Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.4 L+₹51,800 (6.57%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹10.3 L+₹2.4 L (30.0%)Rejected-AOC XIV 718 CLINT ROAD VADAVUCODE PUTHENCRUZ AMBALAMEDU PO AMBALAMEDU ERNAKULAM KERALA 682303 | ERNAKULAM | KERALA | 682303 | L3 | Rejected-AOC L3 | |
| 4 | L4₹15.9 L+₹8.0 L (102.1%)Rejected-AOC 32 1089 KALAMASSERY CHANGAMPUZHA NAGAR COCHIN ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
11 Oct 2023, 11:30 amClosed
NITHIN C S
SM (P and P)-CD
Renovation and Repairing of various office rooms in Technical office building at FACT-CD, Ambalamedu.
2023_FACT_773420_1
04026/2023-2024/E28190
Limited
Miscellaneous Works
Item Rate
90 days
AMBALAMEDU
This tender is issued on limited tender basis from the registered bidders of FACT (CD)
4 documents required · 4 mandatory
₹0
₹12,000
Yes
26 Oct 2023
26 Sept 2023
12 Oct 2023
26 Sept 2023
11 Oct 2023
26 Sept 2023
Renovation and Repairing of various office rooms in Technical office building at FACT-CD, Ambalamedu
Dismantling/disconnection of existing light fittings, ceiling fans, switch boards, telephone cables, wires etc from the chamber of CMD. The disconnected and dismantled electrical fittings shall be transported to the electrical workshop - PH1.
Dismantling/disconnection of existing light fittings, ceiling fans, switch boards, telephone cables, wires etc from the chamber of CGM and PA' to CGM's office. The disconnected and dismantled electrical fittings shall be transported to the electrical workshop - PH1.
Dismantling/disconnection of existing light fittings, ceiling fans, switch boards, telephone cables, wires etc from the chamber of GM. The disconnected and dismantled electrical fittings shall be transported to the electrical workshop - PH1.
Supply and installation of recess mounted profile lighting. The scope of work includes fixing of aluminium profiles(min 25mm width) after cutting false ceilings/supports/blanking plates if required, supply and installing LED strip lights (cool white), drivers and diffusers of reputed make without any dark points, wiring, connection and commissioning of the profile light. All the required materials including blanking plates, aluminium profiles, drivers, diffusers, LED strips, connectors etc shall be supplied by the contractor. The LED strip supplied shall have minimum 264 LEDs/meter and shall have OEM warranty/guarantee of minimum 1 year. Acceptable makes of LED strip and driver: Philips, Luker, Havells. Acceptable makes of Aluminium profile: Alpha or equivalent.
Supply of BLDC, 5 star decorative ceiling fan including all accessories, remote etc and having the following specifications: Sweep: 1200mm. Air delivery > 200CMM. Colour: Gloss Black. OEM Warranty: 5 year. Acceptable make & model: Crompton Energion Stylus or equivalent
Installation of ceiling fans. The scope of work includes installation of ceiling fans after dismantling the existing fans. All the accessories including suitable PVC connectors, ceiling rose(if required) shall be supplied by the vendor. Cut out in false ceiling for connecting down rods to hook (if required) shall be made by the contractor.
Supply of recess mounting downlighter including all accessories and having the following specifications: Power supply: 220-240V, 1 ph, 50Hz Colour: Cool day light Wattage: 15W Form factor: Square Life: Minimum 45k hrs Surge protection: up to 2.5 kV with wide voltage protection 160-360V The fitting shall have no visible flickering, UV/IR and low glare to prevent eye strain Make: Philips DuraSlim or equivalent
Installation of downlighters. The scope of work includes fixing of square shaped downlighters to the false ceiling and providing power connections using suitable connectors and energising. All the accessories including suitable PVC connectors, fixing clamps/clips shall be supplied by the vendor.
Supply of Double RJ11 telephone socket. Legrand Myrius Charcoal Grey, Cat. No:679463 or equivalent
Supply of RJ45 socket for Utp Cat 6 Tool-less With Shutter. Legrand Myrius Charcoal Grey, Cat. No 679465 or equivalent
Supply of Combi Twin USB 3100 mA Multistandard Socket Type A & Type C. Legrand Myrius Charcoal Grey Cat. No 679493 or equivalent
Supply of 6A 5 Pin Universal Socket. Legrand Myrius Charcoal Grey Cat. No 679428 or equivalent
Supply of 6A Switch 1 Way. Legrand Myrius Charcoal Grey Cat. No 679400 or equivalent
Supply of 6/16 A Socket. Legrand Myrius Charcoal Grey Cat. No 679430 or equivalent
Supply of 16A Switch 1 Way. Legrand Myrius Charcoal Grey Cat. No 679409 or equivalent
Supply of 25 A Socket. Legrand Myrius white Cat. No 679232 or equivalent
Supply of 25A Switch 1 Way. Legrand Myrius White Cat. No 679216 or equivalent
Supply of metal flush box 1/2 M. Legrand Myrius Cat No. 689007 or equivalent
Supply of metal flush box 3 M. Legrand Myrius Cat No. 689008 or equivalent
Supply of metal flush box 4 M. Legrand Myrius Cat No. 689009 or equivalent
Supply of metal flush box 6 M. Legrand Myrius Cat No. 689010 or equivalent
Supply of metal flush box 8 M. Legrand Myrius Cat No. 689042 or equivalent
Supply of metal flush box 12/16 M, 2 row x 6M. Legrand Myrius Cat No. 689011 or equivalent
Supply of plate and frame, 1M of modular switches. Legrand Myrius Ice black Cat No. 679541 or equivalent
Supply of plate and frame, 2M of modular switches. Legrand Myrius Ice black Cat No. 679542 or equivalent
Supply of plate and frame, 3M of modular switches. Legrand Myrius Ice black Cat No. 679543 or equivalent
Supply of plate and frame, 3M of modular switches. Legrand Myrius white Cat No. 679503 or equivalent
Supply of plate and frame, 4M of modular switches. Legrand Myrius Ice black Cat No. 679544 or equivalent
Supply of plate and frame, 6M of modular switches. Legrand Myrius Ice black Cat No. 679546 or equivalent
Supply of plate and frame, 8M of modular switches. Legrand Myrius Ice black Cat No. 679548 or equivalent
Supply of plate and frame, 12M of modular switches. Legrand Myrius Ice black Cat No. 679552 or equivalent
Installation of 1M switch box. The installation scope shall include chipping the wall/pillar and concealing the switch box, mounting the frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
Installation of 2M switch box. The installation scope shall include chipping the wall/pillar and concealing the switch box, mounting the frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
Installation of 3M switch box. The installation scope shall include chipping the wall/pillar and concealing the switch box, mounting the frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
Installation of 4M switch box. The installation scope shall include chipping the wall/pillar and concealing the switch box, mounting the frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
Installation of 6M switch box. The installation scope shall include chipping the wall/pillar and concealing the switch box, mounting the frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
Installation of 8M switch box. The installation scope shall include chipping the wall/pillar and concealing the switch box, mounting the frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
Installation of 12M switch box. The installation scope shall include chipping the wall/pillar and concealing the switch box, mounting the frame and cover/front plate after fixing the switches/sockets, wiring the switch box, termination of 1.5/2.5 sq.mm multi stranded cables etc. Separate earth shall be provided to the switch board. The materials such as SS screws, PVC/nylon grips for mounting the switch box etc. shall be supplied by the contractor.
Supply of 20A, DP MCB, C curve with DP metal enclosure suitable for recess mounting. Acceptable make of MCB: Siemens, Schneider, ABB, Legrand, Havells, L&T, C&S. Aceptable make of enclosure: Legrand Ekinox Cat. No. 507791 or equivalent.
Installation of 20A DP MCB and enclosure. The scope of work includes chipping the wall, fixing the metal enclosure, cement plastering to smooth finish, re-applying putty, fixing cover plate, wiring up and connecting phase, neutral and earth links etc.
Supply of 2 nos of 20A, DP MCB, C curve with FP metal enclosure suitable for recess mounting. Acceptable make of MCB: Siemens, Schneider, ABB, Legrand, Havells, L&T, C&S. Aceptable make of enclosure: Legrand Ekinox Cat. No. 507793 or equivalent.
Installation of twin 20A DP MCB and FP enclosure. The scope of work includes chipping the wall, fixing the metal enclosure, cement plastering to smooth finish, re-applying putty, fixing cover plate, wiring up and connecting phase, neutral and earth links etc.
Supply of exhaust fan with louver suitable for Bathroom with the following specifications: Power: min 32W Operating voltage: 200-250V OEM Warranty: 1 year Blade Length : 200 mm Acceptable make : Havells Ventil Air DX 200mm.
Installation of exhaust fans. The scope of work includes installation of exhaust fans. All the accessories including suitable PVC connectors, fixing accessories shall be supplied by the vendor.
Supply of High lumen, 4 feet LED batten light with all accesories having the following specifications: Colour temperature: 6500K, cool white Lumen output: 2200lm or more Power:20-22W Operating voltage: 200-250V OEM Warranty: 1 year Make: Wipro garnet plus 22 or equivalent
Installation of LED batten. The scope of work includes fixing of the LED battens to the wall using suitable clamps, providing power connections to the battens using flexible cables to the nearest JB/ceiling rose etc. All the materials required for completing the work including connecters,clamps etc shall be supplied by the contractor.
Supply of LED mirror lamp with rotating shade/flexible neck with cool/warm white LED. Power: min 6W.
Installation of LED mirror lamps. The scope of work includes installation of LED mirror lamp after dismantling the existing lamps if any. All the accessories including suitable PVC connectors and fixing accessories shall be supplied by the vendor.
Rerouting of existing wirings in CMD's chamber. The scope of work involves disconnection and dismantling of existing CTS wiring, termination of the wires at both ends using 16A closed PVC/bakelite connecters mounted inside suitable surface mounted metal junction boxes of reputed make. The scope of work involves fixing of the metal enclosures on wall using suitable fastners. All the accessories including suitable PVC connectors and fixing accessories shall be supplied by the vendor. The JBs shall have hylam/suitable metal cover and shall be certified by the engineer-in-charge.
Rerouting of existing wirings in CGM's chamber and PA to CGM's room. The scope of work involves disconnection and dismantling of existing CTS wiring, termination of the wires at both ends using 16A closed PVC/bakelite connecters mounted inside suitable surface mounted metal junction boxes of reputed make. The scope of work involves fixing of the metal enclosures on wall using suitable fastners. All the accessories including suitable PVC connectors and fixing accessories shall be supplied by the vendor. The JBs shall have hylam/suitable metal cover and shall be certified by the engineer-in-charge.
Rerouting of existing wirings in GM's room. The scope of work involves disconnection and dismantling of existing CTS wiring, termination of the wires at both ends using 16A closed PVC/bakelite connecters mounted inside suitable surface mounted metal junction boxes of reputed make. The scope of work involves fixing of the metal enclosures on wall using suitable fastners. All the accessories including suitable PVC connectors and fixing accessories shall be supplied by the vendor. The JBs shall have hylam/suitable metal cover and shall be certified by the engineer-in-charge.
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 1.5 sq.mm copper red/blue/yellow wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 1.5 sq.mm copper black wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 1.5 sq.mm copper green wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco
Installation of the 1.5 sqmm copper wires. The installation scope shall include drawing of cables through PVC conduits from switch board/JBs to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit.
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper red/blue/yellow wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper black wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco
Supply of 650/1100V, PVC insulated, FRLS ISI marked ,multi stranded 2.5 sq.mm copper green wires. Acceptable makes: Finolex, RR kabel, Polycab, Traco
Installation of the 2.5 sqmm copper wires. The installation scope shall include drawing of cables through PVC conduits from switch board/JBs to light fittings/fan/plug points/junction boxes and termination of cables at the above points. Cables shall be jointed or tapped only at the junction box/switch boards. Care should be taken to see that not more than 6 cables are taken through a single conduit.
Supply of 0.5 Sq.mm 10 pair industrial flexible telephone cable. Acceptable make: Finolex, Polycab, Delton or equivalent
Installation of the 0.5 sqmm 10 pair industrial flexible telephone cable. The installation scope shall include drawing of cables through PVC conduits from switch box/JBs to RJ11 telephone sockets/ switch boxes/junction boxes and termination of cables at the above points. Care should be taken to see that not more than 3 cables are taken through a single conduit.
Supply of 19/20mm medium type ivory coloured rigid ISI marked PVC electrical conduit with all accessories such as junction boxes, couplers, bends, tee, elbow ,G.I/PVC saddles, screws,wall/ceiling plugs etc. required for the surface conduit wiring.
Installation of PVC conduit wiring system. The installation scope shall include fixing of PVC conduits and its accessories to the walls / ceilings /columns etc. and neatly clamping at a uniform spacing of 450mm using GI saddles, tagging, drilling holes, minor civil work etc.Suitable sized junction boxes shall be provided at regular intervals. The materials required for the installation such as PVC saddles, screws, nuts and bolts junction boxes etc shall be supplied by the contractor. The erection scope shall include, drilling holes, chipping ,plastering, minor civil works etc.
VIJAYAN K K
Vallooran Constructions
GERESH ELECTRICALS PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_813029.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .