Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹13.7 L+₹92,766.90 (7.27%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹13.7 L+₹92,862.70 (7.27%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹14.9 L+₹2.1 L (16.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹15.4 L+₹2.6 L (20.7%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
19 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
REPAIR MAINT OF LT NETWORK AND OTHER ALLIED WORKS AT ZONE I UNDER MIL STN SAMBA
2021_MES_438750_1
GE/SMB/T-05/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹40,000
Yes
13 Jul 2021
28 Apr 2021
21 May 2021
28 Apr 2021
19 May 2021
13 May 2021
28 Apr 2021 - 30 Apr 2021
60 days
Amount
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
All as per srl item No.1 above but depth exceeding 1.5 Mtr and not exceeding 3 mtr complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick in any type soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Sand cushioning to under ground cable upto 8 cm before laying the cable and 15 cm after laying and stretching the cable and punned down to form a bed to a minimum 23 cm.The punning shall be done by hand complete all as specified in clause 19.75 of SSR Part - I of 2009.
Sub class 'B' bricks well burnt of size 230mm x 115mm x 75mm laid dry flat for protection of cable complete all as specified and directed.
PCC 1:4:8 type D-2 using 40mm grade of stone aggregates as in foundation and mass concrete for foundation of poles complete all as specified and directed.
PCC 1:3:6 type C1 using 20 mm graded broken stone aggregate as in mass concrete in foundations for stay/copings etc complete all as specified and directed .
Supply & errect steel tubular swaged poles with MS base plate, finial taper plug as specified type 410 SP-31 (9.0 meter long) in truly vertical position and painting of steel tubular pole with one coat of red oxide primer above ground level , making black and white strips 30 cm high up to 1.5 mtrs above ground / coping with super enemalled paint and two coat of aluminium paint to remaining portion of pole . Before errecting steel tubular pole two coats black bitumins is applied on the surface to be burried in PCC complete all as specified and directed.(Earth work and PCC to be measured and paid separately)
Cross arms, bracing ,supports clamps, back plates fabricated from steel section incuding nuts,bolts and washers welding,drilling hole complete with two coats of aluminium paint over one coat of primer complete all as specified.
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed steel strip/wire armoured heavy duty 1100 volts grade of size 120 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed steel strip/wire armoured heavy duty 1100 volts grade of size 70 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed steel strip/wire armoured heavy duty 1100 volts grade of size 25 sqmm, 4 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed steel strip/wire armoured heavy duty 1100 volts grade of size 16 sqmm, 4 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
Supply and laying in trenches through pipe or under culvert of XPLE insulated PVC sheathed steel strip/wire armoured heavy duty 1100 volts grade of size 6 sqmm, 2 core with stranded aluminium conductor including proper connection to LT panel /bus bar with aluminium thimbles of suitable size /rating complete all as specified and directed by Engr-in-charge.(Note – necessary excavation, returning filling,removal of soil ,sand cushioning,brick work and GI pipe shall be measured and paid under respective item of Sch).
GI tubing light grade for passing through cables under the floor ,along the wall, along the pole 50 mm bore complete all as specified and directed .
GI tubing light grade for passing through cables under the floor ,along the wall, along the pole 40 mm bore complete all as specified and directed .
End termination joint suitable for armoured XLPE cable 1100 KV rating heat shrinkable type complete with jointing accessories including taking down the existing loop and cutting of faulty cable of size 16 sqmm to 25 sqmm ,3.5/4 core complete all as specified:- Make of joints: DENSON/3M/M-SEAL/VENUS
All as per item no 18 above but for size 35 sqmm to 50 sqmm, 3.5/4 core.
All as per item no 18 above but for size 70 sqmm to 120 sqmm, 3.5/4 core.
Cutting, trimming of hanging/ extended branches of trees upto a distance 3 meter from the overhead HT/LT line and making the line clear upto the entire length of the feeder including removal and disposal of the cut tree branches 50 meters away from the site complete all as specified and directed. Note : The Rates shall inclusive of T&P, hydraulic ladder, equipment such as motorised diesel operated hacksaw etc complete. One span comprises of 3 to 5 conductors of any distance between one pole to adjacent pole including trimming of all tree branches in vicinty & around poles /conductor & will be measured as one span. Necessary prior permission for shut down shall be obtained from concerned I/C JE E/M before carrying out the work. All safety measures & insurance to the staff undertaking the Job shall be the Contractor's responsibility.
Restringing/ restretching aluminium conductor on existing over head lines including necessary binding with binding wire with insulator , connections of incoming and out going cables complete all as specified and directed .
Taking down existing unserviceable /retrived old ACSR conductor from over head lines complete all as specified and directed.
Aluminum conductor steel reinforced (ACSR) for LT lines on steel tubular poles/PCC poles, streching without kinks and bends including aluminum binding wires, of size of conductor as per load, complete all as specified and directed by Engr-in charge .
Taking down unsv/dismantling insulators any type and size complete all as specified and directed.
Replacement of shackle type, procelain, vitreous, white, brown or green insulator including one galvanised iron steel straps, washer and insulator bolt dia 12 mm , washers, nuts one galvanised iron nut 75 mm height, 90 mm dia for 1100 volts grade .
Stay assembly complete with accessories as shown in electrical plate No. 1 of 16 mm dia complete all as specified and directed.
Replacement loop type insulator, vitreous porcelain, white brown or green with overall dimensions 65x90 mm clearance of hole 16 mm complete all as specified.
Galvanized stranded stay wire of size 7/4.00 mm including necessary binding with insulator, clamp and stay clamp complete all as specified and directed.
Aluminium lugs of suitable of size 50 Sqmm to be crimped properly to LT cable with crimping tool complete all as specified and directed.
Aluminium lugs of suitable of size 70 Sqmm to be crimped properly to LT cable with crimping tool complete all as specified and directed.
Aluminium lugs of suitable of size 95 Sqmm to be crimped properly to LT cable with crimping tool complete all as specified and directed.
Aluminium lugs of suitable of size 120 Sqmm to be crimped properly to LT cable with crimping tool complete all as specified and directed.
Aluminium lugs of suitable of size 185 Sqmm to be crimped properly to LT cable with crimping tool complete all as specified and directed.
Aluminium lugs of suitable of size 400 Sqmm to be crimped properly to LT cable with crimping tool complete all as specified and directed.
MCCB 250 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 25 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version) should be load line biased suitable for isolation. The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 25 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer, make: Siemens ( 3VL)/Legrand (DPX3)/ABB (Tmax), Schneider Compact (NSX)/L&T CM92109OON1OG, including taking out old U/S MCCBs from LT panels after proper shut down, Complete all as specified and as directed by Engr-in-Charge.
MCCB 100 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 16 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version) should be load line biased suitable for isolation. The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 16 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer, make: Siemens ( 3VL)/Legrand (DPX3)/ABB (Tmax), Schneider (NSX)/L&T CM91712OOKOOG, including taking out old U/S MCCBs from LT panels after proper shut down, Complete all as specified and as directed by Engr-in-Charge.
MCCB 63 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 16 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version) should be load line biased suitable for isolation. The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 16 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer, make: Siemens ( 3VL)/Legrand (DPX3)/ABB (Tmax), Schneider (NSX)/L&T CM91712OOKOOG, including taking out old U/S MCCBs from LT panels after proper shut down, Complete all as specified and as directed by Engr-in-Charge.
Digital volt meter with seletor switch (0-500 volt) including making electric connection by suitable size of multistranded copper conductor with thimbles including taking out old U/S Volt meter, complete all as specified and directed.
Digital amp meter with seletor switch (0-500 amp) including making electric connection by suitable size of multistranded copper conductor with thimbles including taking out old U/S Amp meter, complete all as specified and directed.
Replacement of LT busbar chamber box of minimum size 60 cm (Height) x 45 cm (Width) x 30 cm (Depth), outdoor type, double door type, front/rear opening type suitable for 415 volts, 3 phase, 4 wire (100% neutral), 50 Hz supply system all as specified and directed. Box made out of 3 mm (outer) & 2 mm (inner compartment door) CRCA sheet factory made wheather proof, dust proof and vermin proof duly powder coated with 04 Nos hindalco make aluminum busbar 200 Amps, 30 cm each (each busbar having 04 Nos of nuts, bolts, washers) horizentally placed on insulators suitable for & AC hinged and lockable door arrangement complete with interconnections with aluminium solid strips, busbar chamber mounted on angle iron 40x40x6 mm frame having 4 Nos legs 30 cm long of 50x50x6 mm angle iron, 15 cm grouted in PCC of ratio 1:2:4 and 30 cm clear space from ground level including fixed on angle iron frame complete all as specified and directed by Engineer-in-Charge. (Note: Panel shall be a front/rear opening with cable entry from the bottom).
Painting to LT steel pole of any size including cross arms and street light bracket ligt from top to bottom with two coat of synthetic aluminium enamel paint including 5 Nos 30cm wide strip of black and yellow paint with two coats of synthetic enamel paint alongwith writing word "LT", and pole No complete all as specified and directed by the Engineer in charge. (Note- T&P & ladder for painting will be deemed included in quoted rate)
Painting to LT PCC Pole of any size including cross arms and street light bracket ligt upto 1.5 metre height from bottom with two coat of synthetic aluminium enamel paint including 5 Nos 30cm wide strip of black and yellow paint with two coats of synthetic enamel paint alongwith writing word "LT", and pole No complete all as specified and directed by the Engineer in charge. (Note- T&P & ladder for painting will be deemed included in quoted rate)
Painting to LT panels/feeder pillar boxes outdoor/indoor type of any sizes or rating installed at varoius location under GE Samba with two coat of super enamelled paint of approved colour with spray painting after cleaning the surface and preparing the same for painting including welding work to LT panels/feeder pillar box shutters as per requirement at site complete all as spd and directed.Note : Required accessories like hings ,handle and allied items as per job requirement shall deemed in the quoted rates.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32X6mm by means of nuts bolts,washers,check nuts of GI steel all as shown in electric plate no 5 all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe ,medium grade 40mm and GI watering pipe 20mm ,medium grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected all as specified and as directed.
Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof and ground conductors and down conductors above ground complete all as specified and directed.
RAVI KUMAR
M/s Parv Enterprises
vishesh engineers
LAL CONSTRUCTIONS
G.M. ENGINEERING SERVICES
dinesh enterprises
bamral builder
Jiwan Singh
SIDDAHANT ENTERPRISES
Kay Bee Traders
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .