Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) NO 2 JODHPUR
GE (AF) No 2 Jodhpur
DAY TO DAY E/M MAINTENANCE IN AOR (ENTIRE DOMESTIC AREA, OTHER THAN OMQ , DAIMOND JUBILEE, MAP OFFICERS, CAMP AREA) UNDER AGE E/M, GE (AF) NO 2 JODHPUR
2020_MES_357990_1
8156/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF) NO 2 JODHPUR
AS PER TENDER DOCUMENTS.
6 documents required · 6 mandatory
₹500
Yes
GE (AF) NO 2 JODHPUR
₹70,000
Yes
3 Aug 2020
3 Jul 2020
1 Aug 2020
3 Jul 2020
30 Jul 2020
17 Jul 2020
60 days
Amount
M&L for disconnecting, taking down and refixing the same after repair the geyser of any cap including striping, utting the existing copper inner tank after welding, brazing and tightening the hold fast ,nuts, bolts, washers, Heating element,thermostat, safety valve,base assembly, inlet tank, bottom cover etc complete and including making good to disturbed existing surface with plastering all as dircted by Engr-in-Charge
Supply only Heating element of Geysers of 1.5 KW rating required at site including rubber washers. Make – Theeta/ Recold/Bajaj (ISI Marked)
All as per srl item No 2 above but 2 KW ordinary size
All as per srl item No 2 above but 2 KW roundal type 9 hole as per sample
Supply only thermostat for the Geyser of 25 ltr capacity ISI marked
All as per srl item No 5 above but 50 ltr capacity ISI marked
Supply only base assembly complete with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element inclusive of clamps for holding the element with nut and bolts, washer all as directed by EIC for Geyser of capacity 25 litre
All as per srl item No. 7 above but for cap 50 ltr complete ISI marked
Supply only GM non return valve 15mm dia and connecting up complete ISI marked
All as per item No 9 but size 20 mm dia complete ISI marked
Supply only safety valve/high pressure release valve for Geyser of 25 Litres capacity ISI marked
All as per item No 11 above but for cap 50 ltr complete ISI marked
Supply only PVC heavy duty hot type connecting pieces nylon braided with brass adopters 600 mm/450 mm long and fixing in position suitable for Geyser of 25/50 Litre capacity
Supply only copper connection heavy duty hot type connecting with 02 Nos brass adopters and washer of size 600 mm/450 mm long and fixing in position suitable for geyser of 25/50 litre capacity
Supply only pvc sheathe copper conductor multistranded cable ISI Marked 03 core PVC insulated of size 2.5 sqmm
Supply only plug top 3 pin 15 Amps ISI marked.
M&L for fusible plug suitable for 95 to 100 degree centigrade fix in brass socket for any capacity for 25/50 litre all as directed
M&L for single pole and neutral metal clad enclosures with a two pin and earth plug and socket complete with one single MCB 20 amps ‘C’ curve type and electrical connection all as directed by EIC as per Legrand Cat No 608741 or equivalent in CG/Havells.
Supply and fixing industrial type socket plug top including 3 Core x 2.5 Sqmm copper multi stranded 1.5m long including necessary connection all as directed by EIC.
Supply only 02 Nos of bottom cover suitable for any type/any size of Geyser.
Supply only geyser inlet tank made out of heavy duty copper body of capacity for 25 Litres.
All as per item No 21 above capacity for 50 Litres.
Supply only rubber ring for geyser 9 holes at site/MES store yard.
Supply only rubber ring for geyser round type at site/MES store yard.
Supply only geyser indicator lamp square type/round type
Supply only geyser glass wool stranded capacity for 25/50 Ltrs
Taking down Sub main wiring/ service connection any type / any size including pipe and all connecting accessories.
S&F sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 4 Sqmm 1100 volt grade drawn through in and including non metallic PVC conduit of size 20 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed on wall or ceiling etc. including 2.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire complete including repair / replacement of existing conduit size of clamps , screw saddle with base complete all fixing accessories all as directed by EIC and making good all disturbed surfaces to match with the existing surface.
S&F sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLS cable 2.5 Sqmm 1100 volt grade drawn through in and including non metallic PVC conduit of size 20 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed on wall or ceiling etc. including 1.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire complete including repair / replacement of existing conduit size of clamps , screw saddle with base complete all fixing accessories all as directed by EIC and making good all disturbed surfaces to match with the existing surface.
Taking down DB with MCB any type & single pole neutral enclosure with two pin and earth plug with MCB including all connecting accessories.
Taking down carefully aluminium/copper point wiring (light ,fan, socket or power)complete, including fittings & fixtures such as switches, ceiling roses, pendents, regulators, sockets,bell push,bell,light fittings etc.removing materials to store for keeping in safe costudy or for taking credit (credit for shall be made as per Sch of credit) and making good disturbed surface of walls, floors etc. to match to the existing surfaces.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and unwelded sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators One light point controlled by one switch complete all as specified and directed by Engineer in Charge.
One light/fan point controlled by one way switch.
One 3 pin 5or 6 Amps socket outlet on indipendent board with other switchs as directed.
all as above but on the same board.
One bell buzzer controlled by one push button in indipendent board .
One light point controlled by two 2 way switches.
M&L for point wiring with 2.5sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volts grade draw through in & including rigid MS conduit heavy duty concealed /surface conduit including conduit accessories like bends, tees junction boxes etc fixed on wall or ceilling etc including sunken type pressed steel terminal boxes of size 175 X 100 mm with 3 mm thick bakelite sheet cover white/coloured including 1.5 smm single core PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volts grade as earth continuity wire connected to main earth dolly, for one 3 pin 15 or 16 Amps socket outlet on independent board.
S&F in repair switch piano, flush type 230 Volt 5 amps single pole one way ISI marked all specified
S&F in repair switch piano, flush type 230 Volt 5 amps single pole two way ISI marked all specified
S&F in repair socket outlet 2 in 1, 5 pin 5 or 6 amps flush type all as specified.
M&L in repair for ceiling rose surfaces bakelite 65 x 50mm white coloured 2 to 3 terminals
S&F in repair angle holder, insulated polycabonate body with back plate complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
Supply and fixing fan electronic regulator step type all as specified and as directed by Engr-in-Charge. Make : Anchor, Legrand, Havells
S&F in repair Bell Push, flush type 5Amps 240 volt ISI marked
S&F in repair switch piano flush type 15 amps single pole one way ISI marked all specified
S&F in repair socket outlet 2 in 1, 6 pin6 Amps cum 16 Amps flush type all as specified.
S&F in repair electric Bell ding dong AC. 230volt single pole.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways. Make - Make - Legrand /Havells or equivalent in Schneider or Hager as approved.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways. Make -Make - Legrand /Havells or equivalent in Schneider or Hager as approved.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 12 ways. Make - Make - Legrand /Havells or equivalent in Schneider or Hager as approved.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with TPN, 415 volts, 4 ways. Make - Legrand /Havells or equivalent in Schneider or Hager as approved.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with TPN, 415 volts, 8 ways. Make - Make - Legrand /Havells or equivalent in Schneider or Hager as approved.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Single pole 6 to 32 amp. Make Legrand or equivalent model of Hyger/siemens.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of SPN 40 amp. Make Legrand or equivalent model of Hyger/siemens.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of DP 32A amp. Make Legrand or equivalent model of Hyger/siemens.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TP 63 amp. Make Legrand or equivalent model of Hyger/siemens.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 63 amp. Make Legrand or equivalent model of Hyger/siemens.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Four pole 63 amp. Make Legrand or equivalent model of Hyger/siemens.
S&F in repair energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required. Make - crompton cat ref no. LCTLR-36-FO-CDL or equivalent in Wipro or philips as approved.
S&F in repair LED Stud Bulk Head 10 watt fixture perfect interior and exterier application within car parks, walkway,stairwells, carridoers,local authorities and housing accosiation as well as commercial buildingincluding connection all as per cat ref no. LBHP-10-CDL complete all as specified and directed by Engineer in Charge. Make -Philips or equivalent CG/ Havells
M&L for taking down ceiling fan and refixing the same after repair including striping, cutting the existing copper winding of ceiling fans, rewinding with new heavy duty super enameled copper wire of appropriate gauge (Make-Devi Dayal/ SWAN /CHETAK/MUKATI/USHA with insulation material, varnishing, oiling, greasing, painting in white/grey colour with synthetic enamel paint, replacement of unserviceable other parts like clamps, nut, bolt, washer and locking arrangement, rubber reel, flexible wire, canopy, shaft, capacitor etc. testing complete all as specified and directed by Engineer-in Charge of the following sizes of ceiling fans of make - Usha, Orient, Bajaj, Crompton, Cool Home, Kessles etc.Note:- Replacement of unserviceable other parts like clamps, nut, bolt, washer and locking arrangement, rubber reel, flexible wire, canopy, shaft, capacitor etc. shall be measured & paid for separately as “supply only”.
1200/1400 mm (48"/56") sweep.
All as per item No. 58 above but exhaust fans of following sizes:-
230/300/400mm (9"/12")/12 sweep
Supply only Gun metal bush of ceiling fans any type of any sweep including cutting of grooves for fixing of bearing instead of bush any type/any size.
Supply only ball bearing of 1200 mm (48") sweep make: NBC/SKF/National suitable for ceiling fan.
Supply only ball bearing of make: NBC/SKF/National any sweep suitable for exhaust fans/pedestal fans of any make & size.
Supply only oil type condenser of Usha/Bajaj/Unistar Make, 230 volts AC including necessary soldering of capacity 2.5 MFD.
All as per item No.63 above but capacity 4 MFD for exhaust fans/pedestal fans.Make: Jamco/GEC/Crompton
M & L Rewinding of exhaust fan motor with copper winding & fixing. ISI marked suitable for existing size all as directed by Engineer-in-charge .Make CG/bajaj/Usha
M & L Rewinding of Ceiling fan with copper winding & fixing. ISI marked suitable for existing size all as directed by Engineer-in-charge .Make CG/bajaj/Usha
Supply only exhaust fan Blade ISI marked suitable for existing size all as directed by Engineer-in-charge .Make CG/bajaj/Usha
M & L painting of ceiling/exhaust fan necessary as per complete synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust and fixing in situ all complete fixing electrical connection by copper cable 23/0.0076 as directed by EIC.
Nvimal Engineer and Contractor
Dwarka Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .