| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 CrAccepted-AOC SUBHASH PALLY WARD NO 3 P O KOKRAJHAR P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM | KOKRAJHAR | ASSAM | 783331 | ₹3.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.3 Cr+₹1.7 L (0.50%)Rejected-Finance WARD NO 3 SUBHASHPALLY P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹3.3 Cr+₹1.7 L (0.50%) | L2 | Rejected-Finance QUOTED HIGH |
| 3 | L3₹3.3 Cr+₹3.3 L (1.00%)Rejected-Finance SUBHASH PALLY WARD NO 4 P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | ₹3.3 Cr+₹3.3 L (1.00%) | L3 | Rejected-Finance QUOTED HIGHEST |
Tender Value
₹3.3 Cr
EMD Value
₹6.6 L
Closing Date
12 Jan 2021, 3:00 pmClosed
The SE,PWD(R and B) Circle, Kokrajhar
O/o the SE,PWD(R and B) Circle, Kokrajhar
Construction of Sub-Regional Science Centre and Planetarium at Kokrajhar.
2021_BoTC_19882_1
TN 157 of 2020-21 157/1
Open Tender
Civil Works
Works
720 days
Kokrajhar
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
Yes
Principal Secretary, BTC
₹6.6 L
Yes
2 May 2021
2 Jan 2021
12 Jan 2021
2 Jan 2021
12 Jan 2021
2 Jan 2021
2 Jan 2021 - 12 Jan 2021
Amount
Fire Protection Work (A) (i) Construction of 1000 ltr. Capacity Over Head Water Tank: Earth work in excavation in foundation trenches wall, footing and column, steps, septic tank etc. including refilling the quantity as necessary...........as specified. (A) Up to a depth of 2.00m G.L (a) In ordinary soil
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified......complete. (c) In prop 1:3:6
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. Walling including straightening, cleaning, cutting, and bending to proper shapes and length as per...............etc. complete. (A) From primary producer (ii) Super Ductile.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting...................concrete work in. 3.2.1.1 Column, pillar, post & strut of square (a) Square rectangular, polygonal in plan or any shape like Tee/L etc. having plan vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting...................concrete work in. 3.2.1.2. Side and soffts of beam haunchings, cantilever girder, bressumers, lintels & horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting...................concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing & laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from............and paid separately) (I) Using mixture machine (a) In Sub-Structure up to plinth level a) In sub-structure up to plinth level. (a) M-20 Grade.
Providing & laying plain/reinforced cement concrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from............and paid separately) (I) Using mixture machine (b) In Super-Structure from plinth level upto 1st floor (ii) Column pillar past................1:2:4 Noising. (a) M-20 Grade.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub-structure of the plinth level. (c) In proporation 1:5
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick flat soling.
Earth/ sand filling in plinth in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land ...................as may be necessary. (c) River sand or silt
65mm thick cement concrete floor consisting of 53mm under layer of cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 coarse aggregate of 25mm and down) and 12mm thick wearing coarse of cement sand..................complete as directed.
15mm thick cement plaster in single coat on single coat or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and............................complete as directed. (B) On fair side (b) In Prop 1:4
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter. (i) Surface over 100mm in width or grith (ii) High Gloss (Asian paint)
Finishing wall with one coat of cement primer..........smooth.
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of berger paint of required shade after cleaning and cleaning the surface etc.
Supply fitting and fixing M.S angles,M.S. Angless M.S bolt and nuts including painting with red lead paint one coat complete as directed. (a) M.S angles
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 2000 Lt capacity (a) Sintex
Supplying fitting and fixing full way valve/country pit valve brand............specified. B) 40mm dia.
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches..............as directed. A) G.I pipe a) TATA v) 40mm dia
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches..............as directed. A) G.I pipe a) TATA ii) 25mm dia
(ii) Under Ground Water Reservoir with Pump House: Earth work in excavation for foundation trenches of walls, retaining walls, footing of colums, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work, breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level.
Supplying and filling sand gravel in foundation trenches of column footings over slussy soil including local carriage of materials within 8 Km pumping out of water, ramming etc.complete for strengthening the bearing capacity of the soil as directed and specfiied including payment of forest royalty and sales tax and other duties and taxes as may be necessary.
Extra lead per km truck carriage for sand gravel beyond the initial lead of 8 km.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand coarse aggregate by volume.
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Using Mixter Machine (b) In Sub structure up to plinth level. Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level.
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Using Mixter Machine i) Super structure from plinth level up to 1st floor level. Providing thickness not less than 100mm including attached pillasters buttesses plinth and string course etc. M20 grade concrete or prop.1:1.5:3
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Using Mixter Machine (b) In Sub structure up to plinth level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill, band,beam,girder,bressumer,cantilever, staircase (except spiral stair case and landing) including preparing the top surface & finishing of nosing. (b) M-20 grade concrete or Prop 1:1.5:3
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1 Column, pillar, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plan vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Side and soffts of beams, beam haunchings, cantilever girders, bressumers, lintel and horizontal ties.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, chajjas, balconles and the like. (a) Floors etc. upto 200mm in thickness.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.6. Vertical surface such as walls (any thickness) parapet walls, partitions and the like including attached pilasters, brtresses, plinth and string course and the like.
Providing form work of 12mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level. (a) Thickness not exceeding 200mm.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
25 mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12mm nominal size) finished with a floating coat of neat cement finish to be laid in panels including curing etc. complete as directed.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. c) In cement mortar 1:3
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. c) In cement mortar 1:3
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). (i) 9.5mm thick
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) (a) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50mm thick
Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. (iii) 0.50mm thick
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
Flush door shutter both side teak (greenply)……..
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with Plastic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Plastic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of nerolac paints limited of required shade on old/new wall surface to give an even shade after cleaning and cleaning the surface etc.including scaffolding complete as directed at all levels (two coats)
Applying priming coat over new wood and wood bassed surfaces over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (a) With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter sand papering and stopping. Surfaces over 100mm in width or girth. High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface up to 100mm in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter. Surfaces over 100mm in width or girth. High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) A. Sliding door bolts ii) 250mm x16mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) B. Tower bolts iii) 200mm x12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) C. Door handles iiz) 150mm
Providing and fixing plain with special metel, sachuputty and glazing clip in steel window/doors/cleastory windows including necessary cutting to required sized for all floors. (i) Clear sheet glass panes (v) 5.00mmthick.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening,cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks,supprots,chairs,spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) approved super ductile TMT Bar
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. circular hollow section conforming to relevent I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and two coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (b) Using other ISI marked approved circular hollow section.
Providing fitting and fixing steel windows of standard rolled steel sections as per relevent I.S Code joints mitred and welded with 15mm x 13mm x 100mm lugs embedded in cement concrete block of M-10 grade including providing and fixing projecting hinges (not more than 65mm and less than 15mm wide) bolting device.steel handles pegs stays of 300mm long etc. complete including providing 12mmx12mm sq bars duly welded to steel frame at not more than 12cm c/c applying a priming coat of red-lead etc. complete as per drawing. a) Openable.
Supplying and fitting and fixing door frame of M.S equal angle of size 40mm x 40mm x 5mm fabricated , welded, mitred and joined as per relevent I.S Codes including fitting 8 nos. of M.S hold fast providing closting/holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame applying primer to all steel surfaces fixing the frame to the wall/R.C.C members by embedding the hold fast securely in C.C block of M-15 grade complete at all levels as specified and directed. (Door hings to be paid as per relevent iteam of the sechedule of rates)
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1.4 admixed with modified styrene Butadiene rubber based polymer like sika latex of sika india ltd.Dr. Sealkit masterbond latex (asian chemicals)/rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
(iii) Fire Alam Detection System: Supply, installation testing commission of loop card for addressable panels make MORLEY/FIRELITE/Apollo or equivalent as approved by the deptt.
Supply, installation, testing, commission of addressable input/output moudule brand: MORLEY/FIRELITE/Apollo or equivalent as approved by the deptt.
Supply, installation, testing, commission of addressable loop isolator brand: MORLEY/FIRELITE/Apollo or equivalent as approved by the deptt.
Supply installation testing commission of response indicator.
Supply, installation, testing, commission of Monitor Module. UL/LPCB approved make Honeywell, MORLEY IAS or equivalent as approved by the deptt.) with housing box
Supply, installation, testing, commission of Addressable Hooter/SOUNDER: UL/LPCB approved, make Honeywell, MORLEY IAS or equivalent as approved by the deptt.)
Supply, installation, testing, commission of manual pull station with addressable interface, built in LED with key reset facility UL/LPCB listed make: Honeywell, MORLEY IAS or equivalent as approved by the deptt.)
Supply, installation, testing, commission of intelligent plug in photo electric Multi Criteria Detectors having features like integral communication, dual LED for 360 viewing angle, walk test with address display etc. UL/LPCB listed make: Honeywell, MORLEY IAS or equivalent as approved by the deptt.)
Supply, installation, testing, commission of 5 Loop Inte;;igent/Analogue Addressable Fire Alam Panel Microprocessor based character display Network option built in alam, trouble & supervisory relays LPCB listed make: Honeywell, MORLEY IAS or equivalent as approved by the deptt.)
Supply, installation, testing, commission of Addressable Base Model-Detectors, LPCB approved, make Honeywell, MORLEY IAS or equivalent as approved by the deptt.)
Supply, installation, of photo Luminescent exit board in RED/GREEN colour of size 300 x 150mm
Supply & fixing of 2x1.5sq.mm PVC insulated copper amoured cable on surface/reces/above false etc as required (ISI marked)
Supply, installation, testing, commission of Addressable/Convectional Beam Detector with Reflector Brand: MORLEY/FIREITE/Apollo or equivalent as approved by the deptt.)
(iv) Fire-Fighting Electrical Work: Providing,Fixing, testing &Commissioning of Single Headed stainless steel ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories as per IS:5290-19833 (Type-'A') and specifications complete as reequired . (MAKE:ESSEL/WINCO/NEWAGE/AttackFire/Getech)
Providing RLR Hose wiath ISI Marked (IS:636) 63 mm dia X15 M long complete with instantaneous type Stainless Steel 63 mm dia ISI Marked male & female couplings (IS"903) bound & riveted to hose pipe with copper river and copper wire complete as reqd. (MAKE:NIRMAL RUBBER/NEWAGE/Getech)
Providing & fixing of weather proof hose cabinet fabricated from 16 S.W.G. M.S Sheet with centre opening full front glass door and locking arrangement suitable to accomodate one landing valve (Yard Hydrant) 2 nos, 15m long hose and 1 no. Branch pipe with nozzle. The Cabinet shall be painted with one coat of primer and 2 or more coats of synthetic enamel paint of approved make and shade and shall be suitable mounted on a rised masonary platform complete as required. (Makeself Fabricated) a) 900X600X450
Providing & Fixing of Stainless Steel 63 mm dia Short Branch pipe with 20 mm dia nozzle, ISI marked (IS:903) complete as required. (Make:ESSEL/WINCO/NEWAGE/AttackFire/Getech)
Providing & Fixing of Gun Metal fire Brigade Connection (inlet collection head) consisting of 63 mm instantaneous type male coupling with built in check valves and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904-1983 complete as reqd. MAKE:ESSEL/WINCO/NEWAGE/Getech a) 02 way
Providing & Fixing of Gun Metal fire Brigade Connection (inlet collection head) consisting of 63 mm instantaneous type male coupling with built in check valves and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904-1983 complete as reqd. MAKE:ESSEL/WINCO/NEWAGE/Getech a) 04 way
Providing & fixing of weather proof M.S. cabinet (to enclose above Inlet Collection Head Connection) fabricated from 16 S.W.G. M.S> Sheet with centre opening with 3 mm thick full front glass door and locking arrangement duly painted with one coat of primer and two or more coasts of synthetic enamel paint of approved make and shade and suitably mounted. Exact size and shape shall be subject to site condition and prior approval. (Make:Self Fabricated)
Providing & fixing of Gun Metal fire Brigade suction hose coupling (draw out connection) with not for female coupling as per IS:902-1974 complete with 150 mm dia GI suction pipe and foot valve (to be connected to state Tank) complete as reqd. (Make:Self Fabricated)
Providing, Fixing, Testing & Commisioning of air Release Valve a) 25 mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Blackb pipe (IS:1239 part-I) Medium class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/slabs and naking good the same to the approval of Engineer-in-charge/consultant complete including painting with one coat of primer and two or moro coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) a) 200mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Blackb pipe (IS:1239 part-I) Medium class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/slabs and naking good the same to the approval of Engineer-in-charge/consultant complete including painting with one coat of primer and two or moro coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) e) 100mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Blackb pipe (IS:1239 part-I) Medium class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/slabs and naking good the same to the approval of Engineer-in-charge/consultant complete including painting with one coat of primer and two or moro coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) d) 80mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Blackb pipe (IS:1239 part-I) Medium class including cutting, screwing, welding etc. complete with all fittings (butt welded) viz flangers, bends, tees, elbow, reducers etc including excavation (upto 1.5m Deep), back filling and removal of surplus soil & providing and corrosive treatment (coating and wrapping) as per IS: 10221 with 4mm thick tape complete as reqd. (Make:TATA/JINDAL/NEZONE) b) 150mm dia
Providing, Fixing, Testing & Commissioning of Mild Steel Blackb pipe (IS:1239 part-I) Medium class including cutting, screwing, welding etc. complete with all fittings (butt welded) viz flangers, bends, tees, elbow, reducers etc including excavation (upto 1.5m Deep), back filling and removal of surplus soil & providing and corrosive treatment (coating and wrapping) as per IS: 10221 with 4mm thick tape complete as reqd. (Make:TATA/JINDAL/NEZONE) d) 80mm dia
Supplying & fixing cost iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco/Kartar/Getech) a) 150mm dia
Supplying & fixing cost iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco/Kartar/Getech) b) 100mm dia
Supplying & fixing cost iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco/Kartar/Getech) c) 80mm dia
Supplying & fixing cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc.(IS:13095) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco/Kartar/Getech) a) 150mm dia
Supplying & fixing cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc.(IS:13095) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco/Kartar/Getech) b) 100mm dia
Supplying & fixing cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc.(IS:13095) of following sizes complete as reqd. (Make:Koley/Kalpana/Audco/Kartar/Getech) c) 80mm dia
Providing, Fixing, Testing & Commissioning of G.M. Stop Valve ISI Marked screwed type tested to 30Kg/cm2 pressure as per IS:778-1984 of following sizes complete as reqd. b) 25mm dia
Providing, erection testing, Commissioning of cast Iron Foot Valve/Stainer confirming to IS:4038/1538 complete with flanges, nuts, bolts and washer etc as reqd. b) 150mm dia
Supplying, Installation, Testing & Commissioning of First Aid Hose reel drawn with 30 Mtrs. LOng rubber hose and G.M shut off nozzle, 25mm dia Gate valve, Union pipe complete set confirming to IS:884.
Fire Extingusiher Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS: 15683 with ISI Mark (4.5 LITERS) BRAND: FIRESTOP/FIREND/FIRESHELD/Attack Fire/Getech.
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built-in pressure Gauge to know the Ready ness of the fixtinguisher Squeceze Grip Handle As per IS:15683 with ISI mark. (6 kg capacity) BRAND: FIRESTOP/FIREND/FIRESHELD/Attack Fire/Getech.
SITC of pressure guage 0-150 PSI runge. 3/8" BSP botton entry 6" dial weather proof with stainless steel internals, siphon tube and gate valve including fittings, etc. complete as required.
SITC of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phophor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suitable for maximum pressure range of 230 PSI with isolation cock and interconnecting cables using copper conductor between pressure switch and panels completed as required.
Supply, Election, Testing & commissioning of water type butterfly valves Suitable for fitting between pipe flanges with body of cast iron, body lining of black nitrile rubber, dise of S.G. Iron, coated with nylon, with flow control lever, PN-16 rating. A) 200 mm dia
Supply, Election, Testing & commissioning of water type butterfly valves Suitable for fitting between pipe flanges with body of cast iron, body lining of black nitrile rubber, dise of S.G. Iron, coated with nylon, with flow control lever, PN-16 rating. b) 150 mm dia
Supply, Election, Testing & commissioning of water type butterfly valves Suitable for fitting between pipe flanges with body of cast iron, body lining of black nitrile rubber, dise of S.G. Iron, coated with nylon, with flow control lever, PN-16 rating. b) 100 mm dia
Supply, Election, Testing & commissioning of water type butterfly valves Suitable for fitting between pipe flanges with body of cast iron, body lining of black nitrile rubber, dise of S.G. Iron, coated with nylon, with flow control lever, PN-16 rating. b) 80 mm dia
Supply, Erection, Testing & Commissioning of non return valve (CIDF) conforming to IS 5312 with flanges, nut, bolts & Washers. A) 200mm dia
Supply, Erection, Testing & Commissioning of non return valve (CIDF) conforming to IS 5312 with flanges, nut, bolts & Washers. B) 150mm dia
Supply, Erection, Testing & Commissioning of non return valve (CIDF) conforming to IS 5312 with flanges, nut, bolts & Washers. C) 100mm dia
Supply, Erection, Testing & Commissioning of non return valve (CIDF) conforming to IS 5312 with flanges, nut, bolts & Washers. D) 80mm dia
CABLES AND CABLING Supply and laying of following size OF XLPE insulated and PVC sheathed, Aluminium conductor around power cable of 1.1 KV grade conforming to IS:1554-1 amended upto date. a) 3.5 Core x 300 sq. mm
CABLES AND CABLING Supply and laying of following size OF XLPE insulated and PVC sheathed, Aluminium conductor around power cable of 1.1 KV grade conforming to IS:1554-1 amended upto date. b) 3 Core x 16 Sq. mm
CABLES AND CABLING Supply and laying of following size OF XLPE insulated and PVC sheathed, Aluminium conductor around power cable of 1.1 KV grade conforming to IS:1554-1 amended upto date. c) 3 Core x 50 Sq. mm
CABLES AND CABLING Supply and laying of following size OF XLPE insulated and PVC sheathed, Aluminium conductor around power cable of 1.1 KV grade conforming to IS:1554-1 amended upto date. d) 10 Core x 2 Sq. mm
CABLES AND CABLING Supply and laying of following size OF XLPE insulated and PVC sheathed, Aluminium conductor around power cable of 1.1 KV grade conforming to IS:1554-1 amended upto date. CABLE TRAY FOR PUMP HOUSE a) 300mm x 3 meters
SITC of Air Release Valve 50mm dia
Sump Pump with Sensor for Automatic in opration.
MOTOR DRIVEN MAIN PIMP Supply, Erection, Testing & Commissioning of Electrical Motor Driven Pump centrifugel end section type pump complete with bronze impleller, mechanical seat capable of delivering 2280 liters/minute against a total head of 70 metres, induction motor suitable for 415V, 50Hz, AC Supply with 60HP with speed of 2900 RPM , TEFC type conforming to IP:55, flexible coupling, coupling guard, common bedplate fabricated from mild steel channel, vibration pads, isolation arrangement & RCC foundation.
DISEL ENGINE DRIVEN FIRE PUMP Supply, Erection, Testing & Commissioning of Disel Engine Driven Pump Horizontal end section, centrifugal type pump complete with bronze impeller, mechanical seal capable of delivering 2280 liters/minute against a total head of 70 metres, Disel Engine Min Cap of 93 BHP with speed of 1800 RPM, flexible coupling guard common bed plate fabricated from mild steel channel starter motor, batte, ies, battery charge & cabling, fuel piping, instrumental panel, exhaust piping with residential type silencer, cooling arrangements including 200 Litres Disel Tank Complete, vibration pads, isolation arrangement, heat exchanger & RCC foundation.
JOCKEY PUMPS: Supply, Erection, Testing & Commissioning of Jockey Pump Horizontal end section, single stage centrifugal type pump complete with bronze impeller, mechanical seal capable of delivering 180 liters/minute against a total head of 70 metres, induction motor suitable for 415V, 50Hz, Min 15 HP with 2900 RPM, TEFC type conforming to IP:55, fleible coupling, coupling guard common bedplate fabricated from mild steel channel, vibration pads isolation arrangement & RCC foundation.
(B) Construction of Generator Shed: Earth work in excavation in foundation trenches of wall, footing and column, steps, septic tank etc. including refilling the quantity as necessary.............as specified. (A) Up to a depth of 2.00m ground level. (a) In ordinary soil
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick flat soling
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified.............complete. (a) In prop 1:3:6
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts.................
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black tubes conforming to relevant I.S. coat, as per approved designed and drawing................. as directed. b) Using other ISI marked.
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping.........the Department. (b) 0.50 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. (i) 0.50 mm thick
Steel work welded in bult up sections, framed work including cutting, hoisting and fixing in position and applying priming coat of red-lead paint including drilling holes, supplying, fitting and fixing with bolts and nuts or welding if necessary as directed. a) In beams..............cleat.
Supplying fitting and fixing M.S angles MS flat MS bolts and nut including painting with red lead paint one complete as directed. c) MS bolts & nuts.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolic) to give an even shade including cleaning the surface of all dirt dust and other foreign matter. (a) Surfaces over 100mm in width or girth (ii) High gloss (Asian paint/Berger paint/ ICI paint/J & N paint/Nerolac). (i) Surfaces girth (b) High gloss (Asain paint)
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles, not exceeding 80 mm in girth and.............complete as directed. (b) In cement 1:4
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem ''Rakshak'' brand required shade by thining 1ltr of paint with 750ml of water to give an even shade after...................the department.
(C) Re-Painting of Boundary Wall: Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. b) High gloss (Asian paint/Berger paint/ICI paint/ J & N paint/Nerolac). (i) Surfaces purpose 100mm in width or girth. b) High gloss.
(D) Construction of Canteen: Earth work in excavation for foundation trenches of walls, retaining walls.footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work. breaking clods in return filling dressing. watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil.
Earth/Sand filling in plinth in layer not more than 150mm thick including necessary, carriage, watering, raming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. With river sand or silt (predominently non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees if any monopoly duty etc. (profile meassurement to be taken and 12.5% deduction for shrinkage to be made from total quantuty) etc. complete as per directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned. (b) Other than Guwahati city
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) In Prop. 1:3:6 (1 cement :3 coarse sand: 6 aggregate. by volume.(using mixture machine)
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. complete. 50mm thick
Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
Plain cement concrete aprone in prop 1:4:8 with 20mm down graded coarse agg. Over soiling including neat cement finish ising slurry 2.5kg/m2 of floor (solng to be measured separately) (b) 50mm thick.
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Using Mixture Matchine In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. Without using admixture, plasticiser
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Using Mixture Matchine (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill, band,beam,girder,bressumer,cantilever, staircase (except spiral stair case and landing) including preparing the top surface & finishing of nosing. Without using admixture, plasticiser
Extra for using plasticiser in concrete if admixture, plasticiser etc.are not included in the item rate. M20 grade concrete or Prop.1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 38mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: (a) Sides of tie beams, grade beams etc. at or below ground level. Using 38mm thick plank
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face in Ground floor. Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: a) Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties for depth not exceeding 1.0M. In Ground Floor
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like for floors etc.. Upto 200mm in thickness. In Ground Floor
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). TMT-Corrosion Resistant Steel (Fe-500) reinforcement bar (TATA/SAIL) In foundation & Plinth
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. USing TATA make RHS/SHS of Grade 310 conforming to relevent IS: code 4923:1997
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (c) In prop 1:5
(I) In Super-Structure above plinth level up to 1st floor level. B) In proporation 1:4 (1 cement: 4 sand)
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) 112mm thick brick wall In cement mortar in proporation 1:4
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. On fair side in cement mortar 1:4 for internal wall plastering in ground floor.
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. On rought side In cement mortar 1:4
Extra over item no. 31 & 32 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement slurry mixed withapproved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the department) (Walls means both interior and exterior walls). Delux range-Somany/Orient/Nitco/Varmora Make-Of size 300mm x 600mm and above
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement complete at all level as specified and directed. -Ceramic Tiles- Executive range-2 (sizes 600 mm x 600mm and above).
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. CERAMIC Normal range (Sizes 300 mm x 300mm and above) Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate.
Providing Pre Painted Galvanized iron sheet (PPGI) at all levels including fitting and fixing with self drilling self tapping screws complete.(Roof truss, purlins etc. to be measured and paid separately.) TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department. (ii) 0.45 mm thick
Providing Pre Painted Galvanized iron sheet (PPGI) accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing, self drilling, self tapping screws complete. TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department. 0.45 mm thick
Providing fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the botton of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete work etc. complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). 1.60mm thick sheet Size 125mm x 60mm (Single rebate)
Providing fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber , 25mm core battens 2.5mm to 3.5mm uniformaly thick cross bands style & rails made from hardwood timber of width not less than 50mm fixed to the door frames (chowkath) with necessary hings, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) (ii) 40 mm thick
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Tower bolts 300 x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Tower bolts 250x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Door handles 100mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Tower bolts 150mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Mortice lock vertical type 100mm (Godrej) with handle (6 lever)
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Door stopper with rubber stopper
FRP FRAME providing & fixing of factory made Fibreglass Reinforced Plastic (FRP) door frame of FIBREWAYS three legged of cross section 90mmx 45mm having single rebet of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame moulded with fire retaedant grade unsaturated polyster resin and chopped mat. Door frame laminate and shall be filled with suitable wooden block in all the three legs the frame shall be covered with covered glass from all sides. MS stay shall be provided at the bottom to steady the frame.
FRP FLUSH DOOR Supplying & fixing of factory made 30mm thick Fibreglass Reinforced Plastic (FRP) panneled door shutter of required colour of FIBREWAYS made with fire retardant grade unsatured polyster resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fitting, cast monolithically with 5mm thick FRP laminate for panels and conforming to IS:14856-2000 including fixing to frames complete as per direction of Engineer-in charge.
Providing fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. Omamental Grill- Fixed to Brickwork/P.C.C/R.C.C
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand (Hindalco/Nalco/Jindal/B2066Balco or equivalent primary producer) without horizontal glazing bars joints mitred and welded relevent to standard IS specifications fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, angle cleat rubber gasket, bolting device, locking assangements, screw etc as required complete as specified and directed for all levels. (cement concrete to be measured and paid separately) 6mm clear glass a) Side hung and Top hung windows and ventilators 5mm frosted glass
DISTEMPERING Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including, a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from mortar droppimgs and other foreign matter and including preparing surface even and sand papered somooth. Priming coat with distemper primer
DISTEMPERING Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including, a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from mortar droppimgs and other foreign matter and including preparing surface even and sand papered somooth. Top coat
Applying one self-priming coat of acrylic emulsion paint of approved brand, thinning by adding water as per the specification of manufacture over freshly plastered wall surface after throughly brooming the surfaces free from mortar droopings and other foreign matter and including preaparing the surface even and sand papered smooth as specified and directed by the department. C) Asian paint/Berger paint/ICI paint/J&N paint/Nerolac.
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per the specification of manufacture after throughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. Asian paint/Berger paint/ICI paint/J&N paint/Nerolac.
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine stees, wood scrapers and sand paper with ready mixed red-lead/red oxide primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter-Surface over 100mm in width or girth for General Purpose (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earthwork in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. 100mm thick slab
Grading roof water proofing treatment with cement concrete 1:2:4 1 cement: 2 coarse sand: 4 graded stone agg.20mm nominal size)
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete- with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) liters per square meter towards the concrete and masonary walls so as to ensure earth in contact with the structure well treated-with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the department complete-With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti-termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no.2611.3 above making a channel 30mm x 30mm all over the wall and making rod holes @ 150 mm apart up to ground level below and applying emulsion @11 litres per square meter of vertical plinth wall surface inside the building so as to soack the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceilling which includes G.I perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceilling, screw to brick wall/partition with the help of nylon sleeves and screws, at 610mm c/c Then suspending G.I intermediate channels of size 45mm (o.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceilling angle of width 25mm x 10mm x 0.55mm thick fixed to soffit with G.I. cleat and steel expansion fasteners. Celling scetion of 0.55mm thickness having knuried web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction to the intermediate channel at 457mm c/c 9.5mm/12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment, Finally, the boards are to be joined and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete aty all levels as specified and directed.
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extingisher confirming to IS:2171 with ISI mark and C02 cartridge will be confirming to IS:4947 with ISI mark, Powder will be confirming to IS:4308 with ISI Mark (Extinguisher will be TROLLEY MOUNTED) (50 KG) BRAND : FIRESTOP/FRIEND/FIRE SHIELD.
Providing fitting and fxing vitrems China Pedestel type water closet (European type W.C. Pan 400mm high) with seat and lead C.P brass hinges and rubber burffers CI/MS brakets, 40mm flush band with fittings including painting of fittings and brakets (Flushing Cistern to be paid separately) Parry ware make-White- Universal closet P trap Cat No.C0272
Providing fitting and fixing vitreous water closet squatting pan (indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls floors where ever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm White Parryware make
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. complete as directed and specified. Parrywaqre make Economy Single flush (CAT No.C8090/C8055)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required -Parryware make - White -Integrated EFS-Smart DC (Cat No.C8182)/Integrated EFS-Smart AC with power source (Cat No.C8195)
Supplying fiting and fixing vitreous china division plate including fitting and fixing complete as directed and specified - parryware make - White - Partion Magnum/ Large (Cat No.C0571/07)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) - PEDESTAL BASIN (WITH PEDESTAL)- Parryware Make cascade NXT 550 x 440 with short Pedestal and spring set (Cat No. C0404/C0379/c8298)
Providing fitting and fixing Decorative Mirror complete as directed and specified- Parryware make - Size 800mm x 600mm
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (A) Parryware Make Recess SP & SG dish (Cat.No. C9935)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified - Jaquar make - Continental towel ring square (Cat.No.ACN-1121)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified - Jaquar Make - 32mm (HT/FT) (Cat.No.ALD-705 / 709)
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified - Jaquar make - Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including joining, fitting and fixing wich clamps etc. as necessary complete at all levels including below G.L. as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 110mm dia.
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including joining, fitting and fixing wich clamps etc. as necessary complete at all levels including below G.L. as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 90mm dia.
Supplying fitting and fixing 87.5 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 90mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 110mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 90mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 90mm dia.
Supplying fitting and fixing PVC coupler of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 110mm dia.
Supplying fitting and fixing PVC reducer of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. i) 110mm dia.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. 90mm dia. PVC cowel of ISI make.
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. 110mm dia
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 38 kg weight complete as directed and specified.
Construction of filter bed soak pit including earth work in exacavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C.plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.)
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. Exposed on walls 50 mm dia (Medium) ii) Using other ISI marked approved brand
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquar Make-Continental-2 way bib cock.
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Jaquar- Continental 15mm dia Male / Female (long thread)
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Jaquar- Continental ii) 15mm dia (Angular Stop Cock)
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaguar make Continental
Suppyling and fitting gun metal country pit value (full way valve) ISI make as specified and directed. 40mm dia.
Supplying, fitting and fixing gum metal check value including necessary threads to pipes 40mm dia (Heavy type)
Any other unseen item of work which are not included in the estimate/BOQ may be required during executing of the works are as per APWD SOR for 2013-14 for Cuvil and Sanitary & Water Supply and Electrical works.
Wiring for light/fan/call bell point with 2 x 1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1 Short point up to 3.00 metre. length.
Wiring for light/fan/call bell point with 2 x 1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.2 Medium point up to 6.00 metre. length.
Wiring for light/fan/call bell point with 2 x 1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.3 Long point up to 10.00 metre. length.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Medium point up to 6.00 metre. Length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. Mm. + earth continuity with 1x2.5 sq mm cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copperconductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) including earth continuity in surface/recessed PVC 20mm. dia. 2mm thick/heavy ISI marked IS: 9537 PART-III rigid PVC conduit (Berlia/AKG/Precision/Presto Past/Polycab/MW or equivalent make as approved by the Deptt) wiring system.
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep. (ORIENT PSPO make)
Supplying fitting and fixing of ceiling fan regulator including connection etc. complete as required. Electronic type.
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department. Domestic Power Flow 225 mm sweep (ORIENT make)
18 Watt 4 ft LED Batten (Bright line PHILLIPS make)
Supplying fixing of batten holder (Anchor Penta PC CHERRY/Gold medal/ Kolor kany.kom/ Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt. as required (without Lamp)
Philips LED bulbs non-dimmable 7/9 W or equivalent as approved by the Deptt.
Philips lighting luminaire 29w Endura LED Well Glass Model BY200P LED 27S CW PSU S1 PC or equivalent as appoved by the Deptt.
Supply installation & testing of G.I earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40mm G.I reducing socket for funnel including locking arramgement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 6 SWG G.I. Earth from Earth Electrode (below G.L) to electrical switch gears or electrical machineries including making necessary connection as approved specified and directed by the deptt.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 8 way SPN Double Door
Supplying with fitting fixing single pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.6 to 32A
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. B. Series (Schneider MG, Legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB,Schneider MG, legrand, Hager make) 40A
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivalent) 2 Core A2XWaY A2XFaY 4.00 Sqmm 2 Core armoured U.G cable
Supply and laying of following size Power/Control Copper cables Solid copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm. 8 x 2.5 sq mm. 2 x 10 sq mm. 3 x 10 sq mm. 4 x 6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivale+B5342nt) 2 Core A2XWaY A2XFaY 6.00 Sqmm 3 Core armoured U.G cable
1 HP single Phase Centrifugal monoblock pump set (Crompton Greaves/Aquatic/CRI/V-Guard make) with DOL Starter (Crompton Greaves/Control & Switch Gear/ BCH/L&T/Siemens make).
ASEB Load nd Meter security
Service connection
(E) Construction of Barrack Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completon of work. breaking clods in return filling dressing. watering and ramming etc and removal of surplus earth with all lead & lift as directed and specified in the following classification of soils including bailing out water where necessary as directed and spedified up to a depth of 2.0 m below the existing G.L.-In Ordinary Soil.
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees if any monopoly duty etc. (profile meassurement to be taken and 12.5% deduction for shrinkage to be made from total quantuty) etc. complete as per directed and specified including forest royalty within a distance of 8.00 km (Forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by DFO concerned) Other than Guwahati city.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In prop 1:3:6 (1 cement: 3 coarse sand : 6 coarse aggregate by volume (Using mixture machine)
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg.of size 13mm to 32mm including dewatering if necessary, and curing etc complete. 50mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1:5:3 with graded stone agg. of 10mm down nominal size including including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
Plain cement concrete aprone in prop 1:4:8 with 20mm down graded coarse agg. Over soiling including neat cement finish using cement slurry 2.75kg of cement per sq.m. of floor (soilng to be measured separately) 50mm thick.
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) Using Mixture machine In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. Without using admixture, plasticiser
In Super Structure from plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. Without using admixture, plasticiser M20 grade concrete or prop 1:1.5:3
Extra for using plasticiser in concrete if admixture, plasticiser etc.are not included in the item rate. M20 grade concrete or Prop.1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.-Using 38mm thick plank
Sides of tie beams, grade beams etc. at or below ground level. Using 38mm thick plank
Providing form work of 12mm thick plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face In Ground Floor. Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties for depth not exceeding 1.0M. In Ground Floor
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like for Floors etc. upto 200mm in thickness.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). TMT Corrosion Resistant Steel (Fe-500) reinforcement bar (TATA/SAIL) in foundation & plinth For Ground Floor
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. Using TATA make RHS/SHS of grade 310 conforming to relevent ISI marked approved brand tube.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. Brick on flat soiling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (c) In prop 1:5
(I) In Super-Structure above plinth up to 1st floor level. (b) In proportion 1:4 (1 cement: 4 sand)
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) 112mm thick brick wall In cement mortar in proporation 1:4 (1 cement: 4 sand)
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. On fair side in cement mortar 1:4 for internal wall plastering. In Ground Floor
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. On rough In cement mortar 1:4
Extra over item no 31 & 32 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement slurry mixed withapproved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the department) (Walls means both interior and exterior walls). Delux range-Somany/Orient/Nitco/Varmora Make Of size 300mm x 600mm and above
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. CERAMIC Normal range (Sizes 300 mm x 300mm and above) Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
Providing Pre Painted Galvanized iron sheet (PPGI) at all levels including fitting and fixing with self drilling self tapping screws complete. (Roof truss, purlins etc. to be measured and paid separately.) TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department. (ii) 0.45 mm thick
Providing Pre Painted Galvanized iron sheet (PPGI) accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing self drilling self tapping screws complete. TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department. (ii) 0.45 mm thick
Providing fiting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed togheter by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be up with 1:4:4 PCC after fitting the frame with brick/concrete works etc. complete as directed by the department for all levels. (PCC to be measured and paid for seperately) 1.60mm thick sheet
Providing fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5 to 3.5mm uniformaly thick cross bands style & rails made from hardwood timber of width not less than 50mm fixed to the door frames (chowkath) with necessary hings, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) 40mm thick.
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). Tower bolts. 300mm x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). Tower bolts. 250mm x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). Door handles. 100mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). Door handles. 150mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). Morttice lock vertical type 100mm (Godrej with handle (6 lever)
Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright nature matt & satin finished). Door stopper with rubber stopper.
FRP FRAME providing & fixing of factory made Fibreglass Reinforced Plastic (FRP) door frame of FIBREWAYS three legged of cross section 90mmx 45mm having single rebet of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame moulded with fire retardant grade unsarurated polyster resin and chopped mat. door frame laminate and shall be filled with suitable wooden block in all the three legs the frame shall be covered with covered glass from all sides. MS stay shall be provided........
FRP FLUSH DOOR supplying & fixing of factory made 30mm thick Fibreglass Reinforced Plastic (FRP) panneled door shutter of required colour of FIBREWAYS made with fire retardant grade unsatured polyster resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels and conforming to to IS:14856-2000 including fixing to frames.
Providing fitting and fixing M.S grill of required pattern for windows/ clerestory windows/opening with M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. Omamental Grill Fixed to Brickwork/P.C.C/R.C.C
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved band (Hindalco/Nalco/Jindal/Balco or equivalent primary producer) without horizontal glazing bars joints mitred and welded relevent to standard IS specifications fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, angles cleat rubber gasket, bolting device, locking asrrangements, screws etc. as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). 6mm frosted glass
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved band (Hindalco/Nalco/Jindal/Balco or equivalent primary producer) without horizontal glazing bars joints mitred and welded relevent to standard IS specifications fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, angles cleat rubber gasket, bolting device, locking asrrangements, screws etc. as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). (A) Side hung and Top hung windows and ventilators 5mm frosted glass
DISTEMPERING Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from morter droppimgs and other foreign matter and including preparing surface even and sand papered somooth. Priming coat with distemper primer.
DISTEMPERING Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from morter droppimgs and other foreign matter and including preparing surface even and sand papered somooth. Top Coat
Applying one self- priming coat of acrylic emulsion paint of approved brand, thinning by adding water as per the specification of manufacturer over freshly plastered wall surface after throughly brooming the surfaces free mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. Asian paint/Berger paint/ICI paint/J&N paint/Nerolac
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per specification of manufacturer after throughly brooming the surfaces to removed all dirt and remains of loose powdered materials as specified and directed by the department. Asian paint/Berger paint/ICI paint/J&N paint/Nerolac
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine stees, wood scrapers and sand paper. With ready mixed red-lead/red oxide primer
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. Surface over 100mm in width or girth for General purpose (Asian paint/Berger paint/ ICI paint/J & N paint/Nerolac).
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earthwork in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering, curing etc. complete including fixing in position as directed. 100mm thick slab
Grading roof for water proofing treatment with cement concrete 1:2:4 1 cement: 2 coarse sand: 4 graded stone agg.20mm nominal size)
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) liters per square meter towards the concrete and masonary walls so as to ensure earth in contact with the structure well treated-with. with chemical (Supplying with necessary tools and accessories by the contractor) as per the direction of the Department complete- with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti-termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no.2611.3 above making a channel 30mm x 30mm all over the wall and making rod holes @ 150 mm apart up to ground level below and applying emulsion @11 litres per square meter of vertical plinth wall surface inside the building so as to soack the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the department complete. With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceilling which includes G.I perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceilling, screw to brick wall/partition with the help of nylon sleeves and screws, at 610mm c/c Then suspending G.I intermediate channels of size 45mm (o.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceilling angle of width 25mm x 10mm x 0.55mm thick fixed to soffit with G.I. cleat and steel expansion fasteners. Celling scetion of 0.55mm thickness having knuried web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction to the intermediate channel at 457mm c/c 9.5mm/12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment, Finally, the boards are to be joined and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete aty all levels as specified and directed.
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (Extinguisher will be TROLLEY MOUNTED) (50 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high) with seat and lead, CP brass hinges and rubber buffers , CI/MS brackets, 40 mm dia flush band with fittings including painting of fittings and brackets (Flushing Cistern to be paid separately) Parryware make - White - Universal Closet P Trap Cat No.C0272)
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make/a) White/(i)Economy Single Flush (Cat No.C8090/C8055)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)- PEDESTAL BASIN (with pedestal) -Parryware Make Cascade NXT 550 x 440 with short Pedestal and spring set (Cat. No.C0404/C0379/C8298)
Providing fitting and fixing Decorative Mirror complete as directed and specified - Parryware make - Size 800mm x 600mm
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (A) Parryware Make Recess SP & SG dish (Cat.No. C9935)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified - Jaquar Make - Continental towel ring square (Cat.No.ACN-1121)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified - Jaquar Make - 32mm (HT/FT) (Cat.No.ALD-705 / 709)
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified - Jaquar make - Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 90mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 90mm dia.
Supplying, fitting and fixing PVC plain single tee of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110mm dia.
Supplying, fitting and fixing PVC plain single tee of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 90mm dia.
Supplying, fitting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110mm dia.
Supplying, fitting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 90mm dia.
Supplying, fitting and fixing PVC coupler of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 110 mm dia
Supplying, fitting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110 mm x 90 mm
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. 90mm dia. PVC cowel of ISI make.
Providing fitting and fixing C.I. Grating to the floors complete as directed and specified. 110mm dia
Providing fitting and fixing 450mm dia 90mm thick C.I. Man hole cover and frame of 38 Kg. Weight complete as directed and specified.
Construction of filter bed soak pit including earth work in exacavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C.plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. Exposed on walls 50 mm dia (Medium) Using Tata make
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) - Jaquare make - Continental -2- Way bib cock
Supplying fitting and fixing Chrome Plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified (G.I & C.P pipes will be measured and paid separately) - Jaquare make - Continental 15mm dia. Male/Female (long thread)
Supplying fitting and fixing Chrome Plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified (G.I & C.P pipes will be measured and paid separately) - Jaquare make - Continental 15mm dia (Angular stop cock)
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaguar make Continental
Suppyling fitting and fixing gun metal country pit value (full way valve) ISI make as specified and directed. 40mm dia.
Suppyling fitting and fixing gun metal check value including necessary threads to pipes - 40 mm dia (Heavy type)
Any other unseen item of work which are not included in the estimate/BOQ may be required during executing of the works are as per APWD SOR for 2013-14 for Civil and Sanitary & Water Supply and Electrical works.
Wiring in light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Short point up to 3.00 metre. length.
Wiring in light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Medium point up to 6.00 metre. length.
Wiring in light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Long point up to 10.00 metre. length.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Medium point up to 6.00 metre. Length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS:9537 Part - III conduit
With 2 x 4 sq. Mm. + earth continuity with 1x2.5 sq mm cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kbel or Equivalent Make as approved by the Deptt.) including earth continuity in surface/recessed PVC 20mm. dia. 2mm thick/heavy ISI marked IS: 9537 PART-III rigid PVC conduit (Berlia/AKG/Precision/Presto Past/Polycab/MW or equivalent make as approved by the Deptt) wiring system.
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep. (ORIENT PSPO make)
Supplying fitting and fixing of ceiling fan regulator including connection etc. complete as required. Electronic type.
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department. Domestic Power Flow 225 mm sweep (ORIENT make)
18 Watt 4 ft LED Batten (Bright line PHILLIPS make)
Supplying and fiixing of batten holder (Anchor Penta PC CHERRY/Gold Medal/Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.) as required (With out Lamp.)
Philips LED bulbs non-dimmable 7/9 W or equivalent as approved by the Deptt.
Philips lighting luminaire 29w Endura LED Well Glass Model BY200P LED 27S CW PSU S1 PC or equivalent as appoved by the Deptt.
Supply installation & testing of G.I earth station with perforated 40 mm dia and 4.50 mt. long heady duty G.I pipe with necessary 40 mm dia. G.I. Fitting such as Socket for tee, elbow, nipple, and 50mm x 40mm G.I reducing socket for funnel including locking arramgement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner of outer surface of wall as specified and directed by the deptt.
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 6 SWG G.I Earth from Earth Electrode (below G.L) to electrical switch gears or electrical machineries including making necessary connection as approved specified and directed by the deptt.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 8 way SPN Double Door
Supplying with fitting fixing pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved by the deptt. 6 to 32A
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. B-Series (Schneider MG, legrand, Hager, Crabtree expro make) 40A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity 4P RCCB (A+B370B+B1549B, Schneider MG, legrand, Hager make) 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager make)
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivalent) 2 Core A2XWAY A2XFay 4.00 Sq.,, 2 Core armoured U.G. cable.
Supply and laying of following size Power/Control Copper cables Solid copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm. 8 x 2.5 sq mm. 2 x 10 sq mm. 3 x 10 sq mm. 4 x 6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make) 6.00 Sq.mm 3 Core armoured U.G cable
1 HP single Phase Centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) with DOL Starter (Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
ASEB Load nd Meter security
Service Connection
(F) Construction of Chowkider Qtr: Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified Up to a depth of 2.00m below the existing ground level-In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees if any monopoly duty etc. (profile meassurement to be taken and 12.5% deduction for shrinkage to be made from total quantuty) etc. complete as per directed and specified, including forest royalty within a distance of 8.00 km. (forest royalty shall be reimbursed on production of necessary certificate from the forest authority duly countersigned by D.F.O. concerned. Other than Guwahati city
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.)-In prop 1:3:6 (1 cement :3 coarse sand : 6 coarse aggregate by volume. (using mixture machine).
Plan cement cioncrete floor base in prop l:3:6 laid in alternate bays as specified with coasre agg. of size 13 mm to 32 mm including dewatering if necessary and canting etc complete. 50mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded store agg. of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
Plain cement concrete aprone in prop 1:4:8 with 20mm down graded coarse agg. Over soiling including neat cement finish ising slurry 2.75kg/m2 of cement per sq.mm of floor (soling to be measured separately) 50mm thick.
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Using Mixture Matchine In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. M-20 grade concrete or Prop. 1:1.5:3
Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) Using Mixture Matchine In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill, band, beam, girder, bressumer, cantilever, staircase (except spiral stair case and landing) including preparing the top surface & finishing of nosing. Without using admixture, plasticiser M-20 grade concrete or Prop. 1:1.5:3
Extra for using plasticiser in concrete if admixture, plasticiser etc.are not included in the item rate. M20 grade concrete or Prop.1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 38mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level- Using 38mm thick plank
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. Column, pillars, post & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc. having plan vertical face. In Ground Floor
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. Side and soffts of beams, beam haunchings, cantilever girder, bressumers, lintel & horizontal ties for depth not exceeding 1.0M In Ground Floor
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like for floors etc. upto 200mm in thickness. In Ground Floor
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level)-TMT Corrosion Resistant Steel (Fe-500) reinforcement bar (TATA/SAIL) In Foundation & Plinth For Ground Floor
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. USing TATA make RHS/SHS of Grade 310 conforming to relevent IS: code 4923:1997
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete-Brick flat soling.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed in sub-structure of the plinth level. (c) In proporation 1:5
(I) In Super-Structure above plinth level up to 1st floor level. B) In proporation 1:4 (1 cement: 4 sand)
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) 112mm thick brick wall In cement mortar in proportion 1:4. (1 cement:4 sand)
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed-On fair side in cement mortar 1:4 for internal wall plastering in ground floor.
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed-On fair side in cement mortar 1:4 for internal wall plastering in ground floor. On Rough Side In Cement Mortar 1:4
Extra over item no. 31 & 32 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) white cement slurry mixed withapproved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the department) (Walls means both interior and exterior walls). Delux range-Somany/Orient/Nitco/Varmora Make-Of size 300mm x 600mm and above
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. CERAMIC Normal range (Sizes 300 mm x 300mm and above) Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate.
Providing Pre Painted Galvanized iron sheet (PPGI) at all levels including fitting and fixing with self drilling self tapping screws complete.(Roof truss, purlins etc. to be measured and paid separately.) TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department. (ii) 0.45 mm thick
Providing Pre Painted Galvanized iron sheet (PPGI) accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing, self drilling, self tapping screws complete. TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department. 0.45 mm thick
Providing fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the botton of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete work etc. complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). 1.60mm thick sheet Size 125mm x 60mm (Single rebate)
Providing fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber , 25mm core battens 2.5mm to 3.5mm uniformaly thick cross bands style & rails made from hardwood timber of width not less than 50mm fixed to the door frames (chowkath) with necessary hings, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately) (ii) 40 mm thick
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Tower bolts 300 x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Tower bolts 250x 12mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Door Handles 100mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) C. Door handles iiz) 150mm
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Mortice lock vertical type 100mm (Godrej) with handle (6 lever)
Supplying, fitting and fixing anodised aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & satin finished). Door stopper with rubber stopper
FRP FRAME providing & fixing of factory made Fibreglass Reinforced Plastic (FRP) door frame of FIBREWAYS three legged of cross section 90mmx 45mm having single rebet of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame moulded with fire retaedant grade unsaturated polyster resin and chopped mat. Door frame laminate and shall be filled with suitable wooden block in all the three legs the frame shall be covered with covered glass from all sides. MS stay shall be provided at the bottom to steady the frame.
FRP FLUSH DOOR Supplying & fixing of factory made 30mm thick Fibreglass Reinforced Plastic (FRP) panneled door shutter of required colour of FIBREWAYS made with fire retardant grade unsatured polyster resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fitting, cast monolithically with 5mm thick FRP laminate for panels and conforming to IS:14856-2000 including fixing to frames complete as per direction of Engineer-in charge.
Providing fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. Omamental Grill- Fixed to Brickwork/P.C.C/R.C.C
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved band (Hindalco/Nalco/Jindal/Balco or equivalent primaey producer) without horizontal glazing bars joints mitred and welded relevent to standard is specifications fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, angle cleat rubber gasket, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). 6mm clear glass
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved band (Hindalco/Nalco/Jindal/Balco or equivalent primaey producer) without horizontal glazing bars joints mitred and welded relevent to standard is specifications fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, angle cleat rubber gasket, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). 6mm clear glass Side hung and Top hung windows and ventilators 5mm frosted glass
DISTEMPERING Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including, a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from mortar droppimgs and other foreign matter and including preparing surface even and sand papered somooth. Priming coat with distemper primer
DISTEMPERING Distempering two coats with oil bond distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including, a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from mortar droppimgs and other foreign matter and including preparing surface even and sand papered somooth. Top Coat
Applying one self-priming coat of acrylic emulsion paint of approved brand, thinning by adding water as per the specification of manufacture over freshly plastered wall surface after throughly brooming the surfaces free from mortar droopings and other foreign matter and including preaparing the surface even and sand papered smooth as specified and directed by the department. C) Asian paint/Berger paint/ICI paint/J&N paint/Nerolac.
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thinning by adding water as per the specification of manufacture after throughly brooming the surface to remove all dirt and remains of loose powdered materials as specified and directed by the department. Asian paint/Berger paint/ICI paint/J&N paint/Nerolac.
Applying primary coat over new steel and other metal surface up to 100mm in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter-Surface over 100mm in width or girth for General Purpose (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earthwork in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. 100mm thick slab
Grading roof water proofing treatment with cement concrete 1:2:4 1 cement: 2 coarse sand: 4 graded stone agg.20mm nominal size)
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete- with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) liters per square meter towards the concrete and masonary walls so as to ensure earth in contact with the structure well treated-with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the department complete-With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti-termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no.2611.3 above making a channel 30mm x 30mm all over the wall and making rod holes @ 150 mm apart up to ground level below and applying emulsion @11 litres per square meter of vertical plinth wall surface inside the building so as to soack the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceilling which includes G.I perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceilling, screw to brick wall/partition with the help of nylon sleeves and screws, at 610mm c/c Then suspending G.I intermediate channels of size 45mm (o.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceilling angle of width 25mm x 10mm x 0.55mm thick fixed to soffit with G.I. cleat and steel expansion fasteners. Celling scetion of 0.55mm thickness having knuried web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction to the intermediate channel at 457mm c/c 9.5mm/12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment, Finally, the boards are to be joined and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete aty all levels as specified and directed.
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extingisher confirming to IS:2171 with ISI mark and C02 cartridge will be confirming to IS:4947 with ISI mark, Powder will be confirming to IS:4308 with ISI Mark (Extinguisher will be TROLLEY MOUNTED) (50 KG) BRAND : FIRESTOP/FRIEND/FIRE SHIELD.
Providing fitting and fxing vitrems China Pedestel type water closet (European type W.C. Pan 400mm high) with seat and lead C.P brass hinges and rubber burffers CI/MS brakets, 40mm flush band with fittings including painting of fittings and brakets (Flushing Cistern to be paid separately) Parry ware make-White- Universal closet P trap Cat No.C0272
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. complete as directed and specified. Parrywaqre make Economy Single flush (CAT No.C8090/C8055)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) - PEDESTAL BASIN (WITH PEDESTAL)- Parryware Make cascade NXT 550 x 440 with short Pedestal and spring set (Cat No. C0404/C0379/c8298)
Providing fitting and fixing Decorative Mirror complete as directed and specified- Parryware make - Size 800mm x 600mm
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (A) Parryware Make Recess SP & SG dish (Cat.No. C9935)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified - Jaquar make - Continental towel ring square (Cat.No.ACN-1121)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified - Jaquar Make - 32mm (HT/FT) (Cat.No.ALD-705 / 709)
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified - Jaquar make - Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including joining, fitting and fixing wich clamps etc. as necessary complete at all levels including below G.L. as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 110mm dia.
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including joining, fitting and fixing wich clamps etc. as necessary complete at all levels including below G.L. as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 90mm dia.
Supplying fitting and fixing 87.5 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 90mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 110mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 90mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified - Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. 90mm dia.
Supplying fitting and fixing PVC coupler of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. In exposed surfaces or in trenches. 110mm dia.
Supplying fitting and fixing PVC reducer of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. i) 110mm dia.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. 90mm dia. PVC cowel of ISI make.
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. 110mm dia
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 38 kg weight complete as directed and specified.
Construction of filter bed soak pit including earth work in exacavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C.plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.)
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. Exposed on walls 50 mm dia (Medium) ii) Using other ISI marked approved brand
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquar Make-Continental-2 way bib cock.
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Jaquar- Continental 15mm dia Male / Female (long thread)
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Jaquar- Continental ii) 15mm dia (Angular Stop Cock)
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaguar make Continental
Suppyling and fitting gun metal country pit value (full way valve) ISI make as specified and directed. 40mm dia.
Supplying, fitting and fixing gum metal check value including necessary threads to pipes 40mm dia (Heavy type)
Any other unseen item of work which are not included in the estimate/BOQ may be required during executing of the works are as per APWD SOR for 2013-14 for Cuvil and Sanitary & Water Supply and Electrical works.
Wiring for light/fan/call bell point with 2 x 1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1 Short point up to 3.00 metre. length.
Wiring for light/fan/call bell point with 2 x 1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.2 Medium point up to 6.00 metre. length.
Wiring for light/fan/call bell point with 2 x 1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.3 Long point up to 10.00 metre. length.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS:9537 Part - III conduit
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 4 sq. Mm. + earth continuity with 1x2.5 sq mm cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copperconductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) including earth continuity in surface/recessed PVC 20mm. dia. 2mm thick/heavy ISI marked IS: 9537 PART-III rigid PVC conduit (Berlia/AKG/Precision/Presto Past/Polycab/MW or equivalent make as approved by the Deptt) wiring system.
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep. (ORIENT PSPO make)
Supplying fitting and fixing of ceiling fan regulator including connection etc. complete as required. Electronic type.
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department. Domestic Power Flow 225 mm sweep (ORIENT make)
Supplying and fixing of call bell (buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the deptt.) as required.
18 Watt 4 ft LED Batten (Bright line PHILLIPS make)
Supplying fixing of batten holder (Anchor Penta PC CHERRY/Gold medal/ Kolor kany.kom/ Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt. as required (without Lamp)
Philips LED bulbs non-dimmable 7/9 W or equivalent as approved by the Deptt.
Philips lighting luminaire 29w Endura LED Well Glass Model BY200P LED 27S CW PSU S1 PC or equivalent as appoved by the Deptt.
Supply installation & testing of G.I earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40mm G.I reducing socket for funnel including locking arramgement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 6 SWG G.I. Earth from Earth Electrode (below G.L) to electrical switch gears or electrical machineries including making necessary connection as approved specified and directed by the deptt.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 8 way SPN Double Door
Supplying with fitting fixing single pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.6 to 32A
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. B. Series (Schneider MG, Legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB,Schneider MG, legrand, Hager make) 40A
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivalent) 2 Core A2XWaY A2XFaY 4.00 Sqmm 2 Core armoured U.G cable
Supply and laying of following size Power/Control Copper cables Solid copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm. 8 x 2.5 sq mm. 2 x 10 sq mm. 3 x 10 sq mm. 4 x 6 sq mm balance all galvanised steel strip), extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivale+B5342nt) 2 Core A2XWaY A2XFaY 6.00 Sqmm 3 Core armoured U.G cable
1.5 HP single phase open well submersible monoblock water cooled pump set (Crompton Greaves/Aquatic/CRI/V-Guaed make) 220v, 50hz, 2900 rpm with control panel.
ASEB Load nd Meter security
Service connection
(G) Construction of Approach Road for Canteen, Barrack and Qtr: Surface dressing of ground including removing vegetation and/or undulation of ground not exceeding 150mm deep and disposal of ruddish outside the periphery and lift up to 1800mm in all kinds of soil.
Construction of gramlar sub base by providing closed graded materials..............specification.
Providing laying spreading and compacting WBM grading (III) grading II materials (53-22.4mm size) .................specification including 405. (A) By Manual Means.
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/running/herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted....of MORD
(H) Construction of ICBP Approach road from Main Road to Planetarium Gate: Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits, with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 (including compensation of earth) (Including cost of testing of materials at site and laboratiry as directed by the deptt.) (i) From Private land
Surface dressing of ground including removing vegetation and/or undulation of ground not exceeding 150mm deep and disposal of ruddish outside the periphery and lift up to 1800mm in all kinds of soil.
Construction of gramlar sub base by providing closed graded rate..............specified
Providing laying spreading and compacting WBM grading (III) grading II materials (53-22.4mm size) .................specification including 405. (A) By Manual Means.
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over....................of MORD
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, step, walls, etc. as directed and specified...............complete. (a) In prop 1:3:6
Providing form work of ordinary timber planking so as to give a rough finish including centering,shuttering, strutting and proping etc. and remove of the same for in situ...............road. (b) Using 25mm thick.
RCC guard post supplying fitting and fixing RCC guard post 15 cm long 75 cm above the ground level.
(I) Providing C.C. T.V: Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.3.1 Short long point up to 3.00 metre. length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.3.2 Short Medium up to 6.00 metre. length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) 2.3.3 Short long up to 10.00 metre. length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. 2.6.1 With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. 2.7 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq.mm in 20mm dia 2mm thick/heavy rigid PVC IS:9537 Part III conduit
Supplying installation testing and commissioning of 1/3 Super HAD Colour CCD 600 TV LINES, 0.15 LUX, 8mm Fixed Lens, Compact, light weight, DC12V (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation and testing and commissioning of high resoluation Vandal-Resistant Dome Camera 1/3 CCD, Built-in 3.6 x (2.8-10mm) varifocal lens with auto iris Day & Night with ICR (infrared Cut filler removal) High resoluation of 600TV lines (Colour), Protection against water & dust (IP66) (SAMSUNG or equivalent HONEWELL/PANASONIC make).
Supplying installation testing and commissioning of 8ch CIF real-time DVR, Video (H-264)/Audio (ADPCM), CIF resoluation real-time-recording capability (Full 4 CIF resolution recording support) Up to 4ch audio inputs and 1ch audio output, Combined BNC and VGA video cutput for main display (upto 1280 x 1024), SATAI/F HDD support (internal max. HDD x 1) DVD R/W, Built-in web viewer-small IR Dome Camera, 600 TVL (Colour) /700 TVL (B/W), IR Distance 7m, DDNS (SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation testing and commissioning of 8ch CIF real-time DVR, Video (H-264), 200 (PAL) fps recording rate Up to 8ch audio inputs and 1ch audio output, Max 5 internal HDD (HDDx 5), DVD-RW, Built-in web viewer-(SAMSUNG or equivalent HONEYWELL/PANASONIC make)
Supplying installation of BNC connection per pair iix make
Supplying installation testing of UTP CAT6 Cable without PVC conduit.
(J) Renovation of Conference Hall: (i) Interior Design of the Conference Hall of Kokrajhar Planetarium and Science Centre at Kokrajhar, BTC, ASSAM. (Provision of Acoustic panelling, carpeting of floor, Supply of Executive Chairs. Etc)............. Supplying, fitting Sound Soak NSS Cord (FSS Cord) wrapped acoustical wall panel system of Anutone Acoustics Ltd. Including all fixtures and fittings. b) 25mm thick. Conference Hall
Providing dressed wood work in post, wall, batters, post plate bressumer etc. including supplying and fusing with spikes, nail, bolt and nuts of 12mm dia. (M.S) and required lenght etc. Complete with Kiricide oiling the Coats to faces in contact C.C or masonry...................... and paid Separately. a) With sal wood
Wooden planking in floor including fixing to wooden frame with iron screws complete (base of the wood frame to be measured and paid separately.)
Varnishing two coat (excluding priming coat) onnew wood and wood based surfaces under coating with flatting varnish and finishing coat with copal varnish or spar varnish to give an even surface including cleaning the surface of all dirt, dust and filling the knots, crack...............................matt surface. (i) Surface over 100mm in width or girth.
Providing Arm chair with cushin seated with good quality for conference Hall.
Providing wooden carpet for conference Hall including fitting fixing and placing in position etc. Complete.
(ii) Cost for providing A.C. Machine......... Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision presto plast/polycab/MW or equivalent make as approved by the Deptt.) in surface system including providing and fixing 5/6 pin 16 Amps flush type socket outlet and 16 Amps flush type switch (Anchor penta/Gold medel/kolor kany./kom/Havells or equivalent make as approved by the Deptt.) GI/MS switch board (ISI marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. Long point up to 10.00 metre. length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel/ or Equivalent Makes as approved by the Deptt.) in surface ISI marked casing and capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.3 With 2 x 6 sq. mm. + earth continuity with 1 x 4 sq. mm. in flat 25 mm. ISI marked casing and capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface flat ISI market casing 'n' capping (AKG/Precision/presto plast/polycab/MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.10.4 With 2 x 10 sq. mm. + earth continuity with 2 x 6 sq. mm. cable in flat 32mm ISI market casing 'n; capping system.
Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 14.1.1 20A Capacity. (C&S, Havells, Standard or equivalent make as approved by the deptt)
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 (ABB, Scheider MG, lengrand, Hager, Crabtree xpro make) 15.2.1.2 6 way SPN double door.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc. fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1 (ABB, Scheider MG, lengrand, Hager, Crabtree xpro make) 15.8.1.1 4 way TPN (4+12) double door.
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved by the deptt. 16.3.1 B-Series (ABB, Schneider MG, LEGRAND, HEGER, CRABTREE, XPRO MAKE) 16.3.1.2 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved by the deptt. 16.6.1 B-Series (Schneider MG, LEGRAND, HEGER, CRABTREE, XPRO MAKE) 16.6.1.3 63A
Supplying with fitting fixing 30/100/300 Ma sensitivity 240/415V 50Hz DP RCCB of the following capacity complete making necessary connection as approved and specified by the deptt. 16.7.1 30 Ma sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make.) 16.7.1.1 25A
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40mm dia. G.I. fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
Extra for using salt 5 K and Charcoal 96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying with installation testing and commissioning of Hi- wall 4 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection cable, as approved by the Deptt. up to 5m between the room unit and out door unit as directed by the department. 29.1.2 1.5 Ton capacity 29.1.2.2 Carrier make Dura cool star premium.
Supplying with fitting and fixing single phase D.O.L starter of the following specification complete including making necessary connection as approved, specified and directed by the deptt. 30.11.1 Overload Relay Range 3.8-6.0 Amps for 2.2 KW
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) 31.1.8 5.0 KVA Automatic Input 90-280 V Out put 200-240 V
Supplying with fitting and fixing of Angle iron framing made 50mm x 50mm x 5mm size angle iron for accommodation of 1.00 Ton to 2.00 Ton window/split type A.A. Machine.
(iii) Cost for Provision of Audio System and Projector: Supplying installation testing programming and commissioning of Audio equipment 8 Channels power Amplifier 125 Wper channel @ 8 ohms.
Supplying installation testing programming and commissioning of Audio equipment, single auto former to provide impedance matching between an amplifier output and constant voltage loud speakers.
Supplying installation testing programming and commissioning of Audio equipment, Dual Channel power Amplifier, 550w @20hm 350@40ohm 215w @ 8 ohm per channel.
Supplying installation testing programming and commissioning of Audio equipment, Goseneck or equipment as approved by the Depts. Microphone-30/50 cm hypercardiod gooseneck (or equivalent as approved by the Deptt.) Microphone without base.
Supplying installation testing programming and commissioning of Audio equipment, balanced Microphone cable with single shild, high flexible velvet paint PVC-Jacket (0.22mm2) Jacket, PVC, 6.0mm max
Supplying installation of Audio equipment, SPEAKER STANDS, HOLDS up to 50 kg, wt.2.45 kg, H:1270/1930m
Supplying installation of Audio equipment, DESKTOP STANDS, compact, zinc die-cost base 3-pin XLR connection (or equipment as approved by the Deptt.) male/female, completely mounted, crackle-free switching, with phantom powering-pilot light with switch (Gray), Two diodes indicate the operating state (voltage / microphone on/off)
Supplying installation of Microphone floor stand, H:890-1600mm, BL:680MM, Weight: 1.85 Kg.
Supplying installation testing, programming & commission of video equipment Remote control motorized projector ceilling lift with low voltage relay for controlling by third party controller like Cresto/AMX or equivalent as approved by the deptt.
Supplying installation testing, programming & commission of Audio and video equipment Motorized screen with RF remote control, size-6Ft/4Ft,4:3Aspect Ratio.
(K) Providing Aluminium Ladder (1 No): Providing Aluminium Ladder
Manas Das
Sajal Sengupta
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .