Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-Finance PLOT NO 1235 JLPL SECTOR 82 SAS NAGAR MOHALI MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | L1 | Accepted-Finance accepted being L1 firm | |
| 2 | L2₹18.8 L+₹1.7 L (10.0%)Rejected-Finance | L2 | Rejected-Finance rejected being L2 firm |
Tender Value
₹24.2 L
EMD Value
₹43,900
Closing Date
27 Aug 2020, 10:00 amClosed
Executive Engineer, Electrical Division, HP.PWD Ma
Executive Engineer, Electrical Division, HP.PWD Mandi
Construction Additional Accommodation to Circuit House, Mandi District Mandi HP SH Providing VRF VRV System therein
2020_PWD_39732_1
PW/MED/TA/NIT/ e-notice/20-21-1947-53 dt 30.07.20
Open Tender
Electrical Works
Item Rate
365 days
Mandi
Please refer to bid document
11 documents required · 11 mandatory
₹500
Executive Engineer, Electrical Division, HP.PWD Ma
₹43,900
9 Sept 2020
13 Aug 2020
27 Aug 2020
13 Aug 2020
27 Aug 2020
13 Aug 2020
Amount
Supplying , Installation , testing & commissioning of VRF Type units air conditioning system complete with indoor & outdoor unitss with individual controller for cooling & heating type operation, system shall be BMS and airconditioning supply , installation of modular tyep VTF outdoor system , equipeed with efficient scrooll 100% invertor compressor , hot & cold both condenser fan auto check function for connection errror auto address setting of following capacity , outdoor shall be capable to operate in ambient conction(colling & heating )from -5 DegC:52 Deg C & from -15 DegCto 24 Deg C , VRF/VRV must be equiped with variable energey efficientuy regulation device feature which shall be enabling the ODU to perform in # models (Basic Mode/ Tourbo mode and high effeciency Mode ) with varied EER in all three modes. No De- Ration or capacity upto 39 Deg C: shall be in accordance to new Rama Guidelines ato dust removal , DC Motor drive for compressor motor and condensing fan brushless DC Fan motor , 0.5 watt stand by powewr , auto restart function . All round voltage , protection with volatge flactuation withstandable upto =/- 15% with enhanced DC inverter scroll compressor adn sub cooling circuit technology , , the UDU shall be capable to feed indoor units at as distance of 240 MRT , with an outdoor in indoor elevational difference 110 RMT and indoor to indoor Elevational diffenece of 30 RMT , the ODU shall be capabkle to have commulative piping pf 1000 RMT. Make :Mitsubishihi Electric / Voltas / O-General / Toshiba / Daikin / Samsung / Carrier / Hitachi / Blue Star / LG.
16 HP.: Must be Modular Type.Should have COP of 4.0@100% load and 6.2@50% load at AHRI Conditions. Including Outdoor T joint.
INDOOR UNITS OF VRF Make :Mitsubishihi Electric / Voltas / O-General / Toshiba / Daikin / Samsung / Carrier / Hitachi / Blue Star / LG. Supply , Lifting , shifting , positioning & installation of below mentioned Cassette unit with remotes
Supply , Lifting , shifting , positioning & installation of below mentioned Cassette unit with remotes
Refigerant Joints/ Headers:-
Supplying , Installation , testing & commissioning of imported Y joints , fititng to all indoor units all floors i/c alignements of joints complete as reqd.
Refrigerant Piping :- Supplying , Installation , testing & commissioning of Interconnecting refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications all piping inside the room shall be properly supported. Make :- RAJCO / MAXFLOW / TOTALINE / MANDEV ( Other standard make approved by Engieer- in- Charge.
34.9mm O.D (Insulation :19 mm)
28.6mm O.D (Insulation :19 mm)
22.2mm O.D (Insulation :19 mm)
19.1mm O.D (Insulation :13 mm)
15.9mm O.D (Insulation :13 mm)
12.7mm O.D (Insulation :13 mm)
9.5mm O.D (Insulation :13 mm)
6.4mm O.D (Insulation :13 mm)
DRAIN PIPING
Supplying & fixing of rigid PVC piping complete with fittings , supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation. i) 32 mm dia
Control & Transmissioning wiring
Supplying , Installation , testing & commissioning of Control cum Transmissioning wiring of 3 core x 1.5 sq mm copper wire in suitabel PVC Conduits between indoor & outdoor units to central remote controllere & fire connection between indoor units to remote control .
Supplying , Installation , testing & commissioning of MS Stand for the outdoor unis duly painted with black paint.
Supplying , Installation , testing & commissioning of GI Steel sheet ducting. i) 24 G
Supply , Installation , testing and commissioning of supply and return Air Grill.
Supply , Installation , testing and commissioning of Accoustic Lining.
Supply , Installation , testing and commissioning of Thermal Insulation 9mm thick Nitrile Rubber.
Supply , Installation , testing and commissioning of Canvas Connection.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required complete in respect.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required complete in respect.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required complete in respect.
Annual Maintenance of Cost.
Providing comprehensive maintenance for a period of five years including one year warranty bound from date of commissioning & handing over of the equipment to the owner as certified by the Engineer-in-Charge. The contractor shall guarantee the equipment against all deffects of materials and workmanship for the period of 5 years, including the compressor. Any deffects arising during this comprehensive maintenance period shall be rectified and made good by the vendor at his own risk and cost to the satisfaction owner the contractor will provide sufficient No of service/ operator team (available 12 hours) along with the service spares during the guarantee ( defect) period at site. Any defects, including drain, arising will be attended with in 24 hours. The rates coated by the contractor shall be complete including cost of all labour and material etc.
modern cooling solution
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .