| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC SRIKONA POTAPOLA CHHAKA CHANDIPUR ROAD BALASORE ODISHA 756025 | BALASORE | BALESHWAR | ODISHA | 756025 | ₹2.8 Cr Quoted ₹2.9 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹2.9 Cr+₹4.7 L (1.65%)Rejected-Finance MAZUMDER LANE VILL P O BERENGA PT II P S SILCHAR DIST CACHAR ASSAM 788005 | SILCHAR | CACHAR | ASSAM | 788005 | ₹2.9 Cr+₹4.7 L (1.65%) | L2 | Rejected-Finance HIGH BID VALUE |
| 3 | L3₹3.3 Cr+₹42.7 L (14.9%)Rejected-Finance GATANGA MISSION CHARALI TEZPUR 784154 ASSAM | SONITPUR | ASSAM | 784154 | ₹3.3 Cr+₹42.7 L (14.9%) | L3 | Rejected-Finance HIGH BID VALUE |
| 4 | L4₹3.4 Cr+₹53.3 L (18.6%)Rejected-Finance | ₹3.4 Cr+₹53.3 L (18.6%) | L4 | Rejected-Finance HIGH BID VALUE |
| Sl No | Description | Qty | Unit | M/S MOHANPASARI L3 | bholanath bera L1 | BAYAJ UDDIN MAZUMDER L2 | M/S SALO ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00BUILDING & STRUCTURE (Sch 'A' PART-I) | |||||||
| 1.01 | Lump sum price worked out by the Contractor for “BUILDING & STRUCTURE” as listed in Schedule ‘A’ Part-I.
Representing ** ___ % ______ percent *Above / Below the lump sum price of 2,03,83,424.93 inserted by the MES in Schedule ‘A’ Part-I. | 1 | LUMP SUM | 2,54,46,832.6 ₹2,54,46,832.6 | 2,13,83,424 ₹2,13,83,424 Lowest | 2,21,16,016.05 ₹2,21,16,016.05 | 2,44,98,745 ₹2,44,98,745 |
| 2.00SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II) | |||||||
| 2.01 | Lump sum price worked out by the Contractor for “SITE CLEARANCE AND STIE DEVELOPMENT” as listed in Schedule ‘A’ Part-II.
Representing ** ___ % ______ percent *Above / Below the lump sum price of 5,98,263.62 inserted by the MES in Schedule ‘A’ Part-II. | 1 | LUMP SUM | 4,00,000 ₹4,00,000 Lowest | 4,78,610.9 ₹4,78,610.9 | 5,05,000 ₹5,05,000 | 6,98,456 ₹6,98,456 |
| 3.00INTERNAL WATER SUPPLY (Sch 'A' PART-III) | |||||||
| 3.01 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III.
Representing ** ___ % ______ percent *Above / Below the lump sum price of 2,96,520.18 inserted by the MES in Schedule ‘A’ Part-III. | 1 | LUMP SUM | 3,50,000 ₹3,50,000 | 2,96,520.18 ₹2,96,520.18 | 2,50,000 ₹2,50,000 Lowest | 3,56,214 ₹3,56,214 |
| 4.00INTERNAL ELECTRIFICATION (Sch 'A' PART-IV) | |||||||
| 4.01 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-IV.
Representing ** ___ % ______ percent *Above / Below the lump sum price of 13,09,371.59 inserted by the MES in Schedule ‘A’ Part-IV. | 1 | LUMP SUM | 11,25,000 ₹11,25,000 Lowest | 11,52,247 ₹11,52,247 | 13,95,550 ₹13,95,550 | 15,04,569 ₹15,04,569 |
| 5.00ROAD, PATH, CULVERT (Sch 'A' PART-V) | |||||||
| 5.01 | Lump sum price worked out by the Contractor for “ROAD, PATH, CULVERT” as listed in Schedule ‘A’ Part-V.
Representing ** ___ % ______ percent *Above / Below the lump sum price of 15,39,758.71 inserted by the MES in Schedule ‘A’ Part-V. | 1 | LUMP SUM | 15,00,000 ₹15,00,000 Lowest | 15,39,758 ₹15,39,758 | 15,05,786 ₹15,05,786 | 17,05,693 ₹17,05,693 |
Tender Value
₹3 Cr
EMD Value
₹3.8 L
Closing Date
23 Dec 2025, 6:00 pmClosed
SHRI SAURABH, IDSE, CWE
HQ CWE Tenga PIN-900194
PROVN OF DEFICIENT MD ACCN AT AF STATION MISSAMARI UNDER GE MISSAMARI
2025_MES_741358_1
8588/E8
Open Tender
Civil Works
Lump-sum
540 days
GE Missamari
A a (i)
8 documents required · 8 mandatory
₹2,000
Yes
GE MISSAMARI
₹3.8 L
Yes
25 Mar 2026
25 Nov 2025
30 Dec 2025
25 Nov 2025
23 Dec 2025
16 Dec 2025
Amount
BUILDING & STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDING & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of 2,03,83,424.93 inserted by the MES in Schedule ‘A’ Part-I.
SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND STIE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of 5,98,263.62 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of 2,96,520.18 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of 13,09,371.59 inserted by the MES in Schedule ‘A’ Part-IV.
ROAD, PATH, CULVERT (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “ROAD, PATH, CULVERT” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of 15,39,758.71 inserted by the MES in Schedule ‘A’ Part-V.
SEWAGE DISPOSAL (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of 13,85,775.44 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' PART-VII)
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of 5,92,962.38 inserted by the MES in Schedule ‘A’ Part-VII.
EXTERNAL WATER SUPPLY (Sch 'A' PART-VIII)
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of 64,457.20 inserted by the MES in Schedule ‘A’ Part-VIII.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of 2,85,159.63 inserted by the MES in Schedule ‘A’ Part-IX.
SOLAR WATER HEATER/HOT WATER SUPPLY (Sch 'A' PART-X)
Lump sum price worked out by the Contractor for “SOLAR WATER HEATER/HOT WATER SUPPLY” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of 93,865.86 inserted by the MES in Schedule ‘A’ Part-X.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' PART-XI)
SITE CLEARANCE AND SITE DEVELOPMENT Bringing approved earth (as approved GE from source outside defence land including all taxes, royalty etc as required including transportation complete all as specified and directed” Note:- (a) Earth required for the item, shall be supplied by contractor, from outside MOD land, of any lead, at his own arrangement. (b) All cost of procurement of earth including cost of transportation, compaction royalties, tax etc shall be deemed to be included in the unit rate quoted by the contractor. (c) Forming embankment/ filling in low laying area including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick, watering ramming/ rolling and finishing of required size, safe etc. not exceeding 1.5 mtr high from base/natural ground level. (d) With reference to clause 3.6 of MES Schedule Part-III of Serial Page No. 22 it is clarified that measurement of the above item shall be finished embankment/ traverse of filled earth after consolidation/ compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk (e) Total qty/ partial qty of earth may not be available in Missamari area. The contractor shall bring the earth outside area and it is advised to quote the rate considering availability of soil and its lead involved.”
INTERNAL ELECTRIFICATION S & F LED ADORE 5 W B22 CDL with B 22 base capacity 1200 lumen CRI should be 80 with power factor greater than 0.90 & IP Rating IP20 complete all as specified.
S & F LED INVERTER Rechargeable BULB 12Watt CDL with B 22 base capacity 1200 lumen with backup of minimum 5 hrs backup complete all as specified.
S & F sheet metal enclosure VTPN 04 way Double door Ready to use DBs - Provided with insulated vertical phase bus-bars |neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification labels With provision for 4 Pole MCCB as incomer and SP/SPN/TPN MCBs as outgoing complete all as specified and directed.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source Rated luminous efficacy (lumen/watt) > 11 and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 20 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade of aqequate dia 1.5 mtr long bend to required shape complete all as directed by Engineer-in-Charge.
S&F in repairs trim Cosmo surface round slim surface mounted LED panel light 12Watt Rated luminous efficacy (lumen/watt) > 110,6500K with premium diffuser to ensure glare free & even light distribution including surface module accessories and complete incl removal of old unsv fitting all as specified and as directed.
Supply ,Installation ,Testing & Commissioning of AC whole current, Single phase, Two wire, tamper proof, Smart Energy Meters with prepaid and postpaid facility, 240 Volts, 50 HZ, 10-60 Amps; with plug and play type and field swappable communication module; with LED/LCD Data display; manufactured confirming to IS 16444 & with BIS identification mark on Name Plate, with sealing arrangement as per relevant IS; Transparent Meter Box; with standard sealing material as required at site. Numer of such Meters along with meter box of four different makes out of Approved makes in MES.
Supply ,Installation ,Testing & Commissioning of AC whole current, Three phase, Four wire, tamper proof, Smart Energy Meters with prepaid and postpaid facility, 415 Volts, 50 HZ, 10-60 Amps; with plug and play type and field swappable communication module; with LED/LCD Data display; manufactured confirming to IS 16444 & with BIS identification mark on Name Plate, with sealing arrangement as per relevant IS; Transparent Meter Box; with standard sealing material as required at site. Numer of such Meters alongwith meter box of four different makes out of Approved makes in MES.
Installation of Meter Data Management System (MDM) is to be set up to support storage, archiving, retrieval & analysis of meter data and various other operational systems along with validation & verification algorithms.
S & F in repair Smart Fan Rod or Anti Suicide Fan Rod for ceiling fans 1200 /1400 mm sweep having following specifications /sizes in white color, Thickness of Rod = 1.84(+/-0.05) mm on zinc plated MS Pipe with zinc plated spring mechanism, MSME Tested for 15 Kg weight bearing capacity and breaking at impact load of 22Kg+ including drilling,mounting,brackets,anchors etc(If required) , the fan down rod opens from its center and spring hidden in pipe, expands to land person on ground safely complete all as specified and as directed by Engr-in-Charge.
SEWAGE DISPOSAL Supply, laying and testing of 200mm internal dia of DWC high density (HDPE) pipe ISI marked (with CM/L No) with and including all fittings and jointing materials for sewage line and laid in trenches as specified.
EXTERNAL ELECTRIC SUPPLY Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface incl GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and as directed.
S & F Junction Box for Street Lights of size 205x255x112 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66/67 protection and suitable size of "connectwell" stud teriminal (provision for socket bolting)- 04 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 02 No and mounted on security light pole with suitable bracket nuts, bolts including removal of exiting unsv all as specified .
Supply & laying , testing & commissioning of LT PVC insulated, 3 core copper Conductor 1100 Volt grade, cross-sectional area 1.5 Sqmm 3 core, connecting along security pole from Junction Box to Security light etc , complete all as specified and as directed.
Supply & Fixing street light bracket made of 32mm dia GI Pipe light grade upto 1.2mtr including two pairs of clamps made out of flat iron 40mm X6mm of sutable length complete all as specified and directed.
S & F Modular type TV Co-axial socket outlet –module in the modular MS/GI sheet box and cover plate including connections etc complete all as specified and as directed.
S & F Modular type RJ-11 telephone socket outlet 1-module in the modular MS/GI sheet box and cover plate including connections etc complete all as specified and as directed
BAYAJ UDDIN MAZUMDER (BID ID -3505413)
M/S MOHANPASARI (BID ID -3511933)
M/S SALO ENTERPRISES (BID ID -3505664)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.45 MB
TENDERDOCUMENTS8588.rar
Tender Documents • 5.90 MB
BOQ_830143.xls
BOQ • 0.26 MB
TDDRAWINGS.rar
Additional Documents • 3.00 MB
DRAWINGS1.rar
Additional Documents • 28.66 MB
DRAWINGS2.rar
Additional Documents • 33.52 MB
DRAWINGS3.rar
Additional Documents • 26.53 MB
DRAWINGS4.rar
Additional Documents • 23.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .