Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹15.3 L
EMD Value
₹30,547
Closing Date
23 Oct 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Constr/Electrification of Guest House B.W.O Providing Electrification Facility to Guest House at JKPSC Complex at Solina Srinagar
2025_PWDJK_291385_1
NIT No.131/2025-26 Dt/09/10/2025
Open Tender
Electrical Works
Percentage
Solina Srinagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹30,547
Yes
9 Oct 2025
9 Oct 2025
24 Oct 2025
9 Oct 2025
23 Oct 2025
9 Oct 2025
of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trilux /Wipro make /LT/ eq. make as directed by EIC sample to be approved before installation.
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havells Lifeguard/Polycab Green/ Fenolex/ Salzer/eq. standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit.( Excluding the cost of conduit)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( L&T/Legrand /SSK /schneider/Siemens make ( Antibacterial Series).)
Wiring for lighting circuits/ 6- 10 amp power plugwith 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havells Lifeguard/Polycab Green/ Fenolex/ Salzer/eq. standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit ( Excluding the cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( L&T/Legrand /SSK /schneider/Siemens make ( Antibacterial Series).)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. ( L&T/Legrand /SSK /schneider/Siemens make ( Antibacterial Series).)
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, "C" curve including connections, painting etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ( Havells Lifeguard/Polycab Green/ Fenolex/ Salzer/eq. standard make as desired by engineer incharge ), single core cable in surface/ recessed medium class PVC conduit as required.( Excluding the cost of conduit)
(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(b ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire
( c )2 X 10 sq. mm + 1 X 6 sq. mm earth wire
(d) 2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster, wall putty , paint, complete
Supply and fixing of wooden channel/ casing made from Kashmiri Budloo wood having2.6"- 3" width suitable for carrying out wiring for different circuits.
Supply installation testing and commissioning of backlit, 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 110 lm/W with Pressure Die cast Aluminium housing, Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date
Supply installation testing and commissioning of backlit, 12-15W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 110 lm/W with Pressure Die cast Aluminium housing, Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trilux /Wipro make /LT/eq. make as directed by EIC sample to be approved before installation..
Supply installation testing and commissioning of 36 W + ( 2x2) LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium/ CRCA body, Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/TRulux /Wipro make / sample to be approved before installation..
Supply installation and testing and commissioning of decorative fancy type two way wall bracket along with suitable LED lamp. Sample to be approved before installation. .(Philips/ jaguar/ LT/ Eq. standard make as directed by the engineer incharge. )
Supply installation and testing and commissioning of decorative fancy type one way bed light along with suitable LED lamp. Sample to be approved before installation. .(Philips/ jaguar/ LT/ Eq. standard make as directed by the engineer incharge. )
S/F testing and comm. Of 20 W + 4 ft. wall mounted LED batten with powdered coated aluminum housing & integrated electronic driver with minimum system lumen efficacy of 100 lm/W with THD<10%.( commercial series) CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Trulux /Wipro make / sample to be approved before installation..
Supply installation testing and comm. of flood light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton make. the job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job.
Supply installation testing and comm. Of 200-250mm sweep exhaust fan Shutter type/ steel body of havell /USHA/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections.
Supply, Installation, Testing and Commissioning of decorative fancy type 1200 mm sweep, ceiling fan ( sample to be approved before installation) ( USHA/havell /Bajaj/Crompton/equivalent make as directed by engineer incharge,) class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. the job includes the steel rod of suitable size and length to be installed at site.
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /SSK NV/schneider Zencelo /Havell Coral make.
SITC of wall fan 400 mm sweep as approved by EIC ,240v,50 Hz complete , etc. as required. Make(Usha /Orient/Crompton/ Havells
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board,( legrand/ Scheinider/Hager make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
8 way, Double door ( 18+4)
Supplying and fixing of following rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. legrand / Schinider/ L&T ./equivalent make as directed by engineer incharge.
a) 6-32 Amp SP MCB
b) 40-63amp DP MCB
Dismentalling of burntout wires/ fixtures /unserviceable electric items by way of engaging skilled labour and its safe storage. ( complete job)
Supply installation testing and commissioning of energy efficient 1.5 Ton inverter type split Air Conditioning system ( Hot and cold) suitable for operation on AC supply single phase 220 V . The indoor unit fitted on wall by employing suitable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning.(Hitachi/Panasonic/DAIKIN/Toshiba/ Eq. standard make as directed by the engineer incharge. )
Supply, Installation, testing and commissioning of relay type voltage stabilizer suitable for 2 Ton AC operating from input voltage 90-260 Volts thereby producing output voltage of 230 volts +/- 3 % ( Vguard/ Livgaurd/LG make)
supply, laying underground, testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size.
c)50 sq.mm 3.5 core
Supply installation testing and comm.of invertor battery 150 AH/12 V Exide invatubular/ eq. standard make as directed by engineer incharge.
Supply installation testing and commissioning of Sine Wave Inverter, Capacity 3.5 KVA, ,Supporting 4 no. battery,24 Month Warranty Safe for sensitive appliances with Sine wave out-put, Auto over-load handling capacity Installation and maintenance friendly Offers high quality and reliable power back-up solution for office and homes ,MCB for protection from Input mains,Bypass switch for supplying output directly from grid in case of Home UPS fault.Noiseless Operations with the help of low harmonic distortion, Intuitive Display to easily understand status of mains availability, battery status, etc.Comprehensive protection against short-circuit, reverse polarity, battery over-charge, deep-discharge etc.Adaptive Battery charging control system technology (ABCC) ensures faster battery charging and enhances battery life by around 70%.Supports a wide battery range, i.e. Flat Plate, Tubular & VRLA (SMF).praffered make Luminous/ Microtek/Exide make. The job also includes the angle iron structure suitale to hold 4 No. Battery and the inverter. ( Complete job)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havells Lifeguard/Polycab Green/ Fenolex/ Salzer/eq. standard make as desired by engineer incharge ) single core cable in surface / recessed medium class PVC conduit,( Excluding the cost of conduit) with modular switch ( L&T/Legrand /SSK /schneider/Siemens make/eq. make as directed by EIC ( Antibacterial Series).), modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
Normal INCOMING:
a)160A 4P MCCB 25 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB make.
b) 4 No. of Aluminium Bus Bar of 300 Amp.
c)Digital meters and phase indicators -1 set.
d) onload Change over switch 100 Amp for generator.Front operated.
e) 4 No. of Aluminium Bus Bar of 200 Amp.
c)Digital meters and phase indicators -1 set.
OUTGOING:
c) 40-63amp DP MCB
c) space for 12 way MCB's
Supplying,Installation,Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G. and acetylene, and electrical. Cease fire/ Equivalent standard make as desired by engineer incharge
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.93 MB
BOQ_937125.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .