Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.1 L+₹74,033 (7.92%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L2 | Rejected-Finance L2 | |
| 3 | L3₹11.2 L+₹1.8 L (19.5%)Rejected-Finance 94 PHEARS LANE 1ST FLOOR KOL 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance L3 | |
| 4 | L4₹11.2 L+₹1.8 L (19.5%)Rejected-Finance 14 BEPIN BEHARI GANGUALY STREET KOLKATA 700 012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹23,400
Closing Date
10 Oct 2020, 2:30 pmClosed
EXECUTIVE ENGINEER
O/o The EE_KNED, PWDte, P-5, CIT Road, 2nd Floor, Moulali,Kolkata-700 014.
Vertical Extension of the office building up to 8th floor in the compound of Baguihati Complex, VIP Road, Kolkata---- SITC of Fire detection and Alarm System.
2020_WBPWD_291949_3
WBPWD/EE/KNED/NIT-07 of 2020-21
Open Tender
FIRE FIGHTING ORG
Item Rate
30 days
Baguihati Mechanical Complex
Please refer Tender documents.
4 documents required · 4 mandatory
₹23,400
8 Mar 2021
23 Sept 2020
12 Oct 2020
26 Sept 2020
10 Oct 2020
26 Sept 2020
Amount
Supply, installation, testing & commissioning of EN Standard, VDS/LPCB approved Addressable Optical Smoke cum Heat type Multi-Sensor Detector with inbuilt / equal number of additional Isolator for each detector and integral LED status indicator with 360 degree viewing angle. Detector shall communicate for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air currents. Detector should have unique address for communication and assigned through panel with Mounting Base as required. (Approval standards: VdS, EN54; Approved Make: Esser by Honeywell / Securiton / Autronica by UTC/ Siemens)
Supply, installation, testing & commissioning of EN Standard, VDS/LPCB approved Intelligent addressable manual call point with inbuilt / equal number of additional Isolator for each manual call point suitable for flush or surface mounting, call point shall include test key feature without removing the glass. (Make: Esser by Honeywell / Securiton / Autronica by UTC/ Siemens)
Supply, installation, testing & commissioning of EN Standard, VDS/LPCB approved Intelligent addressable Input & output Module with inbuilt /equal number of additional Isolator for each providing automatic facility for On-Off AHU/Lift etc. during Emergency. (Approval standards: VdS, EN54; Make: Esser by Honeywell / Securiton / Autronica by UTC/ Siemens)
Supply, installation, testing & commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Panel capable of supporting minimum 4 loops expandable upto 6 loops and minimum 125 detectors per loop ,each loop should be connected to a dedicated loopcard (even if a loopcard supports multiple loop, the panel should be provided with minimum 4 nos loopcards and should have provision for accomodating total 6 nos loopcards) and having power supply unit (230 ± 5% V, 50 Hz), network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 1000 events history log in the non-volatile memory (EPROM). Addressability of the Intelligent Panel shall be soft addressed so as to consume minimum time of addressing the system with Detectors and Devices. The Intelligent panel shall be able to give pin point location of all fire/fault conditions. All the multi criteria Detectors as applicable for various areas based on application and design considerations shall be fitted on Loop along with Loop powered Alarm Devices; MCPs and Input /output Modules. The panel shall have in built rectifier, Loop cards, and provision for external, LCD unit to indicate Fire/Fault Signal with address. 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. Such sub-panel should connect with existing Main fire alarm panel. (Approval standards:VdS, EN54; Make: Esser by Honeywell / Securiton / Autronica by UTC/ Siemens)
Supply, Installation, Testing & Commissioning of Response Indicator, with all other accessories. (Approved Make: Siemens /Securiton/Autronica)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop). (Make. Finolex /Hemflex / MEM)
Supply & Laying of 20 mm NB PVC rigid conduit pipe on the surface of the wall. (Make: Precisson-Medium/Presto-plast/Polycab)
GLYPTIC
NILEX FIRE PROTECTION SYSTEMS
ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .