Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 CrAccepted-AOC 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹30.8 Cr | L1 | Accepted-AOC Accepted amount after deducting Schedule of credit amount of Rs.8,19,712.00 |
| 2 | L2₹32.3 CrRejected-Finance UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹32.3 Cr | L2 | Rejected-Finance Other than Lowest quoted tenderer |
| 3 | L3₹33.2 CrRejected-Finance | ₹33.2 Cr | L3 | Rejected-Finance Other than Lowest quoted tenderer |
| 4 | L4₹33.9 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹33.9 Cr | L4 | Rejected-Finance Other than Lowest quoted tenderer |
| 5 | L5₹34.6 CrRejected-Finance | ₹34.6 Cr | L5 | Rejected-Finance Other than Lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹19.1 L
Closing Date
24 Apr 2021, 6:00 pmClosed
CE_NAVY_VISAKHAPATNAM
CE_NAVY_STATION ROAD_VISAKHAPATNAM-530 004
PROVISION OF DEFICIENT MARRIED ACCOMMODATION 48 DUS APPROX FOR OFFICERS AT VISAKHAPATNAM
2021_MES_424855_1
CE_NAVY_VIZ_TOKEN_37_OF_19-20
Open Tender
Civil Works
1008 days
VISAKHAPATNAM
Please refer Tender documents.
11 documents required · 11 mandatory
₹3,000
GARRISION ENGINEER P NAVY
₹19.1 L
CE_NAVY_VISAKHAPATNAM
12 Jun 2021
24 Feb 2021
26 Apr 2021
24 Feb 2021
24 Apr 2021
12 Apr 2021
16 Mar 2021
Amount
Phase-I:
Schedule 'A' Part-I to Schedule 'A' Part-VIII: Note: Schedule 'A' Part-I to Part-XVIII are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 13 only.
Lump Sum price worked out by the contractor for 'Buildings & Structures' as listed in Schedule 'A' Part-I on Serial Page No.34[R][R]
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-II on Serial Page No.36
Lump Sum price worked out by the contractor for 'Pile Foundation', as listed in Schedule 'A' Part-III on Serial Page No.37
Lump Sum price worked out by the contractor for 'Internal Electrification', as listed in Schedule 'A' Part-IV on Serial Page No.39
Lump Sum price worked out by the contractor for 'Internal Water Supply', as listed in Schedule 'A' Part-V on Serial Page No.42[R]
Lump Sum price worked out by the contractor for 'Sewage Disposal', as listed in Schedule 'A' Part-VI on Serial Page No.44
Lumpsum price worked out by the contractor for 'External Water Supply', as listed in Schedule 'A' Part-VII on Serial Page No.45
Lump Sum price worked out by the contractor for 'External Electrification', as listed in Schedule 'A' Part-VIII on Serial Page No.48
Lump Sum price worked out by the contractor for 'Roads /Path/Hard Standing/Culvert', as listed in Schedule 'A' Part-IX on Serial Page No.50
Lump Sum price worked out by the contractor for 'Area Drainage', as listed in Schedule 'A' Part-X on Serial Page No.52[R]
Lump Sum price worked out by the contractor for 'Rain Water Harvesting', as listed in Schedule 'A' Part-XI on Serial Page No.53
Lump Sum price worked out by the contractor for 'Lightening Protection', as listed in Schedule 'A' Part-XII on Serial Page No.54
Lump Sum price worked out by the contractor for 'Solar Water Heater', as listed in Schedule 'A' Part-XIII on Serial Page No.55[R]
Lump Sum price worked out by the contractor for 'Fire Fighting System ', as listed in Schedule 'A' Part-XIV on Serial Page No.58[R]
Lump Sum price worked out by the contractor for 'Fire Alarm System ', as listed in Schedule 'A' Part-XV on Serial Page No.59
Lump Sum price worked out by the contractor for 'PVC Conduit]', as listed in Schedule 'A' Part-XVI on Serial Page No.60[R]
Lump Sum price worked out by the contractor for 'Dismantling/Demolition', as listed in Schedule 'A' Part-XVII on Serial Page No.63[R]
Schedule 'A' Part-XVIII: (Miscellaneous Items) (Pile Foundation, Internal Electrification, External Water Supply, External Electrification, Fire FightingSystem, Fire Alaram System, Aviation Light, Lightening Protection, Solar Water Heater, Geyser, DG Set, Lifts and Arboriculture):
PILE FOUNDATION:
Boring for bored cast-in-situ piles 600mm dia in any strata except hard rock and getting out and disposal of spoil out side Hydraulic system of boring method, complete all as specified and directed.
Boring for bored cast-in-situ piles 600mm dia in hard rock and getting out and disposal of spoil out side MD land using hydraulic system of boaring method complete all as specified and directed.
Boring for bored cast-in-situ piles 450mm dia in any strata except hard rock and getting out and disposal of spoil out side Hydraulic system of boring method, complete all as specified and directed.
Boring for bored cast-in-situ piles 450mm dia in hard rock and getting out and disposal of spoil out side MD land using hydraulic system of boaring method complete all as specified and directed.
Chipping out pile up to cutoff level incl disposal up to distance of 50m all as specified and directed.
Carrying out initial load test on 600mm dia pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out initial load test on 450mm dia pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out routine load test on 600mm dia pile as per IS 2911 Part IV complete all as specified and directed.
Carrying out routine load test on 450mm dia pile as per IS 2911 Part IV complete all as specified and directed.
Carrying out pull out test on cast on situ piles 600mm dia pile as per specified in IS ,complete all as specified and directed by Engr - in- charge.
Carrying out pull out test on cast on situ piles 450mm dia pile as per specified in IS ,complete all as specified and directed by Engr - in- charge.
Carrying out lateral load test on cast in situ piles 600mm dia piles as specified in IS and directed by Engr - in- Charge.
Carrying out lateral load test on cast in situ piles 450mm dia piles as specified in IS and directed by Engr - in- Charge.
Carrying out low strain integrity test on bored cast in situ piles, 600mm dia including analysing the result as per ASTM D 5882 and as directed by Engr - in- Charge.
Carrying out low strain integrity test on bored cast in situ piles, 450mm dia including analysing the result as per ASTM D 5882 and as directed by Engr - in- Charge.
INTERNAL ELECTRIFICATION:
Ponit wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor multistranded 1100 Volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marking, including pressed steel terminal box made with MS sheet 2mm thick suitable for fixing switches, sockets, inculding one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for One light point controlled by one switch or One bell point controlled by bell push or One fan (ceiling/Wall/Ex.fan) point controlled by one switch or One 3 Pin socket outlet 5 Amps socket on independent board.
All as per item No.36 here-in-before but One 3 pin socket outlet 5 Amps on the same board.
All as per item No.36 here-in-before but one light point controlled by two Nos. two way switches complete all as specefied and directed.
All as per item No.36 here-in-before but One 3 pin socket outlet 15 amps socket on independent board with FRLS PVC wire 4 sqmm for phase and neutral and one run of 4 sqmm copper cable green in colour for earth continuty conductor.
Supply and fixing LED adore lamp for AC 240Volt supply, B22 type, CDS five star, 10 watts of five star rated complete all as specified and as directed.
Supply and fixing ceiling fan AC single phase 230 V of size 1200 mm sweep, copper wound with complete set and fixtures such as canopy, down rod etc. 5 Star rating, metallic body complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specefied and directed.
Supply and fixing Exhaust fan 250 mm sweep or nearest size, plastic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as spcified and as directed.
Supply and fixing exhaust fan 300 mm sweep, (Heavy duty),900 RPM, complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening ,fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
Supply and fixing exhaust fan 380 mm sweep or nearest size, 900 RPM , (Heavy duty), complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening ,fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
Supply and fixing wall mounted fan 400 mm sweep or nearest size, suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary fixing arrangements etc., complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
Supply and fixing Energy efficient LED tube light fitting with tube 10 watts or nearest size ,240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Supply and fixing Energy efficient LED tube light fitting with tube 20 watts or nearest size ,240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded aluminium channel, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Supply and fixing LED Security light fitting with tube 30W New generation Energy saving &environmental frindly long lifemade up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc compelte all as specified and as directred.
Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 4x10sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(Bus bar trunk/MCCB to VTPN DB of each floor)
Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 4x6sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(VTPN DB to Energy meter and to Each DUs)
Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 2x6sqmm for phase and neutral duly colour coded and 1x6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.(for metal clad socket in each DUs)
Material and labour for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall, and PVC wire of size 2x2.5sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( parking, staire case and common area lighting DB of each floor)
Supply and fixing sheet metal enclosure with socket, plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp, 240 V AC, 50 Hz supply complete all as spcified and as directed.
Supply and fixing concealed in wall Vertical MCB DB double door type, TPN 4 way 415V, 50Hz , IP 43 protection with 200A rated bus bar , including provision for fixing MCCB FP 63 amp as incommer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specefied and directed.
Supply and fixing concealed in wall MCB DB. double door type, Single pole and neutral 06 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts nautral link, IP : 43 protection, complete all as specified and directed.
Supply and fixing three phase electronic Energy meter tamper proof with LED display, 415 volt , 50Hz AC supply, 5 to 20 amps capacity complete all as specified and as directed.
Supply and fixing prefabricated meter box made out of 2mm thick CRCA sheet duly powder coated of approx size 50cm x 60 cm to accommodate 4 Nos three phase energy meter , front portion of the meter box to be provided with four opening to take the reading of energy meter and the four slit is to be covered/fixed with glass, necessary sunmica sheet of suitable size to be provided inside the meter box to fix the energy meter, with locking arrangements complete all as directed and as specified. Note: Energy meter shall be measured and paid seperately.
M&L for earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth lead wire 4mm dia. by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe connected up to DBs, and suitable CI top cover with handle, funnel, strainer, char coal and testing on completion all as specified and as directed. Note:- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC (1:3:6) type C1 in pad and pit complete all as specefied and directed.(This caters for all relevant Schedules like DG set, Lift, Internal Electrification , External Electrification , Fire Fighting/ Fire Alarm, Solar water Heater & Lightening Protection)
M&L for earthing complete with copper plate electrode 60cmX60cmX3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to copper strip of 20mm x 3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note:- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC (1:3:6) type C1 in pad and pit complete all as specefied and directed.(This caters for Schedule of Internal Electrification)
M&L for GI earth strip of size 32x6mm with saddles and fixing screws etc. for roof/wall complete all as specified and as directed..(This caters for all relevant Schedules like DG set, Lift, Internal Electrification , External Electrification , Fire Fighting/ Fire Alarm, Solar water Heater & Lightening Protection)
EXTERNAL WATER SUPPLY:
Supply.lay, connect, test and commission Ductile pipe with double flanged centrifugally cast(spun) class K-9 of 100mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning including pipe fittings, jointing material and applying two coats of synthetic enamal paint (RED COLOUR) over a coat of red oxide primer etc. and all as specified and as directed.
M&L for construction of valve chamber of size 1000x1000x750mm (internal dimentions) including excavation of earth work in any type of soil, 50mm thick PCC 1:5:10 type E2 as in foundation, made out of 200mm thick brick work in cement mortar 1:6 with 15mm thick plastering in cement mortar 1:4 internally complete and up to 50mm below ground level for external faces with 100mm thick plain cement concrete 1:3:6 type B1 using 20mm graded aggregate as in coping, cover frame made up of 50x50x6mm and 3mm thick MS sheet as cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia. with neccssary locking arrangement including finishing the exposed steel sufraces with two coats of synthetic enamel paint over a coat of red oxide primer and two coats of white wash on plastered surfaces complete all as specified and as directed.
M & L for cutting existing DI pipe line 150mm dia. for alterations or additions necessarily done in position with out taking down and inserting 'TEE' of sixe 150x100x100mm for tapping complete all as specified and as directed.
Supply, Install, testing and commisssioning of monoblock pump set with minimum rating as 15 HP, 70M head, 5.1LPS with delivery size of 80mm bore, 4 Pole, 415 Volts, 50Hz, AC 3 Phase supply electric driven, inclussive of air valve delivery, pressure gauge along with cabling by XLPE copper cables from starter to pumpset with cable tray including necessary PCC foundation work etc. complete all as specified and as directed.
S & F flanged end lift type Foot valve 100 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed. (for Jockey pump) etc.
INTERNAL WATER SUPPLY:
S & F CP mixer for mixing hot and cold waterscrewed down for pipe of chromium plated , fancy type with two out going(one for bib tap and another for shower complete all as specified and as diredcted.
S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed suitable for 20mm PP-R pipe complete.
S & F Bib taps two way, fancy type w screwed down for size of 15 mm dia
S & F health faucet chromium plated , fancy type with steel flexible complete of size of 15 mm dia
S & F PVC connections 15mm size, heavy duty for hot water connection with PTMT nuts of length 450 mm complete.
EXTERNAL ELECTRIFICATION:
Supply, install, testing and commissioning SF6 insulated compact RMU extandable on both sides with rated voltage 11 KV rated current 630 Amps, short circuit breaking current 25 KA and making capacity 40 KA, fully arc proof metal enclosed, free standing, floor mounting, flush fronted type consists of manually operated non draw out type SF6 filled load break switch-01 No. (Incoming) and 2 Nos. outgoing SF6 filled load break switches with integrated relays and related CTs as specified below, cable switch module and an interlocking mechanism with the earthing switch with degree of protection all per the manufacturer's specifications complete all as specified and as directed. (a) Fixed type voltage indicators and electronic short circuit indicators for simple fault indication. b) Resin cast CT with ratio 75/1-1 with 15VA burden class1 for metering and class 5 P10 for protection-Set of three. Contd...
Supply, fix and testing of integral LED street light luminaire 40 Watts, comprising of epoxy powder coated, pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing complete all as specified and as directed. Make: Bajaj Cat. Part No.BRTFG36 W LED
Supply, install, test and commissioning of Solar Street Lighting luminair of capacity 60W Microprocessor based with Self contained solution i.e. Light on/off controlled by automatic daylight sensing including Earthwork excavation, Removal of Soil and PCC 1:2:4, Type B1 as in Filling / Foundation for fixing of Pole not less than 6m height,with IP 65 protection complete and consisting of the following: [a] Solar Panel with Polypropylene Silicon Cells. [b] PVC Coated Galvanised Pole of 6.0 m long of 4mm wall thickness [c] Solar Panel Capacity: 100 Wp [d] LED 60W Luminiaire in Powder Coated Aluminium housing.
Supply, fix and testing of loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knockouts for cable entry and exit, combi climate cable glands of IP 66/IP 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, 'C' curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands etc. complete all as specified and as directed.
S&F time switches 250 Volts single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
Suppy, fixing and testing of LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Main LT Panel) INCOMING: a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 500 A capactiy 36kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No. OUTGOING: a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 315 A capactiy 35kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 No.(Bldg & Spare) b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 200 A capactiy 35kA with adjustable type thermal and magnetic setting relays - 03 No. (APFC Panel ,F/F Panel & Spare) Contd...
c) MCCB AC 3 Phase 415 V, 50Hz 4 pole 100 A capactiy 36kA with adjustable type thermal and magnetic setting relays - 02 No.(DG AMF Panel & Spare) d) Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers. e) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breakers
Supply fixing and testing ofLT Panel board (Distribution Panel) made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 150 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(stand by DG supply panel) INCOMING: a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 100 A capactiy 35kA with adjustable type thermal and magnetic setting relays - 01 Nos OUTGOING: b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 35kA with adjustable type thermal and magnetic setting relays - 04 Nos(Terrace Pump ,Fresh water pump ,Lift machine room & Spare) c) MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 25kA with adjustable type thermal and magnetic setting relays - 02 No.(Street Light & Common Area Lighting) Contd...
d) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs e) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases.
Supply and fix sheet metal encloser, provision of fixing incoming and out going cables with bus bar for cable connection tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. (For lift machine room) INCOMING: a) MCCB AC 3 Phase 415 V, 50Hz,microprocessor release 4 pole 500 A capactiy 36kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No. OUTGOING: (a) MCB 32 Amp,16 KA TP - 04 Nos(for two lift panel + 02 Spare) (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases.
Supply and fix bus bar trunking system for the complete bldg power supply duly insulated three phase of rating 630 Amps 50 KA, 415 Volts insulated aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including following::- (a) End feed unit without MCCB - 01 No , (b) MCCB 630A, 50 KA, 4P, Icu=100%Ics, thermal and magnetic adjustable, with rotary handle - 01 No, (c) 630 A 3P 4W 100% Ne IP55 Aluminium Conductor Air insulated Rising mains Design indoor. - 48 RM, (d) Tap off Box (Metal type) with MCCBs 160A with rotary handle - 13 Nos (e) 160 A 3P 4W 100% Ne IP55 Straight feeder Aluminium Conductor Air insulated distribution for each floor design indoor. - 60 RM, (f) End feed Unit Box without MCCB's - 13 Nos, (g) Flange end - 14 Nos (h) End Covers - 14 Nos (i) Spring Hangers - 14 Sets (j) Bracket Supports - - 168 Nos
M & L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
ROADS /PATH/HARD STANDING/CULVERT
M&L for 250 mm thick WMM in two layers (compacted thickeness ) with brocken boulders or Quarry stone or Shingle or gravel as MORTH specifications interstices filled, surface formed and rolled and consolidated to required gradient and camber with 8 to 15 ton roller, complete all as specified and as directed.
GEYSER
S&F Supply, install, testing and commissioning water geyser 25 ltrs storage/heating capacity, Vertical type with automatic on/off switch, absolute ttemp range knob, heat indicator and other safety devices single phase, 50 Hz, 230 Volts ( incl inlet and outlet stainlee steel flexible connections pipe 15mm dia and accessories) all as specified and directed.
AVIATION LIGHT:
S&F aviation obstruction light LED type filament-less bulb with 10 Watt bulb including standard fixing arrangements complete all as specified and as directed.
S&F PVC insulated armoured PVC sheathed LT cable 1100 Volts grade with copper conductor of size 3 core 2.5 Sq.mm. multi stranded conductor, fixed to wall/roof etc. with suitable calmps, spacers, bolts & nuts including rigid PVC conduit 25mm dia. etc. complete all as specified and as directed.
S&F time switches 250 Volts single phase, 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
FIRE FIGHTING SYSTEM:
LT Panel board made out of CRCA sheet 2.0 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V , 300 A capacity complete with powder coating, necessary internal electric connection as required and as specified and directed. The Bus Bar rating shall be 300 Amp along with all accessories as specified hereunder: Incoming: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 160 Amp rated complete with overload protection, no-volt thermal based release. (Make: L&T / Schnieder/ Siemens.) Outgoing: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no-volt thermal based release - 02 Nos. (01 No Spare). [b] LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release - 06 Nos. (02 Nos for fresh water Pump, 01 No for DB-1,01 No for Jockey Pump and 02 No for Spare]. [c]Star delta starter of capacity 75 HP for electric driven fire pump - 01 Nos.
[d] Starter of suitable capacity for electric driven Jockey Pump - 01 Nos [e] LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases [f] Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power along with connected CTs.(Make:- Schinder / L&T/ Siemens) NOTE :- The Rate quoted shall inclusive of necessary automatic control system for ON/OFF of pump by sensing pressure in pipe line.
Material and Laboure for laying of Ductile pipe with double flanged centrifugally cast(spun) class K-9 of 150mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning (For external Ring main and upto Bldg) all as specified and as directed.
Supply and fix flanged end lift type Foot valve 80 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed. (for Jockey pump)
Supply and fix flanged end lift type Foot valve 150 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed. (for fire pumps)
Supply and fix LED EXIT light double sided with battery back up up to 2 Hrs. Complete with all accessories as directed.
FIRE ALARM SYSTEM:
S&F FRLS armoured copper cable 2 core 1.5 Sq.mm., passes through steel rigid conduit as per IS 1554 fixed to wall/roof/false ceiling/floors with necessary clamps/saddles complete all as specified and as directeed.
PVC CONDUIT
Supply and fixing telephone socket with and inclusive of prefabricated terminal box and plate for fixing telephone socket complete.
Supply and fixing TV socket with and inclusive of prefabricated terminal box and plate for fixing TV socket complete.
Suppling and fixing/drawingPVC insulated telephone cable one pair on existing PVC conduits concealed to wall . Make: Havells (WHTTATEL1P40) or equivalent make (Note:- PVC Conduit shall be measured and paid separately).
Suppling and fixing/drawingPVC insulated telephone cable four pair on existing PVC conduits concealed to wall . Make: Havells (WHTTATEL4P40) or equivalent make (Notr: PVC Conduit shall be measured and paid separately).
Supply and fixing PVC junction box of approx size 10cm x 15 cm rectangular type concealed to wall to accommodate PVC connebtor of four way for telephone cable.
Supply and fixing/drawing in concealed PVC conduit of CATV co-axial cable (Electrolytic grade solid annealed copper conductor, jelly filled, aluminium foiled and aluminium wire braided) on model RG 06 (foam) of Havells make or any other equivalent make. Note: (i) PVC conduid shall be measered separately. (ii) Proir to drawing of telephone conduit/ TV conduits, the contractor shall take necessary approval of diagram from Engr-in-Charge.
SOLAR WATER HEATER:
Supply, Install, testing and commissioning of 'Solar Hot Water System' (Evacuated tube Collector) based on indirect transfer of heat of capacity 400 LPD complete all as specified and as directed.
DG SET:
Supply, install, testing and commissioning of silent engine generating set with accoustic enclosure as per CPCB norms 415 Volts 62.5 KVA 3 Phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/2613/ 5000 complete all as specified and as directed, with and including the following:
(A) Alternator: Standard design alternator rated at 62.5 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 Phase 4 wire 415 Volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +1% at rated voltage from no load to full load, the alternator conforming to BS 2613/5000 and imposition to generate supply with frequency regulation with in +1% tolerance and suitable for tropical climate and shall generally conform to BS-2613/5000/IS 4722 complete with standard accessories all as specified and required for safe handling and operation salient features of accessories as under:
(i) Insulation class 'H‘ (ii) Temperature rise Class 'H‘ (iii) Excitation: Self Excited (iv) Regulation performance: The voltage is kept constant with +1%, manual voltage adjustment within +5% (v) Frequency regulation +1%
(B) Diesel Engine: Adequate capacity of diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories as under:
(i) Fly wheel with housing (ii) Cooling System: Moulded radiator with fan & belts (iii) Cooling Water Pump: Centrifugal type belt driven (iv) Exhaust System: Exhaust system complete with exhaust piping of suitable size with MS pipe of suitable size light grade up to & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer: Residual type Bellows (v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/frequency regulation, fuel filters, fuel hoses. (vi) Lub Oil System: Lubricating oil filter Lubricating oil pump (vii) Air Intake System: Air intake manifold Air cleaner dry type (viii) Governor: Electronic Governor
(ix) Starting System: Electric self starter with maintenance free battery including battery charging alternator. (x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch. Handling and operation: Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel (xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display. (xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine.
(xiii) Coupling Arrangement: Flexible coupling, fly wheel to suit flexible coupling (xiv) Accessories: AVM pads built in enclosure and for entire unit on platform. (xv) Base Frame: Should be provided as OEM norms. (xvi) Fuel Tank: Fuel Tank of capacity to suit Daily 12 hours service fuel tank made out of 2mm thick (14G) HR sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base inside the acoustic enclosure. (xvii) MS pipe line to and from the fuel tank to the DG Set.
(C) AMF Panel: Factory made inbuilt type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 Volts 3 Phase 4 wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 62.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 Pole MCCBs and contactors of capacity as recommended by the manufacturer including detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, KW, KWH, PF, temperature, battery voltage, etc. complete with standard accessories all as specified and required for safe handling and operation salient features of accessories as under:
(D) Accoustic Enclosure: Manufactured by OEM suitable for 62.5 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution Control Board (iii) The generating set batteries and control panel should be inside the enclosure. (iv) Fuel tank should be inside the enclosure (v) Construction Details/specification as follows: (a) Outer body: CRCA Sheet of 2.0 mm thick (b) Doors: CRCA sheet of 1.6 mm thick (c) Sound Insulation: As per OEM Norms
(vi) The acoustic should be composite in construction and fully assembled integral unit. (vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform. (viii) The fuel tank is to be located in substation building and cost of the fuel lines is deemed to be included in the offer. (ix) The DG set should be provided with external emergency stop push button. (x) The enclosure should be suitably illuminated by LED Lamp fittings. (xi) The noise level should be 75 dba at 1m under free field conditions. (xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade.
LIFTS:
(d) Four sleek circular 5 Watt LED light fitting in false ceiling (e) One sleek circular PVC heavy duty fan in false ceiling Make for (c) & (d): Philips/Bajaj/Havells/Crompton Greaves. (f) Aluminium chequered plate (3mm thick) as flooring joint in chequered palte should not more than one and top covering with granite flooring complete. (g) Non stop button/independent operation. (h) Over load warning indicator both audio and visual type with tripping sustem having relays etc. (Overload protectin/tripping system) (j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be conformity with IS 3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38mm hairline finish. (l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. (m) Mirror of 4mm thickness of suitable size as specified. (n) Opening with mirror of 5mm thick 200x800mm size in all the doors (Car/Landing doors) (p) Specification plate with complete details. (q) Contineuos earthing for machine and equipments. (r) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications. Contd...
(s) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete. (t) Full length display indicator panle. (u) Main drives and control shall be of latest, high effective and low power consumption. (v) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (w) Stainless steel front opend Car landing door with small opening for vision of size 200mmx800mm with toughended galss not less than 8mm thick. Make of Toughened Glass: Safgex/Saint Gobain Glass/Modiguard Float Glass/Kesar/Asshi Indian/Atul Tuf/Hindustan Pilkington Glass Works/ Trivenin Float Glass. (x) Intercome be connected with nearest security post Makes of Passagneer Lift: OTIS / Thyseen Krupp / MITSUBISHI / JOHNSON. Note: Defect liability period will be two years from date of completion.
(d) Four sleek circular 5 Watt LED light fitting in false ceiling (e) One sleek circular PVC heavy duty fan in false ceiling Make for (c) & (d): Philips/Bajaj/Havells/Crompton Greaves. (f) Aluminium chequered plate (3mm thick) as flooring joint in chequered palte should not more than one and top covering with granite flooring complete. (g) Non stop button/independent operation. (h) Over load warning indicator both audio and visual type with tripping sustem having relays etc. (Overload protectin/tripping system) (j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be conformity with IS 3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38mm hairline finish. (l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. (m) Mirror of 4mm thickness of suitable size as specified. (n) Opening with mirror of 5mm thick 200x800mm size in all the doors (Car/Landing doors) (p) Specification plate with complete details. (q) Contineuos earthing for machine and equipments.
(r) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications. (s) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete. (t) Full length display indicator panle. (u) Main drives and control shall be of latest, high effective and low power consumption. (v) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (w) Stainless steel front opend Car landing door with small opening for vision of size 200mmx800mm with toughended galss not less than 8mm thick. Make of Toughened Glass: Safgex/Saint Gobain Glass/Modiguard Float Glass/Kesar/Asshi Indian/Atul Tuf/Hindustan Pilkington Glass Works/ Trivenin Float Glass. (x) Intercome be connected with nearest security post Makes of Passagneer Lift: OTIS / Thyseen Krupp / MITSUBISHI / JOHNSON. Note: Defect liability period will be two years from date of completion.
ARBORICULTURE
Supply & planting Ashoka plant including preparation of ground up to 30cm deep and filling soft soil, cow dung and watering etc. complete all as specified and as directed.
Supply & planting Royal Palm tree including preparation of ground up to 30cm deep and filling soft soil, cow dung and watering etc. complete all as specified and as directed. Note for Item Nos.133 to 134: Loose soil and cow dung included in the unit rate quoted.
Phase-II:
SCHEDULE 'A' PART-XIX: Comprehensive maintenance of Electrically Operated Lifts for the First Year after Defect Liability Period under GE (P) Navy Visakhapatnam.
Comprehensive mainenance of electrically operated Passenger lifts (2 Nos.) (8 passenger) passengers to serve ground plus twelve upper floors complete including ARD and all connected components of liftduring 1st year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of electrically operated Passenger lifts (1 No.) (13 passenger) passengers to serve ground plus twelve upper floors complete including ARD and all connected components of liftduring 1st year after expiry of Defect liability period all as specified and directed.
Phase-III:
SCHEDULE 'A' PART-XX: Comprehensive maintenance of Electrically Operated Lifts for the Second Year after Defect Liability Period under GE (P) Navy Visakhapatnam.
Comprehensive mainenance of electrically operated Passenger lifts (2 Nos.) (8 passenger) passengers to serve ground plus twelve upper floors complete including ARD and all connected components of liftduring 2nd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of electrically operated Passenger lifts (1 No.) (13 passenger) passengers to serve ground plus twelve upper floors complete including ARD and all connected components of liftduring 2nd year after expiry of Defect liability period all as specified and directed.
Phase-IV:
SCHEDULE 'A' PART-XXI: Comprehensive maintenance of Electrically Operated Lifts for the Third Year after Defect Liability Period under GE (P) Navy Visakhapatnam.
Comprehensive mainenance of electrically operated Passenger lifts (2 Nos.) (8 passenger) passengers to serve ground plus twelve upper floors complete including ARD and all connected components of liftduring 3rd year after expiry of Defect liability period all as specified and directed.
Comprehensive mainenance of electrically operated Passenger lifts (1 No.) (13 passenger) passengers to serve ground plus twelve upper floors complete including ARD and all connected components of liftduring 3rd year after expiry of Defect liability period all as specified and directed.
Notes for item No 137 to 146: (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engineer-in-Charge.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid