Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 CrAccepted-AOC SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹25.6 Cr | L1 | Accepted-AOC lowest |
| 2 | L2₹25.6 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹25.6 Cr | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹25.9 CrRejected-Finance D NO 58 21 50 BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹25.9 Cr | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹26.5 CrRejected-Finance | ₹26.5 Cr | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹27.9 CrRejected-Finance | ₹27.9 Cr | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹27 Cr
EMD Value
₹15 L
Closing Date
29 Apr 2025, 6:00 pmClosed
CHIEF ENGINEER NAVY VISAKHAPATNAM
CHIEF ENGINEER NAVY STATION ROAD VISAKHAPATNAM
PROVISION OF DEFICIENT SHOPPING CENTRE AND ASSOCIATED FACILITIES IN HIGH RISE CONFIGURATION AT NAVAL BASE VISAKHAPATNAM
2025_MES_692742_2
85445
Open Tender
Civil Works
600 days
VISAKHAPATNAM
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Garrison Engineer NB Visakhapatnam
₹15 L
Yes
2 Jun 2025
8 Apr 2025
6 May 2025
8 Apr 2025
29 Apr 2025
22 Apr 2025
Amount
Schedule "A" Part – I to Schedule "A" Part – XII: NOTE: Schedule "A" Part – I to Part – XII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I .
Lumpsum price worked out by the contractor for "Earthwork/ Excavation", as listed in Schedule "A" Part – II .
Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – III .
Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – IV .
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – V .
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "Lifts", as listed in Schedule "A" Part – VIII .
Lumpsum price worked out by the contractor for "Air conditioning", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "Fire fighting and fire alarm system", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "Lightning Protection", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for Pile foundation", as listed in Schedule "A" Part – XII
Schedule "A" Part - XIII [Miscellaneous Items]
Internal Electrification
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and mounting on modular brackets, including modular brackets and plates as required at site for fixing modular type switches, fittings, regulators etc., concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 13 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 13 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board complete all as specified.
All as per item No.13 here-in-before but controlled by two two way switch complete all as specefied and directed.
All as per Serial Item No. 13 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 13 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.
Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
S&F energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S & F Energy efficient LED light fitting with tube 19/20 watt, 230 Volts, 50 Hz surface mounted decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed Make: BAJAJ / PHILIPS / CG / HAVELLS / WIPRO / SURYA
S & F Energy efficient LED light fitting 36 watt, recess mounted square light fitting with all accessories with mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed Make: BAJAJ / PHILIPS / CG / HAVELLS / WIPRO / SURYA
LED Security light fitting with tube 25 W new generation energy saving & environmental friendly long life versatile pressure die cast aluminium Luminaire with high efficient LEDs as lighting source and PC cover having top opening separate driver compartment with IP 66 protection pre wired with 1.0 Sq.mm copper conductor cable up to connector including 1.5m long GI tubing medium grade 32mm dia bend to required shape fixing on wall with suitable MS brackets complete all as specified and directed. Make: BAJAJ / PHILIPS / CG / HAVELLS / WIPRO / SURYA
Energy saving ceiling mounted decorative LED Luminaire, 8 Watt, 230 Volts, Surface mounted with Opal diffuser for soft light including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and directed. Make: CG Cat No.LCDS-08-CDL or equivqlent in BAJAJ / PHILIPS / HAVELLS / WIPRO / SURYA
Energy efficient Sleek LED Mirror Light fitting with high output diffuser, 10 Watt, 230 Volts, 600mm long, surface mounted including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and directed. Make: BAJAJ / PHILIPS / CG / HAVELLS / WIPRO / SURYA
LED Security light fitting with tube 20 W new generation energy saving & environmental friendly long life versatile pressure die cast aluminium Luminaire with mid power LEDs as source and HF electronic driver pre wired with 1.5 Sq.mm copper conductor cable up to connector including 2m long GI tubing medium grade 32mm dia bend to required shape fixing on wall with suitable MS brackets complete all as specified and directed. Make: BAJAJ / PHILIPS / CG / HAVELLS / WIPRO / SURYA
Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 3 runs of 2.5 Sq.mm & one run of 25mm dia PVC Conduit will be measured as one unit]
Sub main wiring with 2 runs of single core 4.0 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 3 runs of 4.0 Sq.mm & one run of 25mm dia PVC Conduit will be measured as one unit]
Sub main wiring with 2 runs of single core 6.0 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 3 runs of 6.0 Sq.mm & one run of 25mm dia PVC Conduit will be measured as one unit]
Sub main wiring with 4 runs of single core 10.0 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 10.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. [Note: 5 runs of 10.0 Sq.mm & one run of 25mm dia PVC Conduit will be measured as one unit]
S & F MCCB DB, vertical double door, TPN, 6 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision for fixing MCCB FP 40 Amps, 10 KA as incommer and outgoing circuits MCB SP/TP, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
S & F MCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision for fixing MCB TPN, 10 KA as incommer and outgoing circuits MCB SP/ TP, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
S & F MCB DB, double door, single pole and neutral 12 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
S & F MCB DB, double door, single pole and neutral 8 way, sheet steel, phospetised powder painted with 200 amps rated bus bar, 240 Volts, neutral link, IP : 43 protection, flush mounting type, concealed in walls complete all as specified and as directed.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Internal water supply
S & F 15 mm dia fancy type, chromium plated, two way bib tap/ one way, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or to for brass ferrule complete all as specified and as directed. Note: CAT No. OPP-15041PM of Jaqaur or its equivalent as approved by GE
Sewage disposal
M&L Precast SFRC manhole cover slabs opening size 600x600x70 mm thick , MD-10 Grade, conforming to IS 12592-2002 complete all as specified and as directed.
External water supply
Cutting existing GI/DI pipe line of 150 mm dia for alterations or additions necessarily done in position without taking down, dewatering for inserting flanged sockets, 'Tee' with reducer to 150 x 150 x 150 mm etc., for tapping, including necessary earthwork, exacavation and required specials complete all as specified and directed.
M& L for ductile iron pipe 150 mm dia, with spigot and socket end centrifugally (spun) cast class K-9 conforming to IS -8329 including special such as tees, elbow, bends reducers tapper pieces including testing and commissioning complete all as specified and directed.
M & L for masonry valve chamber of size 900 X 900 X 600 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified and as directed.
Supply, install, testing and commissioning of submersible pump set , head 40 Mtrs, discharge 375 LPM, 7.5 HP, 3 Phase and PCC foundation and connecting up with suitable size of copper conductor cable from Panel to Pump complete all as specified and as directed. complete all as specified and directed.
Supply, install, testing and commissioning of Submerssible pump Star Delta Starter suitable for upto 7.5 HP motor complete all as specified and as directed
External Electrification
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Supply, install, testing and commissioning of LT Cubical Panel board CPRI approved made out of CRCA sheet 3.15 mm thick indoor Compartmenatal Type totally enclosed, Dust and vermin proof with front opening, hinged doors with projected raised platform of suitable size with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc made of rust proof material including all as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 600 A capacity complete with powder coating, necessary internal electric connection with and including the following
Incoming:[a] MCCB, AC 3 Phase 415 V, 50Hz 4 pole,400 A, breaking capactiy 35kA- 01 No. Outgoing:[a] MCCB AC 3 Phase,415 V, 50Hz, 4 pole, 320 A breaking capacity 36 kA with adjustable type thermal and magnetic setting relays - 1 No. [b] MCCB AC 3 Phase,415 V, 50Hz 4 pole, 250 A breaking capacity 25 kA with adjustable type thermal and magnetic setting relays - 1 Nos. [c] Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs [d] LED indicating lamps with colour Red, Yellow, Blue - 03 Sets
Supply, install, testing and commissioning of LT Cubical Panel board CPRI approved made out of CRCA sheet 3.15 mm thick indoor Compartmenatal Type totally enclosed , Dust and vermin proof with front opening, hinged doors with projected raised platform of suitable size with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc made of rust proof material including all as per IS: 8623 , aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection with and including the following
Incoming: [a] MCCB AC 3 Phase 415 V, 50Hz 4 pole, 160 A, breaking capactiy 16 kA with fixed type thermal and magnetic setting relays -01 No, [b] ON Load Change over switch, four Pole, 160 Amps complete - 01 No Outgoing:[a] MCCB AC 3 Phase,415 V, 50Hz, 4 pole, 63 A breaking capacity 25 kA with adjustable type thermal and magnetic setting relays - 06 Nos.(For lift (3 Nos),jockey pump , Booster pump and spare) [b] MCCB AC 3 Phase,415 V, 50Hz ,3 pole, 32 A breaking capacity 16 kA -1No ( for fresh water pump) [c] MCB AC 3 Phase,415 V, 50Hz SPN, C curve, 32 A breaking capacity 10 kA - 02 Nos. (for High Mast lights) (d )Timer switch 250 V, single phase of max 20 Amps rated, with contactor-1 No [e) Intelligent Panel meter to measure voltage, current, frequency, etc with all connected CTs [f] LED indicating lamps with colour Red, Yellow, Blue - 03 Sets
Supply, install, testing and commissioning of LT Cubical Panel board CPRI approved made out of CRCA sheet 3.15 mm thick indoor Compartmenatal Type totally enclosed , Dust and vermin proof with front opening, hinged doors with projected raised platform of suitable size with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc made of rust proof material including all as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 500 A capacity complete with powder coating, necessary internal electric connection as required with and including the following
Incoming:[a] MCCB AC 3 Phase 415 V, 50Hz 4 pole, 320 A, breaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 01 No. Outgoing: [a] MCCB AC 3 Phase,415 V, 50Hz , 4 pole, 63 A breaking capacity 25 kA with adjustable type thermal and magnetic setting relays - 7 Nos.( Building DBs ) [b] MCCB AC 3 Phase,415 V, 50Hz ,4 pole, 160 A breaking capacity 25 kA with adjustable type thermal and magnetic setting relays - 1 Nos.( For fire panel) [c] MCCB AC 3 Phase,415 V, 50Hz, 4 pole, 160 A breaking capacity 25 kA with adjustable type thermal and magnetic setting relays - 1 Nos.( For AMF panel) [d] Intelligent Panel meter to measure voltage, current, frequency etc with all connected CTs [e] LED indicating lamps with colour Red, Yellow, Blue - 03 Sets
Supply, install, testing and commissioning of LT Cubical Panel board CPRI approved made out of CRCA sheet 3.15 mm thick indoor Compartmenatal Type totally enclosed , Dust and vermin proof with front opening, hinged doors with projected raised platform of suitable size with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc made of rust proof material including all as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300A capacity complete with powder coating, necessary internal electric connection with and including the following
Incoming:[a] MCCB AC 3 Phase 415 V, 50Hz 4 pole, 160 A, breaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 01 No. Outgoing:[a] MCCB AC 3 Phase,415 V, 50Hz, 3 pole, 125 A breaking capacity 25 kA with adjustable type thermal and magnetic setting relays - 2Nos. [b] MCCB AC 3 Phase,415 V, 50Hz, 3 pole, 63 A breaking capacity 25 kA with adjustable type thermal and magnetic setting relays - 2 Nos. [d] Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs [e] LED indicating lamps with colour Red, Yellow, Blue - 03 Sets
Rubber Mat at LT Panel of size 1 m x 2 m x 10 mm thick all as per IS 15652 (2006) complete all as specified and directed.
LIFTS
Notefor Serial item No. 50 & 51 : Silver mirror polish stainless steel on both sides .the wall inside the car should be sapphire mirror polish stainless steel. the front wall of the car should be silver mirror polish stainless steel.the floor of the car should be jet black granite.the COP in side the car should be full height silver mirror polish stainless steel faceplate with round flush mounted,wall buttons.car indicator should be colour LCD display,silver mirror polish stainless steel on lintel,flush mounted finish of 16 gauge with infra-red sensors all along the height for car door with automatic rescue/leveling device (ARD) (with + or -5 mm) with suitable batteries,Floor position digital indicators in car and all landing with call indicating lights etc including necessary joists and beams for mounting machine in the machine room including additional/alteration to existing lift well if any, all necessary civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :
a) Fire man switch. (b) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity or batteries designed for running the lift with full load. © Battery operated emergency light (LED Ceiling fitting) alarm ( speaker for emergency alarm system to be fixed) and stop button in car with rechargeable areangement for battery). (d) Suitable decorative lighting arrangement inside the lift (e) One sleek circular PVC heavy duty fan in false ceiling. (f) Aluminium chequred plate (3 mm thick) as flooring joint in chequred plate should not more than one and top covering with PVC flooring complete. (g) Non stop button/independent operation. (h) Over load warning indicator both audio and visual type with tripping system having relay etc. (j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds.
(k) Car size shall be conform to IS -3531-1976 and body to be stainless steel of 16 gauges moon rock finish with stainless steel hand rail 38 mm hairline finish. (l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (m) Mirror of 4 mm thickenss of suitable size as specified. (n) Opening with glass door of 5 mm thick 200 x 600 mm size in all the doors. (o) Specification plate with complete details. (p) Continuous earthing for machine and equipments. (q) Steel wire rope of adequate size as per relevent IS and as per manufacturer specifications. (r) Other standard fixtures and fittings like guide rail, sheaves counter weights with guards, buffer gear unit brakes, control panel, lock, governor, car operational panel, control and trailing cables complete. (s) Full length display indicator panel. (u) Suitable phase reversal relay shall be provided on the controller to protect lift /equipment against phase reverse, phase failure and low voltage.
(v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800 mm with toughended glass not less than 08 mm thick. (w) Lift shall be equipped with suitable Inter-communication equipment for communicating at ground floor. Note: a) Cost of lift inspector inspection is deemed to be inclded in the item rate. provision of one lamp holder, one socket with PVC box of sitable size to be provided at the top of lift for servicing. b) Lift of 13 passengers only has to be provide with all necessary facilities require for fire lift as per NBC -2016.
Supply, install testing & commisioning of electrically operated Goods lift of carrying capacity 1000 Kgs, 1 metre/sec speed with single speed motor , 3 phase, 50 Hz, 415 Volts, AC, confiriming to IS 14665 and amended suitable to serve upto 8 floors (G+7) floors with AC variable voltage frequency drive (AC VVVF) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors,automatic rescue drive (ARD) system, 3D infrared sensor in full height of doors & built in announcing system without handset (03 Nos, one each in car, one in Machine room & one near Ground floor landing door) complete all as specified and directed. Note : Cost of comprehensive/periodical maintenance of Lifts including spare parts during defect liability period is deemed to be included in the rate quoted for the lift item under respective phase.
AIR CONDITIONING
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and as directed.
Supply and fix copper tubing with insulation of 1/4" dia suitable for suction and discharge line of split AC complete all as specified and as directed.
Supply and fix copper tubing with insulation of 1/2" dia suitable for suction and discharge line of split AC complete all as specified and as directed.
S & F CPVC (chlorinated poly vinyl chloride) pipes schedule 80 pipes plain CPVC schedule 80 fitting 25 mm inner dia of pipe, fixed on walls, ceilings or in floors etc. complete all as specified and directed. Note: Pipes to fixed on external walls of multi-stroyed building upto a height of 20 metre
Fire fighting and fire alarm system
S & F Cable PVC insulated LT 1100 V grade with copper conductor of size 2 core 1.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc including 20 mm dia PVC with suitable calamps spacers bolts nuts etc complete all as specified and as directed
Supply, install, testing and commissioning of integrated public address and talk back [two way communication] panel having 06 zone, voice alarm controller with USB, MP3 player including telephone cable complete all as specified and as directed
Supply and fix micro processor based addressable type Fire alarm repeater panel suitable for fire alarm system with heavy duty charger and LED display, mother board cable and spare parts complete all as specified and as directed.
Supply, Install, testing & commisioning of totally enclosed feeder piller indoor type fabricated out of 2.0 mm thick CRCA sheet dust and vermin proof powder coated double door type(independent cabin including locking arrangement for each MCCBs , bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V, 600 A capacity complete with powder coating, necessary internal electric connection as required and including of the following:
a) MCCB AC 3 Phase 415 V, 50 Hz ,4 pole, 250 A, 25 kA with adjustable type thermal and magnetic setting relays - 01 No. b) MCCB AC 3 Phase 415 V, 50Hz 4 pole ,125 A, 16 kA with adjustable type thermal and magnetic setting relays - 02 Nos c) MCCB AC 3 Phase 415 V, 50Hz 4 pole ,40 A, 16 kA with adjustable type thermal and magnetic setting relays - 03 Nos d) MCB SPN 20 Amps - 02 Nos e) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases-1 set f) Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers - 1 No g) Star Delta starter for pump of capacity 50 HP with protective relay SPP/OLR-2No in separate enclosure h) Star delta starter for pump of capacity 7.5 HP-2No j) Star delta starter for pump of capacity 7.5 HP-1 No in separate enclosure Control panel for diesel driven pump of suitable capacity.
Supply and fix flanged end lift type Foot valve 100 dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.
Supply and fix flanged end lift type Foot valve 150 dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.
S&F 6kg fire extinguisher dry chemical powder (ABC) Type complete all as specified and directed.
S&F 4.5kg fire extinguisher Co2 type complete all as specified and directed.
S&F 9kg/litre fire extinguisher water stored pressure type complete all as specified and directed.
S&F fire buckets 3 Nos with stand complete all as specified and directed.
S&F Mechanical foam fire extinguisher 9 litre capacity complete all as specified and directed.
Material and labour for pipe supports of all type of pipes including hangers/ fasteners/ elbows/ supports/ tee/ angles for fixing of MS pipe in wall /roof floor etc., including necessary fixing arrangements all as specified and directed.
M & L for masonry valve chamber of size 1000 X 1000 X 1000 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified and as directed.
S & F Automatic air release valve 50 mm dia complete all as specified and directed.
LIGHTENING PROTECTION
S & F Integral LED Aviation obstruction Light, PF>0.90, comprising of aluminium housing with polycarbonate enclosure, 10 watts single headed including standard fixing arrangements and connecting up complete all as specified and as directed. Make: BGAV 302 LED of BAJAJ or its equivalent as approved by GE.
S & lay Cable PVC insulated armoured PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc., with suitable size clamps, spacers, bolts, nuts etc., all as specified and as directed
Supply and fix timer switch 250 Volt Single phase 20 Amps with contactor fitted FRP made box with IP-65 protection complete all as specified and directed.
DG Set
Supply, Install, Testing and commissioning of Silent Diesel Engine driven Generating Set of Capacity 82.5 KVA / 66 KW, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364, conforming to CPCB-IV+ approved norms [latest IS code] complete with relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS and foundation etc. including following: [Make: Kirloskar Green / cummins / Ashok Leyland / Greaves Cotton]
A. ENGINE: Direct Injection, Water Cooled Engine, 4 Cylinder, in-line, 4 Stroke, rated at 1500 RPM, conforming to BS – 5514 and having following specifications: [i] In- line fuel pump with Electronic Governor for 82.5 KVA. [iii] Stainless Steel Exhaust Flexible Coupling and Exhaust Pipe duly insulated with Glass Fire Wool and Plain GI Sheet Cladding & extended outside the building. [iv] Silencer [v] Radiator [vi] Coolant Inhibitor [vii] Plate type Lub Oil Cooler [viii] Spin-On-Filters-Coolant, Fuel, Fuel & Lub Oil [ix] Dry type, Heavy Duty, Replaceable Paper Element Air Cleaner with Restriction Indicator [x] Flywheel Housing and Flywheel to suit Single Bearing Alternator [xi] Electrical Starter Motor [xii] Battery Charging Alternator [xiii] 1 X 12 Volts Batteries, 120 AH Capacity, 25 Plate with Connecting Leads and Terminals of 35 Sq.mm size Multistranded Copper Conductor Cable [xiv] First fill of Lub Oil.
B. ALTERNATOR: [i] Self Excited & Self Regulated [ii] Voltage Regulation ± 1 % [iii] Class H Insulation [iv] Salient Pole Revolving Field [v] Digital Automatic Voltage Regulator [vi] Standard Enclosure IP-23 [vii] Interference Factor: 50 [viii] Total Harmonic Factor: Better than 2% [ix] Supplying power to variable electrical load for unlimited hours. Prime Power [PRP] is in accordance with ISO 8528. 10% over load capacity for one hour every 12 Hours of operation and will be suitable for tropical condition.
C. ENGINE CONTROL WITH AMF PANEL: Standard Control Panel along with DG Set, Cubicle with CRCA Sheet of 2 mm thick and angle iron structure including following accessories: [i] MCCB, FP, 200 Amps – 1 Nos. [ii] Contactor, 4 Pole, 200 Amps capacity – 2 Nos [iii] Contactor, 4 Pole, 200 Amps capacity – 1 Nos for Neutral [iv] Microprocessor based LED type Multifunctional Intelligent Panel Meter for showing Current, Voltage, Frequency, Power Factor, Energy Consumed, Speed, Temperature of Engine, Oil Level, Battery Voltage etc. [v] Digital Frequency Meter – 1 No [vi] Digital Power Factor Meter with CTs – 1 No [vii] Three Phase, CT Operated Digital KWH Meter 200 Amps – 1 No [viii] Indicating Lamps for "DG ON & LOAD ON" [ix] Instrument displaying Water Temperature, Lube Oil Pressure, Engine RPM, Battery Charging. [x] PVC Sleeve insulated Tinned Aluminium bus Bar suitable for 300 Amps current carrying capacity [TPN] [xi] Instrumentation, Control Switch Fuses / MCBs duly wired and ferruled. [xii] Coolant Heater with Thermostatic Switch [xiii] Lub Oil Heater
D. FUEL TANK: In-Built Fuel Tank of suitable capacity for minimum 12 Hours run but not less than 230 Litres capacity with all fittings and accessories. E. ACOUSTIC ENCLOSURE: [i] Designed to meet stringent MOEF / CPCB norms 75 dBA @ 1 m at 75% load under free field conditions. [ii] Air Inlet Louvers shall be designed to operate at rated load even at 50°C Air Inlet Temperature. [iii] Cubicle shall be powder coated for long lasting service life and super finish with UV Resistant Powder Coating and shall withstand extreme environment. Stain Steel hardware shall be used. [iv] Insulation Material shall meet / conform to IS – 8183 Specifications for better sound attenuation [v] Provision of Genset Controller for Engine & Alternator. F. ACCESSORIES: [i] Periodical Maintenance Tools as per Manufacture [ii] Operational, Spare Parts, & Installation Guidelines and Catalogue.
Note: Rate quoted is also deemed to be including the following: [i] Provision of 200mm thick PCC 1:1½:3, Type A1, using 20mm graded stone aggregate Foundation over 200mm thick PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 200mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick complete as per manufacturer's instructions with Anti-Vibration Mounting Pads as per manufacturer’s guidelines including necessary earthwork excavation, return filling, removal surplus soil and applying two coats of Cement Based paint over a coat of Alkali Resistant Primer complete etc. complete all as directed. [ii] Testing of DG Set shall be carried out by the IEM. [iii] Artificial load i.e. strip heaters of suitable capacity to be made available during test. [iv] Extended terminals with tinned copper has to be provided for terminating the incoming & out going cable with suitable lugs for ACB’s / MCCB's if required.
[v] U/G cable shall be laid / connected to DG Set Cubicle Panel to AMF Control Panel [Changeover Panel] all as specified. [vi] Provision of cable gland & Aluminium lugs of suitable size for terminating the cable at both ends. [vii] DG Set shall be covered with Galvalume Sheet Roofing / Canopy of minimum size of 2.80m X 1.20m X 1.60m with pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size and using Mild Steel Tubular Trusses, Posts, Frame work etc. including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS - 1161, Grade YST - 240, Medium Grade of approved sections complete all as directed and the rate quoted shall be deemed to be included for the same. [viii] Exhaust Pipe shall be insulated with 25mm thick Resin Bonded Fibre Glass Wool of density 32 kg/Cu.m and wrapped with 24 SWG Aluminium sheet duly painted with approved colour & quality complete as per ISO 8528 and 3046 / BS 5514 Specification and IS – 4722 and IS – 1460 complete all as specified.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
STRUCTURAL GLAZING
Design, supply, fabrication and fixing in position of structural Glazing system to external faces of the building at all floors [G+6] and locations of powder coated (50 micron thick) of approved colour Aluminium sections of approved size and make as Mullion & Transoms, the façade be fixed to the structure with powder coated MS brackets & anchor fasteners, the mullions are to be connected to brackets by stainless steel SS-316 nut & bolts, sufficient provision to be made to allow free movement of components due to temperature, deflection of RCC structure etc., without inducing stresses in structure, including provision and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass and provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc., including providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight complete all as specified and directed.
Supply only factory assembled insulating glass units (IGUs) for doubled glazed vision glass panels comprising of hermetically-sealed insulating glass unit (6-12- 6 mm) comprising of heat strengthened coloured tinted toughened glass 6mm thick of approved colour and shade with reflective soft coating on outer surface and an Heat strengthened clear float glass 6 mm thick on inner surface having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K ,separated by a 12 mm thick spacer material, the insulating air space shall be filled with air or a noble gas, such as argon inside including primary seal and secondary seal (structural silicone sealant) etc., complete all as specified and directed
PILE FOUNDATION
Boring for bored cast in situ piles 600 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 600mm dia in hard rock / fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Carrying out Initial load [Compression] test on 600mm dia piles, complete all as specified and directed.
Carrying out Initial load [Lateral] test on 600mm dia piles, complete all as specified and directed.
Carrying out routine load test [Compression] on 600mm dia piles, complete all as specified and directed.
Carrying out routine load test [Lateral] on 600mm dia piles, complete all as specified and directed.
Carrying out low strain integrity test on 600mm dia piles including analysing the results complete all as specified and directed.
Carrying out initial pullout test on 600mm dia piles, complete all as specified and directed.
PHASE -II OUTSOURCING OF 13 PASSENGERS AND GOODS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 50 AND 51 DURING FIRST YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 13 passanger & good lifts for main Buildings in each shift on all the days including Sunday & holidays in one shift a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during Defect liability period complete all as specified and as directed.
PHASE -III OUTSOURCING OF 13 PASSENGERS AND GOODS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 50 AND 51 DURING SECOND YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 13 passanger & good lifts for main Buildings in each shift on all the days including Sunday & holidays in one shift a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
PHASE -IV OUTSOURCING OF 13 PASSENGERS & GOODs LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 50 AND 51 DURING FIRST YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 13 passanger & good lifts for main Buildings in each shift on all the days including Sunday & holidays in one shift a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts -02 Nos and Good lifts - 01 No to serve any number of floors all as mentioned vide SI No. 50 & 51 of BOQ Phase-I during 1st year after expiry of defects liability period all as specified and directed
PHASE -V OUTSOURCING OF 13 PASSENGERS & GOODs LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 50 AND 51 DURING SECOND YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 13 passanger & good lifts for main Buildings in each shift on all the days including Sunday & holidays in one shift a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts -02 Nos and Good lifts - 01 No to serve any number of floors all as mentioned vide SI No. 50 & 51 of BOQ Phase-I during 2nd year after expiry of defects liability period all as specified and directed
PHASE -VI OUTSOURCING OF 13 PASSENGERS & GOODs LIFTS AND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 50 AND 51 DURING THIRD YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 13 passanger & good lifts for main Buildings in each shift on all the days including Sunday & holidays in one shift a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 3rd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts -02 Nos and Good lifts - 01 No to serve any number of floors all as mentioned vide SI No. 50 & 51 of BOQ Phase-I during 3rd year after expiry of defects liability period all as specified and directed
RAGHUSONS INFRA ENGINEERING PVT. LTD (BID ID -3289119)
PJR PROJECT CONSTRUCTIONS PRIVATE LIMITED (BID ID -3288154)
jd constructions (BID ID -3289475)
LUMOS INFRA PVT LTD (BID ID -3289365)
SOOD ASSOCIATES PVT LTD (BID ID -3289446)
SHRI GURMUKHDAS CONTRACTORS PVT. LTD. (BID ID -3289423)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid