Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 CrAccepted-AOC SCO 36 SECTOR 7 C MADHYA MARG CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹9.0 Cr Quoted ₹9.4 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹9.5 Cr+₹7.2 L (0.77%)Rejected-Finance VILLAGE KAIRWAN KARANPUR PO RAJPUR DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | ₹9.5 Cr+₹7.2 L (0.77%) | L2 | Rejected-Finance 2 Lost |
| 3 | L3₹10.7 Cr+₹1.4 Cr (14.4%)Rejected-Finance 1ST FLOOR B 116 VIBHUTI KHAND GOMTI NAGAR LUCKNOW U P | LUCKNOW | LUCKNOW | UTTAR PRADESH | ₹10.7 Cr+₹1.4 Cr (14.4%) | L3 | Rejected-Finance 3 Lost |
Tender Value
Refer Docs
EMD Value
₹17.9 L
Closing Date
14 Dec 2022, 5:00 pmClosed
Superintending Engineer
Office Of Superintending Engineer Construction Circle Uttarakhand Peyjal Nigam Pauri
construction of all Civil and E M, Surveying, Design, Supply, Cartage laying Jointing of GI API Pipe of 15mm to 80mm dia by Socketing Electric arc welding, Const. of R.C.C Intake Well of 6.00 m internal dia , RCC Circular Sump CWR 2 KL to 90 KL Cap
2022_MDPEY_52124_1
2988/Nivida Quotation/246 dated 26-11-2022
Open Tender
Civil Works - Water Works
Item Wise
365 days
Dugadda
as per Tender Document
3 documents required · 3 mandatory
₹5,900
Executive Engineer, C.D. Peyjal Nigam Kotdwar
₹17.9 L
kotdwar
27 Sept 2023
30 Nov 2022
16 Dec 2022
30 Nov 2022
14 Dec 2022
8 Dec 2022
30 Nov 2022 - 5 Dec 2022
5 Dec 2022
Amount
Supply of all materials, labour, T&P, diversion of river water making coffer dam, dewatering etc required for construction of one no circular water tight RCC intake well of 6.00 m internal dia & 15.00 m height with Pump house 4.00 m height designed to with stand safely the effects of seismic effect, wind effect and water current forces in kho River near Matiyali Village by well sinking or open excavation as per site requirement on 8 T/m2.Details of works will be as follows----
Testing of bearing capacity of soil from a recognized University in the presence of site in charge.
The detailed structure design and drawing or the foresaid intake well showing all details based on BC report should be supplied by the contractor within 15 days from the date of acceptance .
The floor of intake well shall be 5.00 m below the LWL .
Intake well have 4 nos RCC inlet channels internal size 75cmX 75cm extending radially upto a distance of 4.00m from the outer face of intake well. These inlet channels shall be properly supported and embeded in the river bed. So as to withstand the damaging effects due to excessive water current and flowing debris during floods rainy season. The projected length of the channel out side the wall may vary as per site requirement.
Three nos 150 mm dia GI (Medium) perforated pipes for inlet with proper sluice valve arrangement will be grouted in the intake well at proper place. These pipes will pass through the inlet channels and shall be covered with pebbles around it. The perforated pipes shall be arranged by the contractor.
The RCC shaft of intake well will be one meter above HFL.
The circular pump house above the shaft of intake well will be of 23 cm thick brick masonry in 1:6 cement and coarse sand mortar.
The floor of pump house i.e. deck floor slab capable of accommodating to motors of 700 LPM discharge and pumping head 180mtrs V.T. pumps shall have 0.6m opening on either side of the centre of floor throughout the dia as shown in drawing. This opening will also provide acess for the stair case . The opening will covered by the MS Jal as per direction of Engineer –in-charge.
One meter wide circular balcony shall be provided all around the outer face of intake well shaft. This balcony shall have 1.2 m high, RCC railing post at a distance of not more than 2.5m. The railing post shall support three rows of 20mm dia GI pipe of medium quality, the pipe will be supplied by the contractor.
The roof of pump house will be 4.50 m above the floor level of pump house and will be projected 1.00m all around the outer face of wall of pump house will proper slope for drainage.
One M.S. girder of suitable size and 6.50 m length will be fixed 30 cm below the roof level along the diameter of pump house in the centre of opening left in the floor of pump house. (item no ‘h’) as per direction of Engineer – in –charge.
The Pump house will be provided with one door of 1.2m x2.1m and 3 fully glazed windows of 1.2m x 1.8m. The door and windows will be provided with 50x50x6 mm angle iron frame,1mm thick MS sheet door and glazed Z- section window of 4 mm thick glazing or as per direction op Engineer in charge as per site requirement .
Suitable provision for 2.50 m wide and 15m span RCC foot bridge for making approach path to intake well shall be made with railing of 20 mm dia GI (M) pipe in 3 rows and RCC railing posts, pipes to be arranged by the contractor.
All masonry works should be plastered on both face with 1:6 cement, coarse sand, mortar 20 mm thick.
Three coat of approved snowcem shall be done on exposed surface of intake well and pump house. All railing and wood work or steel works shall be painted with one coat of approved primer and two coats of approved with colour paint. The ladders/ railings of intake well shall be painted with anticorrosive paint. Two coats and over two coats of enamel paint, Inside the pump house one coat whitewash and two coats of dry distemper, three coats of whitewash on ceiling shall be done as per instruction of Engineer –in- Charge.
Rates per meter variation in height / depth of intake well shaft on either side.
Per meter increases
Per meter decreases
Rates per meter variation in Length of R.C.C foot bridge on either side.
Per meter increases
Per meter increases
Rates per 0.5 T/m2 variation in bearing capacity of soil
Per 0.5 T/m2 increases in BC
Per 0.5 T/m2 decreases in BC
Supply of all materials, labour, T&P etc Complete & Construction of Pump House as per deptt design & drawing in FPS Bricks 7.00 x 5.00 x 5.00 m in size including supply of all labour material T&P etc complete as per approved designed & drawing including all neceassary arrangements required for installation of motor & Pumps.
At M P S ( size 7.0x5.0x4.5 )m
At IPS ( size 7.0x5.0x4.5 )m
Excavation of earth for pipeline in following strata lift upto 1.5 m lead upto 30 m including refilling, watering, ramming of excavated earth into the trenches and removal of surplus earth upto a distance of 60 m from trenches including supply of labour, T & P etc.all complete.
Soil mixed with boulder(SMB)
Medium Rock(MR)
Exacavation earth mixed shingle & boulder for foundation including lift upto 1.5m (5ft) and lead upto 30 m(100ft) filling, watering and ramming of excavated earth in to the trenches or into the space between the building and the sides of foundation trenches or into the plinth & removal & disposal of surplus earth upto a distance of 60m (200ft) from the foundation trenches.(For Building Works.)
Providing of all materials, Carting from site store to site of work, Lowering into trenches with true to alignment, Laying of API-5L, Jointing by electric welding process with proper grade of eletrodes suitable for jointing of water supply pipe lines (Ador, L&T or equivalent electrodes) by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc complete.
From Intake Well-1 to MPS API Pipe 80 mm Dia 4.0 mm Thickness
From I.Well to I.P.S API Pipe 80 mm Dia 4.4 mm Thickness
From IPS toTOP CWR API Pipe 65 mm Dia 4.0 mm Thickness
Survey, design, supply carting, laying & jointing of G.I.(M) class pipe by socketing for Feeder Main/Distribution System of following sizes including provision of specials and other appurtenant works such as scouring arrangement at suitable locations by fixing tee etc. complete and also testing & commissioning of laid pipeline including supply of all materials, labour, T&P etc. complete. G.I. (Medium Quality).
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
65 mm dia
Supply, cartage upto site of work & fixing of following fittings including F.O.R. destination and taxes and insurance etc. complete as per direction of Engineer-In-Charge.
Wheel Valve ( Brass) /G.M. Valve
20mm dia
25mm dia
32mm dia
65mm dia
Supply & fixing of following sizes of valves including carting the same up to side of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect
Cast steel sluice valve WP-30Kg /cm2
80 mm dia
65 mm dia
Cast steel Check/Reflux valve WP-30Kg /cm2
80 mm dia
65 mm dia
Supply, cartage and fixing of C.I. Double acting type Air valves 80 mm dia, including supply of all labour, material, T&P etc.complete.
Suppy of all labour,material, T&P. ect. complete for construction of following type of chambers as per departmental type design and drawing with FPS Bricks.
Supply of all materials, labour, T & P etc. and Construction of size Sluice Valve / Reflux Valve / Scour Valve Chamber as per type design complete(1.2x1.2x1.2)m
Supply of all materials, labour, T & P etc. and Construction of size Air Valve Chamber as per type design complete(1.2x1.2x1.2)m
Supply of all materials, labour, T&P etc. and construction of 0.6 m x 0.6 m x 0.6 m size Gate Valve chamber with FPS bricks
Supply of all materials, labour and T & P etc. and construction of B P T as per type design and drawing including fixing of pipes and fittings including cartage of materials etc. complete
Supply of all materials, labour, T & P etc. and Construction of R.C.C Anchor Block @ 30 m interval as per type design complete
Making 2 M wide Briddle Path for rising main including hill side cutting and coolie walling of all materials, labour, T&P etc.
Making ferrule connection in the existing main of G.I. or any type of pressure mains with saddle piece, service connections, fittings and fixing of G.M. ferrule including tapping the main, but excluding the cost of earth work and cost of all materials.
Ferrule Connection (Labour cost only including index)
Providing and fixing brass bib cock of approved quality
Providing brass ferrule of approved quality
Providing G.I. tee of approved quality
Providing G.I. union of approved quality
Providing brass nipple of approved quality
Random rubble stone masonry in 1:6 cement and local sand mortar for protection work on pipe line, treatment site & where ever required as per site requirement including supply of all materials T&P etc required for proper completion of work as per direction of Engineer-In-Charge.
RR stone masonary laid in dry for protection work on pipe line,where ever required including supply of all material labour T&P etc for completion of work as per direction of Engineer-In-Charge.
Providing & laying PCC 1:2:4 in cement, coarse sand and 20 mm gauge approved stone ballast, including supply of all materials, labour , T&P etc required for construction of Thrust Blocks and other works as per site requirement and direction of Engineer-In-Charge.
Construction of boundary wall 1.50 m height above plinth level where ever required as per departmental type design & drawing including supply of all labour material T&P etc complete.
Supply of all labour, material, shuttering, centering, T&P etc. and construct semi sunk RCC circular clear water sump/reservoir on raft foundation as seismic proof design shall be accepted. The safe bearing capacity of soil is 8t/m2. The free board in the reservoir shall be kept 200 mm.
Clear Water Sump 90.0KL Capacity at MPS
Clear Water Sump 90.0 KL Capacity at IPS
Clear Water Sump 50 KL Capacity at TOP CWR
RCC CWR 2.0 KL
RCC CWR 4.0 KL
RCC CWR 7.5 KL
RCC CWR 10.0 KL
RCC CWR 12.50 KL
RCC CWR 17.5 KL
RCC CWR 30 KL
Supply and fixing of Bucket type chlorinator of 25 Liter capacity at top of all service reservoirs.
Design, Supply of all materials, labour, T&P. etc to construct a water treatment plant (WTP) to treat 0.35 MLD water (Source at Kho river near matiyali dugadda) based on rapid gravity filtration. The design of filter plant has to be done on the based on CPHEEO manual for Water Supply and Treatment. The filter plant should consists of inlet chamber, flow measuring device, presettling tanks (1 units), mixing units, flocculation unit, secondary settling tank (1 units), rapid gravity filter (minimum 2 filter beds), clear water chamber including all piping, valves, RCC 25KL back wash tank, double storey building (minimum 30 sqm) one floor will be used for office and other floor will be used for chemical room). Each floor height should be minimum 3.30 m. The work also include 60 cm apron and 15 cm semicircular PC drain all around all units and including overall drainage of water treatment campus upto outside 5 m of campus boundary. The work should also include internal electrification of all units as well as external electrification as per requirement of site. The work also include 1 m inter connecting RCC/CC path ways to all units as per site requirement. The work also include necessary excavation as per requirement and development of water treatment plant and disposal of surplus earth from site of work to suitable available place but excluding the cost of protection works, boundary wall and gates, which will be executed separately as per approved layout and design of treatment plant. The contractor is advised to inspect the site of work. No excuse and request to change the site, rates and demand of extra rates will be entertained at later stage.
Painting of API Pipes with 2 coats of approved quality. (Anti-Corrosive paint over one coat of Primer) (Dia of pipe in mm)
80 mm dia
65 mm dia
Supply of all materials, labour and T & P etc. and construction of Staff quarter for Chaukidar as per type design and drawings at Top Cwr.
Provision of Iron Gate with Pillars of following sizes complete
3.6 m wide
Provision of Drainage System consisting of following works
Manhole chambers
Supply & laying of drainage 250 mm dia. RCC NP2 pipe
Supply of all materials and construct 150 mm S.C. drain including supply of all labour T&P etc complete
Provision of Barbed Wire Fencing through angle iron posts around the water works site
INTAKE WELL - Electric driven V.T. Pump suitable to operate in raw water ( 350 LPM Discharge 30 meter 1450 rpm )
VHS electric motor suitable to run above pump.
Fully automatic A.T.S oil cooled starter suitable for above motors.
Control Panel as per site reqirement
Supply of 1x3x10 sq.mm submersible flat copper cable
1x3.5x35 sq.mm Aluminum armoured cable for power connection.
Jointing materials
Double loop earthing as per site rquirement
Supply of main piping & valves as per site reqirement
pressure gauge as per site requirement
Tools as per site requirement
2 Tone, 25 Mt. Lift capacity chain pulley block with travelling arrangements complete.
Rubber resistance sheet of size 1m x 2m x 0.025m
Painting
Installation,Testing & Commissioning of above Pumping Plants .
Testing of Pumps at manufacturer works
Cartage of Pumping Plants
MPS- Centrifugal pumps (300 LPM discharge at 460 Mts. head.)
electric motor suitable to run above pump
Base Plate
Starter
Control Panel as per site reqirement
150 mm² 3½ core Al Conductor Armoured cable of 1.1 KV grade.
25 mm² 3 core, Cu Submersible cable 1.1 KV grade.
Jointing materials.
Complete double loop earthing as per site requirement
Supply of main piping & valves as per site requirement
pressure gauge as per site requirement
Tools as per site requirement
HOT Crane as per site requirement
Rubber resistance sheet of size 1m x 2m x 0.025m
Painting
Installation,Testing & Commissioning of above Pumping Plants .
Testing of Pumps at manufacturer works
Cartage of Pumping Plants
IPS- Centrifugal pumps (250 LPM discharge at 155 Mts. head.)
electric motor suitable to run above pump
Base Plate
Starter
Control Panel as per site reqirement
50 mm² 3½ core Al Conductor Armoured cable of 1.1 KV grade.
16 mm² 3 core, Cu Submersible cable 1.1 KV grade.
Jointing materials
Double loop earthing as per site rquirement
Supply of main piping & valves as per site requirement
pressure gauge as per site requirement
Tools as per site requirement
2 Tone, 4 Mt. Lift capacity chain pulley block with travelling arrangements complete.
Rubber resistance sheet of size 1m x 2m x 0.025m
Painting
Installation,Testing & Commissioning of above Pumping Plants .
Testing of Pumps at manufacturer works
Cartage of Pumping Plants
Transformer as per site requirement 160 KVA
Internal & external electrification of pump houses
H.T Panel
Double loop earthing of Transformer as per site rquirement
HT cable Jointing kit outdoor type / Indoor type
Supply of XLPE,3 Core, 70 mm sq. H.T. alumuniam armoured cable
Cost of fencing of transformer
Automation -GSM based RTU
GSM based wireless communication hardware for RTU’s.
Intelligent Energy meters
Valve Actuator for 80 mm dia valve.
Actuator Panel
Hard wired timer circuit for actuator
Pressure Transmitter
Level transmitter of 10 mt range
Isolation Transformer
Over voltage and under voltage trip protection
Electromagnetic Flow meter for line sizes of 80 mm NB size
2 Core x 1.5 sqmm PVC coated flexible screened cable.
4 C x 1.5 sq mm PVC coated flexible unscreened Cu cable.
10C x 1.5 sq mm PVC coated flexible unsreened Cu cable.
Conduit pipe 1” PVC
Conduit pipe 1.5” PVC
Accessories
Erection commissioning of all instruments and customization of software.
O&M- After testing & commissioning of scheme running & maintenance of scheme by running pumping plant for 8 hrs per day (for a period of 6 months or complete Distribution line testing of civil works which over later ) including supply of skilled O&M staff, account maintenance including supply of all materials, labour, T&P etc. complete but excluding electricity charges for pumping of water.
SAKLA NAND LAKHERA
R K ENGINEERS SALES LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .