Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.8 CrAccepted-AOC | ₹71.8 Cr | L1 | Accepted-AOC Accepted being workable and reasonable rates |
| 2 | L2₹72.9 CrRejected-Finance | ₹72.9 Cr | L2 | Rejected-Finance Not being L1 bidder |
| 3 | L3₹73.7 CrRejected-Finance | ₹73.7 Cr | L3 | Rejected-Finance Not being L1 bidder |
| 4 | L4₹79.1 CrRejected-Finance | ₹79.1 Cr | L4 | Rejected-Finance Not being L1 bidder |
| 5 | L5₹89.4 CrRejected-Finance | ₹89.4 Cr | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹72.7 Cr
EMD Value
₹15 L
Closing Date
16 Apr 2022, 6:00 pmClosed
DDG CE
DDG CE Naval Base Post Visakhapatnam 530014
PROVISION OF MARRIED ACCOMMODATION FOR SENIOR SAILORS WITH RELATED FACILITIES AND SERVICES UNDER WP 03
2021_MES_492220_2
DDG CE V TOKEN 10 OF 2021 2022
Open Tender
Civil Works
730 days
Rambilli
As per NIT
9 documents required · 9 mandatory
₹3,000
DGNP
₹15 L
Yes
1 Jun 2022
22 Mar 2022
18 Apr 2022
22 Mar 2022
16 Apr 2022
6 Apr 2022
Amount
Lump sum amount worked out by the contractor for "Buildings & Structures" as listed in Schedule 'A' Part-I (pre-priced by DGNP) on Serial Page No. 46
Lump sum amount worked out by the contractor for "Site clearance / Area Development / Earthwork excavation/Hill Cutting" as listed in Schedule 'A' Part-II (pre-priced by DGNP) on Serial Page No. 47
Lump sum amount worked out by the contractor for "Internal Water Supply" as listed in Schedule 'A' Part-III (pre-priced by DGNP) on Serial Page No. 49
Lump sum amount worked out by the contractor for "Internal Electrification including Telephone / TV / Internet" as listed in Schedule 'A' Part-IV (pre-priced by DGNP) on Serial Page No. 53
Lump sum amount worked out by the contractor for "FIRE PROTECTION OF BUILDINGS" as listed in Schedule 'A' Part-V (pre-priced by DGNP) on Serial Page No. 54
Lump sum amount worked out by the contractor for "Lightning Protection" as listed in Schedule 'A' Part-VI (pre-priced by DGNP) on Serial Page No. 55
Lump sum amount worked out by the contractor for "LIFTS" as listed in Schedule 'A' Part-VII (pre-priced by DGNP) on Serial Page No. 57
Schedule "A" Part - VIII: [Miscellaneous Items] [Internal Water Supply, Internal Electrification, Telephone/TV/Internet, Lightning Protection, External Water supply, Fire Protection of Buildings, Aviation lights and Lifts]: [To be quoted by the bidder.]
M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade confirming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including factory made MS boxes, modular cover plates with frame for mounting modular switches, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan point controlled by one way switch, complete all as specified and as directed.
Description all as per Serial Item No. 9 here in before but for light / fan point controlled by two twoway switches complete.
Description all as per Serial Item No. 9 here-in-before but with 2.5 Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 3 pin 5Amp switch socket point, on independent board, complete all as specified.
Description all as per Serial Item No. 9 here-in-before but for 3 pin 5Amp switch socket point, on Same board, complete all as specified.
Description all as per Serial Item No. 9 here-in-before but with 2.5Sqmm copper conductor cable and 2.5Sqmm cable as earth continuity conductor for 3 pin 5/15Amp switch socket point, on independent board, complete all as specified.
Description all as per Serial Item No. 9 here in before but for Bell / Buzzer point controlled by bell push complete.
Supply and fixing twin core copper telephone cable of size 0.5sqmm, PVC insulated PVC sheathed, complete all as specified.
S&F Telephone jack with shutter glossy white RJ 11 port with suitable gang box, complete all as specified and directed.
S&F Data socket white glossy RJ 45 and RJ 11 Port with suitable gang box and face, complete all as specified and directed.
S&F TV socket outlet, delux with suitable gang box, complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing on completion, complete all as specified and directed. Note: Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
All as per Serial Item No. 19 here in before but using galvanised iron strip 25 x 4mm earthing lead and 40mm bore GI pipe medium grade as protection pipe.
All as per Serial Item No. 19 here in before but using galvanised iron strip 32 x 6mm earthing lead and 50mm bore GI pipe medium grade as protection pipe. .
Supply, laying, testing and commissioning of Ductile Iron pressure pipe of 150mm bore with flanged type ends jointed with with rubber or fibre board gasket and confirming to IS-8329:2000, class K-9, PN-10 rating, with pipe lining inside with cement mortar (CML) outside with bituminous coating all as per Annx `C' of IS-8329, laid in trenches / floor, complete all as specified and as directed. Note: 1. Necessary earth work will be measured and paid separately. 2. Necessary fittings will be measured and paid separately
M&L for DI Specials such as Bends , tapers any type, Tee pieces, single branch, "Y" junction, double branch, cross (for all flanged pipe) collars, caps and plugs for connecting up to 150mm bore DI Pipe all as per IS:9523, complete all as specified and as directed. Note: Fittings shall be of same grade and class as per main pipe.
S&F Fire escape route map drawn on glow sign board / flex in required colour, letters and arrows at every 2m interval, for upto Stilt+8 floor buildings, complete all as directed by Engineer- in- charge.
Supply, fixing and installation of Integral LED 48Watts aviation obstruction light new generation, PF>0.95, > 100 lum/W, 220Volt, with aluminium housing and polycarbonate enclosure and IP 66 protection, with suitable GI pipe bracket with clamps, all accessories and internally pre wired and connecting up with three core twisted flexible copper conductor cable with suitable size, complete all as specified and as directed. Make Bajaj /Philips / Wipro/GE/CG / Havells
S&F Sheet metal enclosure SPN, 8 way 230 volts, single door type, without bus bar complete all as specified and as directed, with and including following: (i) MCB SPN, 6-32Amps, 10kA -01 No (ii) Timer switch ON/Off -01 No
S&F AFFF type fire extinguishers - mechancial foam type 9 litres capacity, complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets, etc., complete all as specified.
S&F CO2 fire extinguishers - 4.5 Kg capacity, complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets etc confirming to IS : 15683 with ISI mark, complete all as specified.
S&F Dry chemical powder extinguishers, 9Kg capacity, complete with intial charge, gun metal cap, discharge hose with nozzle wall fixing brackets etc., confirming to IS : 15683 with ISI mark, complete all as specified and as directed.
Design, Supply, Install, testing and commissioning of pumping set, electrically driven, centrifugally type conforming to IS with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings, suitable for continuous operation with range of operation 0% to 150% of rated capacity for 440V, 3 phase, 50Hz, 30mtr head, 450 LPM discharge, with and including suitable foot valve with Y strainer with cored hole/slots star delta starter, necessary fixing arrangement, soft starter, MF meter, MS frame and PCC foundation and suitable LT panel as per OEM Specification, complete all as specified and as directed. Note: The contractor shall submit drawings for approval before manufacturing at factory and pumps/motors shall confirm to GRIHA 3 star rating.
Supply, laying, testing and commissioning of FRLSH PVC insulated unsheathed copper conductor cable of size 2.0 core x 1.5Sqmm, 1100 volts grade and including cable glands, ferrules and connected accessories, multi stranded 1100 Volt grade confirming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes, complete all as specified and as directed.
Supply, laying, testing and commissioning of FRLSH PVC insulated unsheathed copper conductor cable of size 3.0 core x 10.0Sqmm, 1100 volts grade and including cable glands, ferrules and connected accessories, multi stranded 1100 Volt grade confirming to IS 694: 1977, complete all as specified and as directed.
Supply, Install, testing and commissioning of Microprocessor based intelligent addressable fire alarm repeater panel with graphic disply and software with latest IS, complete all as specified and as directed.
S&F Galvanised steel water tubing 50mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc), laid in trenches/drains, including testing, complete all as specified and as directed.
S&F Galvanised steel water tubing 25mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc), laid in trenches/drains, including testing, complete all as specified and as directed.
S&F Gun-metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally, IS-778 marked, Class-2, suitable for iron pipe of 50mm bore, complete all as specified and as directed.
S&F Gun-metal gate valve, painted finish, with forged brass spindle and iron wheel head, screwed both ends internally, IS-778 marked, Class-2, suitable for iron pipe of 25mm bore, complete all as specified and as directed.
M&L for Valve chamber of size 1000mm x 1000mm x 600mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, PCC solid block masonary200mm thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) upto 150mm below GL and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces, complete all as specified.
S&F LED bulb 1x10Watt, 230Volt, P.F>0.95 with and including bracket holder PVC/polycarbonate type with cord grip cap suitable for LED lamp, complete all as directed by Engr-in-charge.
Supply, installing testing and commisioning of LT Pannel factory made indoor type dust and vermin proof as per IEC 61439 (CPRI Approved OEM) fabricated out of CRCA Sheet 2mm thick painted with epoxy powder gun paint as per OEM flow mounted with raised platform of suitable size IP 65 ratting, 3 Phase 4 wire with whether proof with rated operational voltage 433V, rated insulation voltage 1000V and impulse with stand of 12 KV and minimum internal arch withstand of 65KA 500m Sec as IEC-61641 whether proof with separate hinge door per each compartment with handle, locking arrangement, back door openable, fixed with angle iron (50 x 50 x 6 mm) frame grouted in PCC 1:2:4 with aluminium cable glands with and including following accessories:- Incoming: MCCB 125 Amp microprocessor based, 4 pole, 16 KA, 415 Volts-01 No, Outgoing: (a) MCB 40 Amps SPN 10 KA 230 Volts - 04 Nos, tempered proof digital energy meter of accuracy class 1 240 Volts 50 Hz with LCD display 10-60 Amps (measures and displays KWH, V, I, KW, PF, Last month history of KWH, MD is in KW)- 04 Nos, Space for 02 Nos of 125 MCCB 4 Pole.
SCHEDULE 'A' PART-IX [PHASE -III]: OUTSOURCING SERVICES FOR MANNING & OPERATION LIFTS DURING FIRST YEAR OF DEFECTS LIABILITY PERIOD:- Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-VII, during 1st year of defects liability period, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
SCHEDULE 'A' PART - X [PHASE -IV]: OUTSOURCING SERVICES FOR MANNING & OPERATION LIFTS DURING SECOND YEAR OF DEFECTS LIABILITY PERIOD: Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-VII, during 2nd of defects liability period, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-VII, during 1st year after expiry of defects liability period, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-VII, during 2nd year after expiry of defects liability period and After completion of first year Comprehensive Maintenance, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
Outsourcing Services for manning and operation of Electrically Operated passenger lifts 13/08 passengers (2Nos in each block) to serve different floors as mentioned at Items in Schedule 'A' Part-VII, during 3rd year after expiry of defects liability period and After completion of 2nd year Comprehensive Maintenance, in 03 shifts (each shift 08 hours) per day including Sundays & Holidays, by providing one Lift Operator (Semi Skilled) for each Shift, complete all as specified and as directed.
Som Projects Pvt. Ltd.
DES RAJ AND SONS BUILDERS PVT LTD
Jatan Constructions Private Limited
SLC PROJECTS Pvt Ltd
PUSHKARRAJ CONSTRUCTION PRIVATE LIMITED
RANK PROJECTS AND DEVELOPMENT PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid