| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L1 | Accepted-AOC Accepted being lowest and reasonable one. | |
| 2 | L2₹33.6 L+₹1.4 L (4.24%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹34.7 L+₹2.5 L (7.65%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
3 Mar 2025, 6:00 pmClosed
SHRI ABHINANDAN KUMAR MISHRA, EE, IDSE
GE (SOUTH) AMBALA CANTT
REPAIR MAINT OF INTERNAL ELECTRIFICATION AND ALLIED ESSENTIAL SERVICES INCLUDING CEILING FAN EXHAUST FANS WALL MOUNTED FANS AND LIGHTING PROTECTION SYSTEM OTM ACCN OF JAWAHAR LAL NEHRU ROAD IN C1 SECTOR AND ADJOINING AREA UNDER GE SOUTH AMBALA CANTT
2025_MES_696269_1
GE(SOUTH)/AMB-55/2024-2025
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE (SOUTH) AMBALA CANTT
₹98,000
Yes
22 May 2025
3 Feb 2025
5 Mar 2025
3 Feb 2025
3 Mar 2025
18 Feb 2025
3 Feb 2025 - 17 Feb 2025
Amount
Material and labour for taking down ceiling fan/ Exhaust fan / wall mounted fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed.
Supply and fixing in repair fan condencer 2.5/ 4 MFD, 240 volts suitable capacity for ceiling/ exhaust Fan all as specified and directed.
Supply and fixing in repair ball bearing of suitable size and capacity for ceiling/ Exhaust fan all as specified and directed.
Supply and fixing in repair hanging assymbly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed.
Supply and fixing in repair PCB unit of suitable size for BLDC Ceiling fan of 1200mm sweep as per make of ceiling fan, single phase, 240 V complete all as specified and directed.
Material and labour for hanging only ceiling fan/ Exhaust fan / wall mounted fan after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades all as specified and directed.
Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 1200/ 1400 mm sweep complete all as specified and directed. NOTE for item No 1 to 7 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
Material and labour in repair for making hole in wall for fixing of exhaust fan of relevent size ,round in shape and making good disturbed surfaces matching with existing complete all as specified and as directed .
Material and labour for rewinding of Exhaust fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 230 to 450 mm sweep complete all as specified and directed. NOTE for item No 2,3 and 8 to 11 : -(i) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate. (ii) The cost of shifting the fan from MES store yard to contractors workshop and back shall be included in the item. (iii) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair, in failing so, the amount @ Rs. 20/- per fan per day shall be deducted from the contractor due till the returning of fan duly tested.
Supply and fixing in repair motor of wall mounted fan including fixing mountings and accessories of wall fan of 230 to 450 mm sweep complete all as specified and directed.
Supply and fixing heavy duty PVC body wall mouting fan 400 mm sweep with corrosion resistant PVC body minimum noise, operation and maintance free design totally enclosed highly efficient heavy duty motor with pressure die cast aluminum rotor mounted on two ball bearings aerody namically contoured blades rigid frame ,1400 RPM PVC blades and testing complete all as specified and as directed by Engineer in Charge.
Supply and fixing of plastic body exhaust fan, AC singal phase, 240 volts of size 250 mm sweep with heavy duty, plastic body with louvers connecting up including provision of fixing clamp, nut bolts and cable from ceiling rose or connector to fan,including taking down old unserviceable pastic body exhaust fan complete all as specified and directed. Note: making holes of suitable size in wall including surface finishing as per existing pattern to be included in the unit rate quoted.
Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etc and checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessary adjustment and refixing the repaired geyser in position, connecting to existing electric & water connections and testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate. (b) Examine any water leakage from geyser/storage tank. (c) Carry out operation of all stop cocks, pressure reducing valves, etc. to ensure free movement of the working parts. (d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items. (g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ.
Description all as per Item No 13 above but for gayser of cap 35/ 50 ltrs capacity.
Supply only heating element of capacity 2 KW of geysers of any make ISI marked complete all as specified and directed.
Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity complete all as specified and directed.
Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed.
Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed.
Supply only temperature resistent SS braided pipe suitable to sustaine pressure up to 8 bar not less than 60 Cm long suitable for out going / Hot water connections of Geyser with washer etc. complete as an directed.
Supply only Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement complete all as specified and directed.
Supply only Indicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed.
Supply only Geyser storage inner tank made out of stainless steel sheet suitable for 25 ltrs capacity complete all as specified and directed.
Supply only geyser storage inner tank made out of stainless steel sheet suitable for 50 ltrs capacity complete all as specified and directed.
Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed.
Supply and fixing in repair copper cable PVC insulated and PVC sheathed flexible size 2.5Sqmm 3 core complete all as specified and directed. (Cable shall be in suitable length as per site requirement).
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic,medium grade PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 27.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 27.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 27.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH PVC insulated and unsheathed stranded cable drawn through in existing non metallic/mettalic medium grade concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 31.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 31.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 31.00 above but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Supply and fix modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fix modular switches, one way, 16Amps, one module, 230 volt , AC supply, complete all as specified and directed.
Supply and fix modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fix modular socket outlet 6/16 amps,3 pin, 2 module, complete all as specified and directed.
Supply and fix fan regulator step type one module / 2 module, 100w 230 Volts, 50 Hz, AC complete all as specified and directed.
Supply and fix modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fix modular blanking plate 1 module complete all as specified and directed.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with FRLSH )accessories, concealed on wall/ceiling and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately . 2. All chases will be cut by chase cutter only.
Description all as per item No 42.00 here in before but for socket out let point 5 Amps on same board,complete all as specified and directed.
Description all as per item No 42.00 here in before but for socket out let point 5 Amps on independent board,complete all as specified and directed.
Description all as per item No 42.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed.
Supply and fix switch piano 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fix switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and directed.
Supply and fix socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed.
Supply and fix socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified.
Supply and fix fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed.
Supply and fix bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fix door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
Supply and fix ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fix sheet metal enclosure SP with two pin and earth plug and socket inclduing metal clad top with one single pole MCB 32 Amp complete all as specified and directed.
Supply and fixing of LED light fitting 1x20W (lumen efficacy of >100 lm/W) , 220V, AC with aluminium housing with batten type with driver , holder including 20W LED tube light for connecting up with three core flexiable copper conductor cable of suitablae size from celing rose to connector complete all as specifid and directed
Supply and fix channel for fixing of LED tube rod of CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. ( Tube rod shall be measured and paid for separately ). Note: - Channel must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact
Supply and fix in repair 18 W/ 20W LED tube rod (lumen efficacy of >100 lm/W), environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. Note: - Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings .
Supply and fix batten type with surface mounted LED tube light fitting with high efficient diffuser mirror light,aluminium housing in CRCA body suitable and including 10 watt LED tube rod high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Disconnecting and taking down old existing wall fitting of any description and in any position and supply and fixing aesthetically designed Bowl type (STYLO) wall bracket light in B22 holder with 7 watt LED lamp warm white & clear diffuser including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Disconnecting and taking down old existing recess/surface mounting ceiling light fitting of any description and in any position and supply and fixing surface/ recess mounting LED slim square panel /round down light not less then 12 W LED with high efficient LEDs glare free opal diffuser madeup of PDC AL with IP 20 Protection including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed. Note: Recess/Surface mounting must get approved from engr-in-charge as per site requirement.
Supply and fix bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description complete all as specified and directed.
Supply and fixing LED Decorative,wall mounting light, brushed nickel finish fixture with Opal Glass diffuser with 2 x 9 W LED Lamp/ lamp B22 base. including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing of Inverter LED tube light fitting 1x20 Watt with minimum 03 hours battery back up batten with diffuser and including 20 Watt LED hight efficient, AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Material and labour in repair for point wiring with FRLSH PVC insulated and unsheathed cable 4 Sqmm (Nominal area) stranded copper conductor single core including ISI marked 20 mm dia medium grade PVC conduit for point wiring, concealed in wall / metal flush boxes including white cover plates and frame for mounting switch/socket (modular) with all accessories including 4 Sqmm PVC insulated and unsheathed stranded copper wire conductor cable to common earth and connecting to earth dolly for one 20 Amps AC switch socket out let point on an independent board including colour coding of cable shall be Phase- Red, Neutral- Black and Earth- Green complete all as specified and directed by Engr-in-charge. Notes: Cost of making good disturbed surfaces matching with existing shall be deemed to be included in the quoted rate.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 6 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE:-3 run of 6.0 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE:- 3 run of 4.0 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) Taking out old unserviceable earthing complete all as specified and directed. NOTE : - The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to be including in quoted rates.
Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type ,125AMPS ,25 KA as incomer and MCB s as out going complete with making suitable size of MS cabinet 1.2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed.
All as per Item No 68 here in before but VTPN DB alongwith MCCB 4 pole,100AMPS 16 KA as incomer and MCBs as out going complete all as specified and directed.
Supply and fixing in repair SPN distibution board 4 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and directed.
Supply and fixing in repair SPN distibution board 8 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and directed.
Supply and fixing in repair SPN distibution board 12 way, double door, IP 43, as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles /gland/gaskets complete all as specified and directed.
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, ISI complete all as specified and directed.
Supply and fixing in repair MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, ISI marked complete all as specified and directed.
Supply and fixing in repair MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series complete all as specified and directed.
Supply and fixing in repair MCCB Sheet metal encloser of suitable size with and including MCCB 4 pole thermal release type ,125AMPS ,25 KA, including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed.
Supply and fix in repair MCCB four pole 415 volts, 100 Amps,16KA, 50 Hz thermal release adjustable type complete all as specified and as directed.
Supply and fix in repair MCCB four pole 415 volts, 125 Amps,25KA, 50 Hz, thermal release adjustable type complete all as specified and as directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 06 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as directed and specified.
All as per Item No 75 above but one twin core cable circulat of size 10 Sqmm complete all as directed and specified.
Supply and fixing LED Decorative, Picture light, brushed nickel finish fixture with Opal Glass diffuser suitable with 6 W LED, including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fix in repair post top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing of LED based Bollard light not less than 15 Watt warm white with powder coated PDC aluminium body with glare free PMMA Diffuser, IP 65 of height not less than 1000mm and dia not less than 65mm including necessary excavation & PCC block of size 250mmx250mmx250mm etc complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fix bracket for security light made up of 25/40/50mm dia suitable for security light, 0.6 metre long GI pipe, light grade, 120 degree bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fix LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fix LED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fix inverter LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP66 protection, better optics for uniform distribution with multiplte LEDs having optical grade polycarbonate lens with 3 to 4 hours battery back up, auto on off all accessories internally pre wired and including connecting up with Two core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fixing LED luminaire 300 mm x 300 mm,18 watt, 220 V AC recessed surface mounted as per the site requirement type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing recess/ surface mounted LED flat panel 2' x 2' with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided with including LED 36 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing surface mounted LED flat panel 1' x 4' with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided with including LED 36 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Material and labour for attending day to day complaints of E/M nature by means of checking unserviceable Electrical fitting and fixture and emergent fault rectification in elctrical circuit incl no light , earth leakage, short cicuit, neutral break mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minor repairs etc as required to make system in order / functional by replacing, copper cable , copper thimbles, glands, earthing wire complete all as specified and as directed as required at site by Engineer-in-Charge. NOTE : - (a) Items reqd for replacement such as switchs, sockets for power/light/ fan/ bell/geyser points including complete will be measured and paid under respective items of BoQ. (b) Contractor rep/supervisor will report to MES Service Centre alongwith qualified/Experianced electrician and helper to collect dockets between 0900 hrs to 1000 hrs on all working days for rectification of complaints and resubmit the dockets after completion of each job of each job on the same day. If contractor is failed to submit the docket within 48 hours after issuing of dockets , the contractor i liable to pay the penalty i.e. 20.00 per docket per day till the re-submission of docket. (c) Contractor will attend emergent nature of work i.e. no light, short circuit after working hours/holiday as when ordered. The rate of the is deemed to be included in above quoted rates.
Supply only switch piano 5 Amps, flush type, single pole, one way, 230 volt, AC supply, ISI Marked, complete all as specified and as directed.
Supply only switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, complete all as specified and as directed.
Supply only socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as specified and as directed.
Supply only socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified and as directed.
Supply only fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and as directed.
Supply only bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, complete all as specified and as directed.
Supply only door bell electric ,ding dong /musical| type, single phase 230 volts, complete all as specified and as directed.
Supply only ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed.
Supply only switch, single pole two way 6 Amps, 230 volts AC circuit complete all as specified and as directed.
Supply only lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed.
Supply only switch modular 6 amps, one way single module with and including necessary frame as per existing make and type complete all as specified and as directed.
Supply only switch modular 16 amps, one way single module with and including necessary frame as per existing make and type complete all as specified and as directed.
Supply only socket modular 6 amps, 5 pin combined universal socket 2 module with and including necessary frame as per existing make and type complete all as specified and as directed.
Supply only socket modular 6/16 amps, 2 in 1, combined universal socket 2 module with and including necessary frame as per existing make and type complete all as specified and as directed.
Supply only fan regulator step type one module / 2 module, 120W, 230 Volts, 50 Hz, AC complete with and including necessary frame as per existing make and type complete all as specified and as directed.
Supply only bell push modular with and including necessary frame as per existing make and type complete all as specified and as directed.
Supply only PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed.
Supply only PVC insulated, unsheathed cable 1.5 Sqmm single core 1100 volt grade with multi stranded copper conductor complete all as specified and as directed.
Supply only Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, ISI marked complete all as specified and as directed.
Supply only MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, ISI marked complete all as specified and as directed.
Supply only MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, 'B' Series complete all as specified and as directed.
Supply and fixing in repair of unique design 4 Module cover Plates of Flame Retardant Material Compatible with Standard Size of Metal Flush & Plastic Surface Boxes as per existing make and type complete all as specified and as directed.
Supply and fixing in repair of unique design 6 Module cover Plates of Flame Retardant Material Compatible with Standard Size of Metal Flush & Plastic Surface Boxes as per existing make and type complete all as specified and as directed.
Supply and fixing in repair of unique design 8 Module cover Plates of Flame Retardant Material Compatible with Standard Size of Metal Flush & Plastic Surface Boxes as per existing make and type complete all as specified and as directed.
Supply and fixing in repair of 4 Module metal flush boxes made of G.I Sheet not less then 1.2mm thick with provision of earth terminal complete all as specified and as directed.
Supply and fixing in repair of 6 Module metal flush boxes made of G.I Sheet not less then 1.2mm thick with provision of earth terminal complete all as specified and as directed.
Supply and fixing in repair of 8 Module metal flush boxes made of G.I Sheet not less then 1.2mm thick with provision of earth terminal complete all as specified and as directed.
Supply and fixing of unique design 3 Module cover Plates with 3 Module Plastic surface boxes made of Flame Retardant Material complete all as specified and as directed.
Supply and fixing LED flood light highly efficient integral type, made of pressure die cast aluminium housing with 10 KV SD lens & toughened glass IP 66, energy efficient provided with including LED 50 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing LED flood light highly efficient integral type, made of pressure die cast aluminium housing with 10 KV SD lens & toughened glass IP 66, energy efficient provided with including LED 90 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing of LED lamp 10 watt B-22 base complete including taking down old existing lamp any type complete all as specified and directed.
Supply and fixing of LED based Bollard light 10 watt with aluminium pipe housing with glare free PMMA Diffuser, IP 65 of height not less than 600mm including necessary excavation & PCC block of size 250mmx250mmx250mm etc complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation of poles,cable laying etc, including forming bottom surface to required level and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in soil/loose soil including spreading, leveling,watering & well ramming in layers not .exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing of surplus spoil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches and punning down complete all as specified and directed by Engineer-in-Charge.
Material and labour cover to underground cable with one layer of bricks using sub class 'B' bricks laid flat acorss the cable complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed twin core 10sqmm 4 core nominal cross section in service connections all as directed
Material and labour as in repair for test point terminal block made of gun metal or phosphorus bronze, size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. Head screws moundted on PVC insulator complete all as specified and directed by Engr-in-Charge.
Supply and fixing as in repair aluminium strip 25 X 3 mm with saddle and fixing screw etc for roof conductor and down conductors above ground.
Supply and fixing as in repair of Air termination, single pointed, aluminium rod 12mm dia and 300mm long complete all as specified and directed by EIC.
Material and labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using 32x6mm GI strip by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) Taking out old unserviceable earthing complete all as specified and directed. NOTE : - The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to be including in quoted rates.
Material and labour for taking down existing light fitting of any type alongwith GI pipe/ pole of any dia upto 3 mtr height and supply and fixing of MS pipe (Hot dipped Galvanized) decorative pole in two sections i.e Top pipe not less than 75 mm outside dia and Bottom pipe not less than 110mm outside dia , including aluminium embellishment in between top & bottom pipe thickness of pipe not less than 3 mm with base plate 250 x 250 x 12mm thick having 14mm dia hole for fixing of foundation 'J' bolts of size 12mm dia x 450 mm "J" including 115 x 200 mm long utility window in pole, fixing of suitable size nuts/bolts and washers, including decorative pole base cover, enhancing the apperance of the pole Tripple layer metallic PU paint (Etching, Epoxy & PU) suitable for and alongwith 35 Watt Warm white LED post top lantern IP 65 environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs clear cover offers bright illumination including all fixing accessoreis including necessary excavation, removal and PCC 1:3:6 work as directed etc complete all as specified and directed. Note : (i) Quoted rates shall be inclusive of excavation, taking down existing pole, all fixing acessories & PCC 1:3:6 for fixing of pole & post top lantern. (ii) Drawing of pole must get approved before installation.. (iii) MS pipe of pole (Top & Bottom) should be ISI marked as per latest standard.
Supply and fixing 120Watt High bay light highly efficient (lumen efficacy of >150 lm/W) integral type, made of pressure die cast aluminium housing,High quality PC lens with optional narrow & wide beam angles for uniform distribution,tempered protective toughened glassthermal shock and impact resistant, buit In electronic driver with APFC, lower THD, Open Circuit Protection, with Built In SPD per IS 15885/Part-2/Sec 13 including provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and suspended wire if rquired at site complete including disconnecting and taking down existing light fitting complete all as specified and directed.
Supply and fixing recess/ surface mounted LED flat panel 2' x 4' with high efficient LEDs and glare free full decorative light fitting, 72 watt, energy efficient provided with including LED 72 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and installing,testing Automatic Transfer Switch 4-Pole 100A, Rated voltage 415V,50 Hz, enable Automatic transfer from one source to other with adjustable time delay,Indicateing status of the source, with UV/OV, Phase Sequence, Single Phasing,Protection, with SS Encloser confirming IS/IEC60947-6-1, complete all as specified and directed.
Supply and fixing 7 Watt wall washer light, Crafted from Aluminum Die Cast with Four-Directional Beam. Its integrated LED ensures long-lasting and energy-efficient with IP65 Protected complete all as specified and directed.
NOTE:- Amount of credit of Rs. 1,30,334.00 for retrieved materials is mentioned in Schedule of Credit Page No 19 & 20 of tender documents in pdf form which will be deducted offline while acceptance of tender.
M/S HARCHARAN SINGH (BID ID -3246475)
Goyal Engineers (BID ID -3247802)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .