Loading…
Loading…
Tender Value
₹61.6 L
EMD Value
₹1.2 L
Closing Date
14 May 2025, 10:30 pmClosed
Bengaluru Development Authority
Annual Maintenance of electrical accessories, Air conditioners, Borewells, DG Sets at BDA Head Office Blocks (A,B,C,D&E), BDA Shopping Complexes and BDA Quatrers, Bangalore for FY 2025-26.
BDA/2025-26/EL/WORK_INDENT115
BDA/2025-26/EL/WORK_INDENT115
Open
Electrical
Two Tender Document System(Two Cover)
BDA Electrical Division
₹1,550
₹1.2 L
7 May 2025
7 May 2025
15 May 2025
9 May 2025
9 May 2025
Annual Maintenance of electrical accessories, Air conditioners, Borewells, DG Sets at BDA Head Office Blocks (A,B,C,D&E), BDA Shopping Complexes and BDA Quatrers, Bangalore for FY 2025-26.
Open Conduit SystemSupplying heavy guage PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends junction boxes adhesive pasteetcf and fixing using inverted wood plugs in c...
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends screws at an interval of 300mm Etc as required As per KPWD Electrical specification and di...
Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing pvc Conduit casing caping using copper PVC insulated multistrand 2x1 5 Sqmm copper wire a 6amps flush...
Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing pvc Conduit casing caping using copper PVC insulated multistrand 2x1 5 Sqmm copper wire a 6amps flush...
Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing pvc Conduit casing caping using copper PVC insulated multistrand 2x1 5 Sqmm copper wire a 6amps flush...
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends screws at an interval of 300mm As per KPWD Electrical specification and direction of the e...
Maintenance and Replacement of lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper with low conductor resistance single core wire in open or concealed system of ...
Maintenance and Replacement of lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper with low conductor resistance single core wire in open or concealed system of ...
Maintenance and Replacement of lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper with low conductor resistance single core wire in open or concealed system of ...
Maintenance and Replacement of lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper with low conductor resistance single core wire in open or concealed system of ...
Maintenance and Replacement of lighting power circuit using one of FRLS PVC insulated 1100v grade multistrand Copper with low conductor resistance single core wire in open or concealed system of ...
Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C C wall includingnecessary rawl plugs Machine NF s...
Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C C wall includingnecessary rawl plugs Machine NF s...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing met...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws bolts nuts etc complete on the existing met...
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 As per KPWD Electrical specification and direction of the engineer in c...
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854and IS 1293 6Amps 3way socket As per KPWD Electrical specification and direction of...
Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293 As per KPWD Electrical specification and direction of the engineer in c...
Maintenance and replacement of 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc and fixing wooden or metal box using N F screws As per KPWD Electrical specificati...
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work a 6Amps SP Switch
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work b 6Amps 2 way Sw...
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work c 6Amps 3 way 5 pi...
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work d 6Amps 3 pin top
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work e 6 Amps bell push
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work f 16 Amps SP Switc...
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work i 16 Amps 3 way 5...
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work j 16 Amps 3 pin to...
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work k 32 Amps bakelit...
Supplying and fixing replacing of 6 16 32 amps electrical acessories on existing switch board As per KPWD Electrical specification and direction of the engineer in charge of work m 16 6 Amps combin...
Replacement of porcelain fuse channel with cut out on existing wooden panel using necessary nuts bolts and washers etc complete As per KPWD Electrical specification and direction of the engineer in...
Supply and fixing of 4pole power contactor with NO NC contacts on existing wood panel board using necessary bolts nuts washers and wiring etc complete with AC 3 Rating and as per IS 13947 As per ...
Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood panel board using necessary screws bolts nuts and wiring complete Protection of Overload and Short circuit with thermal...
Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood panel board using necessary screws bolts nuts and wiring complete Protection of Overload and Short circuit with thermal...
Maintenance and Replacement of minature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON OFF energy cross 3 with Short circuit b...
Maintenance and Replacement of minature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON OFF energy cross 3 with Short circuit b...
Supplying fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel wood board As per KPWD Electrical specification and direction of the engineer in charge of work
Supplying fixing and wiring 0 to 30A Direct Reading AC analog type Ammeter As per KPWD Electrical specification and direction of the engineer in charge of work
Supplying fixing and wiring rotary selector switch suitable for Ammeter As per KPWD Electrical specification and direction of the engineer in charge of work
Supplying fixing and wiring rotary selector switch suitable for Voltmeter As per KPWD Electrical specification and direction of the engineer in charge of work
Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic FRP DMC insulator which are ...
Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve mounted on phenolic FRP DMC insulator which are ...
Supplying and fixing angle iron frame work fabricated out of M S angle iron And M S flat with bolts washers etc and painted with 2 coats of red oxide and then two coats of approved paint As per K...
Supplying and fixing angle iron frame work fabricated out of M S angle iron And M S flat with bolts washers etc and painted with 2 coats of red oxide and then two coats of approved paint As per ...
Fabricating supplying and mounting MS box made out 14 WG suitable for floor wall mounting fully weather proof with provision for better heat dissipation provided with hinged front cover equipped with...
Supplying capacitor type ceiling fan complete with down rod blades shackle canopies etc for operation on 230 volts 50 cycles Single phase AC supply conforming to ISS 374 1979 and with double ball b...
Supplying wall mounting fan suitable to operate at single phase 230v A C supply As per KPWD Electrical specification and direction of the engineer in charge of work 400mm sweep
Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 percent lumen maintenance with CRI greater than 80 Power Input220 240V at...
Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percentlumen maintenance with CRI greater than80 Power Input220 240V at t...
Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRI greater than 70 percent efficacy greater than 80 lumen per watt life...
Maintenance and Replacement of condenser for ceiling fan MV SV MH and other luminaries As per KPWD Electrical specification and direction of the engineer in charge of work
Supplying and fixing replacing of fluorescent tube As per KPWD Electrical specification and direction of the engineer in charge of work 18 to 40 watts
Supplying and fixing replacing of fluorescent tube As per KPWD Electrical specification and direction of the engineer in charge of work 18 to 40 watts
Supply and fixing one of 230 volts Ding Dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws As per KPWD Electrical specification and direction o...
Rewinding a 1400mm ceiling fan after using necessary gauge annealed and insulated copper wire necessary insulating separators vibration arresting shellac etc including replacement of bearing if any tr...
Releasing the existing fan dismantling testing painting after removing the existing painting by scraping and cleaning spray method not less than 2 coats of approved make enamel paint to a ceiling f...
Supplying and replacing ceiling fan regulator 900mm to 1500mm As per KPWD Electrical specification and direction of the engineer in charge of work
Supplying and fixing replacement of heating element for Geyser Boiler 3KW Capacity As per KPWD Electrical specification and direction of the engineer in charge of work
Supplying and fixing replacement of pressure relief valve suitable for Geyser As per KPWD Electrical specification and direction of the engineer in charge of work
Painting of existing street light pole after scrapping the old paint and painted with suitable colour enamel Silver paint including coping footing of the pole As per KPWD Electrical specification an...
Fixing a ceiling Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing a 5 amperes ceiling rose necessary...
Transformer Repairs ScopeRepairs and Reconditioning of 11KV class single coil multi coil Conventional Aluminium wound and 3 4 5 Star Rated failed Distribution Transformers of various Capacities and ...
Erection of Transformer and Structures After repaired As per BESCOM specification and direction of the engineer in charge of work
Providing labour service for Hiring of crane for erection of 250 500 kVA Transformer applicable for maintenance works only and in case of non availability of departmental crane As per BESCOM specif...
Providing labour service for Loading and Unloading of Transformer As per BESCOM specification and direction of the engineer in charge of work
Providing labour service for Fixing 1 Circuit of LT Wiring for 250 500 kVA Transformers via metering box includes fixing of necessary supports like 2 Pin cross arm Spacer etc As per BESCOM specifi...
Providing Silica Gel As per BESCOM specification and direction of the engineer in charge of work
Supplying Rabbit ACSR Conductor As per BESCOM specification and direction of the engineer in charge of work
Providing Transparent Alkathine tube 19 mm dia 2 mm thick in coils of 30 Mtr As per BESCOM specification and direction of the engineer in charge of work
Providing Rod type of earthing using 40mm dia 3mtr long MS rod as ground rod in earth pit of 300mm width and 3300mm depth and using 50x6mm flat welded to ground rod as terminal and connected to equi...
Providing Bentonite clay slurry for earthing in 50 Kg Bag As per BESCOM specification and direction of the engineer in charge of work
Providing GI Grounding pipe B Class 42 mm dia 2 point 5 Mtr long 3 point 2 mm thick with bolt nut GI Strips and washer complete Minimum Weight of GI Pipe7 3 Kg As per BESCOM specification and direct...
Providing Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each As per BESCOM specification and direction of the engineer in charge of work
Providing Good Quality Salt for grounding purposes packed in 50 Kg gunny bag As per BESCOM specification and direction of the engineer in charge of work
Supplying of 9 kV 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR As per BESCOM specification and direction of the engineer in charge of work
Fixing of 3 Nos Lightning Arrestor including wiring As per BESCOM specification and direction of the engineer in charge of work
Supply of 11 kV 400 Amps Double Break GOS As per BESCOM specification and direction of the engineer in charge of work
Providing Labour service for fixing of GOS including wiring 11 kV Single Break 200 Amps As per BESCOM specification and direction of the engineer in charge of work
Supply and Fixing 200 Amp Male GOS Contact Copper As per BESCOM specification and direction of the engineer in charge of work
Supply and Fixing 200 Amp Female GOS Contact Copper As per BESCOM specification and direction of the engineer in charge of work
Supplying of 11 kV 5 KN Polymeric Pin Insulator 24 mm Dia FRP Rod There is no provision for Labour Cost As per BESCOM specification and direction of the engineer in charge of work
Supplying of 11 kV 45 KN Polymeric Insulator There is no provision for Labour Cost As per BESCOM specification and direction of the engineer in charge of work
Labour service for Releasing and Refixing Insulator of 11 kV Pin Insulator As per BESCOM specification and direction of the engineer in charge of work
Supplying of 1 1 kV Pin Insulator with GI Pin There is no provision for Labour Cost As per BESCOM specification and direction of the engineer in charge of work
Supplying of No 8 strain insulator There is no provision for Labour Cost As per BESCOM specification and direction of the engineer in charge of work
Supplying of Spiral Earth Electrode There is no provision for Labour Cost As per BESCOM specification and direction of the engineer in charge of work
Providing Labour service for making Spiral Earth Electrode connection As per BESCOM specification and direction of the engineer in charge of work
Supplying of 11 kV HG Fuse Unit with Solid Core Insulator Dwg No BESCOM GM QS and S 21 Dtd 24 11 2018 As per BESCOM specification and direction of the engineer in charge of work 1 Set 3 Nos
Supplying 1 1 kV XLPE or Heat resistant PVC insulated PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 Part 1 or IS 7098 Part 1 Armouring strip thickness and resistivity as per IS 3975...
Supplying 1 1 kV XLPE or Heat resistant PVC insulated PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 Part 1 or IS 7098 Part 1 Armouring strip thickness and resistivity as per IS 3975...
Earth work excavation for cable trench of 0 5 to 0 75 Mtr Width and Depth upto 1 Mtr including trial pits depositing on bank upto a lead of 50 Mtr Supplying and Displaying necessary Danger Boards and...
Providing Labour Service for laying of cable in Existing Trench GI pipe Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff As per BESCOM specification and dir...
Providing Labour Serice for laying of cable in Existing Trench GI pipe Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff As per BESCOM specification and dire...
Providing Labour Serice for laying of cable in Existing Trench GI pipe Stone Ware RCC Hume pipe using Wooden Aluminum Rollers as directed by the departmental staff As per BESCOM specification and dir...
Refilling the cable trenches with selected available earth from trench excavation including watering consolidation in layers of 15 cm Thickness including depositing of the surplus earth with a lead o...
Supplying and spreading 100mm thick with 20 25mm jelly with all lead and lifts As per BESCOM specification and direction of the engineer in charge of work
Supplying of PG Clamp Rabbit to Insulated Wire As per BESCOM specification and direction of the engineer in charge of work 95 Sqmm
Supplying of PG Clamp Rabbit to Insulated Wire As per BESCOM specification and direction of the engineer in charge of work 240 Sqmm
Supplying of Pad Clamp for Rabbit ACSR As per BESCOM specification and direction of the engineer in charge of work
Supplying of Epoxy Type Straight Through Jointing Kit Suitable for 1 1 kV Class LTUG Cable as per IS 13573 As per BESCOM specification and direction of the engineer in charge of work a 95 Sqmm 3 5 4...
Supplying and making of Epoxy Terminating Kit Pothead suitable for 1 1 kV LTUG Cable As per BESCOM specification and direction of the engineer in charge of work Up to 4CX50 Sqmm
Supply of Epoxy Terminating Kit Pothead suitable for 1 1 kV LTUG Cable 3 5 x 225 240 300 Sq mm As per BESCOM specification and direction of the engineer in charge of work
Supply of Epoxy Terminating Kit Pothead suitable for 1 1 kV LTUG Cable As per BESCOM specification and direction of the engineer in charge of work 3 5 x 70 95 120 Sqmm
Supplying of Transformer Oil as per IS 335 1993 EHV Grade Transformer Oil New As per BESCOM specification and direction of the engineer in charge of work
Supplying of Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x95 Sqmm As per BESCOM specification and direction of the engineer in charge of work
Supplying of Heat Shrinkable indoor type cable termination kit for XLPE cable As per BESCOM specification and direction of the engineer in charge of work 3x95 Sq mm
Supplying of Heat Shrinkable Out door type cable termination kit for XLPE cable As per BESCOM specification and direction of the engineer in charge of work 3x95 Sq mm
Making of Heat Shrinkable cable termination kit for XLPE cable As per BESCOM specification and direction of the engineer in charge of work 3x95 Sq mm
Supplying installing testing and commissioning of Diesel Generator set with following specifications Power rating as per standard reference condition asper BS5514 ISO3046 ISO8528 and IS 1002 ISO 30...
Supply Erection testing and commissioning of AMF panel suitable for kVA DG set The panel is of cubical type base floor mounting control panel with hinged doors undrilled bottom gland plate alumi...
Supplying fixing and wiring earth electrode for grounding of lifts transformers DG sets etc using 40mm dia 2 9mm thick 2 5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on...
Providing and Fixing GI pipes conforming to IS 1239:1990with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary including testing for...
Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130 1984 and virgi...
Repaire and Mainatainance of 160KVA DG set includes carrying the out monthly regular maintainance along with quaterly schedule maintainance servicing of control circuit reconditioning of starter motor...
Repaire and Mainatainance of AMF Panel of 160KVA DG set includes checking the healthiness of the control contacts circuits and connections carrying the out monthly regular maintainance along with quat...
Repaire and Mainatainance of 1 TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser motor capacitor and...
Repaire and Mainatainance of 1 5 TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser motor capacitor a...
Repaire and Mainatainance of 2 TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser motor capacitor and...
Repaire and Mainatainance of 3 0TR Slimline Air Conditioner in Complete direction of the engineer in charge of work
Repaire and Mainatainance of 2 0TR Window type Air Conditioner Location in Complete direction of the engineer in charge of work
Repaire and Mainatainance of 2 0TR Window Air Conditioner in Complete direction of the engineer in charge of work
Repaire and Mainatainance of submercible motor pump starter unit includes lifting of motor pumps accopanied with the submercible cable rewinding replacing the worn out spare parts in the motor pumps ...
Repaire and Mainatainance of submercible motor pump starter unit includes lifting of motor pumps accopanied with the submercible cable rewinding replacing the worn out spare parts in the motor pumps ...
Repaire and Mainatainance of submercible motor pump starter unit includes lifting of motor pumps accopanied with the submercible cable rewinding replacing the worn out spare parts in the motor pumps ...
Repaire and Mainatainance of submercible motor pump starter unit includes lifting of motor pumps accopanied with the submercible cable rewinding replacing the worn out spare parts in the motor pumps ...
Repaire and Mainatainance of MANOBLOCK Pump set starter unit includes lifting of pump set accopanied with the cable rewinding in the case of winding burnt out replacing the worn out spare parts in ...
Repaire and Mainatainance of MANOBLOCK Pump set starter unit includes lifting of pump set accopanied with the cable rewinding in the case of winding burnt out replacing the worn out spare parts in ...
Annual repaire and maintainance of 250MH Street lights fixture in Complete direction of the engineer in charge of work
Annual repaire and maintainance of UPS Complete direction of the engineer in charge of work
Annual Recharge of TATA SKY Dish Platinum south HD package above offices 1 Chairman Office ID No 1160614168 2 Commissioner Office ID no 1205756131 3 Finance Member Office ID No 1181781087 Engineer ...
Providing Distribution Panel with all required accessories in Complete direction of the engineer in charge of work
Supply and fixing with testing and commissioning of 20 KW UPS and Batteries Complete direction of the engineer in charge of work
Supply and fixing of Exhaust Support Structure Complete direction of the engineer in charge of work
Supply and installation of 10 inch MS ERW 5mm thick Pipe including flanges and hardware etc Complete direction of the engineer in charge of work
MS ERW 90 Degree bend 10 inch Complete direction of the engineer in charge of work
Supply and Installation of Insulation for above exhaust pipe with 50 mm thk Rockwool slab of 64 Kg M3 wrapped with 24 gauge Aluminium sheet Complete direction of the engineer in charge of work
Supply and installation of 6 inch MS ERW 5mm thick Pipe including flanges and hardware etc Complete direction of the engineer in charge of work
Supply and Installation of Insulation for above exhaust pipe with 50 mm thk Rockwool slab of 64 Kg M3 wrapped with 24 gauge Aluminium sheet Complete direction of the engineer in charge of work
Providing a Electriation Service at BDA Head Quarters and CopmlexesUnit is the Basic rate +ESI+EPF Complete as per the Direction of the Engineer incharge of work
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .