Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | As L1₹7.4 LAccepted-AOC 210 A RASHBEHARI AVENUE KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | As L1 | Accepted-AOC L1 | |
| 2 | As L2Rejected-Finance 2 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | As L2 | Rejected-Finance As L2 | |
| 3 | As L3Rejected-Finance PM 3 6 TEGHORIA MONDAL PARA 3RD LANE KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | As L3 | Rejected-Finance As L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Insufficient valid documents | |
| 5 | As L4Rejected-Finance 125 SHIVAJI NAGAR SAVARKUNDLA SAVARKUNDLA GUJARAT 364515 | AMRELI | GUJARAT | 364515 | As L4 | Rejected-Finance As L4 |
Tender Value
₹12.8 L
EMD Value
₹25,543
Closing Date
17 Aug 2018, 9:00 amClosed
Executive Engineer PWD BDN ELEC DIVN
Room no 1081st fl purta bhawan salt lake kolkata
Upgradation and remodeling of a portion of Multipurpose hall as large auditorium and mini auditorium at 1st Floor of Gplus7 new hostel building of ATI, Salt Lake EI works
2018_WBPWD_183967_1
WBPWD/EE/BED/34/e-IT of 2018_19
Open Tender
ELECTRICAL WORKS M/R
Item Rate
15 days
ATI
Please refer Tender documents.
4 documents required · 4 mandatory
₹25,543
Yes
29 Sept 2021
30 Jul 2018
20 Aug 2018
3 Aug 2018
17 Aug 2018
3 Aug 2018
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar with holes fixed on bakelite/hard rubber insulation over the welded chairs incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] a) Avg. run- 8 mtr.
S&F of suspended prismatic decobay LED light fittings with 1no 11/9 W LED lamp (Make-Philips.. Cat no DN193B or equivalent of wipro/CG) as per direction of EIC.
S and L of 3X1.5 sqmm PVC insulated FR wire as per GS
S and L of 2X2.5 +1X1.5 sqmm sqmm PVC insulated FR wire as per GS
S and L of 2 X 4 +1X2.5 sqmm sqmm PVC insulated FR wire as per GS
Dismantling the existing switch board and refixing the same in new position as per direction of EIC
Supply and fixing of AC starter( North -West) in suitable modular box and 16A power plug with swich in the suitable modular box separately as per instruction of EIC
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch and 5A modular plug with switch on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch and 6A modular plug with switch Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top and 03 nos 6A plug and switch GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(computer board) [N.B. (1) The Agency must procure the materials from the Manufacture/OEM or from their authorized. Sales channel so that the standard warranty/support of the Manufacture/OEM becomes applicable to the products to be delivered and installed by them, (2) Documents that authenticates such procurement from the Manufacture/OEM or from their authorized sales channel and standard warranty/support should be sent from the e-mail of the Manufacture/OEM/authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill (3) If any refurbished material is supplied and installed, penal action will be taken as per exixting rules]
L.W.C. must be quoted manually @1% on the total quoted value else the total quoted rate shall be treated incl. LWC as per rule. N.B. Rate should be quoted inclusive of GST.
MAHESWAR ELECTRICAL INDUSTRIES
PHINIX
S. N. ENTERPRISE
STANDARD BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .