Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAdmitted-Finance PLOT NO 82A SECTOR 5 IMT MANESAR GURGAON HARYANA 122051 | GURUGRAM | HARYANA | 122051 | ₹7.1 L | L1 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical 52 A 4TH FLOOR INDIAN REGISTER OF SHIPPING ADI SHANKARACHARYA MARG POWAI LAKE POWAI MUMBAI MAHARASHTRA | - | - | Not Admitted-Fee/PreQual/Technical Others-As per NIT sr no 7 EMD in the form of DD is not accepted. |
| 3 | Rejected-Technical E 65 MARG TEAM INSTITUTE OF SCIENCE AND TECHNOLOGY PRIVATE L C SCHEME VILLAGE TOWN CHITRANJAN CITY JAIPUR JAIPUR RAJASTHAN 302001 INDIA | JAIPUR | RAJASTHAN | 302001 | - | - | Rejected-Technical Not meeting NIT conditions |
| Sl No | Description | Qty | Unit | VARDAN ENVIROLAB LLP L1 |
|---|---|---|---|---|
| 1.00 | Collection, Freight, handling, analysis and submission of test report through soft as well as hard copies (monthly basis) of HWPK effluents and sewage samples of the following sample points:
1. HWPK Trade Effluent (Mixed Drain after H2S Plant (HWPK) main plant)
For parameters: pH, TSS, BOD (3 days at 27⁰C), COD, Sulphide ( as s2-),
Temperature( in ⁰C ), Phosphate, Free Available Chlorine, Oil and Grease,
Copper (as Cu), Zinc (as Zn), Iron (as Fe), Chromium and Bio assay test.
2. HWPK Domestic Sewage ( Sewage Treatment Plant (S.T.P) at HWP(K)
plant site)
For parameters: pH, TSS, BOD (3 days at 27⁰C), COD, Sulphate (as SO42-) , Oil
and Grease, Nitrate Nitrogen, Chloride (as Cl-),Total Residual Chlorine,
Ammonical Nitrogen (as N) & Temperature.
.
3. STP Water (Sewage Treatment Plant (S.T.P) at HWP(K) colony)
For Parameters: pH, TSS, BOD (3 days at 27⁰C), COD, Oil and Grease, Sulphide
(as s2-), Chloride (as Cl-) and Total Residual Chlorine
All the above mentioned work (monthly) treated as one lot. | 24 | Lot | 11,092 ₹2,66,208 Lowest |
| 2.00 | Collection, Freight, handling, analysis and submission of test report through soft as well as hard copies (Twice in a month) of HWPK ambient air monitoring samples of the following sample points:
1.Ambient Air Monitoring and Testing (Sample Point No.1:Watch Tower Near H2S Generation Plant) for the following parameters
RPM, SPM, SO2, NOx, CO and H2S
2. Ambient Air Monitoring and Testing (Sample Point No.2:Watch Tower Near Steam Generation Plant) for the following parameters
RPM, SPM, SO2, NOx, CO and H2S.
All the above mentioned work (twice in a month) treated as one lot | 24 | Lot | 16,992 ₹4,07,808 Lowest |
| 3.00 | Collection, Freight, handling, analysis and submission of test report through soft as well as hard copy (Once in a three months) of HWPK DG set stack emission sample monitoring for the following Parameters:
SPM, SOx and NOx.
All the above mentioned work (once in three months) treated as one lot | 8 | Lot | 4,130 ₹33,040 Lowest |
Tender Value
₹9.3 L
EMD Value
₹18,560
Closing Date
1 Oct 2025, 2:30 pmClosed
General Manager
GM Office, HWPK
Contract for Collection and analysis of liquid effluent samples,ambient air samples and DG set stack emission sample for two years.
2025_HWB_877143_1
HWPK/PCAL/2025/732
Open Tender
Job Works
Item Rate
730 days
HWPK, Anushakti
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹18,560
GM Office, HWPK
5 Dec 2025
15 Sept 2025
10 Oct 2025
15 Sept 2025
1 Oct 2025
20 Sept 2025
18 Sept 2025 - 18 Sept 2025
18 Sept 2025
Amount
Collection, Freight, handling, analysis and submission of test report through soft as well as hard copies (monthly basis) of HWPK effluents and sewage samples of the following sample points: 1. HWPK Trade Effluent (Mixed Drain after H2S Plant (HWPK) main plant) For parameters: pH, TSS, BOD (3 days at 27⁰C), COD, Sulphide ( as s2-), Temperature( in ⁰C ), Phosphate, Free Available Chlorine, Oil and Grease, Copper (as Cu), Zinc (as Zn), Iron (as Fe), Chromium and Bio assay test. 2. HWPK Domestic Sewage ( Sewage Treatment Plant (S.T.P) at HWP(K) plant site) For parameters: pH, TSS, BOD (3 days at 27⁰C), COD, Sulphate (as SO42-) , Oil and Grease, Nitrate Nitrogen, Chloride (as Cl-),Total Residual Chlorine, Ammonical Nitrogen (as N) & Temperature. . 3. STP Water (Sewage Treatment Plant (S.T.P) at HWP(K) colony) For Parameters: pH, TSS, BOD (3 days at 27⁰C), COD, Oil and Grease, Sulphide (as s2-), Chloride (as Cl-) and Total Residual Chlorine All the above mentioned work (monthly) treated as one lot.
Collection, Freight, handling, analysis and submission of test report through soft as well as hard copies (Twice in a month) of HWPK ambient air monitoring samples of the following sample points: 1.Ambient Air Monitoring and Testing (Sample Point No.1:Watch Tower Near H2S Generation Plant) for the following parameters RPM, SPM, SO2, NOx, CO and H2S 2. Ambient Air Monitoring and Testing (Sample Point No.2:Watch Tower Near Steam Generation Plant) for the following parameters RPM, SPM, SO2, NOx, CO and H2S. All the above mentioned work (twice in a month) treated as one lot
Collection, Freight, handling, analysis and submission of test report through soft as well as hard copy (Once in a three months) of HWPK DG set stack emission sample monitoring for the following Parameters: SPM, SOx and NOx. All the above mentioned work (once in three months) treated as one lot
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .