| 1 | L1₹7.5 LAccepted-AOC 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹7.5 L+₹2,999 (0.40%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance Rejected_Fin | |
| 3 | L3₹7.5 L+₹6,185 (0.83%)Rejected-Finance A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance Rejected_Fin | |
| 4 | Rejected-Technical 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | - | Rejected-Technical Rejected_Technical |
Tender Value
₹7.5 L
EMD Value
₹15,011
Closing Date
29 Jul 2024, 2:00 pmClosed
O/O Exe. Engr, Kolkta South Health El. Divn, PWDte
75 Diamond Harbour Road
Repairing the existing dilapidated Air Conditioning machines with allied electrical installation at Division Office under Kolkata South Health Electrical Division P.W.Dte. with allied works at Khidirpore 75 D H Road Kolkata700023
2024_WBPWD_714968_1
WBPWD/EE-I/KSHED/Q29/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
75 Diamond Harbour Road
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,011
O/O Exe. Engr, Kolkta South Health El. Divn, PWDte
4 Apr 2025
16 Jul 2024
31 Jul 2024
16 Jul 2024
29 Jul 2024
22 Jul 2024
22 Jul 2024
Amount
Dismantling & Refixing the existing damaged, switch board, wiring, dressing the cable, fittings & fixture as required very carefully & carrying the same to safe place as per direction of EIC.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/KEI/Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
(i) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing of Twin LED Tube light fitting omplete with 2x 18/20 Watt tube lamp (LED ) 2100 lm[Make - Philips cat no. TMC 501 P 2x T-LED, Master LED tube model no.18W 865 T8 I/ Crompton, cat no.IGP161 LT8-16, Tube - 2XLTT8-20]suspended below the ceiling with S&F 2x20mm dia EI conduit up to 25 cm long with 'L' type MS clamp and making connection as to GS.
S/F of 1200mm sweep AC ceiling fan complete with all accessories without regulator with Star rating -5(Make Crompton HS+ or HB+/ Usha striker plus)including engraving & painting departmental fan number on the body(upto 12 letters) with S/F dia down rod &making connection with 3 x 1.5 sqmm copper wire (Finolex/RR Kabel/Havells) as per the direction of E.I.C
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
(i) 100 A FP MCB
(ii) 40 A DP MCB
(iii) 6-32 A SP MCB
Supplying & fixing of PVC cable end loop box of size (140 x 140 x 95 mm) including providing drilled holes incl all necessary items as required for the input power of ODU of AC System. (Make: Syntex)
Supply & Fixing of MCB Mounting CHANNEL WHITE – Din 35 Rail (35 x 7.5 x 0.8 mm) White plated in the existing PVC loop box including providing drilled holes incl all necessary items as required for the fixing of MCB Isolator.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
4 x 126/0.4 (16 sqmm)
4 x 80/0.4 (10 sqmm)
2 x 84/0.3 (6 sqmm)
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for 8 way TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
For 4 core 25 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
For 4 core 25 sqmm
Finishing the end of following sizes copper wire end / PVC cable/Al. with dowells solderless socket by crimping method as pre GS as follows :-
a) 4 sqmm
b) 6 sqmm
c) 10 sqmm
d) 16 sqmm
Supply & Delivery split Air Conditioner machine 2TR capacity star Rating 3 power supply Ph-Hz-V,(1-50-230) running current Amper (8.1) Standard cooling at 100% capacity W (7.050) Power Consumpition at 100% capacity W (1850) Rated ISEER Kwh/Kwh (3.81) Electrical Consumition per Amum Kwh (1432) Moisture Removel I/h (1.92) indoor Fan Speed control Levels (6) indoor Airflow volume-Powerful m3/h ( 1450 ) Indoor Airflow Distance m (15) Indoor Noise Level-Quiet dB(A) 44 Ambient Operating Temperature Range *C (18 *C - 52*C ) Refrigerant Type ( R410A / R32 ) Compressor Type ( Hyper Tropical Rotary )
Supply & Delivery split Air Conditioner machine 1.1TR capacity star Rating 3 power supply Ph-Hz-V,(1-50-230) running current Amper (4.6) Standard cooling at 100% capacity W (4.000) Power Consumpition at 100% capacity W (1020) Rated ISEER Kwh/Kwh (3.92) Electrical Consumition per Amum Kwh (790) Moisture Removel I/h (0.17) indoor Fan Speed control Levels (6) indoor Airflow volume-Powerful m3/h ( 1100 ) Indoor Airflow Distance m (10) Indoor Noise Level-Quiet dB(A) 41 Ambient Operating Temperature Range *C (18 *C - 52*C ) Refrigerant Type ( R410A / R32 ) Compressor Type ( Hyper Tropical Rotary )
Supply & Delivery Ductable Air Conditioner machine 2TR capacity power supply Ph-Hz-V,(1-50-230) running current Amper (11.3) Rated ISEER Kwh/Kwh (2.71) Moisture Removal I/h (2.5) Indoor Airflow volume-Powerful m3/h ( 1100 )Ambient Operating Temperature Range *C (18 *C - 52*C ) Refrigerant Type ( R410A / R32 ) Compressor Type ( Hyper Tropical Rotary )
Installation of Split Inverter A.C 1TR.& 2TR. both indoor/outdoor Unit Incl. supply & fixing of outdoor mounting bracket & mending good the damages.
Installation of Ductable A.C both indoor/outdoor Unit Incl. supply & fixing of outdoor mounting bracket & mending good the damages.
Supplying & laying Copper Refrigeration pipe line for liquid and suction with insulation 9mm.thickness nitrill rubber line with fittings, elbows, bends, supports & brackets (Make-Ryoku)
a) Suction Line 15.88
b) Liquid Line 6.35
Supplying & laying Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex)
a) 4 core 2.5 sq.mm communication cable
b) 3 core 2.5 sq.mm communication cable
Copper Refrigeration pipe line for liquid and suction with insulation 9mm. thickness nitrill rubber line with fittings, elbows, bends, supports & brackets (Make-Ryoku)
a) Suction Line 12.70
b) Liquid Line 6.35
Supplying & laying Control copper Cabling from Condensing Unit to control panel (Make: polycab/finolex)
a) 4 core 2.5 sq.mm communication cable
b) 3 core 2.5 sq.mm communication cable
Supplying & laying 32/25 mm.NB Rigid PVC pipe (Schhedule-40) with 9 mm. thick Nitrile Rubber Insulation for AHU Drain Pipe up to nearest drain point
Dismantelling of Split Air Conditions Machine as per direction of EIC.
Re-installtion Charges for AC Machines as per direction of EIC.
Supply & charging of extra R-32/R-410A Gas as per requirement.
Pressure testing the system by Dry nitrogen and commissioning the AC system of 1.5 TR. Machine
Civil work for wall cutting mantation a good condition as per direction of EIC.
TERMS & CONDITIONS :- The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability Period 1 (One) year
Make & model of each and every material to be approved by EIC
SKY DECORATIONS PRIVATE LIMITED
MAXCOOL REFRIGERATION CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .