| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.6 L+₹2.3 L (8.66%)Rejected-AOC 37 B SAHEB KRUPA SOC JIVAN CHETAN SCHOOL SAMA ROAD VADODARA GUJARAT PIN 390 008 | VADODARA | GUJARAT | 390008 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹29.9 L+₹3.6 L (13.8%)Rejected-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹37.4 L+₹11.1 L (42.1%)Rejected-AOC SHAMAL BECHAR S CHAWL SIDHANATH ROAD B H KHANDERAO MARKET VADODARA 390 001 GUJARAT | VADODARA | VADODARA | GUJARAT | 390001 | L4 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹71,000
Closing Date
12 Oct 2020, 6:00 pmClosed
GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2020_MES_377967_1
8541
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹71,000
Yes
28 Nov 2020
16 Sept 2020
14 Oct 2020
17 Sept 2020
12 Oct 2020
29 Sept 2020
19 Sept 2020 - 21 Sept 2020
Amount
Taking down carefully copper / Aluminium point wiring(light, fan, socket or power) including fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical, fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete.
Taking down carefully UNSV main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
M&L for Point wiring complete with 1.5 sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated unsheathed (FRLS) cable enclosed in PVC conduit with accessories ISI marked fixed on surface of walls/ceilings by means of PVC Sleeves / dash fastness and cadmium screws all as per IS fittings mounted on terminal box with 3 mm thick phenolic laminated sheet top cover concealed in wall. The thickness of sunken box shall be 1.2 mm. The cover shall be fixed to terminal box with brass screws incl 1.5 sqmm single core cmultistranded PVC insulated but unsheathed cable as earth continuity conductor to common earth dolly drawn in same conduit complete all as specified.
One light controlled by one switch 6 amp one way
One fan point controlled by one switch 6 amp one way
One bell point controlled by one switch 6 amp one way
One 3 pin switch socket combination 6 amp on the independent board.
One 3 pin switch & socket on same board with other switches.
One light point controlled by two way switches
All as described as per item No 3 above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade, conforming IS 694 & color code in conduit system of wiring, drawn in including medium grade PCV conduit not less than 20 mm dia concealed, including cutting chases, finising of slote by means of cement mortor making good to the existing surface of the wall & touching with the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.6mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet6 fixed with brass screw and washer with all accessories including single core solid conductor copper 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete.
One light controlled by one switch 6 amp one way
One fan point controlled by one switch 6 amp one way and fan regulator
One bell point controlled by one bell switch 6 amp one way
One 3 pin switch socket combination 6 amp on the independent board.
One 3 pin switch & socket on same board with other switches.
One light controlled by two way switch 6 amp
All as described as per item No 4 above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed FRLS multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including sunken junction box not less than 1.0 mm thick concealed in wall, mounting accessories like switches, sockets fan regulators with 2.7 mm thick Laminated sheet top covers etc including 1.5 Sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth dolly. for the following :-
One light/fan/bell point controlled by one switch 6 Amp one way
One 3 pin switch socket combination 6 amp on the independent board.
One 3 pin socket outlet on same board with other switches.
One light controlled by two way switch 6 amp
All as described as peritem No 5 above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 2.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
S&F TPN DBs 4 way with provision for FP as incomer and SP as outgoing all as directed. IP 43-IK 09 with metal double door of Make Legrand or its equivalent in Schnieder/ABB/C&S
S&F Distribution board SPN Double door including fixing and connecting of mounting MCBs isolator, ELCBs etc factory made, confirming to IS:13032 fabricated out of CRCA sheet. The DBs shall be of same make as MCBs /Isolator. DB shall also be provided with lable marking indicating the incoming and outgoing circuits on all way as specified.Make-Schneider/C&S/ABB
SPN 12 way
SPN 8 way
SPN 4 way
S&F in DB's MCB's/TPN/SPN/SP of 10/35 KA rupturing capacity conforming to IS-8828 of the undermentioned type and ratings:- Make-Schneider/C&S/ABB
TPN 63 Amps 10 KA rupturing capacity
MCB SPN 5 to 40 Amps.
MCB SP 5 to 40 Amps
M&L in repairs Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
M&L in repairs Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor. NOTE : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
S&F switch piano flush type single pole, one way 5/6 Amp, make: Anchor/SSK/Cona
S&F switch piano flush type single pole, two way 6amp, make: Anchor/SSK/Cona
S&F switch piano flush type single pole, one way 15/16 Amp, make: Anchor/SSK/Cona
S&F socket flush type 2 in 1, 3 pin, 5 and 15/16 Amp, make: Anchor/SSK/Cona
S&F socket flush type 2 in 1, 3 pin, 5 Amp, make: Anchor/SSK/Cona
S&F switch socket combination 5 pin 6 amp, make: Anchor/SSK/Cona
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal.Make-Anchor/SSK/Cona
S&F electronic type fan rgulator, not less than 100 watt single phase 230V comlete Make-Anchor/SSK/Cona
S&F flush type bell push 6 amp duly marked for bell complete.Make-Anchor/SSK/Cona
S&F Electronic ding dong bell AC 230V single pole .Make-Anchor/SSK/Cona
S&F lamp holder, PVC/Polycarbonate type and back plate suitable for batten fitting Make-Anchor/SSK/Cona
S&F in replacement capacitor 2.5 MFD capacity electronic type suitable for ceiling fan complete. Make:Havells/Tibcon
S&F electronic ballast for FTL of capacity 36/40 W, 230 volt of Make Wipro or equivalent in other specified makes complete Make:Havells/crompton/Bajaj
S&F tube light 36W/40W tubular fluorescent lamp, Lumens 2425, 5 BEE star rating, Make-Wipro/Philips/CG.
S&F Electronic ballast 18/20 watt of make Wipro/Philips/CG. Lighting.
S&F tube light 18W/20W tubular fluorescent lamp, Make-Wipro/Philips/CG.
S&F Electronic ballast 28 watt of make Wipro/Philips/CG. Lighting.
S&F tube light 28W tubular fluorescent lamp, Make-Wipro/Philips/CG.
S&F 9W LED Bulb suitable for B22 holder. Make: Philips/Wipro/Crompton
S&F 7W LED Bulb suitable for B22 holder .. Make: Philips/Wipro/Crompton
S&F 5W LED Bulb suitable for B22 holder .. Make: Philips/Wipro/Crompton
S&F 1x 4' feet 1X18W LED tube rod on replacing existing 36/40watt tube rod, electronic ballast at site as per user requirement,230V 50 Hz. The LED tube light conforms to applicable IS 10322/EN 60598, similar to Havells model No : PHOTONULTRA 1213T8SSTL18WLED865SPC, Make of Luminaire: Philips /Havells/Wipro.
S&F CFL 11 watt 2 pin-G24D2, DU tube square base, Make- Wipro/Crompton/Havells
S&F Electronic ballast suitable for 11 watt CFL of make Wipro/Philips/CG/Havells
S&F in repair main terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing size suitable for 8"x 12" bakelite sheet housing of fittings, switches, sockets outlets, regulators etc complete including making good with existing coulor of disturbed surfase of wall complete.
S&F in repair GI terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing size suitable for 7"x5" bakelite sheet mountinghousing of at least one switch sockets outlets 15 Amps etc complete including making good with existing coulor of disturbed surfase of wall complete.
S&F in repair GI terminal boxes made out of GI sheet,not less than 1.2 mm thick of existing size suitable for 5"x 5" bakelite sheet mounting housing of at least one switch sockets outlets 5 Amps etc complete including making good with existing coulor of disturbed surfase of wall complete.
S&F in repair bakelite laminated sheat top cover 3mm thick of 8"X12" size for mounting of fittings, switches, sockets outlets, regulators etc complete including refixing seviceable switches, switch sockets and regulators etc complete.
S&F in repair bakelite laminated sheat top cover 3mm thick of 7" X 4"size for mounting of switch sockets outlets 15 amp, etc complete including refixing seviceable switch sockets etc complete.
S&F in repair bakelite laminated sheat top cover 3mm thick of 5" X 4" size for mounting of switch sockets outlets 5 Amp etc complete including refixing seviceable switch sockets etc complete.
Supply only 1.5 sqmm PVC insulated overall PVC sheathed 3 core flexible cable for maintenance of tubelights and fans.
Dismantling damaged wooden boards of Electric meter by disconnecting all electric connection and S&F rectangular teak wood board of size 30cm x 25cm x 5cm deep with smooth hylem sheet top 5mm thick for mounting Electric Meter including making holes for incomming and outgoing wires and making necessary electrical connections complete.
Supply, Fixing, Testing and commissioning of 4' LED fitting not less than 1X18W LED Batten with LED tube rod not less than 18 watt. Similar to Batten cat Part No. REGALBATTEN8UPTO1X22wSSBSWH and LED tube light cat part No.PHOTONULTRA 1213T8SSTL18WLED865SPC of Make- Havells or equivalent in Make: Philips/Wipro/CG
Supply, Fixing, Testing & Commsioning of IP65 integral LED Bulk Head luminaire. Power Consumption should not exceed 10W (Including Driver Loss). Similar to cat Part No. RUGBYNEONFT10WLED760SSYMBOPC of Make- Havells or equivalent in Make: Philips/Wipro/CG
Supply, Fixing, Testing & Commisioning of 2' not less than 10W Mirror LED Batten .Mounting on two PVC square boxes of size not less than 75mm X 75mm complete including connecting fitting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose complete all as specified & directed. Make- Havells, Model-ENDURALINEARNEOBS10W LED 830SPCWH or equivalent in Wipro/Philips/CG
S&F wall security light LED type not less than 25W . The Luminaire connecting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose complete complete all as directed and specified by Engr-In-Charge. Make- Havells, Model-ENDURAPEARLSL25WLED757SASYTOPC or equivalent in Phillips/Wipro/CG.
M&L for replacement of 25 mm bore light grade GI pipe fixed as bracket, on wall any type, not less than 1.0 m long and bent to shape as required complete with sutiable clamp made out of 25x4mm Flat iron duly fixed 12mm dia nuts, bolts, washers etc.suitable for steel tubular / PCC pole complete.
Supply and laying or fixing or passing through pipe, XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 25 sq. mm 3.5 Core.
Supply and laying or fixing or passing through pipe, XLPE insulated armoured heavy duty electric cable with aluminium conducto1100 volts grade cross sectional area 16 sq. mm 4 Core.
Supply, installaing, connecting and testing electronic single phase AC energy (kWh) meter of accuracy class 1.0, Rating 10-60Ams, 240 volt, 50Hz, tamper proof type, 2 wire, with LCD Display, conforming IP54, including pilfer proof meter box with sealing screw provision and electric connection with existing cable complete and duly sealed as per model No SPPB15100000020C00 of Make HPL or equivalent model in L&T complete. Note : Old unserviceable meter shall be deposited to AGE E/M store yard through RV.
M&L for opening covers of ceiling fan, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bearings No 6201/6202 for 1200mm sweep, greasing, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5mfd and making connection with fan capacitor and connector block, transoporting back after repair, assembling the blades, painting and hanging the fan in its own position to existing fan clamp and down rod with necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site. Note : Quoted rate deems to inclusive of labour charges and items/jobs of fan rewinding, capacitor, fan bearing, servicing, painting, wire and transporatation charges.
M&L for opening covers of Exhaust fan 225/250/300mm, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armature coil with complete shaft, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan and making connections, transoporting back after repair, assembling the blades, painting and fixing the E/ fan in its own position with existing clamp with necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site. Note : 1. Quoted rate deems to inclusive of labour charges and items/jobs of fan rewinding, fan bearing, servicing, painting, wire and transporatation charges.
S&F of Exhaust fan 225 mm sweep with minimum airflow/air delivery 720 Cmh, 03 blades, light weight, rust proof body & blades, self opening louvers for protection from birds & rain water, IP-55, 230 Volt AC supply, rated power input not more that 45watt, connecting up including provison of cable from ceiling rose to fan. Make : Crompton Greaves, Model : Drift AIR or equivalent in Havells/CG/Bajaj. Note: Old UNSV ceiling fans will be deposited to AGE E/M office through RV.
Supply, fixing, testing & commissioning of exhaust fan 300 mm sweep with minimum airflow/air delivery 1710 Cmh, totally enclosed heavy duty motor, die cast aluminium rotor mounted on double ball bearing, IP-55, polarity-4, 230 Volt AC supply (single phase), rated power input not more that 90watt, with louvers and connecting up including provison of PVC insulated overall PVC sheathed copper conductor cable from ceiling rose to fan. Make : CG/Bajaj/Havells or equivalent. Similar to Crompton Greaves model No Transair 12" - Reversible, Note: Old UNSV ceiling fans will be deposited to AGE E/M office
S&F in repairs Sheet Metal Enclosure with socket plug top and MCBs double pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V, 20 Amps
S&F in replacement PVC casing and casing with accessories fixed on surface on walls/ceiling by means of PVC sleeves, Dash fastners and cadmium plated screws including putting in existing copper/aluminium cables complete all as specified and directed
M&L for KAPITRODE Earthing complete with Cast Iron pipe electrode, 75mm bore, 3.15mm wall thickness , 2.9 metres length,with GI pipe & funnel, buried directly and preferably vertically in ground with top edge not less than 2.9 metres below ground level connected with earthing lead of 25x5mm dia galvanised iron strip all as specified including testing on completion including the material and labour of the following, Make -Kapilansh Dhatu Udyog (P) Ltd or equivalent : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1 of size 450x450x450mm with Cast iron cover with suitable handle. (c) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (d) Requisite quantity of BFC Compound (bentonide powder) and black cotton soil. (e) Testing of earthing. NOTE :- On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction.
Supply and Installation of Single Phase AMR Enabled Bi Direction smart meter with the following specifications: • AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, current 10 A-60A conforming to IS-13779 and relevant IEC standards E10demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand • Meter should have connect / disconnect functionality operable from remote software • Meter should have a load limiting switch with the load limit operable from the remote software • Meter should support Tamper event and Power outage detection and reporting to remote software on regular basis Make: L&T, Capital, Cyantech Note: Old UNSV Meters will be deposited to AGE E/M office
Supply and Installation of Repeater unit with inbuilt Low Power Radio Frequency (LPRF) Communication Facility and capable of communicating within Cyantech Mesh network with inbuilt AC power supply. Make: L&T, Capital, Cyantech
Hosting and Configuration of the Web based Software with following modules: (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following functionalities: (a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency. (b) Monthly and quarterly billing survey data for cumulative energy and max demand. (c) Meter and Meter template setup. (d) Data validation and alert set-ups. (e) Daily and monthly consumption calculations. (f) Energy accounting calculations. (ii) Prepaid / Postpaid Disconnect Billing Module (for single phase and three phase smart meters) The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and calulate the final bills. It should support the following funtionalities: (a) Tariff Set-up including slabs and exemption (b) Billing product set up (mapping consumer ith the tariff) (c) Bill execution (d) Bill dispatch via print, email and sms. (e) payment collection from private and other consumers. (f) Auto diconnect on meter of payment default (iii) Occupation and Vacation Module - The system should support occupation and vacation of the officers as well as of other private consumers in the system (iv) Customer Portal - The occupant officers / customers should be able to view energy data and billing data on web portal as well as in android and IOS apps. (v) Communication - Email and SMS communication to users and consumers (vi) User Administration
M&L for providing suitable T&P and tradesmen to carry out IR/voltage drop/cricuit tests of complete internal wiring of complete One Qtr (Md Accn building) and filling all related columns of form as per Appx 'G' complete (Note : Rate deemed to be included for disconnecting all electrical connections and reconnecting the same after completion all specified tests and testing for smooth functioning after completion of Job)
M&L for providing suitable T&P and tradesmen to carry out Earth test of Earth pits of Md Accn building/Distribution boards and filling all related columns of form as per Appx 'H' complete (Note : Rate deemed to be included for disconnecting earth test point connections and reconnecting the same completion of Job)
S&F CFL 18 watt 2 pin-G24D2, DU tube square base, Make- Wipro/Crompton/Havells
S&F Electronic ballast suitable for 18 watt CFL of make Wipro/Philips/CG/Havells
Supply, installaing, connecting and testing electronic three phase AC energy (kWh) meter of accuracy class 1.0, Rating 10-60Ams, 3x 240 volt, 50Hz, tamper proof type, 2 wire, with LCD Display, conforming IP54, power consumption less than 1W including with transparent Hinge type meter box with sealing screw provision and electric connection with existing cable complete and duly sealed as per model No TPPB15100000020CN0 of Make HPL or equivalent model in L&T all as directed by Engineer-in-charge. Note : Old unserviceable meter shall be deposited to AGE E/M store yard through RV.
S&F 25 litre storage water heater, rated power consumption not more than 1500W, current leakage protection device, multi functional safety valve, high precision thermostat control, preset thermal output, high working pressure 0.8MPa ideal for high rise building, vertical mounting, Operating voltage 230 volts including all fittings complete & provision of flexible three core PVC insulated multi-stranded copper conductor cable, similar to Make : HAVELLS cat part No GHWASESWH025 or equivalent in Racold/Bajaj Note : Old unserviceable Geyser shall be deposited to AGE E/M store yard through RV.
Taking down and refixing storage type water heater (geyser) of 25/35 Ltr capacity (any type & Make ) from wall by disconnecting the electric connection and water inlet/outlet connection from supply end checking the serviceability of all parts such as inner vessel, rubber gasket, non return valve, heating element , thermostat etc. and refixing the same after replacing unserviceable parts of suitable capacity, painting of outer body and reassembling including testing for smooth functioning complete. Note : Quoted rate deems to inclusive of labour charges and items/jobs of geyser heating element, thermostate, indicator lamp and painting complete.
Taking down and refixing storage type water heater (geyser) of 50 Ltr capacity (any type & Make ) from wall by disconnecting the electric connection and water inlet/outlet connection from supply end checking the serviceability of all parts such as inner vessel ,rubber gasket non return valve , heating element , thermostat etc. and refixing the same after replacing unserviceable parts of suitable capacity, painting of outer body and reassembling including testing for smooth functioning complete. Note : Quoted rate deems to inclusive of labour charges and items/jobs of geyser heating element, thermostate, indicator lamp and painting complete.
S&F Modular type switch 1 way 6A, 1module, 230 V,AC 50Hz ISI Marked with valid CML No. complete all as per Make- Legrand or equivalent in Craptree or Anchor
S&F Modular type switch 1 way 20A, 1module, 230 V,AC 50Hz ISI Marked with valid CML No. complete all as per Make- Legrand or equivalent in Craptree or Anchor
S&F Modular type socket outlet multipurpose having provision for 3 pin 6A and 2 pin 6A, 2 module, 230 V,AC 50Hz ISI Marked with valid CML No. complete all as per Make- Legrand or equivalent in Craptree or Anchor
S&F Modular type socket outlet multipurpose having provision for 3 pin 16A and 3 pin 6A, 2 module, 230 V,AC 50Hz ISI Marked with valid CML No. complete all as per Make- Legrand or equivalent in Craptree, or Anchor
S&F Modular type Fan step regulator electronic type, 230V,120W - 2 module ISI marked with suitable CML No and connecting upto complete all as per Make- Legrand or equivalent in Craptree or Anchor
S&F Modular Bell push 6A 1 module, 230V all as per Make- Legrand or equivalent in Craptree /Anchor
Supply, testing and commissioning a low glare, high effeciency recessed mounted LED downlighter luminaire, Type : LED down light, systen Power consumption not more than 15W,Operating Voltage 170V-270V AC, Similar to Havells model No.EDGEPROSQDLR15WLED857S or its equivalent in Phillips/Wipro.
Supply, fixing, testing and commissioning Light source LED, Power consumption not more than 36W, Voltage 220-240V AC 50 Hz, Similar to Havells Make VENUSNEOHE2X2PLR36WLED8XXS or its equivalent in CG/Phillips/Wipro.
S&F LED High bay, 120W 5700K (NB), LED IP65 luminaire with high efficacy, including hanging arrangement (incl angle iron, clamp, nut, bolts fabrication etc)of the light from angle beam, Make- Havells, Model-BAYBRITESAUCERHBP120WLED757S90DTOLT G or equivalent in Phillips/Wipro/CG. Note for item No 1.00 to 77.00 : - (a) The contractor will collect complaint on daily basis and sufficient resouorces will be deployed by him/her for carryingout of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit suitable penalties shall apply as mentioned in relevant clause of Contract. (b) A detailed log of complaints with completion / non completion remarks duly signed by users / MES rep. will be maintained by the contractor and same will be updated on daily basis in consultation with Engr-in-charge or JE detailed by him. (c) The contractor will make suitable arrangement for emergent complaints and will notify auth rep / Engr-in-Charge about extraordinary circumstances for probable non completion or delay in rectification of complaints beyond state time limit set for disposal of complaint. In case of any dispute the decision of accepting officer wil be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rates deems to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Outram Line Area. (f) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed periodically to streamline complaints disposal system.
Pratik Enterprise
Gayatri Associates
M/s. RAMESH NARHARI VALEKAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .