Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC 1017 A SUBHASH NAGAR BEHIND KHALSA SCHOOL BAREILLY UP | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.2 L+₹1,744.50 (0.05%)Rejected-Finance BUNGALOW NO 21 CANTONMENT BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹38.8 L+₹2.7 L (7.46%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L3 | Rejected-Finance Being 3rd Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Mar 2022, 6:00 pmClosed
GE EAST BAREILLY
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR AND MAINT OF DISTRIBUTION SYSTEM AND ALLIED WORKS, IMPROVEMENT TO WATER SUPPLY INSTALLATION, PUMPING SET OF DIFFERENT CAPACITY CHLORONOME OR DOZING PLANT AND ALLIED WORKS AT MTTC AREA AND BWL UNDER GE (EAST) BAREILLY.
2022_MES_507758_1
8960/E8
Open Tender
Civil Works
Item Rate
183 days
BAREILLY
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE EAST BAREILLY
₹90,000
Yes
16 Mar 2022
14 Feb 2022
16 Mar 2022
21 Feb 2022
14 Mar 2022
28 Feb 2022
14 Feb 2022 - 21 Feb 2022
Amount
Excavation in trenches n.exc 1.5 mtr wide and 1.5 mtr deep for laying of CI/GI pipe lines and getting out in soft/loose soil complete all as spcified and directed
Returning filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as directed
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding1.5 m from starting point complete all as specified and directed.
M & L ductile iron spigot and socket ends centrifugally cast. Class A, in any length, laid in trenches/floors of 150 mm dia with protective linings and coatings complete all as specified Note :- (i) Excavation earthwork and joitnts shall be measured and paid for separately under respective items of schedule ' A ' . (ii) DI / CI pipe fittings shall be measured and paid for separately under respective items of this schedule .
All as per Srl item No. 4 here in before but 100 mm dia
M & L for tyton joints (ISI Mark) complete suitable for the size150 dia bore . Make : SBR (IS-5382))
M & L for tyton joints (ISI Mark) complete suitable for the size100 dia bore . Make : SBR (IS-5382))
M&L for CI / DI fittings such as bends, tapers, Tee, pieces, collars etc for spigot and socketted joint pipes upto 150mm dia bore including taking out of old / unsv complete all as specified and directed.
M & L in repair for Run lead joints (good quality) as per SSR Part I including removing the leaking joints for the sizes 150 dia bore .
M & L in repair for Run lead joints (good quality) as per SSR Part I including removing the leaking joints for the sizes 100 dia bore .
M & L in repair for Run lead joints (good quality) as per SSR Part I including removing the leaking joints for the sizes 80 dia bore .
Supply only AQUAFIT- CHLORINE - 65%-70% (Calcium based granular disinfectant for water treatment, more stable than Chlorine gas, and stronger than Bleaching powder, and sodium Hypochlorite ) in 45 kg Drums. Make : Sree Rayalaseema HI-Strtength HYPO LTD .
Supplying only caustic/ Soda crystals/ Soda Ash powder in 5 Kg vacuum packets complete all as specified and directed
Supplying only Soda lime powder in 25 Kg vacuum packets complete all as specified and directed
M&L for repair to leakage of joint of size upto 100 mm CI/PPR/HDPE pipe mains by cocking and inserting extra lead/spun yard/piece of required size and making good/ leakless the existing joint including necessary excavation and earth work like returning, filling removing etc after testing the jont (Extra lead will be measured and paid seperately)
M&L for repair to leakage of joint of size upto 150 mm CI/PPR/HDPE pipe mains by cocking and inserting extra lead/spun yarn/piece of required size and making good/ leakless the existing joint including necessary excavation and earth work i.e returning, filling, removing etc after testing the jont (Extra lead will be measured and paid seperately)
Supply only lead for filling in CI pipe joints complete all as specified and directed
Repair/rectification of leakage, removal of blockage in individual water connection to residential Qtrs/OTM Accn by disconnecting the branch connections and taing out GI tubing of size 15/ 20 mm including fitting water meter stop cock etc. Cleaning/flushing of pipes and GI fitting as per site requirement for proper connection (Leak proof) including excavation, earth work etc & GI fitting complete all as specified and directed
Repair/ rectification of leakage, removal of blockage in individual water connection to residential Qtrs/OTM Accn by disconnecting the branch connections and taking out GI tubing of size 25/ 40 mm including fitting water meter stop cock etc. Cleaning/flushing of pipes and GI fitting as per site requirement for proper connection (Leak proof) including excavation earth work & GI fitting complete all as specified and directed
Repair/rectification of leakage, removal of blockage in individual water connection to residential Qtrs/OTM Accn by disconnecting the branch connections and taking out GI tubing of size 50 mm including fitting water meter stop cock etc. Cleaning/flushing of pipes and GI fitting as per site requirement for proper connection (Leak proof) including excavatiion & GI fitting complete all as specified and directed
M&L for repair to leakage of CI rising pipe joint /DI Flange joint of RCC OH Tank/Reservoir of any size at any height by making scaffolding staging and taking out worn out rubber packing or old lead joint by heating with blower removing old spun yarn from joint and filling/fixing of new spun yarn and lead in joints including disconnectioin taking down and refixing of old pipe in its position including replacement of US clamps with new clamps made out of MS flat 40mmx5mm and testing the joints for leak free complete all as specified and directed.
S&F in repair rubber coupling suitable for 12.5 to 25 HP pumping set etc complete all as specified and directed.
M&L in repair for installation of electronic Automatic level controller including probe unit, five stage magnetic sensor concealed in S S tube of required length,controlling box including systems incorporated with stage signal,high & low alarm,pump automation as directed capable to one tank from one pump complete including wire etc all as specified and directed
Supply & replacement of DOL Starter 415 Volt suitable for 7.5 HP/ 5.5 KW motor all as direcred and specified.
Supply & replacement of Contactor ML-3 ,suitable to operate 35-45 HP submersible pumping setall as direcred and specified.
Supply & replacement of Contactor ML-4 ,suitable to operate 50-60 HP submersible pumping set all as direcred and specified.
M&L for cleaning of RCC Over Head Tanks capacity 1 lakh gallon removing and taking out sand, sludge and mud etc including disposal of the same at a distance not exceeding 100 mtrs from the tank,including two coats of whitewash on whole internal walls of OH Tank all as directed . NOTE:-All the safety equipments for workers working on OHT and U/G Sumps will be provided by the contactor. Cleaning of OH tank is in every 6 month or contracor is responsible to clean all OH tank two time in their contract at same cost quoted rate, no other payment is binding for item no 27 to 29 for second time during contract.
All as per above item No 27 above but capacity 50000 gallon.
All as per above item No 27 above but capacity 25000/35000 gallon.
M &L for taking out unserviceable submersible pumping set complete with column pipe any capacity and any type from existing bore well carefully without damaging the p/set including connecting parts and lowering the same after repair including provision of suitable size of nut & bolts with washer and suitable packing for column pipes and connection of submersible cable complete of capacity 11 HP to 50 HP all as directed. NOTE: (i) Chain pully block and clamps etc shall be provided by the department. (ii) Necessary safety pracaution will be responsibility of the contractor.
Dismantling of submersible motor and taking out unserviceable spares and burnt copper winding wire complete. M&L for rewinding of submersible motor with insulated copper winding wire including sleeves as per original company and replacement of worn out parts, including grinding & polishing of rotor sleeves and refixing, testing & transport charges complete of 50 HP all as specified Note :- (i) (Spare shall be paid under item No 34 to 60 as supply. If the same Motor copper winding wire burnt 2nd time in above CA period, Contractor is responsible to paid and rewind the same at their own Cost.
All as per Srl item No. 31 here in before but capacity 30 to 41 HP motor
All as per Srl item No. 31 here in before but capacity 11 HP to 15 HP motor
Bowl bush for 11 to 50 HP motor
Neck ring for 11 to 50 HP motor
Shaft sleeve for 11 to 50 HP motor
Pump shaft for 11 to 50 HP motor
Coupling key for 11 to 50 HP motor
Impeller key for 11 to 50 HP motor
Stud with nuts for 11 to 50 HP motor
Lower housing bush for 11 to 50 HP motor
Upper housing bush 11 to 50 HP Motor
Rotor shaft sleave for 11 to 50 HP Motor
Submersible NRV of Capacity 40-50 HP
Oil seal for 11 to 50 Hp motor
Impellerfor 11 HP to 15 HP motor
Impeller for 25 HP motor
Impellerfor 41 HP motor
Impellerfor 50 HP motor
Coupling for 11 to 15 HP Motor
Coupling for 25 HP Motor
Coupling for 41 HP Motor
Coupling for 50 HP Motor
Thrust bearing for 11 to 15 HP Motor
Thrust bearing for 25 HP Motor
Thrust bearing for 41 HP Motor
Thrust bearing for 50 HP Motor
Supply and fixing in repair MS ERW column pipe screwed 125 mm nominal dia 3 mtr long having wall thickness not less than 7.11 mm electric resistance welded with MS flanged 16 mm thick heavy duty confirming to IS 6392 and with provn of 8 Nos holdes welded all around with pipe for regidness - 4 Nos ribs 10 mm thick incl 2 mm thick rubber sheet and steel nuts and bolts 10 mm long with washer all as specified and directed.
Supply & replacement of Water pressure guage 100 mm dia in size ranging 0 to 25 kg/ sq cm calibration complete with size 3/8"X1/2" and brass cock 1/2" dia complete all as directed.
Supply & replacement of electronic Timer for Star Delta Starter type timing range 3-30 sec all as specified and directed.
Supply & replacement of Single Phase Preventor for 25/35/41 HP submersible pumping set motor all as specified and directed.
Supply & replacement of overload protection relay for FASD starter ranging 28-42/30-35 Amp all as specified and directed.
S&F in repair Digital type ampere meter of size 96x96mm with CT 100/5 Amp, AC, 3 phase, 415 volts complete all as specified.
S&F in repair Digital type voltmeter of size 96x96mm AC, 3P, 415 volts complete all as specified and directed.
Supply, fixing , testing and commissioning submersible cable ,flat, 16 sqmm,3 core, PVC insulated and PVC sheathed with multi stranded, copper conductor, 1100 Volts grade, fixed to submersible motor column pipe, using suitable size of clamps made out of stainless steel flat of size 20 x2 mm with steel nuts, bolts & washer for every column pipe of 3 m length complete all as specified and directed.
All as per Srl item No. 65 here in before but 10 sqmm.
S&F MCCB, 4 pole, 415 Volt, fixed type 160 amp with breaking capacity 16 KA complete all as specified and directed.
S&F MCCB, 3 pole, 415 Volt, fixed type 200 amp with breaking capacity 25KA complete all as specified and directed.
S&F in replacement medium grade GI pipes 25 mm dia of pressure rating 10 Kgf/cm2 fixed complete to walls ceiling or in floors etc complete all as specified and directed
All as per Srl item No. 69 here in before but size 50 mm dia
M&L for cutting existing pipelines and welding flanges, making lead joints on both end with electric arc welding and insertion of tee 80/ 100/150 mm bore flanged ends including necessary packing nuts & bolts complete as specified Note :- CI fittings and lead paid and seperately .
S&F for sluice valve CI class PN 1.6 with stainless steel spindle both end flanged marked of size 200 mm nominal bore including dismantling of existing worn out CI sluice valve of size 200 mm bore complete all as specified and directed.
S&F for sluice valve CI class PN 1.6 with stainless steel spindle both end flanged marked of size 150 mm nominal bore including dismantling of existing worn out CI sluice valve of size 150 mm bore complete all as specified and directed.
S&F for sluice valve CI class PN 1.6 with stainless steel spindle both end flanged marked of size 100 mm nominal bore including dismantling of existing worn out CI sluice valve of size 100 mm bore complete all as specified and directed.
Supply and replacement of CI pipe 150 mm bore flanged ends class LA- ISI marked including necessary nuts bolts and packing etc complete all as specified and directed.
Material and labour brick masonary valve chamber of size 0.90 m x 0.90 m x 0.90 m (internal size) and cover including earth work complete including dismantling of old brick masonary valve chamber all as specified and comprising of the following :- (a) 150 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation. (b) Brick work 230 mm thick built in CM 1:4. (c) 15 mm thick rendering in CM(1:4) internally and externally to exposed surface of brick work including 150 mm below ground level. (d) 100 mm thick coping in PCC 1:2:4 type B1 using 20 mm graded stone aggregate. (e) MS covers made out of 5 mm thick MS plate with double hinges, fixed MS angle iron frame made out of MS angle iron 40 x 40 x5 mm thick including 150 mm long hold fast made out of MS flat iron of size 25 x 4 mm embedded in PCC coping MS covers shall be provided with suitable hand grip and suitable locking arrangement all as directed. (f) All MS surfaces shall, be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
All as per Srl item No. 76 here in before but size (1000x1000x1000)mm.
M & L for painting to pipe of pump house rising mains hydrants, sluice valves, pipe, fittings, NRV, discharge head etc after cleaning, srapping and making the surfaces free from rust of main externally and painting with two coats synthetic enamelled paint in black/ blue/ red including marking/ writing on pipe complete as specified and directed
Supply and fixing in repairs new gunmetal gate valve (ISI marked) and iron wheel head screwed in both ends for GI pipes complete all as specified and directed for the following sizes Make : ZOLOTO/LAKSHMI/MITTAL
(a) 50 mm bore dia of pipe
(b) 40 mm bore dia of pipe
(c) 25 mm bore dia of pipe
(d) 20 mm bore dia of pipe
Taking up old unserviceable water storage tank and S&F rotational moulded polyethylene water storage tank double layer (Cylindrical vertical with closed top) with GI medium grade pipe for inlet, outlet, over flow, checknuts for inlet and outlet, hoisted and fixed in position including suitable PTMT Ball vlave of capacity 1000 Ltrs all as specified
M&L for installation of Digital water level indicator device,with 19mm size digit display including probe unit ,five stage magnetic sensor concealed in SS tube of required length,controlling box including systems incorporated with stage signal,high & low alarm, pump automation as directed capable to one tank from one pump complete all as specified and directed by Engr in Charge. Make : SECO/SATYA SAI or equivalent Technical Specification Prinipal of operations : Negative sequence voltage sensing Systems Voltage & frequency :- 415 +/-20% , 50HZ +/- 5% Contact rating 1 Amp at 415 V AC Trip time delay 3 to 5 seconds Temparature Range : -5 degree C to 50degree C Suitable for - Upto 18 to 25 mtrs OH/UG sump Humidity : Up to 95 % R.H H.V test : 2 KV AC (RMS) 1 min between live parts & body Mode of Operation : Auto/manual
M&L for cleaning of busbar and de carbounising of panel board and replacement of unsv parts including wiring and testing complete all as specified and as directed.
Provn of chemical testing of water at source (i.e Pump House) as per relevent IS codes from IIT/Regional Govt lab/IRTC/other Govt approved lab seperately for each Pump House twice complete for pump house 21, 22, 23, 41,26, 20/35 all as specified and directed. (i) The sample of water shall be taken in presence of Engr-in-Charge for testing. (ii) Test report of water shall be submitted in original and payment of the item shall be made on production of test reports. (iii) 1st test of water at each pump house will be got carried out within one month of acceptance or else a penalty of Rs 500/- per test will be imposed and second test shall be carried out after six months of first test.
S&F in repair Mini motor protection relay for protections of earth fault, thermal overload locked rotor, single phasing ,current unbalance phase sequence reversal, under current incl inbuilt CT's 4A to 22 A complete all as specified and directed. Make : L&T & eqvt
Supply & laying / fixing 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete of size 75 mm all as specified and as directed of size 75 mm.
Supply & laying / fixing 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete all as specified and as directed of size (a) PN-16, 63mm OD (SDR– 7.4) including taking out old rusted GI pipe of 50mm dia.
Supply & laying/fixing 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete all as specified and as directed of size (a) PN-16,110mm OD (SDR– 7.4) including taking out old pvc pipe of 100mm dia.
Supply & laying/fixing 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete all as specified and as directed of size (a) PN-16, 90 mm OD (SDR– 7.4) including taking out old pvc pipe of 100mm dia.
Making connection of PP-R distribution branches with GI main of 80mm dia by providing and fixing PPR fitting tee 50 to 75mm bore including cutting and making fusion joint etc complete all as specified and directed.
Making connection of PP-R distribution branches with GI main of 32mm dia by providing and fixing PPR fitting tee 16 to 40 mm bore including cutting and making fusion joint etc complete all as specified and directed.
Making connection of PP-R distribution branches with GI main of 100mm dia by providing and fixing PPR fitting tee 110 mm bore including cutting and making fusion joint etc complete all as specified and directed.
S&F PPR gate valve (brass insert) of size 32 mm dia including connection and testing complete all as specified and directed including taking out old unserviceable gun metal gate valve 25mm dia.
S&F PPR gate valve (brass insert) of size 63 mm dia including connection and testing complete all as specified and directed including taking out old unserviceable gun metal gate valve 50mm dia Complete all as specified and directed
S&F PPR gate valve (brass insert) of size 110 mm dia including connection and testing complete all as specified and directed including taking out old unserviceable gun metal gate valve 100mm dia Complete all as specified and directed.
M&L for trimming vegetation or small inequalities clearing all grass vegetation, saplings, shrubs, brushwood, roots, and tree of surroundings area including and removing rubbish upto a distance of 50 meters outside the periphery of the area under clearance of water supply installations i.e 21, 22, 23, 37, 20/35, 26 41 including STP 42 , JRC , MH ,80ORs complete all as specified and as directed.
M&L 150mm bore Galvanised Steel Tubes, Medium Grade, laid in trenches, with all fittings and fixtures such as bends, tees, elbows, reducers, unions, plugs & sockets etc., complete all as specified and directed
All as per Srl item No. 96 here in before but size 100 mm bore
All as per Srl item No. 96 here in before but size 80 mm bore
M&L for earthing complete with using GI earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level). Earth plate connected with GI earthing strip (32x6mm) as earthing lead for electric equipment/plants by means of glvanized bolts, nuts and washers atthree places of electrode plate and all as shown in eelectrical plate no 5 of MES schedule Part-1 and testing on compeltion with and including 40 mm dia GI pipe medium grade for protection GI strip (7.5 M to each) and inclduing adequate dust and funnel PCC (1:3:6) type C-1 pit with precast RCC (1:2:4) type B-1 cover 40 mm thick with 6 mm dia MS bars 03 Nos both ways auth lifting hook made out of 6 mm dia MS bars watering arrange with 20 mm dia GI pipe medium grade with funnel and wire mesh, common salt, charcoal fitting and necessary excavation and earth work compelte all as specified and directed.
M&L in repair taking out of repairable Sluice valve Spindle, check nut including lathe work form lathe machine and refixing the same at same location where Sluice valve taken out including testing all as specified and directed
M&L in repair for taking out unserviceable MS/GI Flange of size 50 to 150 mm and fixing of new one MS/GI Flange at same location where MS/GI Flange is taken out including nuts bolts etc all as specified and directed.
Supply and fixing pre-fabricated MS structural steel (IS marked) work consisting of channels / angles /flats/ round bars/MS pipe & other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting for hanging strcture for repair bay all as directed.
M&L in Repair for taking out unserviceable / Rusted CI Tail Piece of size 80mm to 200 mm at same location where CI Tail Piece is taken out all as specified and directed.
Supply and fixing of Pressure Pump of Capacity of 1 HP on the building to increase the pressure of water including all necessary fiittings all as specified and directed.
Supply and fixing Battery 12 Volt 150 AH for DG Set installed at Pump house complete all as specified and directed Make: Exide/Luminous/ Su-kam
Supply and fixing Battery 12 Volt 180 AH for DG Set installed at Pump house complete all as specified and directed Make: Exide / Luminous / Su-kam
Supply and fixing of bollard light of capacity 6-10 Watt including necessary connection all as specified and directed
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3 Core 16 sqmm all as specified and directed .
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3 Core 25 sqmm all as specified and directed .
M&L in repair for sub main wiring with 2 run of FLRS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FR PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in PVC casing/Conduit all as directed.
prabhave traders
VIJAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .