Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹43.2 L+₹12.6 L (41.2%)Rejected-Finance SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L2 | Rejected-Finance Rejected not being L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in cat b(i) as required in NIT |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
15 Oct 2020, 6:00 pmClosed
GE Kargil
GE Kargil Ladakh
SPL REP TO LT PANEL, HIGH MAST, STREET LIGHT, REPL CABLE AT 259 TC, 10 MAHAR, MTN BDE AND PROVN OF MW AND BOREWELL AT THASGAM DRASS
2020_MES_378742_1
GE/K-51/2020-21
Open Tender
Electrical and Maintenance Works
Works
180 days
GE Kargil
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Kargil
₹64,000
Yes
13 Nov 2020
18 Sept 2020
17 Oct 2020
18 Sept 2020
15 Oct 2020
3 Oct 2020
Amount
Excavation in trenches hard and dense soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of hard and danse soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line complete all as specified and directed
Returning filling in (soil) including spreading, leveling, watering and well ramming in layers not exceeding 25mm thick all as specified and directed by Engr-in-Charge
Removing excavated materials (soil) to a distance not exceeding 50m away from the starting point and depositing where directed at a level not exceeding 1.5m above all as specified and directed by Engr-in-Charge
S&F Sand cushioning of the underground cable complete as per SSR Part-I clause 19.75 all as specified and directed by Engr-in-Charge
Supplying and laying reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm laid dry over electric cable for protection, complete all as specified and directed by the Engr-in-Charge.
Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 4 core complete all as specified
All as per item No 6 above but cable size 2C x 16 Sqmm -ditto-
All as per item No 6 above but cable size 3.5C x 50 Sqmm -ditto-
All as per item No 6 above but cable size 3.5C x 95 Sqmm -ditto-
Taking out / down LT XLPE/PVC under ground cable off sizes from trenches, walls, , roofs including taking out brick layer ,sand cushion from trenches including disconnecting supply complete and levelling the area all as specified.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip size 32X6mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 15 MM dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
S&F LED street light 40 Watt Pressure die cast aluminium housing CAT PART- LSTS-40-CDL comprising of epoxy powder coated housing enclosed with glass cover in frame 40X1. watt LED mounted on MCPCB.of make Crompton or equvilent Havells, Vipro, Syska etc.
S&F LED flood light 150 Watt Pressure die cast aluminium housing CAT PART- LFL-150-CDL/60 Flood lighting luminaire with high power LED and unique flood optics to ensure uniform distribution of make Crompton or equvilent Havells, Wipro, Syska etc.
Replacement of trailing cable suitable for High Mast Light of size 16 sqmm 2 core from bottom to top and repair of pully assembly, winch bracket, Lantern carriage ring, wire rope, nuts and bolts and other connected works as directed by Engr-in-Charge.
S&F Change over switch (Side handle) of capacity 320 Amps , 3 phase, 4 Pole 415 volts, 50 Hz all as specified and directed by the Engr in charge
S&F Change over switch (Side handle) of capacity 160 Amps , 3 phase, 4 Pole 415 volts, 50 Hz all as specified and directed by the Engr in charge
Supply and fixing tubes light grade, galvanised with all fittings and fixed complete to wall 50mm dia
Straining and stretching of existing over head aluminium conductor steel reinforced (ACSR) of any size on HT/LT poles including binding and jointing the conductor with and including 14 SWG binding wire and jumpers connections with PG clamps, complete all as specified. and directed by Engr-in-Charge.
S&F LT spacer 4 ways made out of PVC material and suitable to work on 1100 volts complete all as specified and directed.
S&F stay assembly complete with accessories as shown in electgrical plate no 1 of SSR-2009 Part-I such as stay rod 20mm rod 1800 mm long mild steel galvanised stay plate complete all as specifieed and directed. Note : Loop type insulator stay clamps excavation and concrete shall be included in quoted rate
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type
S&F Insulator Pin type, porcelain , vitreous, white , brown or green, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut , 100 mm height, 65 mm dia. For 1100 volts grade complete all as specified.
S&F Sheet metal enclosure (CRCA sheet dust & vermin prooof) for DB's double door, single pole and neutral, 240V, 2 way with 200 Amp rated bus bar including blanking plates where required, complete all as specified and directed by Engr-in-Charge.
S&F isolator SPN 240 volt 40Amp complete including suitable size of copper lugs all as specified and directed by Engr-in-Charge.
S&F 1100 volts grade heavy duty 4 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm suspension , complete all as specified and directed by Engr-in-Charge.
S&F water heater Hamam of capacity 500 litre, iron body with 2 taps ouutlet run by Kerosen/Diesel electric driven blower of suitable size Model No WHH001 of LABORATE
Supply and install heater water storage type 5 star BEE cap 25 ltr electric operated 230 volts 50 Hz with tubular heating element as per IS 4159 automatic temperature control through thermal cutout as per manufacturer design fir retardent cable as per IS 0694 for wiring , pressure release valve for safety against extra pressure in tank , fine quality high density fibre glass insulation as heat preservation material fusible drain plug on extreme afety device and hot water inner tank made out of copper complete fixing on wall and suitable size of bolt grouted in wall and suitable size of nut and washers connecting by suitable PVC pipe for hot and cold water. Note - Rate quoted by contractor includes Geyser, PVC pipes, nut bolts, fixing and testing.
S & F single pole and neutral enclosure with two pin and earth plug and socket combination with one single pole MCB of 10A.
M & L for submain wiring with two single core 6 sqmm multistranded copper conductor cable,m PVC insulated unsheathed 1100 volts grade and 6 sqmm as continuous earth wire drawing in and including PVC casing and caping of suitable size with all accessories complete all as specified.
Supply, laying and testing of 3 layer PP-R(Polythene random copolymer) pipes of size 50mm SDR 7.4 & SDR 11 UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches
Supply, laying and testing of 3 layer PP-R(Polythene random copolymer) pipes of size 40 mm SDR 7.4 & SDR 11 UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches
Supply, laying and testing of 3 layer PP-R(Polythene random copolymer) pipes of size 32 mm SDR 7.4 & SDR 11 UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches
Supply, laying and testing of 3 layer PP-R(Polythene random copolymer) pipes of size 25 mm SDR 7.4 & SDR 11 UV stablished and antimicrobial fusion having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches
Supply and fixing PP-R gate valve of size 50mm(Brass insert in size) as per site requiremnet as directed and instructed by Engr-in - Charge
All as per item No 36 above but gate valve of size 32 mm -ditto-
All as per item No 36 above but gate valve of size 25 mm -ditto-
Drilling of Pilot (Trial) bore well for as per IS 2800 in any type of strata with DTH/ODEX/Rotary/Rig type method of 200 mm dia bore to deliver appx 5 LPS quantity of water i.e. yield for Depth upto 25M from GL complete all as specified and directed
All as per item No 39 above but depth exceeding 25M & not exceeding 50M from GL -ditto-
All as per item No 39 above but depth exceeding 50M & not exceeding 75M from GL -ditto-
All as per item No 15 above but depth exceeding 75M & not exceeding 80M from GL (In case the depth is increased beyond 80M as per tech site requirement, this rate shall be applicable for the increasing depth upto 90 M) -ditto-
Note for item No 39 to 42 (a) The rate quoted by the tenderers shall be deemed to include for tranportation of suitable truck mounted drilling attachment alongwith necessary accessories and T & P and also clearance for setting of machinary etc. (b) Second and third trial bores shall only be carried out in case the first and second trial bores respectively declared to be unsuccessful by the GE in writing. (c) Payment of unsuccessful trial bore(s) shall only be released after successful boring in the successive trial. However in the event of unsuccessful boring even after 3 Nos of trial bores if it is declared to be given up, the site will be abandoned & payment for all the trial bores will be allowed only after approval of accepting officer. (d) Rate applicable for payment of the second and third trial bore shall be 20 % less than the rates quoted against 1st trial bore (item No.1 ).
Development of trial bore well by reaming upto 525 mm dia in step of depth upto 25M from GL complete all as specified and directed
All as per item No 44 above but depth exceeding 25M & not exceeding 50M from GL -ditto-
All as per item No 44 above but depth exceeding 50M & not exceeding 75M from GL -ditto-
All as per item No 44 above but depth exceeding 75M & not exceeding 80M from GL -ditto-
Development of bore well by means of compressor of min 250 PSI capacity and over pumping by pump of capacity not less than 25 HP until the sand free water obtained and carrying out necessary yield test by V notch method and submitting the test report complete all as specified and directed. Note - The compressor/submarsile pump set and other equipment shall be arranged by contractor and cost of FOL for running of compressor is deemed to be included in the item rate.
Supply, assembling and lowering 300 mm nominal bore mild steel ERW ISI marked casing blank pipe having wall thickness 8 mm as per IS - 4270-1992 and jointing with electric arc welding, screwing and socketed in random length of 3 to 6 m, including necessary fittings i.e. special steel sockets, coupling , jointing and painting with two coats of bituminous paint of external surfaces of pipe upto depth of 25 M from GL complete all as specified and directed.
All as per item No 49 above but 200 mm nominal bore and depth exceeding 25M & not exceeding 50M from GL -ditto-
All as per item No 49 above but 200 mm nominal bore and depth exceeding 50M & not exceeding 75M from GL -ditto-
All as per item No 49 above but 200 mm nominal bore and depth exceeding 75M & not exceeding 80M from GL -ditto-
Supplying, assembling and lowering 200 mm nominal bore MS ERW fine cut having wall thickness 8 mm slotted pipe confirming to IS 4270-1992 with slot of suitable size and number as per location of intermediate aquifiers complete all as specified and directed. NOTE - Item qty and depth may vary depending upon the actual requirement at site.
S&F Mild steel casing shoe to be welded with MS ERW casing pipe of 200 mm nominal bore suitable for DTH/ODEX drilling complete all as specified and directed.
S&F pea gravel of size 3.0 mm to 6.00 mm of approved quality as in packing around casing/slotted pipe in borewell complete all as specified and directed. Note: Stack measurement will be recorded in MB for payment purpose.
S&F MS housing clamp made of MS flat iron of size 115cm x 20 cm x 2 cm to hold 100 mm dia MS column pipe at/or ground level including two coats of black bituminous paint over a coat of red oxide primer complete, all as specified and directed.
S&F MS well cap fabricated out of 6 mm thick MS Sheet having an internal threading and locking arrangement for 200 mm dia bore pipe in two pieces having 80 mm dia hole in centre with external bracket of flat iron of size 100 mm x 6 mm thick complete with nut, bolts and washers etc including painting over a coat of red oxide primer complete all as specified and directed.
M&L for PCC Foundation including earth work, excavation, removal etc for holding of tube well of size 100 x 100 x 100 cm at ground level made of precast cement concrete 1:2:4 type B2 (using 40 mm graded crushed stone aggregate), as directed.
Supply, install, lowering, testing and commissioning of submersible pump set of required 100 mtr head at discharge 200 LPM of suitable HP of pump set as per manufacture standard. Note- The rate quoted is deemed to be inclusive the cost necessary MS pipe and suitable accessories for connecting delivery lines to the delivery of pumpset so as to match the manufacturers
Supply & fixing fully automatic Star - delta motor starter in sheet steel enclosure 2 mm thick on MS frame box with provision for fixing / mounting on wall type MK, ML & MB motor rating upto 7.5 HP AC - 3 duty, 415 volts 50 Hz, 3 Ph for submersible pump and centrifugal pump, relay max range 7-10 Amps. ifor submerssible pump.
Supplying and fixing submersible copper conductor cable 3 core 10 sqmm 1100 volts flat including Nylon binding wire and accessories to clamp with column pipe at places to column pipe complete all as specified and directed.
Supply, lowering & fixing MS flanged Pipes medium grade of bore 80 mm with MS Flange of 10 mm thick including provision to cut for passing submersible cable and four no. holes 10 mm dia 3 meter length with suitable size of nut bolts washers and rubber gaskets complete all as specified and directed.
Note:- Deduction for amount of Rs. 24,835.00 as listed in Schedule A Part-II (Schedule of credit) shall be made while awarding of contract.
M/S SUN RISE BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .