising of 4 No. 70 kN disc insulators, complete with hardware fittings, D-shackle, socket eye, ball hook, yoke plate, D-clip, tension clamp etc. as per technical specifications and sample.
Supply of 5 No. U-Bolted type Single Tension Fitting Assembly without Turn Buckle suitable for Twin ACSR Moose Conductors and 33 K.V. Bus Bar Disc Insulator string, comprising of 4 No. 70 kN disc insulators, complete with hardware fittings, D-shackle, socket eye, ball hook, yoke plate, D-clip, tension clamp etc. as per technical specifications and sample.
Supply of 2 No. U-Bolted type Single Suspension Fitting Assembly, suitable for Twin ACSR Moose Conductors and 33 K.V. Suspension Disc Insulator String, comprising of 3 No. 70 kN disc insulators, complete with hardware fittings, socket eye, ball hook, yoke plate, J-hook etc. as per technical specifications and sample.
Supply of 33 K.V. Section Isolator Bi-Metallic Terminal Connector suitable for Twin ACSR Moose Conductor duly made of LM-6 aluminum alloy with one side connecting the Twin ACSR Moose Conductor and other side connecting a plate of approx. size 100 x 100 x 20 mm complete with required plate and 4 Nos. 12 mm size dia. holes with Hot Dip G.I. Nut & Bolts and Spring / Plain Washers as per technical specifications and sample.
Supply of Spacer, suitable for 33 K.V. Bus Bar of Twin ACSR Moose Conductors with 250 mm spacing duly made of LM-6 aluminium alloy complete with 12 mm size dia. Hot Dip G.I. Nuts & Bolts and Plain / Spring Washers as per technical specifications and sample.
Supply of Spacer, suitable for Jumper of Twin ACSR Moose Conductors with 100 mm spacing duly made of LM-6 aluminum alloy complete with 12 mm size dia. Hot Dip G.I. Nuts & Bolts and Plain / Spring Washers as per technical specifications and sample.
Supply of Spacer, suitable for Jumper of Twin ACSR Panther Conductors with 75 mm spacing duly made of LM-6 aluminum alloy complete with 12 mm size dia. Hot Dip G.I. Nuts & Bolts and Plain / Spring Washers as per technical specifications and sample.
Supply of PG Clamp duly made of LM-6 aluminum alloy suitable for ACSR Moose to Moose Conductors with 4 Nos. 16 x 90 mm size dia. Hot Dip G.I. Nuts, Bolts, Spring & Plain Washers as per technical specifications and sample.
Supply of PG Clamp duly made of LM-6 aluminum alloy suitable for ACSR Moose to Panther Conductors with 4 Nos. 16 x 90 mm size dia. Hot Dip G.I. Nuts, Bolts, Spring & Plain Washers as per technical specifications and sample.
Supply of PG Clamp duly made of LM-6 aluminum alloy suitable for ACSR Panther to Panther Conductors with 4 Nos. 16 x 90 mm size dia. Hot Dip G.I. Nuts, Bolts, Spring & Plain Washers as per technical specifications and sample.
Supply of 33 K.V. Bus Isolator Bi-Metallic Terminal Connector suitable for Twin ACSR Panher Conductor duly made of LM-6 aluminum alloy complete with 4 Nos. 12 mm size dia. holes with Hot Dip G.I. Nut & Bolts and Spring / Plain Washers as per technical specifications and sample.
Supply of 33 K.V. Bus Isolator Bi-Metallic Terminal Connector suitable for Twin ACSR Moose Conductor duly made of LM-6 aluminum alloy complete with 4 Nos. 12 mm size dia. holes with Hot Dip G.I. Nut & Bolts and Spring / Plain Washers as per technical specifications and sample.
Supply of Hot Dip G.I. Nuts & Bolts of size 10 x 70 mm with Plain / Spring Washers as per technical specifications and sample.
Supply of Hot Dip G.I. Nuts & Bolts of size 10 x 50 mm with Plain / Spring Washers as per technical specifications and sample.
Opening of old and/or damaged Single or Twin Jumpers of ACSR Panther Conductor of all the 3 phases from existing 33 K.V. Main Bus Bar Conductors to Main Bus Isolators of 33 K.V. Feeders / Transfer Bus Coupler, 33 K.V. Capacitor Banks, 250 kVA Station Transformers, 33 K.V. PTs, 33 K.V. LAs by opening / cutting its Nuts & Bolts, P.G. Clamps and Terminal Connectors in four sections along with shifting of the dismantled conductors, clamps, connectors from switchyard to stores at the Sub Station.
Opening of old and/or damaged Single & Twin Jumpers of ACSR Moose Conductor of all the 3 phases from existing 33 K.V. Main Bus Bar Conductors and 63 MVA T/F 2nd Extension Bus Conductors to 33 K.V Main Bus Isolators of 63 MVA T/F 1st, 2nd & 3rd & Section Isolators after opening / cutting its Nuts & Bolts, P.G. Clamps and Terminal Connectors in four sections along with shifting of the dismantled conductors, clamps, connectors from switchyard to stores at the Sub Station.
De - stringing and Dismantling of existing 33 K.V. Main Bus Bar of Single ACSR Moose Conductor including de-hoisting of disc insulator tension string with associated tension fitting and disc insulator suspension string with associated suspension fitting from gantry along with shifting of the dismantled conductors, tension fittings, suspension fittings etc. from switchyard to stores at the Sub Station. (01 Job for each phase of each section of the Main Bus Bar)
De - stringing and Dismantling of existing 33 K.V. Extension Bus Bar of 40 MVA T/F 3rd of Single ACSR Moose Conductor including de-hoisting of disc insulator tension string with associated tension fitting and disc insulator suspension string with associated suspension fitting from gantry along with shifting of the dismantled conductors, tension fittings, suspension fittings etc. from switchyard to stores at the Sub Station. (01 Job for each phase of each section of the Main Bus Bar)
Dismantling of Lattice type Auxiliary Structure
Dismantling of 33 K.V. PT
Erection of 33 K.V. PT
Erection of Lattice type Auxiliary Structure
Earthing of Structures & Equipments by Cutting, Straightening, Laying 700 mm below inside ground & above ground with 50 mm x 6 mm size M.S. Flats to be provided by Department as per requirement including welding with main Earthmat and with the object to be earthed, excavation of Trenches, its back filling, Painting of Earthmat above ground level in two coats of Bus Green colour after application of red oxide primer including all other associated works to complete the Earthing work satisfactorily as per Technical Specifications.
Laying and Re - stringing of 33 K.V. Main Bus Bar of Twin ACSR Moose Conductor including hoisting of disc insulator tension string with associated tension fitting and disc insulator suspension string with associated suspension fitting from gantry along with shifting of the new conductors, tension fittings, suspension fittings etc. from stores at the Sub Station to the switchyard. (01 Job for each phase of each section of the Main Bus Bar)
Laying and Re - stringing of 33 K.V. Extension Bus Bar of 63 MVA T/F 2nd of Twin ACSR Moose Conductor including hoisting of disc insulator tension string with associated tension fitting and disc insulator suspension string with associated suspension fitting from gantry along with shifting of the new conductors, tension fittings, suspension fittings etc. from stores at the Sub Station to the switchyard. (01 Job for each phase of each section of the Main Bus Bar)
Jumpering with Twin ACSR Moose / Panther Conductors from newly laid 33 K.V. Main Bus Bar Conductors and 63 MVA T/F 2nd Extension Bus Conductors of Twin ACSR Moose Conductors to Main Bus Isolators of 33 K.V. Feeders / Transfer Bus Coupler, 33 K.V. Capacitor Banks, 250 kVA Station Transformers, 33 K.V. PTs, 33 K.V. LAs, 63 MVA T/F Ist, IInd & 40 MVA T/F and Section Isolators by due cutting & bending of conductors and tightening of jumpers with P.G. Clamps, connectors along with shifting of the conductors, PG Clamps, connectors from stores at the Sub Station to the switchyard.(01 Job for each jumper)
Fixing of 250/100 mm size Spacers (Bolted type) for ACSR Moose to Moose between above laid 33 K.V. Main Bus Bar Conductors of Twin ACSR Moose& Twin moose jumpers of T/F. (01 Job for each spacer)
Safe carriage of following equipments as needed from 220 KV S/S Gomti Nagar / other transmission sub station in lucknow (approx max distance 15 KM) to 132 KV S/S Gomti Nagar Lucknow including loading carriage and at receving site
(a) 33 KV Bus / Line Isolator with insulator
(b) ACSR Panther / Moose Conductor
(c) MS Flat 50x6 mm
Meena Elect & Engg. Works
Gupta Elect and Engg Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .