Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹8.6 L+₹55,338.95 (6.91%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹8.8 L+₹80,865 (10.1%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹9.2 L+₹1.1 L (14.2%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
9 Jul 2019, 6:00 pmClosed
GE 969 EWS C/O 56 APO
GE 969 EWS C/O 56 APO
REPAIR/ MAINT OF INTERNAL WIRING INCLUDING FIXTURES AND FITTINGS AT HAWS TRG EST AND GULMARG UNDER GE 969 EWS.
2019_MES_259694_1
969/WS- /2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GULMARG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 969 EWS C/O 56 APO
₹20,000
Yes
9 Mar 2020
13 Jun 2019
12 Jul 2019
13 Jun 2019
9 Jul 2019
27 Jun 2019
Amount
Taking down carefully any type point wiring (light, fan, socket or power) complete including conduits/casing- capping with fittings such as light fittings, sockets, switches ceiling roses, board outlets etc and removing the materials/ debris and making good disturbed surfaces of walls, floor etc to match with the existing surface.Complete all as specified and directed by Engr-in-Charge.
M&L for point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 25 mm medium grade ISI marked PVC casing caping with all accessories such as bends, elbow, reducers , junction boxes /MS boxes duly painted /PVC box factory made ractangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixed with screws, for housing switches, sockets, regulators etc, including 1.5 sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly Complete all as specified and directed by Engr-in-Charge, for the following :- (a) One light/ceiling fan point controlled by one switch. Make: Polycab/ Finolex/ Universal/KEI.
(b) All as per item no.02 above but one switch socket combination 5 Amps on independent board.
(c) All as per item no.02 above but One switch socket outlet 5 Amps on same board with other switches.
M&L for point wiring in non-metallic PVC casing & caping including all fitting with 2.5 Sq mm size multi stranded FRLS copper conductor cable including clamps, screws gutti /plug etc PVC unsheathed cable into and including wooden board/sheet steel box of 1.6mm thick with bakelite sheet 3mm thick and PVC insulated fire retardant cable of size 2.5 Sq mm as earth continuity conductor. Complete all as specified and directed by Engr-in-Charge,Make: Polycab/ Finolex/ Universal/KEI.
S & F switch piano flush type single pole, one way 5/6 Amp.Complete all as specified and directed by Engr-in-Charge,
S&F switch socket combination flush type multipurpose 2/3 pin suitable for 5 Amp plug top controlled by one switch. Complete all as specified and directed by Engr-in-Charge. .Make:- Legrand/ Siemens/ Schneider / L&T.
S & F switch socket outlet two in 1, 3 Pin, 5 Amp, 230 Volts Complete all as specified and directed by Engr-in-Charge. .Make:- Legrand/ Siemens/ Schneider / L&T.
S&F switch socket combination flush type multipurpose 3/5 pin suitable for 15 Amp Complete all as specified and directed by Engr-in-Charge, .Make:- Legrand/ Siemens/ Schneider / L&T.
S&F ceiling rose surface bakelite surface 65x50 mm, 3 trminals fixed on wall/ceiling and including PVC block.Complete all as specified and directed by Engr-in-Charge,
S&F in repairs1 X 18 W LUMILINE Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver. Make :Make:Syska /GE /Philips /Crompton
S&F in repair Lamp holder/angle batten, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings.Complete all as specified and directed by Engr-in-Charge.
S&F in repair LED lamp of 7 watts 230 volts type. Complete all as specified and directed by Engr-in-Charge. Make:Syska /GE /Philips /Crompton
Supply & Fixing in repair switch piano 5 Amp flush type Complete all as specified and directed by Engr-in-Charge,Make:- Legrand/ Siemens/ Schneider / L&T.
S&F in repair switch piano 15/16 Amp flush type. Complete all as specified and directed by Engr-in-Charge,Make:- Legrand/ Siemens/ Schneider / L&T.
S&F in repair Angle/ Batten holder Complete all as specified and directed by Engr-in-Charge, Make:- Legrand/ Siemens/ Schneider / L&T.
S&F in repair 5 Amps switch socket combination 3/5 pin type along with box. Complete all as specified and directed by Engr-in-Charge,Make:- Legrand/ Siemens/ Schneider / L&T.
S&F in repair 15 Amps switch socket combination 3/5 pin type along with box. Complete all as specified and directed by Engr-in-Charge,Make:- Legrand/ Siemens/ Schneider / L&T.
S&F in repair MCB single pole 10 Amp, Complete all as specified and directed by Engr-in-Charge, Make:ABB/Siemens/Hager.
S&F in repair MCB single pole 16 Amp, Complete all as specified and directed by Engr-in-Charge,Make:ABB/Siemens/Hager.
S&F in repair MCB single pole 20 Amp, Complete all as specified and directed by Engr-in-Charge, Make:ABB/Siemens/Hager.
S&F in repair MCB single pole 32 Amp, Complete all as specified and directed by Engr-in-Charge,Make:ABB/Siemens/Hager.
S&F in repair MCB double pole 40 Amp, Complete all as specified and directed by Engr-in-Charge,Make:ABB/Siemens/Hager.
S&F in repair MCB double pole 63 Amp, Complete all as specified and directed by Engr-in-Charge,Make:ABB/Siemens/Hager.
S&F in repair LED bulb thread/pin type of capacity 5 Watt Complete all as specified and directed by Engr-in-Charge, Make :Make:Syska /GE /Philips /Crompton
S&F in repair LED bulb thread/pin type of capacity 10 Watt, Complete all as specified and directed by Engr-in-Charge, Make :Make:Syska /GE /Philips /Crompton
S&F in repair MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Engr-in-Charge, Make:ABB/Siemens/Hager.
S&F in repair MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Engr-in-Charge Make:ABB/Siemens/Hager.
S&F in repair MCB DB 12 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Engr-in-Charge. Make:ABB/Siemens/Hager.
S&F in repair MCB with 2 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Engr-in-Charge. Make:ABB/Siemens/Hager.
M&L for Insulation tape of size 32/40mm of R, Y, B colour.Complete all as specified and directed by Engr-in-Charge.
Supply, lying and fixing in repair service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed inservice connections suspended by insulating hangers notmore than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm including taking down.Complete all as specified and directed by Engr-in-Charge.Make: Polycab/Finolex/KEI /Universal .
S & F in repair Sub main wiring using two runs of single core PVC insulated cable with copper conductor multistranded 1100 volts of sizes 6.0 Sqmm through existing/ new non metalic PVC casing capping including copper earth wire in green colour of size 6.0 Sqmm connection to DB with thimbling Complete all as specified and directed by Engr-in-Charge. (Note:- Two runs of sub main wire including earth wire and rigid non metalic PVC casing capping shall be measured as one unit per RM) Make: Polycab/Finolex/KEI /Universal .
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.5 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. (Note : The rate is inclusive of necessary earth work, RFR and removal etc )
Supply and fixing in repairs heating element including rubber gasket & washer etc of capacity 1.5 KW suitable for existing make and shape Complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs heating element including rubber gasket & washer etc of capacity 2 KW suitable for existing make and shape Complete all as specified and directed by Engr-in-Charge.
S&F in repairs thermostat including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 / 35 / 50 ltrs including taking down existing unserviceable thermostat Complete all as specified and directed by Engr-in-Charge.
S&F in repairs fusible plug melting at 90 - 100 degrees Centigrade including taking down existing uncerviceable fusible plug Complete all as specified and directed by Engr-in-Charge.
S&F in repairs high pressure valve with dead weight suitable for 25 / 50 ltrs capacity Geysers including taking down existing unserviceable high pressure valve Complete all as specified and directed by Engr-in-Charge.
S&F in repairs PVC connecting pipe 18" long with brass adopters suitable for Hot/Cold water and connecting up with complete for 25 /35 / 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe Complete all as specified and directed by Engr-in-Charge.
S&F in repairs bottom covers (set of two halves) duly painted made out of Aluminium / MS sheet of 18 SWG suitable for 25 / 35 / 50 ltrs capacity Geysers including taking down existing unserviciable bottom covers Complete all as specified and directed by Engr-in-Charge.
S&F in repairs base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly Complete all as specified and directed by Engr-in-Charge.
S&F in repairs brass non-return valve(Check valve) 15 mm bore with necessary GI specials Complete all as specified and directed by Engr-in-Charge. Make: Kirti/Zoloto/Shakti
M&L for repairs to water heater inner vessel including brazing, welding, testing for a pressure of 3kg / Sq.cm., re-assembling of any capacity Geysers Complete all as specified and directed by Engr-in-Charge.
S&F in repairs indication lamp for 25 / 35 / 50 ltrs capacity Geysers including taking down existing unserviceable indication lamp Complete all as specified and directed by Engr-in-Charge.
Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sludges, blockages, dust, etc and re-assembling up to proper functioning Complete all as specified and directed by Engr-in-Charge.
Material and labour for servicing, disconnecting the filter bed from the indoor unit of AC's of various sizes cleaning the filter beds & copper fins, removal of complete dirt deposited inside the cooling coil fins area by spary of scale removing agent and flushing out with fresh water till removal of complete dirt from the fins area and flushing out with air blower and refixing the same in existing position complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for chemical servicing of the out door unit of any capacities by dismantling the sheet metal parts, apply the organic compound of scale remover to the air cooled condenser fins & tube area, and flushing through forced method, till removal the complete scale deposit across the fins & tube and cleaning, fixing the sheet metal parts, fan blades, etc. Complete all as specified and directed by Engr-in-Charge.
Material and labour for taking down unserviceable burnt compressor, supply and fix scroll type new compressor of existing unit make suitable for 1.5/2 TR air cooled split type unit and rectify the control wiring defects if any, connecting back all controls and refrigerant piping after necessary modification as required for system, pressure testing with nitrogen gas under constant pressure of 300 PSI Kg/sq.cm for minimum 08 hours vacuumising, gas charging, commissioning and checking the performance of the system Complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of hard drawn copper pipe size suitable for existing one and connecting with indoor to outdoor unit of AC Plant along insulating rubber sleeves and including brazing omplete all as specified and directed by Engr-in-Charge.
Repair/Maintenance of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA Complete all as specified and directed by Engr-in-Charge.Make:- V- gaurd/ Microtek/ Godrej/ AE
Supply and charging of refrigerant gas R-22/R-134 upto sufficient pressure for compressor of 2 ton capacity window type /split type ACs including connected works like pressure testing with nitrogen before filling of refrigeratn gas including cutting of copper tubing and brazing and refixing in position Complete all as specified and directed by Engr-in-Charge.
Dismantling old unsv air swing fan motor and replacing with new one suitable for 1.5/2 ton capacity split AC existing make and model. Complete all as specified and directed by Engr-in-Charge.
Dismantling old unserviceable condenser fan motor suitable for 1.5/2 ton capacity window /split type AC and replacing by new one of existing make and model.Complete all as specified and directed by Engr-in-Charge.
Supply and replacing old and defective PCB card for indoor unit of same model amd make suitable for 1.5/2 TR capacity split type units.Complete all as specified and directed by Engr-in-Charge.
S&F in repairs exhaust fan/brisk air fan of size 200 mm sweep, non matallic. Complete all as specified and directed by Engineer-In-Charge. Make : Havells/ CG/Bajaj.
S&F in repairs Plug top 5/6A 240VComplete all as specified and directed by Engineer-In-Charge. Make:- Legrand/ Siemens/ Schneider / L&T.
S&F in repairs Plug top 15/16A 240V Complete all as specified and directed by Engineer-In-Charge.Make:- Legrand/ Siemens/ Schneider / L&T.
M/S KULBIR SINGH SODHI AND CO
M/S VALLEY ENTERPRISES
M/S G M DAR AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .