Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹83,031
Closing Date
6 Jul 2026, 5:30 pmClosed
Karnataka Power Corporation Limited
VENKATESH G
Routine monitoring / Preventive maintenance / Breakdown / Emergency /Regular servicing of pneumatic cylinders, solenoid valves, Limit switches & Pressures switches pertainsto Units-5,6 &7 Mill Reject Handling System(MRHS).Operation and maintenance of Dense Phase Mill Reject Handling Systemof Unit-8.The work involves-a)Operation and maintenance of DPMRHS PLC systemb)I&C Maintenance works of Air Compressor.c)Servicing/re-calibration of solenoid valves,Limit/proximity switches & Pressures switches etc.Routine monitoring/maintenance of SPM analyzer systemspertains to Unit-5 to 8.The work involves-a)Operation and maintenance of DPMRHS PLC system.b)I&C Maintenance works of Air Compressor.c)Servicing/re-calibration of solenoid valves, Limit/proximity switches & Pressures switches etc.Routine monitoring/maintenance of SPM analyzer systems pertains to Unit-5 to 8.The work involves-a)Cleaning/servicing of transmitters & Reflector units and blower filters of SPM analyzers, pertains to Units-5 to 8.b)Carrying out maintenance works under the supervision of I&C engineerRegular monitoring/checking healthiness of Unit-7&8 coal bunker level monitoring systems.Routine maintenance of bunker level monitoring systems.The work involves- a) Cleaning/Checking of 3D Level sensors.b) Cleaning/checking healthiness of local control panel at bunker floor.c) Ensuring healthiness of signals to Control Room PC,DCS&CHP control room digital indicators.Regular monitoring/maintenance of HFO tanks Level measurement systems.The work involves-a)Cleaning/checking healthiness of Radar Level Transmitters installed at HFO tanksb)Cleaning/checking healthiness of local digital indicators installed at FOPH.c)Cleaning/checking healthiness of PLC unit installed at Unit Control Room-7.The nature of work is round the clock maintenance.The cleaning/servicing and maintenance works of all the above mentioned systems shall be carried out during units AOH period.The required T&P and PPE for carrying out maintenance works shall be arranged by the contractor/agency itself.
KPCL/2026-27/PS/WORK_INDENT4260
KPCL/2026-27/PS/WORK_INDENT4260
Open
Power stations
Two Tender Document System(Two Cover)
KPCL Executive Engineer IOLA2 Office RTPS Raichur
9 documents required · 7 mandatory · 2 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Proposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)
The intending bidder should have the experience as a prime contractorin executing at least one I&C Periodical Assistance/AOH/MOH maintenance works compulsorily in any thermalpower station of capacity not less than 210MW.As a proof of this single work order/work done certificate of value not less than Rs. 24.5 Lakhsin any one of the preceding five financial years (i.e., 2021-22, 2022-23, 2024-25, and 2025-26)shall be uploaded.(Previous year Work order/Work done certificate shall be given weight at 10% per yearto bring them to the present price level of the financial year 2026-27).
The intending bidder should be a CLASS-1 or above Electrical contractor. As a proof of this, valid electrical license issued by the competent authority of Govt. of Karnataka shall be uploaded
The intending bidder in his name should have achieved minimum average annual turnover of Rs.49 Lakhs in at least any two preceding financial years(2021-22, 2022-23, 2023-24, 2024-25, 2025-26). As a proof of this,the bidder shall upload certified copy of the profit and loss account OR turn over certificate duly certified by Chartered Accountant.(Financial turnover of previous years shall be given weight at 10% per year to bring them to the present price level of the financial year 2026-27).
₹1,040
₹83,031
12 Jun 2026
12 Jun 2026
1 Jul 2026
24 Jun 2026
19 Jun 2026
Periodical Special Assistance for the Annual Overhauling/Routine Preventive/Breakdown/emergencymaintenance works of I&C Systems/equipments pertains to Units-5 to 8 MRHS,SPM Analyzers,HFO tank level and Bunker Level Monitoring systems for a period Of ONE year.
Supervision of I&C works pertaining to Unit-5 to 7 MRHS, Unit-8 DPMRHS, HFO tanks level measurement systems, bunker level measurement system, Unit-5 to 8 SPM analyzers.
Assisting Plant Operation and Maintenance works of DPMRHS I&C systems/equipments of Unit-8 (1X250 MW).
Maintenance of Unit-5,6&7 MRHS System pertaining to A to F Mills along with its field pneumatic cylinders, solenoid valves, Air filter regulators, field local junction boxes and control panels.
Maintenance of Unit -5 to8 bunker level monitoring system consisting of A to F bunker level sensors, transmitters and its local control panels, HFO tanks-1&2 Level transmitters, local digital indicato...
Maintenance of Unit-5 to 8 SPM analyzers involves cleaning/servicing of local sensors, filters, purging blower systems and associated field instruments.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
PSA TENDER DOC 12062026.pdf
Tender Document • 0.68 MB
Corriegendum.pdf
pdf • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .