| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 2 2F NORTH SALAPATTI THIRUVELLARAI VIA MANACHANALLUR TK TRICHY DT | MANACHANALLUR | TRICHY | TAMIL NADU | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
1 Dec 2020, 2:00 pmClosed
The Superintending Engineer/ TEDC/ Metro/ Trichy
Office of the Superintending Engineer, Trichy Electricity Distribution Circle, Metro, Mannarpuram, Trichy-20.
Improvement works by providing vehicle shed, false ceiling works in EEs chamber, wiring works to control with MCBs for accommodating EE/OM/SRIRANGAM division office at old Srirangam 33/11 kvss.
2020_EB_185248_1
Specification No.28/2020-21
Open Tender
Civil Works
Works
30 days
SRIRANGAM
REFER BQR IN TENDER SPEC
2 documents required · 2 mandatory
₹0
₹2,000
Yes
7 Dec 2020
18 Nov 2020
2 Dec 2020
18 Nov 2020
1 Dec 2020
18 Nov 2020
18 Nov 2020 - 30 Nov 2020
Amount
Supplying and fixing of powder coated roofing sheet over steel section, rectangular tubes, angles, plates, flats, etc., including cost of all materilas, labour, etc., complete as directed by the field engineer.
Supplying,fabricating,erecting and fixing of 10 mm thick plaster of paris plain sheet (gyprock Pop board - Saint Gobain make) for false ceiling at a height of 3 m from the existing floor level,including cost of all materials, lead, lift, fabrication, carving, providing cornice work, droping design work,erection charges, cleaning and removal of debris from the work site, Interior painting with two coats of approved interior emulsion over one coat of primer .The False Ceiling design will be provided and execution of work is to be carried out as per the drawing and without any deviation etc., complete.
Supplying, fixing and laying of 50 mm dia PVC pipe 10 Kg/cm2 for water supply arrangement including cost of all materials, labour, lead, lift etc complete.
Fabricating, Supplying and fixing in position of Aluminium Grill of Standard Pattern (Diamond Shape) - 6mm thick including 'F' (or) 'H' Section , labour, lead , lift, etc.,complete.
Repairing the existing damaged Aluminium door/glass windows by replacing the broken glass panels, placing in position, providing necessary fittings as instructed by the Engineer at site including painting , cost of all labour, lead, lift etc., complete.
Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Supply and fixing of Cuddapah Slab Sink of size 600mm x 600mm x 200mm with 32mm dia 'B' Class G.I. waste water pipe & 32mm dia C.P. waste coupling as directed by the field engineer at site including cost of all materials, labour, lead, lift etc complete.
Supply and fixing of Cuddapah Slab Sink of size 600mm x 600mm x 200mm with 32mm dia 'B' Class G.I. waste water pipe & 32mm dia C.P. waste coupling as directed by the field engineer at site including cost of all materials, labour, lead, lift etc complete.
Supply and run of 3 of 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable flexible conduit pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting painting of suitable colour
Supply and fixing of horizontal type 6 way single pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 2 pole MCB isolater as incoming and 3 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make)
Supply and fixing of horizontal type 12 way double pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 4 pole MCB isolater as incoming and 8 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make)
Supply and fixing of 32A DP MCB Isolator whereever necessary as directed by the field engineer.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .