NAME OF WORK :-Renovation to E.I.,Switchgear and Compound Light in Prant Office Kutiyana, Dist. Porbandar
QTY. UNIT RATE TOTAL
Replacing old & U/s by new Point wiring for Tissino / Modular
secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires, in below type of pipe to be erected
complete with earth continuity and necessary connection with primary
1 light with accessories erected on Metal / PVC / wooden box covered 3.00 pt 132.31
with 3 mm thick PC(Polycarbonate) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder / ceiling rose /
H.D.Connector as directed. (a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete
Replacing old & U/s by new Point wiring for Light / Bell with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked
KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length , in below type of pipe erected with 6A Modular type switch /
bell push & accessories and earth continuity of following type, erected
2 on PVC / Metallic/Wooden box, single mounting base frame covered 11.00 pt 375.72
with textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed. (e) in existing pipe erected flushed on
wall/ceiling complete Cat III
Replacing old & U/s by new Point wiring for FAN with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A Modular type switch
and hum free EME step type electronic fan regulator mounted and
accessories with earth continuity of following type erected on PVC /
3 Metallic/Wooden box, single mounting base frame covered with 4.00 pt 522.17
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector
as directed.(e) in existing pipe erected flushed on wall/ceiling complete
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of pipe
erected complete with Modular type switch & 5 pin Plug erected on
PVC / Metallic/Wooden box covered with appropriate front plate
4 modules erected on / in wall / ceiling as per pipe erected with following 4.00 pt 711.04
type of accessories. [II] For 16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board. (a) with medium class Rigid PVC
pipe and accessories erected flushed on wall/ceiling complete Cat. III
Replacing old & U/s by new Point wiring for on board Looped Plug
with 6A Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame covered with
5 textured / metallic/white front plate modules erected on / in wall / 6.00 pt 257.55
ceiling with following type accessories Cat III
Replacing old & U/s by new Providing & erecting following type of
Modular Type Accessories with necessary connection. As desired by
Engineer In charge (1) 6 Amp. SP one way switch
6b (4) 6 A socket 25.00 Ea 42.42
6c (2) 16 Amp. SP one way switch 18.00 Ea 51.51
6d (3) 6/16Amp. Universal socket 18.00 Ea 82.82
6e (5) LAN cable connector with ferule 15.00 Ea 36.36
Providing and erecting ISI mark Medium class RIGID PVC PIPES of
following size complete to be erected on/in wall or ceiling erected with
7 necessary PVC fittings & Junction boxes fixed with adhesive solution 20.00 Mtr 24.24
& Clamps with following dia of pipes, in approved manner as directed
Supplying and laying UPVC cable trunking system comprising
unplasticised polyvinyl, chloride rigid material with ignition free and
flame proof confirming BS with necessary end caps Internal and
8 external bend, flat bends, coupler, tee etc..All necessary accessories 65.00 Mtr 277.75
and measuring of following sizes (1) 75 mm x 50 mm trunking
Replacing old & U/s by new Providing and erecting Mains with
KV grade FRLS PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
9 stranded wire of green colour for earth continuity of following size (A) 592.00 Mtr 82.82
With medium class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq.
mm (OLD-60 MTR)
9b (a) 2 wire 1.5 sq. mm 40.00 Mtr 62.62
Replacing old & U/s by new providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on wall / ceiling with
10 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of 90.00 Mtr 112.11
green colour for earth continuity of following size (A) with medium
class Rigid PVC pipe and accessories (a) 2 wire 4 sq. mm OLD-30
10b (i) 4 wire 10 sq. mm OLD-15 MTR) 35.00 Mtr 425.21
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte
multi stranded, annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in existing pipe of
11 following size (Specifically for control panel, relays, power 25.00 Mtr 56.56
switchgears, motor starters & control wiring) with required size of
copper lugs, nuts and bolts if required. (e) One wire 6.00 sq. mm
11b (f) One wire 10.00 sq. mm 32.00 Mtr 91.91
11c (i) One wire 35.00 sq. mm 12.00 Mtr 300.98
Supplying & erecting approved make LAN cable of following size in
existing pipe as per direction [D] CAT - 6 e
Providing & erecting Switch board for Computer or electric apparatus
consisting of following modular type accessories mounted with PVC
/ Metallic concealed/open box with single mounting base frame
covered with textured/metallic /white front plate,modules erected with
13 necessary connections as directed 17.00 Ea 1133.22
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug For Modular Type Accessories Cat III
Decorative call bell Ting-tong box type 250 volts complete erected
Replacing old & U/s by new Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated
and high U.V. & corrosion resistance with diffuser with company
mark/name 160V to 270V, Power Factor more than 0.95, THD <
15%,CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt
15 ,LED LED driver efficiency > 85 %( fitting required LM-79 & LM-80 61.00 Ea 373.70
Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) (iv) 22-24 Watts, Surge - 2KV,IP-
20, conventional 4 feet Cat III
Supplying and erecting led lamps with following wattage capacity of
220 to 240 voltage, minimum 15000 burning hours life, 500 V in built-
surge protection,Polycarbonate diffuser, mounting suitable for E14 /
16 E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps integral type, with 3.00 Ea 188.87
PC diffuser suitable LAMP holder (iii) 10 to 15 watts Cat-III
Replacing old & U/s by new Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast
powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %,CCT 3000 K to
17 Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %( 3.00 Ea 758.51
fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges
shown.)(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting clips
complete.IP20 (iv) 22-24 watts, Surge-2 KV Cat-III
(B) LED Panel Light with provision for Plane front frame with
17b translucent cover fixed to housing complete.IP20 (vi) 36 watts, 24" x 14.00 Ea 1794.77
24", Surge- 2KV Cat-lll
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder coated
and heat sink extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
18 Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( 4.00 Ea 4997.48
fittings required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges
shown.) (A) Street Light (IP-65), Surge protection -4KV integral and
,Light must have 440VAC line supply with over-voltage protection. (ii)
60 Watts Cat-lll
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light
18b must have 440VAC line supply with over-voltage protection. (ii) 60 7.00 Ea 5599.44
(C) Post Top Lantern LED fitting comprises of finish cast aluminum
spigot and spun aluminum canopy fixed with opal polycarbonate, pipe
arrangement for vertical mounting driver and accessories wired upto
terminal block.IP 65 (i) 30W Cat-lll
Replacing old & U/s by new Providing and erecting Approved make
Four pole moulded case circuit breaker having breaking capacity ICU
of 25 KA. at 415 V,having normal current rating up to 25 A to 100A.
with Fixed thermal & magnetic release suitable to work on A.C. supply
19 50 c/s. with all internal connections, spreader tinned copper & 1.00 Ea 6173.12
complete erected in existing 16 G.M.S. housing. ICS=100% of ICU
Replacing old & U/s by new Providing and erecting Approved make
Four pole moulded case circuit breaker having breaking capacity ICU
of 35 KA. at 415 V. having Normal current rating 200A.with variable
20 Thermal & magnetic release suitable to work on A.C.supply 50 c/s. 1.00 Ea 16221.61
with all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S.housing ICS=100% of ICU only
Replacing old & U/s by new Supplying & erecting approved make
Four Pole 415V change over switch interior for panel mounting with
operating mechanism A.C.23 duty confirming to IS for (D)200A Cat-
Replacing old & U/s by new Supplying and erecting triple pole &
neutral 440V / 500V panel mounting Copper Busbars with four equal
Nos. of electrolyte bus having current density not more than 1.6 Amp. /
sq.mm (Rated current / cross section area) duly wrapped with colour
22 insulating tape for phase sequence of following current carrying 1.00 Rnmtr 1961.42
capacity, erected with necessary bus bar supports /insulators, main
cable socket to each bar, erected in existing cubical panel with
necessary connections. (A) Suitable for 100 Amp. Capacity
22b (B) Suitable for 200 Amp. capacity 1.00 Rnmtr 3202.71
Supplying Knife / Blade / DIN type HRC fuse link capable to
23 withstand 80 K.A. confirms to I.S. 13703 for following current 3.00 Ea 634.28
capacity (F) 250 Amp (Size I )
Replacing old & U/s by new providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to operate on 240 V A.C.
24 system and having breaking capacity 10 KA to be erected in existing 44.00 Ea 112.11
box. confirming to IS 8828/1996 with ISI Mark Cat.III
Replacing old & U/s by new Providing & erecting 240 V MCB double
pole switch for lighting Load (B Curve) having 10 KA breaking
capacity & confirms to IS : 8828 in existing box having following
capacity (A) 6 to 32 Amp. Cat III
Replacing old & U/s by new Providing & erecting 415 V MCB Four
Pole for Motor & Inductive Load (C Curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having following
capacity (c)63 Amp. Cat III
Providing and erecting Sheet Steel powder coated MCB distribution
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be
27 used of same company of MCB to be used) suitable for (A) single 1.00 Ea 885.77
phase incoming and horizontal single phase outgoing (b) sheet steel
double door (IP-43) (ii)6 way
Replacing old & U/s by new providing and erecting Approved make
RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and
Short Circuit withstand capacity of 10 KA and suitable for operation on
28 single phase 240 V,50Hz. having characteristic of quick action & 8.00 Ea 1969.50
tripping with all advance feature & do not incorporate any electronic
component. for following Max. rating erected as directed (i)
Amps.DP Cat III
Providing and erecting HOT deep Galvanised iron strip wire 8 to
Supplying & erecting earth pit of minimum bore dia.150mm size
approved make Earthing Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes
having Outer pipe dia of 50mm having 80-200 Micron galvanising,
Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value
surrounded by highly conductive compound with high charge
dissipation suitable for following type of applications with chamber
and heavy duty cover. (A)(approved make OEM has to submit test
certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the
30 value of earthing resistane mentioned in test Certificate) & having back 1.00 Ea 4591.46
filling compound of (B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted by
Agency. (a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Replacing old & U/s by new Providing & erecting weather proof, dust
& vermin proof, floor mounted front operated indoor type cubical
panel board necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet for outer
body & doors, 16 SWG thick CRC M.S.sheet for internal partitions
31 with necessary accesories , supporting angles/ flats channel including
cutting, bending, drilling, welding, riveting with internal partitions &
cable alley as per requirements & instruction of engineer-in-charge
with erection of
supplied switch gears, BUSBARS, suitable size of inter connecting
PVC copper wire / copper-aluminium strips, rubber grommets, rib,
bakelite control fuses/MCB for measuring instruments, earth bus &
earth bolts, foundation flange - bolts-base Plates, sufficient nos. of
hinged doors, handles with locking arrangement and rubber
gasket,heavy duty end terminal connection,danger notice
board,necessary ventilation,earthing strip complete. The Panel shall be
painted with epoxy powder coating.
(The rates excludes the cost of switchgears, bus bars, inter connecting
mains & Copper Aluminium strips, meters, Fuses etc. The dimension
shall be measured excluding base beams) The panel shall be supplied
with following approved manufacturers with following size. (A) locally 3.00 Sq.Mtr 10468.65
fabricated panel board (i) with 350 mm depth
Replacing old & U/s by new Providing and erecting XLPE(IS:7098)(I)-
88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV.
32 to be laid on wall with necessary clamps or in existing trench / pipe of 9.00 Mtr 284.82
following size of cables (C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm
32b (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) 5.00 Mtr 378.75
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe of following
size of cables (A) 4 core 4 Sq. mm
Providing and, fixing heavy duty flange type brass double compression
type cable gland with rubber ring for PVC insulated armoured cable
34 complete with out going tails, insulating tape etc for following size of 2.00 Ea 66.66
cables. (A) 3 core 35/50 Sq. mm
34b (B) 3 core 70 Sq. mm 2.00 Ea 89.89
Solder less crimping type Aluminium lugs conforming to IS suitable
for cable of following size evenly crimped with high pressure tool &
35 connected to switchgear terminals with brass/cadmium plated nut bolts 8.00 Ea 20.20
in an approved manner. (D) 35/50 Sq.mm.
Replacing old & U/s by new Providing and erecting Approved make
Ceiling fan with double ball bearing ISI mark with condenser A.C.
36 23OV.50 c/s.1200 mm. sweep complete, canopy erected on existing 26.00 Ea 1596.81
hook or clamp with earthing. [Make shall be approved by Engineer in
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S.
37 Pipe down rod erected duly painted for fan complete with proper 10.00 Mtr 108.07
insulation without leakage and earthing.
Replacing old & U/s by new Supplying & erecting approved make low
noise decorative exhaust fan having square frame ABS body with
inbuilt lowers & square frame.250mm with 1350 RPM Cat.II
Supplying & erecting approved make SMC press moulded composite
FRP. loop-in, loop-out approx. 2mm thick box complete with Bakelite
connector strip 5way(3P+N+E),DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements with mounting
39 clamp with nuts, bolts & washers suitable for erection on pole with 1.00 Ea 3420.87
cable clamps& earth bolt of following size of box. (I) 400mm x 300mm
39b (C)150mm x 125mm x 100mm [deep] 13.00 Ea 476.72
Supplying and erecting approved make single phase servo controlled
voltage stabilizer suitable for input voltage range 180/25OV. And
output voltage range 225/235V. A.C. complete erected. (B) 3.0 KVA
Replacing old & U/s by new Supplying and erecting Direct - On - Line
Starter with 18 A. rating contactor and with 3.5 Amp. 18A range
41 directly operated in totally insulated elegant enclosure for single phase 1.00 Ea 2100.80
operation up to 3 HP as per IS 13947 complete erected on P.W. Block
with necessary connection. Cat-lll
Replacing old & U/s by new S.I.T.C. of single phase submersible pump
set suitable for 100 mm size or more dia bore well having motor
capacity and discharge as under with necessary panel box. Lifting and
42 Lowering taken extra. (b) Motor rating 1.5 HP (16 stage) pump having 1.00 Ea 17607.33
capacity of 50 LPM at 60 mtr head suitable for 32 mm dia. delivery
Replacing old & U/s by new Supplying and erecting approved make
panel mounting type Digital Voltmeter having 3 digits LED display,
43 to 750 AC Volts range erected on existing panel board with all 1.00 Ea 1275.63
connection, wiring etc .with manufacturers calibration certificate.
Replacing old & U/s by new Supplying and erecting approved make
panel mounting type Digital Ammeter having 3 digits LED display,
external CT operated, calibrated for 0 to 1000 Amps suitable to operate
44 on 500 Volt AC , erected on existing panel board with all connection, 1.00 Ea 1558.43
wiring etc .with manufacturers calibration certificate.
Supplying and erecting Ammeter / Voltmeter selector switch for
45 phase AC Supply 500 V on existing panel board with necessary 2.00 Ea 317.14
Providing & erecting L.T. Current Transformer with bar primary 50/5
to 1000/5 ratio 15 VA burden erected in existing CRCA box duly
secured with insulating materials connected to the meter
Supplying and erecting approved make suitable panel indicator LED
47 type lamp, lens cover, complete erected with necessary connections. 6.00 Ea 43.43
AMOUNT PUT TO TENDER FOR RS.
Rupees Five Lakh(s) Three Thousand Six Hundred Fifty Three and paise Sixty Seven
(A) Total Tendered Amount Rs..…..……………….…………...…………….
(B) Rebate on above tendered amount (if any)………………..…..%(in Figure) Rs….………………….………………………...
(C) Net tendered amount (A-B) Rs……………………………………………….
All work shall be carried out as per Public Works Department Handbook and other specification of Division or as
Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold good for
Deputy Executive Engineer Executive Engineer
R&B Electrical Sub Division R&B Electrical Division
Porbandar Junagadh
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SCH A Prant Office Kutiyana.pdf
SCH B Prant Office Kutiyana.pdf
SBD Electric Work NEW Kutiyana Prant.pdf
DM Sheet Prant Office Kutiyana.pdf
NIT Kutiyana Prant.pdf
e tender Notice No. 03 of 2025-26.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .