Loading…
Loading…
Tender ID
Tender Value
₹1.6 Cr
EMD Value
₹1.6 L
Closing Date
17 Apr 2026, 4:00 pmClosed
State Project Director, Gujarat Council of School Education (GCSE)
Upgradation of 1 School for School of Excellence at various Location in BHARUCH district.
289565
SS/SOE/BHR/5405
Open
Civil - All
Works
Gandhinagar
3 documents required · 3 mandatory
₹3,600
State Project Director, GCSE, Samagra Shiksha, Gandhinagar
₹1.6 L
27 Mar 2026
27 Mar 2026
27 Mar 2026
17 Apr 2026
27 Mar 2026
Dismentalling tiled or stone floors laid in mortar including stacking
1 of serviceable materials and disposal of unserviceable materials with 189.95 46.77 Smt
all lead and lift.
Removing and scraping of old deteriorated plaster of any thickness
from wall/RCC member including staking of serviceable material and
disposal of unserviceable materials from site work with all lead and
Removing dry or oil bound distemper by a washing and scraping and
3 sand papering the wall and ceilling surface smooth including 482.44 10.99 Smt
necessary repairs to scratches complete.
Scraping oil paint from steel and other metal surface and making the
surface even (with Hand Scraping)
Excavation for foundation upto 1.5 m depth including sorting
out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(A)
Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m
including sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil
Filling with the available excavated earth (excluding rock) in
trenches, plinth, sides of foundation etc. in layers not exceeding 20cm
in depth consolidating each deposited layer by ramming and
8 of 20 cm. thickness inculding watering, ramming and consolidation 265.76 289.06 Cmt.
etc. complete.
Brick work using common burnt clay building bricks having crushing
9 strength not less than 35 kg./Sq.Cm. in foundationand plinth in 82.11 4772.86 Cmt.
Cement Mortar 1:6. (1‐ Cement : 6 ‐finesand)(C) Fly Ash Bricks
Masonry work with aerated light weight concrete Blocks of size
60cm x 23cm x 23cm or any other approved size, having crushing
strength @ 35 kg/sqcm Fixing with ready-mixed mortar
('Fixoblock'of M/s Ultratech cement Ltd./Rapid Fix/Lion) having
tensile adhision strength >0.8 N/mm2 and compressive strength of
>2N/mm2.The mortar is to be fixed in a thickness of 3mm to 5mm on
the clean and leveled surface of blockmasonry using proper trowel.
For all floor and lead and lift For superstructure.
Brick work using common burnt clay building bricks having crushing
strength not less than 35Kg./Sq.Cm. for superstructure in cement
mortar 1:6(1 cement :6 fine sand) including curing etc. complete. (C)
Fly Ash Bricks For all heights and all floor
Half brick in common brunt clay building bricks having crushing
strength not less than 35 Kg/sq.cm in cement mortar 1:4 (1 cement :
coarse sand) (C) Fly Ash Bricks in super structure including curing
etc. complete.For all floors
Providing & laying Cement Concrete 1:4:8 (1 Cement :4 Coarse
sand :8 hand brocken stone aggregates of 40mm nominal size) in
plinth and curing complete including cost of formwork. (A)
Foundation and Plinth - At plinth level
Providing and laying cement concrete 1:5:10 (1- Cement : 5- Coarse
sand : 10- hand broken stone aggregates 40 mm nominal size) and
curing complete including cost of formwork in (A) Foundation and
Providing & laying Cement Concrete 1:2:4 (1 Cement : 2 Coarse
Sand : 4 graded stone aggregate 20 mm nominal size) & curing
complete including cost of form work (A) Foundation and Plinth -
Below Tie beam, Plinth protection & surface leveling work.
Providing and laying cement concrete flooring 1:2:4 (1-cement : 2-
coarse sand : 4-graded stone aggregate 20mm nominal size) laid in
one layer and finished with a floating coat of neat cement. (A) 40mm
Providing and laying controlled cement concrete M.150 for curing
complete including cost of formwork and excluding cost of
17 reinforcement for reinforced concrete work in (A) 33.12 3905.10 Cmt.
Foundations, footings,Base of columns and Mass concrete
(Cement Level 290 Kg)
Description Of Item Quantity Rate Unit Amount
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and excluding the cost of
reinforcement for reinforced concrete work in (C) Coping Vertical
and horizontal for all floor (Cement Level 360 Kg)
Providing and laying controlled cement concrete M.250 and curing
complete including the cost of formwork and Excluding the cost of
reinforcement for reinforced concrete work in (A) Foundations,
footings, Base of columns and Mass concrete.(Cement Level 380 Kg)
Providing and laying controlled cement concrete M.250 and curing
complete including the cost of formwork and Excluding the cost of
reinforcement for reinforced concrete work in Plinth Beams.
(Cement Level 380 Kg)
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and excluding the cost of
reinforcement for reinforced concrete work in (C) Lintels all floor
(Cement Level 360 Kg)
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and excluding the cost of
reinforcement for reinforced concrete work in (C) Chajja all floor
(Cement Level 360 Kg)
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and excluding the cost of
reinforcement for reinforced concrete work in (C) Beams all floor
(Cement Level 360 Kg)
Providing and laying controlled cement concrete M.250 and curing
complete including the cost of formwork and excluding the cost of
reinforcement for reinforced concrete work in (D) Columns, Pillars
posts and struts all floor (Cement Level 380 Kg)
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and excluding the cost of
reinforcement for reinforced concrete work in (D) Columns, Pillars
posts and struts all floor (Cement Level 360 Kg)
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and excluding the cost of
reinforcement for reinforced concrete work in (C) Slab all floor
(Cement Level 360 Kg)
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and excluding the cost of
reinforcement for reinforced concrete work in (E) Staircases
including lending all floor (Cement Level 360 Kg)
Providing I.S.I. T.M.T Bars Fe.500D steel reinfocement (ISI mark)
28 Confirmed to IS-1786 for R.C.C.work including Cutting, bending, 56021.21 76.21 Kg.
binding and placing in position etc. complete.For all floors
Providing 10mm thick cement plaster in single coat on on
brick/concrete walls & Ceilling & Soffit of stair interior plastering in
cement mortar 1:4(1 cement 4 sand) watering, curing etc.
complete.For all floors
Providing 15mm thick cement plaster in single coat on rough or fair
side of single or half brick wall for interior plastering in cement
mortar 1:4(1 cement 4 sand) watering, curing etc. complete.For all
20mm thick sand faced cement plaster on walls above ground level
consisting of 12mm thick backing coat of cement mortar 1:3(1
cement 3 sand) and 8mm thick finishing coat of cement mortar 1:1(1
cement 1 sand) watering, curing etc.complete for any Height.
Finishing walls with 100% Premium acrylic emulsion paint having
VOC less than 50 gm/litre and UV resistance as per IS 15489:2004,
Alkali & fungal resistance, dirt resistance exterior paint of required
shade (Company Depot Tinted) with silicon additives. New work
(Two or more coats applied @ 1.43 litre/ 10sqm. Over and including
priming coat of exterior primer applied @ 0.90 litre/10 sqm, Item
Includes two coat of primar and putty with scafolding at all level of
work. As per Approval of Engineer Incharge.
Description Of Item Quantity Rate Unit Amount
Distempeing (Two coats) with oil bound washable distemper having
VOC content les than 50 grm/liter of approved brand and
manufacture and of required shade on wall surfaces to give an even
shade, over and including a priming coat and putty with alkali
resistance primer of approved brand after thoroughly brushing the
surface and other foreign matter and also including preparing the
surface even and sand parpered smooth As per Approval of Engineer
Painting two coates (Including Priming coat)having Low VOC
content over new steel and other metal surfaces with enamel
paint,primar coat, brushing, interior to give an even shade including
34 cleaning the surface of all dirt,oil, grease,dirt, dust and other foreign 524.59 122.65 Smt
matter with fine steel wood, scrapers and sand paper with ready
mixed priming paint brushing red lead etc. complete.(As directed by
Engineer in charge)
Providing and laying 25mm thick polished Kota stone
flooring/staircase treads (two pieces with three groves in front of
35 steps) over 20mm (average) thcik base of cement mortar 1:6 (1 230.19 976.72 Smt
cement 6 coarse sand) laid over and jointed with grey cement slurry
including curing, rubbing, and polishing etc. complete.
Providing & fixing average 25mm thick Double polished Kota stones
36 for shelves in cup board, seating plat form, including curing, rubbing, 28.24 796.89 Smt
polishing etc. complete. (As directed by Engineer in charge)
Providing & Fixing 25mm thick double polished vertical Kotah stone
37 for (partion)urinal as par drawing including round edge moulding etc 9.00 1335.14 Smt
comp. (As directed by Engineer in charge)
Providing and laying 18 mm thick mirror polished black granite
stone machine cut in single piece (Max. available) in sill and jambs
laid over 10 mm thick cemen mortar 1 : 3 (1 cement : 3 coarse sand)
38 and jointed with grey cement slurry with matching pigment incl. 23.10 2060.06 Smt
rubbing and polishing half rounding edge both side etc. complete
colour and shed as approved by architect engineer in charge. (As
directed by Engineer in charge)
providing & laying cement water proofing of average 60mm thick for
terrace for all floors using first layer cement mortar (1:3) over an
exsisting surface second layer of arranging brick bats acording to slop
adding suitable chemical to make water tieght & again third layer of
cement mortar 1:3 on above including adding water proffing
compound and finishing top with net cement slury using cement @
2.75 kg/sq mt. making any patterns and design on the top etc.
complete as directed.(As directed by Engineer in charge)
Providing & Laying Broken China Mosaic flooring for plain & curve
surface 12mm to 20mm of broken piece of ceramic tiles or Glazed
tiles ( one or more colour as directed by Engg. In charge ) to be laid
over cement mortar bedding of CM 1:3 to plain or and slopes and to
40 be tempered to bring mortar cream up to and colour pigment 481.32 747.29 Smt
including rounding of junctions and extending them pu to 15cms
along the wall and curing with bends any patterns of designs as per
deawing or directions including cleaning with water and oxilic acid
using 1 kg / 1 bag of water proofing materials.
Providing cement vata (10 cm X 10 cm size) quartar round in cement
mortar 1:1 including neat cement finishing, watering etc. complete
Respectely plaster acitivity shall be commenced only after completion
of vata work.
Providing & fixing in position mild steel door with ventilation frame
40x40x6 mm and shutter frame 35x35x5mm ,75x5 mm ms flate at
lock rail,10 mm square bar in vent at10 cm c/c coverd with
42 corrugated ms sheet 0.6 mm thick, including applying a priming coat 76.51 3693.19 Smt
of read lead paint including cleanicn the surface of all dirt, dust and
other foreign matter (As directed by Engineer in charge& approved
drawing and design etc.)
Description Of Item Quantity Rate Unit Amount
Providing & fixing in position mild steel window with ventilation
frame 35x35x5 mm and shutter frame 25x25x5mm ,10 mm square
bar grill at10 cm c/c coverd with corrugated ms sheet 0.6 mm
thick,including applying a priming coat of read lead paint including
cleanicn the surface of all dirt, dust and other foreign matter (As
directed by Engineer in charge& approved drawing and design etc.)
Providing and fixing FRP frame size 100x50 mm and
28mm thick FRP depress panel shutter having extra
reinforcement on sides & edges in Gel coat finish. The core
of the shutter & frame is to be filed up with
injected fire retardant grade polyurethene foam done
44 in situ alongwith embedded wooden pieces for 34.02 2377.76 Smt
stiffening & also taking hinges & fintures. The whole FRP
frame & shutter is to be water proof weather proof,
termite proof & resistance to mild acid/alkali. Rates are
to be inclusive of S.S hinges with necessary screws &
alluminium fixtures & fastenings & fastener sleeve.
Providing and fixing window having extruded aluminum Colour
Powder Coated section frame main outer size 63.50 x 38.10 x
mm(of Jindal Section no:4605,@ Wt 1.094 Kg / Rmt), horizontal two
track member size 61.85 mm x 31.75 mm x 1.20mm (of Jindal
Section no: 8687 @ wt.of 0.695 Kg/mt), vertical member of size
61.85 mm x 31.75mm x 1.30 mm (of Jindal Section no:8758 @ wt.of
45 0.0.659 Kg/mt) with sliding shutters of horizontal member size 40mm 34.65 1713.70 Smt
x 18mm x 1.29mm (of Jindal Section no:8949 @ wt.of 0.456Kg/mt),
vertical member of size 40mm x 18mm x 1.29mm (of Jindal Section
no:8947 @ wt.of 0.456Kg/mt/ Section 8948, @ Wt. 0.457 Kg/mt)
with 5 mm thick transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures and transparent silicon
sealant glass fixing to frame as per details etc complete for window.
Steel work, M.S Grill, welded in built up sections framed work
including cutting, hoisting, fixing in position and applying a priming
coat of read lead paint. (A)In beams and joists, channels angles Tees,
flats, with connecting plates or angle cleats as in main and cross
beams. Hip and jack rafters, purlins conneted to common rafters and
Providing & fixing G.I rain water Spout of 65mm dia and 60cm
Painting of logo on front side wall as directed by Engineer in charge
and as per approved drawing.
Providing and laying white glazed tiles 6mm thick in flooring
treads of steps and landing laid on a bed of 12mm thick
cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush
pointing in white cement.
Providing and laying white glazed tiles 6mm thick in skirting, riser of
50 steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3 341.59 946.50 Smt
coarse sand) and jointed with white cement slurry.
Providing and fixing Chicken mesh jali (22 gauge) 15cm wide at the
junction of 2 different surfaces of different material component at the
time of plastering to prevent cracking in plaster surface as and where
directed at all floors with all leads and lifts etc.complete.
Providing & Fixing Green board(2400mm x 1200mm) with soft
52 board(1200mm x 1200mm) on wall as per the drawing & design etc. 9.00 10352.50 NO
Providing and fixing pre-cast Rubber Dye / steel Dye inter
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 : 2006 including
mm Sand layer for levelling and filling the joint with sand in proper
line and level as per guidlines of IRC : SP 63-2018 etc. Complete.
Re-fixing of existing paver Blocks:
Fixing of existing pre-cast Rubber Dye inter locking concrete block
as per approved design including 35mm Sand layer for levelling and
filling the joint with sand in proper line and level etc complete.
Description Of Item Quantity Rate Unit Amount
Providing and fixing pre-cast concrete kerb stone of gray cement
based concrete block 30 cm length, 30cm height and 15cm thick of
55 M250 grade concrete as per aprooved design and including 100.00 361.64 Rmt
excavation for fixing in proper line and level, filling the joint with
C:M 1:3 (1 Cement : 3 Fine sand) etc. complete (uptp 10 ton).
Providing and fixing 1.20 Metre high fencing with 2.0 Metre long
M.S. Angle posts 40mm x 40 mm x6 mm and oil painting 3 coats
fixed at 2.5 Mt,C/c. with five Horizontan lines and two diagonals of
56 galvanised steel barbed wire weighting 9.38 Kg. per 100 Metre, 170.00 389.25 Rmt
strained and fixed to posts with G.I,staples including fixing the
postsin ground with 0.5 M x 0.5.M x 0.5 M. block in C.C1:5:10 etc
Provoding and supplying small dust bin (Green,Blue,Red,Black
57 yellow,) 7 Litres as directed by Engineer in charge, Approve Make- 14.00 290.38 NO
Cello, Aristo, Nayasa
Provoding and supplying big dust bin (Green,Blue,Red,Yellow)
58 Litres as directed by Engineer in charge Approve Make- Cello, 6.00 464.60 NO
Aristo, Nayasa
Provoding and supplying big dust bin ( Green,Blue,Red) 50 Litres as
directed by Engineer in charge Approve Make- Cello, Aristo, Nayasa
Providing and Fixing 5mm thick Acrylic Name Plate for dark zink
glare with braille lippi and fixing with double sided bonding tap and
screws as per direction of Engineer in charge of Size having 12'. X 4 '
etc. compl.
Providing and Fixing 5mm thick Acrylic Name Plate for dark zink
glare with braille lippi and fixing with double sided bonding tap and
screws as per direction of Engineer in charge of Size having 12" X
18" etc. compl.
Providing and laying tactile tile (for vision impaired persons as per
standards) of size 300x300x15 mm having with water absorption less
than 0.5% and conforming to IS:15622 of approved make in all
colours and shades in for outdoor floors such as footpath, court yard,
multi modals location etc., laid on 20mm thick base of cement mortar
1:4 (1 cement : 4 coarse sand) in all shapes & patterns including
grouting the joints with white cement mixed with matching pigments
etc. complete as per direction of Engineer-in-Charge.
Providing and fixing School of Excellence Logo Size ( 900mm x
900mm ),Aluminium Composite Panels (ACP) 3mm thickness,Coloe
Code - PS 33 Blue,High Glossy 3mm Orange Acrylic Embossing
63 Logo,Back Side Aluminium Section Framing ( 50mm x 25mm x 1.00 8208.61 NO
1mm )25mm is Side Of Frame and SS Hardware Finish on front side
of ACR wall as directed by Engineer in charge and as per approved
Providing and fixing Red Agra stone takti 0f size 600*600*12 to
mm having with approved SOE LOGO Letter and in ivory colour
with water based sealent coating finishing on wall in cement mortar
1:3 (1 cement : 3 coarse sand) in all shapes & patterns including
grouting the joints with white cement mixed with matching pigments
etc. complete as per direction of Engineer-in-Charge.
Construction of a soak well of as per the approved drawing & design
etc.in all sort of soil complete as directed and approved by engineer
65 14.04 5695.86 Per Cmt
incharge.( The internal In-to-in dimension shall be considered for
calculation)
Construction of a septic tank as per the approved drawing & design
etc.in all sort of soil complete as directed and approved by engineer
66 18.30 5316.36 Per Cmt
incharge. ( The internal In-to-in dimension shall be considered for
calculation)
Providing & fixing Stainless steel 316 Grab Bar 40mm dia.75Cm
long rail.as directed and approved by engineer incharge.
Construction of ICN Chamber as peras directed and approved by
engineer incharge.
Providing and fixing screw down bib taps of following size.(B) Brass
chromium plated screws down Bib Tap. (i) 15mm dia.
Providing erecting and fixing double coated ISI water tank of
70 required capacity each with all necessary fittings and connection etc. 1500.00 3.95 liter
complete on terrace
71 Providing & fixing UPVC ball valve(A) 15mm dia. 3.00 440.56 NO
Description Of Item Quantity Rate Unit Amount
Providing laying and jointing in true line and level
40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at
every two metre C/C or shall be concealed as directed
including necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing laying and jointing in true line and level
25mm dia.U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at
every two metre C/C or shall be concealed as directed
including necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing laying and jointing in true line and level
15mm dia.U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at
every two metre C/C or shall be concealed as directed
including necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive
solvent, including cost of all materials.
Providing & fixing to wall ceiling and floor 6.0 kg F/cm2 working
pressure PVC pipes of the following out side dia. Special density
complete with special flange compression type fitting,wall clips etc.
including making good the wall ceiling and floor.(G) 160 mm dia
Providing & fixing to wall ceiling and floor 6.0 kg F/cm2 working
pressure PVC pipes of the following out side dia. Special density
complete with special flange compression type fitting,wall clips etc.
including making good the wall ceiling and floor.(G) 110 mm dia
Providing & fixing to wall ceiling and floor 6.0 kg F/cm2 working
PVC pipes of the following out side dia. Special density complete
with special flange compression type fitting,wall clips etc. including
making good the wall ceiling and floor.(F) 75 mm dia
Providing and laying polished kota stone slab 25mm thick in risers of
steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3
78 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed 31.56 1121.48 Smt.
with pigment to match the shade of slab including rubbing and
polishing etc. complete.
79 Providing compose pit as per design and drawing. 2.00 23098.62 Each
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in
flooring treads of steps and landing laid on a bed of 12mm thick
cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with flush
pointing in white cement complete for antiskit
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in
skrting risers of steps and dedo on 10mm thick cement plaster 1:3 (1-
cement : 3-coarse sand) and jointed with white cement slurry
complete for antiskit
Providing laying and boring recharge well with the outer dimention
of 2.46 X 2.46 Mt along with the Slit chamber having outer
dimension of 1.46 X 1.46 Mt. The Slit chamber shall be as per the
approved drawing with PCC & Masonary work. The recharge well
shall be drilled up to 30Mt in all sorts of strata along with minimum
82 12 mt Strainer pipe of suitabel size, graval / aggregate packing, PCC, 3.00 71879.59 No
BBCC , Midium size gravel, Course sand, nyloin mesh, and
neccesarry tools tackels and quipment for sucessfully functioning.
The item shall be as per the IS 15797:2008 , approved drawing and
Approved by Engineer incharge.
Description Of Item Quantity Rate Unit Amount
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type switch / bell push &
83 accessories and earth continuity of following type, erected on PVC / 48.00 350.47 Pt.
Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed.(e) in existing pipe erected flushed on
wall/ceiling complete,Cat. III
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and hum free EME step type
electronic fan regulator mounted and accessories with earth
84 continuity of following type erected on PVC / Metallic/Wooden box, 48.00 489.85 Pt.
single mounting base frame covered with textured/metallic/white
front plate modules erected on / in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as directed.(e) in existing
pipe erected flushed on wall/ceiling complete,Cat. III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of pipe
erected complete with Modular type switch & 5 pin Plug erected on
85 PVC / Metallic/Wooden box covered with appropriate front plate 16.00 364.61 Pt.
modules erected on / in wall / ceiling as per pipe erected with
following type of accessories.[I] For 6A Plug and 6 a switch with 2-
1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board(e) in
existing pipe erected flushed on wall/ceiling complete,Cat. III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of pipe
erected complete with Modular type switch & 5 pin Plug erected on
86 PVC / Metallic/Wooden box covered with appropriate front plate 8.00 499.95 Pt.
modules erected on / in wall / ceiling as per pipe erected with
following type of accessories.[II] For 16A Plug and 16 amp switch
with 2-2.5 sq.mm Cu. Wire from mcb db board.(e) in existing pipe
erected flushed on wall/ceiling complete,Cat. III
Point wiring for on board Looped Plug with 6A Modular type switch
& 5 pin socket erected on PVC / Metallic/Wooden box, single
87 mounting base frame covered with textured / metallic/white front 32.00 241.39 Pt.
plate modules erected on / in wall / ceiling with following type
accessoriesCat. III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires erected in
below type of pipe with 6A Modular type switches and following
88 type of accessories erected on PVC / Metallic/Wooden box, single 16.00 449.45 Pt.
mounting base frame covered with textured / metallic/white front
plate modules erected on / in wall / ceiling as per pipe erected. with
necessary batten/angle holder or ceiling rose or H.D.Connector as
directed.(e) in existing pipe erected flushed on wall/ceiling complete
Providing following type of Modular Type Accessories mounted with
PVC / metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate , modules erected with
necessary connections as per site situation directed by Engineer In
charge.(10) 6/16Amp. Universal socket
Providing following type of Modular Type Accessories mounted with
PVC / metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate , modules erected with
necessary connections as per site situation directed by Engineer In
charge.(7) Blank Plate Single,Cat.III
Description Of Item Quantity Rate Unit Amount
Providing following type of Modular Type Accessories mounted with
PVC / metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate , modules erected with
necessary connections as per site situation directed by Engineer In
charge.(8) Computer RJ-45 socket ,Cat.III
Providing and erecting ISI mark embossed Medium class RIGID
PVC PIPES (F.R.L.S.)of following size complete to be erected on/in
wall or ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of pipes,
in approved manner as directed (a) 20 mm
Providing and erecting ISI mark embossed Medium class RIGID
PVC PIPES (F.R.L.S.) of following size complete to be erected on/in
wall or ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of pipes,
in approved manner as directed (b) 25 mm
Providing & erecting PVC Corrugated Flexible Conduit with
94 required nos. of coupling, PVC bushes, Check-nuts etc. complete of 8.00 20.20 Mtr.
following sizes.(2) 25 mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size,(E) in existing
pipe,(a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size,(E) in existing
pipe,(b) 2 wire 2.5 sq. mm
providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size,(E) in existing pipe,(a) 2 wire
providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size,(E) in existing pipe,(b) 2 wire
providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size,(E) in existing pipe,(g) 4 wire
providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size,(E) in existing pipe,(h) 4 wire
providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm
101 copper conductor FRLS PVC insulated stranded wire of green colour 30.00 380.77 Mtr.
for earth continuity of following size,(E) in existing pipe,(i) 4 wire
(use earth wire of 4 sq.mm )
providing and erecting Mains with ISI marked, 1.5KV grade
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
102 existing pipe of following size (Specifically for control panel, relays, 20.00 35.35 Mtr.
power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.(d) One wire 4.00 sq.
Description Of Item Quantity Rate Unit Amount
providing and erecting Mains with ISI marked, 1.5KV grade
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
103 existing pipe of following size (Specifically for control panel, relays, 20.00 87.87 Mtr.
power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.(f) One wire 10.00 sq.
Supplying and erecting Flexible PVC insulated multi strand multi
core 1.1 kv grade ISI marked copper wires of following size to be
erected as directed.(e) 1.50 Sq.mm 3 core round PVC sheathed
Supplying and erecting Flexible PVC insulated multi strand multi
core 1.1 kv grade ISI marked copper wires of following size to be
erected as directed.(c) 1.00 Sq.mm 2 core round/ flat PVC sheathed
Supplying & erecting approved make LAN cable of following size in
existing pipe as per direction,[C] CAT -
Providing & erecting Switch board for Computer or electric
apparatus consisting of following modular type accessories mounted
with PVC / Metallic concealed/open box with single mounting base
frame covered with textured/metallic /white front plate,modules
erected with necessary connections as directed
1 no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch
3 nos. 6A 5 pin Plug ,For Modular Type Accessories ,Cat. III
Decorative call bell Ting-tong box type 250 volts complete erected
Supplying and erecting LED indoor fittings with LEDs of wattage
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming to
IS: 513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name 160V
to 270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
109 Luminaire efficacy> 85 lumens/watt ,LED 48.00 295.93 No.
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
between the ranges shown.),(A) Tube Light with integral driver,(ii)
20 Watts, Surge - 2KV,IP-20, conventional 4 feet,Cat-lll
Supplying and erecting led lamps with following wattage capacity of
220 to 240 voltage, minimum 15000 burning hours life, 500 V in
built-surge protection,Polycarbonate diffuser, mounting suitable for
110 E14 / E27 / B22 lamp holders, pf >= 0.5(A) LED Lamps integral 12.00 112.11 No.
type, with PC diffuser suitable LAMP holder,(ii) 8 watts ,Cat-III
Supplying and erecting LED street light / Flood light fittings with
High power White LEDs wattage of 3 Watt and above assembled on
single MCPCB, efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power Factor more
111 than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio 15.00 4997.48 No.
>0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency
> 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE:
Below description have shown ranges of Wattage capacity of LED
between the ranges shown.)(A) Street Light (IP-65), Surge protection -
4KV integral and ,Light must have 440VAC line supply with over-
voltage protection.,(ii) 48 to 60 Watts,Cat-lll
providing and erecting Miniature circuit breaker single pole 0.5A to
2A system and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark
Description Of Item Quantity Rate Unit Amount
providing and erecting Miniature circuit breaker single pole 6A to
25A suitable to operate on 240 V A.C. system and having breaking
capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark , Cat.III
Providing & erecting 240 V MCB double pole switch for lighting
Load (B Curve) having 10 KA breaking capacity & confirms to IS :
8828 in existing box having following capacity (A) 6 to 32 Amp.
Providing & erecting 240 V MCB double pole switch for motor &
inductive load (C Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following capacity ,(A)
6 to 32 Amp. Cat.III
Sheets steel powder coated enclosure suitable for incorporating
One/Two nos. MCB.
Providing and erecting Sheet Steel powder coated MCB distribution
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should
be used of same company of MCB to be used) suitable for (A) single
phase incoming and horizontal single phase outgoing (b) sheet steel
double door,(ii)6 way (IP-43)
Providing and erecting Sheet Steel powder coated MCB distribution
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should
be used of same company of MCB to be used) suitable for (A) single
phase incoming and horizontal single phase outgoing (b) sheet steel
double door,(ii)8 way (IP-43)
Providing and erecting Sheet Steel powder coated MCB distribution
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should
be used of same company of MCB to be used) suitable for (A) single
phase incoming and horizontal single phase outgoing (b) sheet steel
double door,(ii)12 way (IP-43)
providing and erecting Approved make RCCBs conforming to IS:
12640 and having sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on single phase
120 V,50Hz. having characteristic of quick action & tripping with all 3.40 1969.50 No.
advance feature & do not incorporate any electronic component. for
following Max. rating erected as directed (i) 25 Amps.DP Cat-III
Providing & erecting Medium Voltage Danger Notice Board sticker
121 as per language suggested by engineer incharge of standard size as 3.40 26.26 No.
per IS-2551
Supplying & erecting in earthpit of minimum bore dia. 225mm size
approved make Safe Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250 Micron
galvanising, connection terminal dia of 14 mm with constant ohmic
122 value surrounded by highly conductive compound with high charge 2.00 4591.46 No.
dissipation suitable for following type of applications with chamber
and heavy duty cover.(approved make OEM has to submit test
certificate including value of earth resistane of installation.(a) For
Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Description Of Item Quantity Rate Unit Amount
Supplying & erecting in earthpit of minimum bore dia. 225mm size
approved make Safe Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250 Micron
galvanising, connection terminal dia of 14 mm with constant ohmic
value surrounded by highly conductive compound with high charge
123 dissipation suitable for following type of applications with chamber 2.00 5760.03 No.
and heavy duty cover.(approved make OEM has to submit test
certificate including value of earth resistane of installation.[b] For
Electrical installation up to 11 KV located in other than normal
soil i.e. Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of 25 Kg
Providing and erecting Annealed bare Copper wire 8 to 16 SWG.
Providing and erecting Pipe type earthing having 150 cms.long and
2.5 cms. dia. galvanised iron pipe with coupling and buch buried in
specially prepared earth pit complete with necessary 8 SWG earth
For using salt and charcoal / coke as required for pipe type earthing
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe of following
size of cables.(B) 4 core 6 Sq. mm
Providing & laying approved make Double walled corrugated pipes
(DWC) of polyethylene(conforming to IS 14930 II )with necessary
128 connecting accessories of same material at required depth in existing 125.00 62.62 Mtr
trench for laying of cable. below ground / road surface for enclosing
cable (A)50 mm outer dia
Providing & laying approved make Double walled corrugated pipes
(DWC) of polyethylene(conforming to IS 14930 II )with necessary
129 connecting accessories of same material at required depth in existing 85.00 95.95 Mtr
trench for laying of cable. below ground / road surface for enclosing
cable (C)90 mm outer dia
Providing & erecting Approved make Power Saving 50 Watt Ceiling
Fan with double ball bearing ISI mark with Condenser 230 volt A.C.
130 50 Hz 1200 mm sweep complete having 3blades with aluminium 48.00 1948.29 No.
blades with , canopy & 30 cm. down rod erected with earthing.(Make
shall be approved by Engineer in charge))
Supplying & erecting fan hook box of 10 mm M.S. round bar
bounded to the RCC bars up to 50mm length each side and pierced
through a 16 Gauge M.S. box / Heavy Duty PVC box complete
erected concealed in Ceiling with necessary finishing.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook
or Fan box.
Description Of Item Quantity Rate Unit Amount
Supply of approved make FRP Pole having following specifications:
FRP Light Pole made by CNC filament winding machine using
thermoset resin polyester/epoxy resin system) having minimum 62%
glass content. The pole should be in one piece and tapered round in
shape, having smooth finish and should be totally free from corrosion
as well as non conductive & shock proof Pole should be provided
with FRP Anchor Base and it should be heavy duty, or MS Material
duly painted with Epoxy paint. Pole should be flame retardant as per
IS 6746. Resin used shall be UV resistance and pigmented. A highly
weather resistant polyurethane coating shall be applied to the pole
after applying suitable primer system that ensures proper adhesion of
the paint. Minimum coating thickness shall be 80 to 100 micron.
133 Deflection of the pole shall not exceed more than 10% of the length 15.00 8252.71 Each
of pole for the given load“ Pole should be generally made as per the
dimensional data, performance criteria and some interchangeability
features of poles as per standard ANSI C 136.20 latest version or
ASTM D 4923/01 including cable termination box with necessary
accessories . The size of pole and type of installation with foundation
as per manufacturer details and site requirement are as below .(3)
Suitable for direct grouting & Single arm Bracket. [D] Overall length
of 5 Mtr. Average Thickness: 7mm.
Top/ Bottom OD Dia: 90/145 mm ± 3mm approx. approx. Weight of
Pole 25 kg approx.
Providing Aluminium arm bracket of having 2 sets of suitable
134 SS304 hardware for fixing the brackets & spread of 1.2 Mtr (Suitable 15.00 2234.12 No.
for 89 to 114 mm pole top dia) (A) Single arm bracket
Providing Aluminium arm bracket of having 2 sets of suitable
SS304 hardware for fixing the brackets & spread of 1.2 Mtr (Suitable
for 89 to 114 mm pole top dia) (B) Double arm bracket bracket
Supplying & erecting approved make SMC press moulded
composite FRP. loop-in, loop-out approx. 2mm thick box complete
with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting
mob & hinged doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable for erection
on pole with cable clamps& earth bolt of following size of box. (B)
250mm x 200mm x 100mm [deep]
Providing 1:2:4 cement concrete foundation & 70 % PCC from
bottom including excavation for the pole of size 45 x 45 x 100 cm.
Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm
dia x 45 cm) high upper ground level with necessary curing and
finishing in approved manner.
( for 4 & 6 mtr pole)
Supplying & erecting Amplifier having following specification:
Power Output :250W (RMS) (300W Max.)
inputs : 6 Misc. & 2 Aux.
frequency Response :50-1500HZ I3db
Tone Controls :Cut & Boost type
138 LED Meter :5 LED Arrays 2.00 11298.87 Ea
The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery)
with automatic changeover from AC to Battery operation, duly
protected by wrong Battery Polarity connections. [[Approved by
Competent Authority i.e. not Below the rank of Executive Engineer ]
Supplying & erecting recess wall mounting speaker with 5W rated
input power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz
frequency response with 6 inch dia. cone type 8 ohms speakers duly
fitted in ABS plastic cabinet of colour match with wall or ceiling of
following size. (b)Square shaped 260 x 260mm size speaker
Supplying, installing and testing approved make microphone for All
purpose, with frequency response of 100 - 11000 Hz, having
sensitivity 2.2mv / Pa & impedance 500 Ohms (LO- Z) supplied with
quick detachable holder, 6 mtr twin core cable & 3 pin XLR
connector. [[Approved by Competent Authority i.e. not Below the
rank of Executive Engineer ]
Description Of Item Quantity Rate Unit Amount
Providing and erecting water cooler having storage capacity 80Ltr. &
cooling capacity 40 Ltr.per hour @ an ambient temp of 45˚ C. The
outlet temp. of the water should drop by 15˚ C within a hour, The
water cooler should be comprising of hermetically sealed compressor,
fan motor, condensing unit, water tank surrounded by evaporating
coil, thermostats, relay etc. complete with necessary inlet & outlet
connection. The body of water cooler will be made from Stainless
Steel. ◦
Supplying & erecting 5 stage single reverse osmosis water
purification system with M.S. powder coated frame, prefilter housing
with 'O' ring presediment filter GAC filter, carbon filter suitable
142 buster DC pump capacity 80 psi, mention with 40 psi inline type post 2.00 13053.24 No.
carbon filter auto low & high pressure switches with following size of
storage tank & LPH capacity & erected as directed ,[B] 25 Ltr / Hr
with 30 Ltr. Storage Tank
SUPLYING, INSTALING, TESTING AND COMMISSIONING
OF Of your
premises of pipes and as per spec G.I. Pipe fittings such as Bends,
Tees, reducers, rubber insertions asnd galvanised nuts and bolts
includding Flow Directions Marketing, One coat of Primer, one coat
of Signal Red color 100 MM
SUPLYING, INSTALING, TESTING AND COMMISSIONING
OF Of your
premises of pipes and as per spec G.I. Pipe fittings such as Bends,
Tees, reducers, rubber insertions asnd galvanised nuts and bolts
includding Flow Directions Marketing, One coat of Primer, one coat
of Signal Red color 80 MM
Providing & Fixing Of SS, Fire Hydrant Single Headed Valve Isi
Mark, With 80 Mm N.B. Flanged Inlet, Ss 316 Orifice Plate, Ss
Spindle Controlled 63 Mm Dia Female Instantaneous Outlet Type. Ss
145 Coupling, Blank Cap, Chain, Twist Release Type Lug & All 3.00 7109.08 Nos.
Accessories Conforming To Is:5290 Including Fixing With Anchor
Fastner And Flanged Tapping From Wet Riser, Complete As
Providing and fixing 63mm Parole fire hose of approved grand
conforming to IS 636 type B having crushing pressure of
146 kg/cm 2 of ISI marked of 15 mtr length fitting with necessary S.S 3.00 8886.34 Nos.
63mm delivery hose coupling as IS 903 with ISI mark bided with GI
wire etc complete directed.
Providing & Fixing Of Of 63 Mm Dia Instantaneous Pattern Short
Branch Pipe, Made From Ss , Isi Mark, 20 Mm Dia Nozzle
Conforming To Is 903, Suitable For Inter Connection To Hose Pipe
Coupling Complete As Required.
Providing & Fixing Of Swinging Type Isi Mark, First Aid Hose Reel
In Red Colour Drum With 30 Mtrs Long 25 Mm Dia Heavy Duty
Rubber Water Hose, 25 Mm Dia Globe Valve Stop Cock,
Terminating With Ss Coupling & Nozzle Of 8Mm Outlet With Shut
Off Valve Confirming To Is 8090 - 1976 Complete With Ms Socket
For Tap-Off, Drum And Brackets (Including Painting) For Fixing On
Wall With Anchor Fastner, Bolts & Nuts Conforming To Is:884-
1969 Complete As Required.
Providing & Fixing Of Lockable Cabinet, Made Out Of Ms Sheet Of
20 Gauge Thickness Having Central Opening And 4 Mm Thick
Glazed Glass Doors (Twonos.) To Accommodate 1 Nos Of Hose
Pipe (15Mtr) And 1 No. Gm / Ss Branch Pipe Etc Suitably Marked
On The Outside With The Letters "Fire Hose" Including Necessary
Locking Arrangement And Shall Be Painted With One Coat Of
Primer And Two Coats Of Synthetic Enamel Paint Of Approved
Providing & Fixing Of Hand Lever Operated Butterfly Valve (100
Mm Dia) With Ci Body And Ss Disc With Epdm Linning With All
Required Accessories Like Flange, Teflon Gaskate, Gi Nut Bolts Etc.
Providing & Fixing Of Hand Lever Operated Butterfly Valve (80
Mm Dia) With Ci Body And Ss Disc With Epdm Linning With All
Required Accessories Like Flange, Teflon Gaskate, Gi Nut Bolts Etc.
Sitc Of Ci Non-Return Valves (100 Mm Dia) As Per Is:5312 (Part 1)
152 1984, Wafer Type With Required Flange, Nuts, Bolts And Gaskets 3.00 3585.50 Nos.
Etc Complete.
Description Of Item Quantity Rate Unit Amount
Providing & Fixing Of 2 Way Valve Isi Marked All Required Fitting
Accessories.3
Providing & Fixing Of 450 Lpm Fire Pump With Panel Isi Marked
154 All Required Fitting Accessories. . (One Year One Time Motor 1.00 62115.00 HP
Winding Warranty)(M.R.) 7.5 Hp
Sitc Of Gm 25Mm Dia Air Vent Valves With 25 Mm Dia. Ball
Valve, Nipple And Other Required Accessories.
Providing & Fixing Of Fire Proof 3.5C X 50 Sq Mm Cable As
Required Isi Marked All Required Fitting Accessories.
Providing ABC Type Fire Extinguisher 6 Kg Isi Marked All
Required Fitting Accessories.(M.R.)
Providing Co2 Type Fire Extinguisher 4.5 Kg Isi Marked All
Required Fitting Accessories.(M.R.)
Providing & Fixing Of Manual Call Point Isi Marked All Required
Fitting Accessories.(Boq)
Suplying, Instaling, Testing And Commissioning Of Fire
Hooter(M.R.)
161 Providing & Fixing Of Presure Meter Switch Isi Marked.(Boq) 1.00 6516.65 Nos.
Providing & fixing PVC water tanks as required on GROUND level
including making platform for bottom support and making necessary
162 13500.00 4.71 Liters
inlet, outlet and overflow connection etc. complete.(BOQ)
Providing and fixing to wall, ceiling & floor U.P.V.C (SCH
40) of the following Outside dia. Tube fitting and clamps, and
testing including making good wall and floor etc. (c) 75mm Dia.
Providing & fixing UPVC check or non-return fullway
valve(A)75mm dia.
165 Providing & eraction Core Cutting up to 200mm 4.00 858.50 Nos.
Supply & installation of Conventational , Fire Alaem Control Panel
Make Agni or similar
Total Rs. :
I/We am/are willing to carry out the work at………………….% above/below percent
(Should be written in figures and words) of the estimated rate mentioned above.
Amount of my /our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct……………………… % below Deduct……………………… % Above
In words In words
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
05-Building-SpecificationBook.pdf
ANNEXURE-FIRE.pdf
2017-02-15_TMT Lap Length Mesurement GR.pdf
ELECTRICAL_SPECIFICATIONS_GRS.18.05.2021.pdf
GR-Royalty.pdf
Technical Specification of Green chalk board.pdf
TUBEWELL SPECIFICATIONS_R1.pdf
DRW ACR 2.zip
ZIP
DRW ACR 1.zip
ZIP
DRW ACR 3.zip
ZIP
DRW ACR 4.zip
ZIP
SPECIAL CONDITION - COLOR.pdf
ANNEXURE-SPECIFICATION 1-2-Make list and Testing.pdf
BOQ-5405.pdf
R-5405.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .