Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC | ₹1.6 L Quoted ₹1.7 L | L1 | Accepted-AOC Agreement executed |
Tender Value
₹1.7 L
EMD Value
₹4,234
Closing Date
25 Feb 2026, 6:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer, PWD electricalsubdivision kasaragod
Electrical works
2026_PWD_831807_2
PWD/BLDG/TR/22990/2025_6_1_1/1
Open Tender
Electrical Works
Kasaragod
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
₹4,234
5 Jun 2026
19 Feb 2026
28 Feb 2026
19 Feb 2026
25 Feb 2026
19 Feb 2026
Electrification
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
90.3.21.3:Supply & installation of light fittings on 'C/U' shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD248930/2025-2026:Supply and providing the 9W LED lamp in the existing fittings as required
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
OD248963/2025-2026:Supply, and fixing of cast aluminum bulk head fitting with mesh guard giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD248927/2025-2026:Supply,conveyance,installation,testing and commissioning of 300/305mm sweep light duty exhaust fans in metal frame in the existing opening,fixing necessary Anchor bolts/bolts and nuts etc.,are required including giving connections with the supplied wire along with the exhaust fan
OD248962/2025-2026:supply conveyance installation,testing, commisioning of 450 sweep metal wall fan, fixing necessary clamps ,anchor bolts/bolt and nuts etc, as required including giving connections with the supplied wire along with the fan
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.2:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
OD248929/2025-2026:Supply and providing 25x3mm brass nut and bolt etc are required
OD248926/2025-2026:Supply and providing 12x3mm brass nut and bolt etc are required
Please Enable Macros to View BoQ information
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to: The Asst. Executive Engineer,PWD Ele Subdivision,Malappuram
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to: The Asst. Executive Engineer,PWD Ele Subdivision,Mananthavady
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Asst.Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to: The Asst. Executive Engineer,PWD Ele Subdivision, Kasaragod
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Asst.Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Technical sanction
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to: The Asst. Executive Engineer,PWD Ele Subdivision,Mananthavady
KERALA PUBLIC WORKS DEPARTMENT
Technical Saction
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to: The Asst. Executive Engineer,PWD Ele Subdivision,Malappuram
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to: The Asst. Executive Engineer,PWD Ele Subdivision,Malappuram
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Asst.Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Asst.Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to: The Asst. Executive Engineer,PWD Ele Subdivision,Malappuram
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Asst. Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to Asst.Enginner,PWD Electrical Section No.I, Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Asst Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Asst.Executive Engineer
PWD Electrical Division
Kozhikode
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
KERALA PUBLIC WORKS DEPARTMENT
Electrical Division
Electrical Sub Division
Amount of Estimate
Original Sanction, if any
Register No.
Reference No.
Returned to
Sanctioned as Divisional Register No.
Technically sanctioned for
Funds for the work to extend of
May be met from the detailed Head of Account
Executive Engineer
PWD Electrical Division
Kozhikode
Copy forwarded to: The Asst. Executive Engineer,PWD Ele Subdivision,Malappuram
Approved List of Materials
FRLS PVC insulated Copper Wire/Flex Wire /Flat cable
PVC Conduit (ISI Marked) Ivory only
PVC Accessories (ISI marked)
U G Cables (ISI marked)
Cable Glands/Socket
Boxes for Modular Accessories/Front Plates/ Modular type switches, Bell push, Plug Sockets,/ Stepped Electronic fan regulators, and other modular accessories [Group B Rohs]
Bracket, batten pendant holders (ISI marked)
Ceiling rose (ISI marked with Polycarbonate body)
RCCB/RCBO/Miniature isolator/MCB (10kA)
Enclosure for MCB DB
SDFU, SDU, COS [AC 23A duty]
Fuse base, fuse links
Enclosure for MCCB
LED tube Fitting
LED Bulb
Ceiling fan
Exhaust fan
Meters
Other Items
Declaration I/we……………………………………………………………………………………………………… …………………………………………………… (HE the name & address of the contractor), has personally verified the availability of the make of materials mentioned above with the local market and is convinced that they are available in the market. I agree to execute the work using the above mentioned makes only. I also assure that, I will not request for any change in materials at a later date.
Contractor
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1411904.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1411904.xls
BOQ • 0.35 MB
viewsbd.pdf
Tender Documents • 1.83 MB
viewnit.pdf
Tender Documents • 0.03 MB
materialslist.xls
Additional Documents • 0.18 MB
Download all tender documents and submit your bid