Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
5 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical)
Comprehensive Annual Maintenance Contract for Air Conditioner System, DG set & ELV system & Related Item at Trinetram , Police bhavan, Sector-18, Gandhinagar. ( Two Years)
265681
NIT-02 (2025-26) Electrical Sr.No.2
Open
Electrical - AC Maintenance
Works
Gandhinagar
12 documents required · 11 mandatory · 1 optional
₹900
Yes
GUJARAT STATE POLICE HOUSING CORPORATION LTD, Payable at Gandhinagar
₹17,000
Yes
16 Jan 2026
16 Jan 2026
16 Jan 2026
5 Feb 2026
16 Jan 2026
Name of Work :- Comprehensive Annual Maintenance Contract for Air Conditioner System, DG set & ELV system & Related Item at
Trinetram , Police bhavan, Sector-18, Gandhinagar. ( Two Years)
Item Estimated Rate in
Item Description Unit
No. Words Figures
1 Cost Of Comprehensive Maintenance of floor mounted, bottom discharge, 16.0 TR (8.00 X2
nos)air cooled dx type precision air conditioning unit equipped with r410a green refrigerant along
with most advanced industry technology guaranteeing precise control of temperature. with Ref.
Gas, copper piping , drain pipe control cable, power supply cable, Softner plant, Indoor & Out
door stands & Extended piping kit & parts (a)16.00 TR( 8X2 nos.), 5495 CFM, St. Pr. 65 mm as
per attached maintenance schedule.OEM/ Dealer has to Provide fitness certificate at the time of
a 1st year Per Years RS: Three lac Thirty Three
Thousand Five Hundred
b 2nd years Per Years RS: Three lac Thirty Three
Thousand Five Hundred
2 Cost Of floor mounted, bottom discharge, 8.0 TR air cooled dx type precision air conditioning unit job. RS: Twenty Five Thousand
repairing work including fault diagnosis, repair or replacement of mechanical, electrical, only
refrigeration and control components, calibration of temperature and humidity sensors, testing,
commissioning and performance verification to maintain precise environmental conditions in server
rooms/data centers.”
3 Cost Of Comprehensive Maintenance of 98 HP VRF type Air conditioner System Including
Outdoor unit , Indoor unit,AHU, Cordless Remote, Corded Remote,centralized monitor PC
Central Remote, Copper Pipe, Drain pipe, control / communication cable , and Parts of Air
conditioner system as per attached maintenance schedule.OEM/ Dealer has to Provide fitness
certificate at the time of releasing S.D
Item Estimated Rate in
Item Description Unit
No. Words Figures
a 1st year Per Years RS: Two lac Eighty Four
Thousand Four Hundred
Thirty Three only
b 2nd years Per Years RS: Two lac Eighty Four
Thousand Four Hundred
Thirty Three only
4 Cost Of Comprehensive Maintenance of 6.0 Ton inverter type Split Aircondationer System
Including Outdoor unit , Indoor unit, Cordless Remote,Sequential controller, Copper Pipe, Drain
pipe, control / communication cable , and Part of Aircondationer system. including preventive
service per years ( Two Dry & Two Chemical Service Per year) & break down maintenance (2.0
TonX3.0 Nos) OEM/ Dealer has to Provide fitness certificate at the time of releasing S.D
a 1st year Per Years RS: Fourteen Thousand
b 2nd years Per Years RS: Fourteen Thousand
5 Supplying colourless, odourless, non-flammable gas R-22(CHF2CL) Kgs. RS: Five Hundred Nine
6 Supplying & topping colourless non inflammable refrigerant Gas R-410 or as per requirement. Kgs. RS: Nine Hundred
Item Estimated Rate in
Item Description Unit
No. Words Figures
7 Cost of all Comprehensive maintenance of 250 KVA Rating D.G. set for continuous trouble free
operation . including four preventive service per years & break down maintenance, Agency has to
quote rate accordingly.Agency has to also provide the fitness certificate from DG manufacturer and
submit to GSPHCL after complation of AMC. .DG sets OEM has to mantain written record of sevice
& maintenance during defect libility period duly singh by police dept.and submited regularly to
GSPHCL. Dg set OEM has to do maintance as per term & Condition in tender. For delay in
rectifying the fault/ Comprihensive maintainance, penalty will be deduced from agency S.D.
1. Replacing the fuel filters & Oil filters. 2. Checking the alignment
and tappet setting. 3. Checking the carbon brushes / AVE.
4. Checking the oil level and replace the oil. 5. Leakages IN/OUT
6. All Electrical wrings including AMF panel . Earthing, Control panel,
Dynamo Setting.
8. RPM setting, Frequency & Voltage Adjustment. 9. Replacing material
like fuel filters, gasket, tappet covers, diode rectifiers, Bridge rectifiers if found defective and in not
working condition. 10. Kindly note that
labour with spares is included in the above. 11. Major Overhauling & Top overhauling
shall be included in scope of Agency.
12. including Replacement of Battery if it is not working . 13. replace Outer Air Element, Filter
Element Primary, Oil Filter, Filter Element Secondary, Gesket, Valve Cover, Belt Alternator, Fan
Belt, Lube Oil, Coolant etc. as per site required & working hours of D.G set. OEM/ Dealer has to
Provide fitness certificate at the time of releasing S.D (A) Continuous Rating of 250 KVA
a 1st year Per Years RS: Two lac Thirty Four
Thousand Two Hundred
b 2nd years Per Years RS: Two lac Thirty Four
Thousand Two Hundred
Item Estimated Rate in
Item Description Unit
No. Words Figures
8 SITC of 24 x 10/100/1000BASE-T PoE ports Each RS: Thirty One Thousand
4 x Gigabit RJ45/SFP Combo ports Six Hundred Eighty only
Advanced L2 switching and security features
L2+ Static Routing
Optional “standard mode” or “surveillance mode” management user interface
193 W PoE budget ( D-link, Cisco, Juniper , HP, Netgear make & model Strictly approved by EIC
subject to above specification )
9 SITC of Maximum distance of up to 10 km Each RS: Four Thousand
Hot-pluggable Seven Hundred Fifty Four
Single-mode fiber only
1000BASE-LX (IEEE 802.3z standard)
Duplex LC connector
MSA, RoHS-complian ( D-link, Cisco, Juniper , HP, Netgear make & model Strictly approved by
EIC subject to above specification )
10 SITC of LIU 12 PORT Rack Mount - Loaded (LC) SM having flowwing future:- Cold rolled Steel Each RS: Six Thousand Eight
body with Aluminum front & top cover for light mounting with powder coating. Hundred Thirty Three
• Slim 1U Unit Mounting Height only
• Can manage both splices and terminations
• Preassembled shelves in multiple configurations
• Can include adapter panels for maximum 48LC, 48SC, 36ST or 36FC terminations
• Magic stickers built-in for 900um tight buffered fiber storing
• Capable of storing up to 3 meters of 900um tight buffered fiber per adapter
• Snap-in locker design, easy to change adapter panels for various connector patching
• Removable front and top covers for better access to interior of LIU
• Removable rubber grommet allows for pre-terminated fiber trunk instillation, protects cable, and
minimizes dust build-up
• Accessory kit consists of cable ties, mounting ear screws and cable saddle ( Molex, Legrand, D-
link Make Only )
Item Estimated Rate in
Item Description Unit
No. Words Figures
11 SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- Minimum 3 meter ( Molex, Legrand, D- Each RS: One Thousand
link Make Only ) Eight Hundred Eighty Three
12 SITC of O. F.Cable 06F Outdoor - Optical fibres cable should be in water blocked loose tube, Mtr. RS: Fifty only
taped, corrugated steel tape armoured (STA) polyethylene (HDPE) outer sheathed embedded with
two steel wires on the periphery. The cables are with UV Stabilized PE Jacket and protected from
Rodent attacks. with necessaruy splicing ( Molex, Legrand, D- link Make Only )
13 Supply and fixing 7 ft Cat-6 gigaspeed patch codes for computer data cable ( Molex, Legrand, D- link Each RS: One Hundred Ninty
Make Only ) Nine only
14 Supply and fixing 3 ft Cat-6 gigaspeed patch codes for computer data cable. ( Molex, Legrand, D- link Each RS: One Hundred Fifty
Make Only ) Five only
15 SITC of specified make Y color Cat 6-A Computer data wire ( Molex, Legrand, D- link Make Only ) Mtr. RS: Seventy Six
16 SITC of specified make X color Cat - 6 voice cable ( Molex, Legrand, D- link Make Only ) Mtr. RS: Forty Seven
17 SITC of 24 x 10/100/1000BASE-T ports Each RS: Fifteen Thousand
4 x Gigabit RJ45/SFP Combo ports Two Hundred Forty Seven
Advanced L2 switching and security features only
L2+ Static Routing
Optional “standard mode” or “surveillance mode” management user interface ( D-link, Cisco, Juniper , HP,
Netgear make & model Strictly approved by EIC subject to above specification )
18 SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded ( Molex, Legrand, D- link Make Each RS: Four Thousand
Only ) Three Hundred Fifty Seven
19 Providing & erecting Modular type accessories mounted on 20G. company Fabricated Galvanised Metal Each RS: One Hundred Fifty
box(a) RJ-11 Telephone Socket ( Honeywell Make) Nine only
Item Estimated Rate in
Item Description Unit
No. Words Figures
20 Providing & erecting Modular type accessories mounted on 20G. company Fabricated Galvanised Metal Each RS: One Hundred Fifty
box(a) Modem Jack for Computer Open RJ-45 ( Honeywell Make) Nine only
21 SITC of PIGTAIL LC SM SIMPLEX LENGTH- 1m ( Molex, Legrand, D- link Make Only ) Each RS: Seven Hundred
Seventy Two only
22 SITC of Jack Cat 6 Keystone UTP ( Molex, Legrand, D- link Make Only ) Each RS: One Hundred Sixty
23 Providing ELV system technician to carry out ELV system maintanance & service work as and Per Day RS: Eight Hundred
required with all requiered instruments & tools , as per instruction of Trinetra incharge officer. Eight y only
Executive Engineer(Ele)
Signature of Contractor G.S.P.H.C.L.
With seal Gandhinagar.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Document
ELE3 specifications Booklet.pdf
Schedule- B.pdf
16.01.2026 N.I.T. ele 2025-26 no-2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .