AGMCOM
INCOD OFFICE NAVAL DOCKYARD SBS MARG MUMBAI 400023
UPGRADATION AND MR ROUTINES OF OMNIPURE MAKE SEWAGE TREATMENT PLANTS (STPS) AND ASSOCIATED SYSTEMS FITTED ONBOARD INS MUMBAI
2021_NAVY_469210_1
DYT/IRC/20-21/106(A)/PL-IN/ MBI-STP/255
Single
Marine Services
Item Rate
360 days
NAVAL DOCKYARD MUMBAI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
NAVAL DOCKYARD MUMBAI
2 Sept 2021
19 Aug 2021
2 Sept 2021
19 Aug 2021
1 Sept 2021
25 Aug 2021
25 Aug 2021
180 days
Amount
CLEANING AND PAINTING OF V1 AND V2 TANK OF 6MC PLANT
CLEANING AND PAINTING OF V1, V2 & V3 TANK OF 12 MX PLANT
RENEWAL OF V1 TANK OF 6MC PLANT
RENEWAL OF V2 TANK OF 6MC PLANT
RENEWAL OF V1 TANK OF 12MX PLANT
RENEWAL OF V2 TANK OF 12MX PLANT
RENEWAL OF V3 TANK OF 12MX PLANT
REPLACE GLASS LEVEL TUBES FOR TANK LEVEL INSPECTION
REPAIR AND CHEMICAL CLEANING OF 6MC BOOK CELL
REPAIR AND CHEMICAL CLEANING OF 12MX BOOK CELL.
RENEWAL OF COMPLETE 12MX BOOKCELL
REPLACEMENT OF OBD PUMP AND MOTOR
OVERHAUL OF MACERATOR PUMP. REPLACE DEFECTIVE COMPONENTS
REPLACEMENT OF MACERATOR PUMP MOTOR
OVERHAULING OF IMO PUMP
RENWAL/ OVERHAUL OF CONTROL PANEL, REPLACE DEFECTIVE COMPONENTS
CALIBRATION AND SERVICEABILITY CHECK OF VOLTMETER, AMMETER. REPLACE DEFECTIVE COMPONENTS
CALIBRATION AND SERVICEABILITY CHECK OF TRANSFORMER UNIT. REPLACE DEFECTIVE COMPONENTS
REMOVAL AND RENEWAL OF BLOWER/ ROTARY AIR COMPRESSOR AND MOTOR ASSEMBLY
RENEWAL/ REPLACEMENT OF FLOAT LEVEL SWITCHES
REPLACEMENT OF DEFECTIVE OBD VALVES 12 MX PLANT
REPLACEMENT OF DEFECTIVE OBD VALVES 6MC PLANT
OVERHAUL OF SOLENOID VALVES AND REPLACEMENT OF DEFECTIVE COMPONENTS
REPLACEMENT OF PVC PIPE AND VALVES
TESTING OF SEWAGE EFFLUENT (BIOLOGICAL OXYGEN DEMAND, TOTAL SUSPENDED SOLIDS AND FECAL COLI FORM) OF STP AS PER MAPOL STANDARD. ISSUE TEST CERTIFICATE FORM GOVT APPROVED LAB.
PROVING OF PLANT
PROVIDE INTERNATIONAL SEWAGE POLLUTION PREVENTION (ISPP) CERTIFICATE VALID FOR A DURATION OF FIVE YEARS FROM A STATE AUTHORISED ACCREDITED AGENCIES AS SPECIFIED IN ANNEX IV OF MARPOL 73/78
GASKET TANK V1 6MC
GASKET TANK V2 6MC
VALVE, SOLENOID, 1/2", BRASS, 120V (MOUNTED AT SPRAYHEAD DEVICE)
M16 X 75, SS316 NUT & BOLT WITH DOUBLE WASHER
M16 X 65, SS316 NUT & BOLT WITH DOUBLE WASHER
M16 X 55, SS316 NUT & BOLT WITH DOUBLE WASHER
M16 X 120, SS316 NUT & BOLT WITH DOUBLE WASHER
PAINT SIGMA 280 PRIMER 75 MICRON
PAINT SIGMA 300 BLACK 60 MICRON
PAINT SIGMA 630 GREY 60 MICRON
FLOAT SWITCH ASSEMBLY (PLASTIC NEMA 4X CONNECTION)
SITE TUBE ASSEMBLY -1/2", OTS UNITS, (SASITUBEASSY - 2)
CONTROLLER, FLOW, 0.5 GPM
CONTROLLER, FLOW, 5.0 GPM
GASKET, NEOPRENE, FOR 1/2"-150# FLANGE
GASKET, NEOPRENE, FOR 3/4"-150# FLANGE
GASKET, NEOPRENE, FOR 1"-150# FLANGE
GASKET, NEOPRENE, FOR 1-1/2"-150# FLANGE
GASKET, NEOPRENE, FOR 2"-150# FLANGE
GASKET, NEOPRENE, FOR 3"-150# FLANGE
GASKET, NEOPRENE, FOR 4"-150# FLANGE
2" NB, SS 316, FLANGE END AS PER ANSI B16.5 RF, GATE VALVE
4" NB, SS 316, FLANGE END AS PER ANSI B16.5 RF, GATE VALVE
2" NB, SS 316, FLANGE END AS PER ANSI B16.5 RF, NON RETURN VALVE
PVC PIPING AND VALVES
OVERBOARD PUMP & MOTOR ASSY.COMP- (TEFC) -BALDOR IP-56
OIL, QUART, MACERATOR, ISO 32 SYNTHETIC
REBUILD KIT (MECHANICAL SEAL, BEARING, BUSHING, AND SOFT PARTS)
JETS DISCHARGE PUMP
VOLTMETER, ANALOG, 0‐150 VDC
AMMETER, ANALOG, 0‐50 ADC
FUSE, 2 AMP, 600V
AMMETER, ANALOG, 0‐50 ADC;
VOLTMETER, ANALOG, 0‐150 VDC;
STARTER, OVERLOAD, MANUAL 1.6-2.5 AMPS
FUSE, 6/10 AMPS (REJECTION TYPE)
BOLTS, 5/16", 316 SS
PLATE, ELECTRODE, 4/6/8 PRIMARY CATHODE
WASHER, FLAT 3/8" 316 SS
COMPLETE BLOWER WITH MOTOR
EJECTOR, ABS MATERIAL (VENT LINE)
VALVE, SOLENOID, 1/4", BRASS, 120V (MOUNTED ON CONTROL PANEL)
1 HP MOTOR(TEFC) - BALDOR IP-56
2 HP MOTOR(TEFC) - BALDOR IP-56
SPRAY HEAD ASSY, 12MX/15MX UNIT, PVC TYPE
SHUNT, 50MV-50 ADC
TRANSFORMER, MAIN, 18KVA
P.C. BOARD, 3 PHASE
P.C. BOARD, 3 PHASE.
stage.html
html • 0.02 MB
finance_523140.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .