| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 26 8 2 PUNE MUMBAI ROAD OPP B U BHANDARI SHOWROOM EKTA PARK SOCIETY WAKDEWADI PUNE 411 003 | PUNE | MAHARASHTRA | 411003 | ₹1.1 Cr | L1 | Accepted-AOC being lowest |
| 2 | L2₹1.1 Cr+₹88,859.50 (0.79%)Rejected-Finance | ₹1.1 Cr+₹88,859.50 (0.79%) | L2 | Rejected-Finance Rejected being not lowest |
| 3 | L3₹1.3 Cr+₹18.5 L (16.4%)Rejected-Finance | ₹1.3 Cr+₹18.5 L (16.4%) | L3 | Rejected-Finance Rejected being not lowest |
| 4 | L4₹1.4 Cr+₹25.3 L (22.5%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹1.4 Cr+₹25.3 L (22.5%) | L4 | Rejected-Finance Rejected being not lowest |
| 5 | Rejected-Technical 05 AYODHYA NAGAR NEAR RAM MANDIR BEHIND HARIYA COLLEGE GOKUL NAGAR JAMNAGAR 361004 | JAMNAGAR | JAMNAGAR | GUJARAT | 361004 | - | - | Rejected-Technical Two class below eligible class |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
8 Jul 2023, 6:00 pmClosed
CE NW Kochi
MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH KOCHI 682004
ADDN ALTN AND SPECIAL REPAIRS TO BLDG NO P459 AND P 460 AT DFO COMPLEX AND P 153 COMMA P 153A OF HQ 31 WEU 2M DET JAMNAGAR
2023_MES_597387_1
891044
Open Tender
Civil Works
Item Rate
240 days
JAMNAGAR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE (I) NAVY JAMNAGAR
₹2.0 L
Yes
9 Aug 2023
22 May 2023
10 Jul 2023
23 May 2023
8 Jul 2023
24 Jun 2023
Amount
SPECIAL REPAIRS (B/R)
Complete removal of old existing treatment of any thickness from RCC roof by stripping out old tar felt over roofs, parapets, chimney stacks etc as laid horizontally or vertically including taking out layer of cement plaster, china mosaic and PCC of any thickness over RCC roof surface if any completely by scrapping/scrubbing/brooming down etc and cleaning the surface and removing the debris to a distance not exc 250 mtr complete all as specified and directed.
15 mm thick rendering/screed in CM 1:4 on over RCC roof / concrete/ wall surfaces, mixed with liquid integral water proofing compound as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed.(Water proofing compound will not be paid separately).
Providing water proofing treatment over roof, chajjas etc by applying Fosroc Polyurea WPE or equivalent in other approved makes which consists of two main components; Fosroc Polyurea WPE Part A and Fosroc Polyurea WPE Part B. All surface must be clean dry and free from contamination. All blow holes and minor surface imperfections shall be filled with recommended filler prior to application of primer. Prepared surface shall be primed using Fosroc Nitoprime PA-FS on Fosroc primer 195 or equivalent in other approved makes. High pressure spray proportioning machine/spray gun for polyurea components shall be used for applications. Applied thickness of Fosroc polyurea or equivalent in other approved makes shall be 2 to 2.5mm. When lapping new polyurea WPE or equivalent in other approved makes to existing after 12 hours of laying the previous polyurea coating application, a Nitoprime 150 or equivalent in other approved makes wipe is required to be given and allowed to dry prior to fresh polyurea application. 40mm thick PCC 1:2:4 type Bo, surfaces finished even and smooth without using extra cement shall be laid over water proofing treatment. NOTE : Water proofing treatment work shall be executed by authorized applicator of the manufacturer and as per manufacturer specification and Methodolgy.
Cutting out cracks to "V" section in existing roofs or terrace, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
Demolition of cement concrete in ground floor or paving n.exc 15 cm thickness (above or below ground level) complete all as specified and as directed.
Demolition of Reinforced Cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
Taking down cement plaster or cement lime plaster on brick or stone wall, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
20mm thick rendering in two layers on stone masonry surfaces or other than fair faces of brickwork of walls consisting of first layer of 12mm thick plaster in CM 1:6 and second layer (setting coat or top layer) of 8mm thick plaster in CM 1:4, second layer mixed with integral liquid water proofing compound as per manufacturer's instructions, finished fair and even without using extra cement complete all as specified ( Note : Supply only integral liquid water proofing compound shall be measured and paid for separetely).
Supplying only liquid integral water proofing compound
Rendering 15 mm thick on masonry or concrete surfaces with cement plaster in cement mortar 1:6 and finished smooth and even without using extra cement complete all as specified and as directed.
Rendering 10 mm thick on fair faces of concrete surfaces in ceilings in cement mortar 1:3 and finished fair and even without using extra cement complete all as specified and as directed.
Preparing old surfaces of ceilings by brooming down or by steel wire brushing and applying three coat of white wash complete all as specified and as directed.
Preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
Preparing newly plastered surface of wall and applying two coat of exterior emulsion paint over a coat of anti fungal primer over and including 1mm thick water proof wall care putty suitable for exterior surfaces exposed to weather complete all as specified and as directed. NOTE : Painting and priming shall be carried out using spray machines.
Complete removal of existing treatment and filling of undulation with 1mm thick water proof wall care putty suitable for exterior surfaces exposed to weather and applying two coats of exterior emulsion paint over a coat of anti fungal primer on old plastered surfaces of wall complete all as specified and directed. NOTE : Existing treatment shall be removed by using mechanical equipments like electric hand held sander and painting & priming shall be carried out using spray machines.
Preparing newly plastered surfaces of walls and applying 2 coats of oil bound distemper emulsion over a coat of priming with alkali resistant primer paint and over two coats of water proof wall care putty complete all as specified and as directed.
Complete removal of existing treatment on old surface of wall and applying 2 coats of oil bound distemper emulsion over and including two coats of water proof wall care putty on plastered surfaces complete all as specified and as directed.
Supply & Fixing in repairs of 20 mm dia Harrison rails, mild steel, chromium plated with fixing brackets, finials(Latto), stops, rollers etc. complete all as specified and as directed .
Taking down Chowkats or frames not exceeding 1.5 Sqm each (without taking off shutters from frames)
Taking down Chowkats or frames exceeding 1.5 Sqm and not exceeding 4 Sqm each (without taking off shutters from frames)
Taking down shutters of any description not exceeding 1 Sqm each.
Taking down shutters of any description exceeding 1. Sqm but not exceeding 2 Sqm each
Cutting holes in brick work built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement mortar 1:2:4 Type B-1 not exceeding half brick all as specified and directed
Mild steel hold fasts of flats iron conforming to Fe 410-O 0r Fe 310-O complete all as specified and as directed.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, one face is covered with decorative face veneer with lipping/frame to match, complete all as specified and directed.
35 mm thick Second class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides(feather edged) or veneered particle board medium density wood particle board with commercial face veneers as specified in SSR Part I, Section 8, clause 8.24 (a), supplied and fitted to chowkats complete all as specified and as directed.
35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed.
GI wire netting 0.9mm dia and 12mm meshlathing in walls, ceilings, stanchions, beams, etc, including all laps, cutting and waste, fixed with nails to receive plaster, complete all as specified and as directed.
4 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
5.5 mm thick Sheet glass, tinted and glazing with clips and rubber beading in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
4 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Solar control films 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed
Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of Pink primer complete all as specified and as directed. .
Preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of Synthetic enamel paint (Ordinary tint) over one coat of primer including complete removal of old treatment by using hot blower etc complete all as specified and as directed.
100 mm long stainless steel butt hinges with mild steel pin bright polished complete all as specified and as directed.
150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed.
150mm long Aluminium, anodised,handle cast type complete all as specified and as directed.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring for fixing in floor complete all as specified and as directed.
Supply & Fixing in repairs Floor door stopper of aluminium alloy body with hard drawn steel spring tongue, fixed in door complete all as specified and as directed.
300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and as directed.
Supply & Fixing in repairs 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and as directed.
Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
Supply & Fixing in repairs Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed
Fibre glass reinforced plastic (FRP) door frames of cross section 90mm x45mm having single rebete 32x15 mm to recive shutter of 30mm thickness . The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as specified by the manufacturer and as per directions of Engineer-in-Charge.
30mm thick Fibre glass reinforcedment plastic (FRP) panelled door shutter of required colour and approved brand and manufacturer, made with fire retardent grade unsaturated polyester resin moulded 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasiond wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer-in-Charge.
Mild steel work in framed work such as grills, gratings,framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe-290 Gde E-165 complete all as specified and as directed
S&F in repairs collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc. as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and as directed
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed
Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish out side MD land complete all as specified and as directed
Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,cutting and mirror polishing complete.with including 15 mm thick screed bed of CM (1:4) complete all as specified and as directed
All as per item No 54 here-in-before but 15 mm thick on vertical surfaces such as in skirting including 10 mm thick backing coat of CM (1:4) complete all as specified and as directed
Grinding and polishing on rubbing, cutting and mirror polishing existing kota stone flooring complete all as specified and as directed
Supply & Fixing in repairs 2 mm thick PVC tiles/sheets, laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors complete all as specified and directed.
Vitrified light shade tiles 10 mm thick (square/rectangular) polished, area of each tile exc 0.36 sqm but n exc 0.42 sqm, in floors including dismantling of old tiles etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All as per item No 58 here-in-before but in skirting/dado complete all as specified and directed.
15 mm thick screed bed or bedding layer in cement mortar 1:4, for laying floor finishes complete all as specified and directed.
10 mm thick rendering in cement mortar 1:4 on brick or concrete surfaces, for fixing of tiles as in dado/skirtings complete all as specified and directed
Rectified jointless glazed ceramic tiles coloured on vertical surface 600X300X8 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick backing coat of CM (1:3) complete all as specified and directed
Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
Rectified digital Joint free non skid Coloured ceramic tiles of 7 to 8 mm thick (Square/Rectangular) area of each tiles exceediing 0.18 Sqm but not exceeding 0.38 Sqm, each in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
All as per item No 64 here-in-before but fixed in wall dado/skirting etc .
Supply & Fixing in repairs Vitreous China Squatting pan 'orissa pattern size 580x440mm white with integral foot rests with `P' or `S' trap, front or back inlet including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including concrete complete including making good to floor complete all as specified and as directed
Supply & Fixing in repairs Vitreous ware wash down water closet (pedestal), white (EWC), complete all as specified and directed
Supply & Fixing in repairs only plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device, complete all as specified and directed
Supply & Fixing in repairs 10 litre capacity PVC low level flushing cistern white with inlet ball valve float handle flush pipe of polyethylene of low or high density of PVC , 32 mm dia including brackets and connections to pipe etc complete all as specified and as directed
Supply & Fixing in repairs Vitreous China Ware Wash hand basin white, counter sunk, oval shape as per CAT No.CNS-WHT-705 of Jaquar or equivalent as approved including fixing in platform complete all as specified and as directed
32 mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed to complete to wall , floor as in waste pipe of urinals , WHB etc complete all as specified and as directed
Supply & Fixing in repairs PVC connection of 15 mm bore and 450 mm long with brass checknut and union etc complete all as specified and as directed.
CP Brass Towel Ring , fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) complete all as specified and as directed
Brass Chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges complete all as specified and as directed
Supply & Fixing in repairs 15 mm bore Fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
Supply & Fixing in repairs15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
Supply & Fixing in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
Fancy type chromium plated with long shank and cup (concealed type) 15 mm bore Stop valves, for iron pipe or for unions complete all as specified and as directed.
Supply and fix in repairs sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 CM wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed.
Soap dispenser with Glass bottle and fixing brackets complete of Make Jaquar, Cat No AKP-35735P or equivalent in other approved makes complete all as specified and as directed
Soap dish,vitreous china white approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
Supply and Fixing in repairs Vitreous china urinal, bowl type flat back of size 395x360x930 mm white (minimum), with grating and union for discharge pipe complete all as specified and as directed
PVC (SWR) multi floor trap of 75 mm outlet plain with grating including jointing with solvent cement complete all as specified and as directed
Taking up or down 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed
Taking up or down 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed
Taking up or down 25 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed
15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed
20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed
25 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed
Supply and fixing in repairs 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron pipe complete all as specified and as directed
Supply and fixing in repairs 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe complete all as specified and as directed
Dismantling of CI/PVC or reinforced concrete drain pipes, joint in cement mortar, fixed to walls or taking out of trenches, complete all as specified and as directed
75 mm bore PVC (SWR) soil, waste, vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed
110 mm bore PVC (SWR) soil, waste, vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed
110 mm PVC (SWR) vent cowl complete all as specified and as directed
75 mm PVC (SWR) vent cowl complete all as specified and as directed
75 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal complete all as specified and as directed
75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed
110 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal complete all as specified and as directed
110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and as directed
(SWR) gully trap 125/110 mm ,setting and jointing with solvent cement complete all as specified and as directed
Dismantling of water tank (PVC) exc 500 n.exc 1000 Ltrs capacity complete all as specified and as directed
Disconnecting existing tanks, setting aside (or lowering if required) for repairs of water proofing treatment , cleaning, etc. and hoisting if required reconnecting and re-fixing in position (exc 250 ltr but not exc 500 ltr) complete all as specified and as directed
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), triple layer, hoisted and fixed in position all as specified in SSR Part I (cpacity 500 litres) complete all as specified and as directed
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), triple layer, hoisted and fixed in position all as specified in SSR Part I (cpacity 1000 litres) complete all as specified and as directed
Supply & Fixing in repairs ball brass valve 20 mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule etc complete all as specified and directed
100mm thick PCC (1:2:4) type B-2 using 40 mm graded stone aggregate finished even and smooth without using extra cement for water tank platform etc complete all as specified and as directed
75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing/ Plinth protection finishing the surface even and smooth including making groove and filling with bitumen mastic, complete even and smooth without using extra cement complete all as specified and as directed
18/19 mm thick one sides prelaminated Particle board, interior grade, fixed with screws to frame work in cup board shutters, partitions, shelves, wall cladding including 6mm thick teak wood lipping etccomplete all as specified and as directed
18/19 mm thick both sides prelaminated Particle board, interior grade, fixed with screws to frame work in cup board shutters, partitions, shelves including 6mm thick teak wood lipping etc complete all as specified and as directed
PVC(SWR) multi floor trap of 110mm dia outlet with gratings including jointing with solvent cement complete all as specified and as directed
Continuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 30 mm complete all as specified and as directed
Brass 4 lever locks, cupboard, grade I, size 50 mm complete all as specified and as directed
Brickwork with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed
Precast cement concrete masonry type C4 as per IS-2185 Part-I 2005 with solid blocks having minimum average compressive strength of 4 N/Sqmm and minimum strength of individual unit is 3.2N/Sqmm, 10cm in width and setting in CM 1:4 all as specified
Granite(of any type) tiles 20mm thick (table rubbed and polished) in steps,jambs,pillars,window cill,cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shed of granite complete all as specified and as directed
Rounding edge of stone slabs one edge such as in steps cooking platform and other similar situation complete all as specified and as directed
Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) for slabs supported on walls, beams and columns, in floors, roofs, landings,balconies,canopies,deck slabs and in shelves complete all as specified and as directed
Fair finished flat form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exceeding 200 mm thick complete all as specified and as directed
Reinforced Cement Concrete Type A1 1:1.5:3 (using 20 mm graded granite stone aggregate) in Roof Beams, cantilevers, lintels over 1.5 M span complete all as specified and as directed
Form work for flat rough finished surface of concrete,to sides and soffits of floor or roof beams,beam haunching,girders, bressumers,lintels, cantilevers, shelves including supports,over hangs etc also splays between floors and beams. complete all as specified and as directed
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed
Mild steel TMT 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for shaft,wells,cesspits,manholes pier holes etc not exc 10sqm on plan and not exc 1.5m in depth and getting out,in hard/dense soil complete all as specified and as directed
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar 150 mm dia complete all as specified and as directed
Cement concrete (1:3:6) type C2( using 40 mm graded stone aggregate) in foundations, filling and mass-concrete complete all as specified and as directed
Providing cement concrete (1:2:4) type B1(using 20mm graded stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones complete all as specified and as directed
Reinforced concrete pipe 150mm dia class NP-2, ISI marked, laid and jointed with collars complete all as specified and as directed
Providing precast cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in landing / cover slab etc setting in CM 1:6 complete all as specified and as directed
PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and as directed
PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in surface channel and drains, etc complete all as specified and as directed
Cutting into existing manhole 150mm dia for connecting new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate, smooth finished and reforming benching as required complete all as specified and as directed.
Returning filling in foundation/filling under floor including spreading, watering and well ramming in layer n.exc 25cm each in loose/soft soil complete all as specified and as directed
Removal of excavated materials soil exc 250 mtr but not exc 500 mtr deposited where directed at a level not exc 1.5m above the starting point complete all as specified and as directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles etc.complete all as specified and as directed
Chipping / dismantling of loose damaged concrete removed carefully by using mechanically concrete up to good parent concrete to expose the existing reinforcement (Direct hammering should be avoided) (avg thickness of 50-75 mm all round of lintel/ beams and the exposed surface shall be cleaned to remove any loose materials with wire brushes for further treatment like application of rust convertor (Rebaklens RR Fosroc/Conmix RR) . Apply epoxy - Phenolic based anti corrosive coating (BASF make Master Emaco P130/Nitrozinc Primer of Foserock/Recon Zinc of Conimix ) over the exposed reinforcement in two coats and allow the coating to cure in air for atleast eight hours before starting further treatment. The entire concrete surface shall be applied with concrete penetrating corrosion inhibitor solution.(EPCO KP 100 Krishna Conchem) on lintel / beam/slab etc. complete all as specified and as directed
M&L chipping / dismantling of loose damaged concrete removed carefully by using mechanically concrete up to good parent concrete to expose the existing reinforcement (Direct hammering should be avoided) (avg thickness of 75-100 mm allround of columns and the exposed surface shall be cleaned to remove any loose materials with wire brushes for further treatment like application of rust convertor (Rebaklens RR Fosroc/Conmix RR) . Apply epoxy - Phenolic based anti corrosive coating (BASF make Master Emaco P130/Nitrozinc Primer of Fosrock/Recon Zinc of Conimix ) over the exposed reinforcement in two coats and allow the coating to cure in air for atleast eight hours before starting further treatment. The entire concrete surface shall be applied with concrete penetrating corrosion inhibitor solution.(EPCO KP 100 Krishna Conchem) complete all as specified and as directed
Providing and fixing shear key using 10mm diameter TMT bars including drilling holes of 12mm diameter and 100 mm depth @ 300 mm spacing on all three sides of lintel/beams and providing TMT bars of same diameter of reinforcement where as reduced to less then 20% of original diameter including tack welding and grout the holes of shear key with two component epoxy resion based anchoring grout Master Flow 935 of BASF/LOK fix P of FOSROC by power gun etc complete all as specified and as directed
Providing , fixing and removing of water tight shuttering (Form work) using film coated 12 mm thick ply wood sheets for micro - concreteing the lintels/beams in line and level with proper support of avg thickness 50-75 mm complete all as specified and as directed
Providing , fixing and removing of water tight shuttering (Form work) using film coated 12 mm thick ply wood sheets and micro - concreteing self floating to columns in line and level with proper support of avg thickness 75-100 mm complete all as specified and as directed
Drilling 12 mm dia meter holes and about 75 to 100 mm deep in to the exposed / built up concrete which requires improvement at around 450mm c/c in stagered form from all surface, including removing of loose concrete / plasterd surface 25 mm average thickness complete all as specified and as directed
Providing and applying injection grouting the nozzle with high molecular weight low viscosity (200 CPS) Epoxy Resin like BASF make Mastreinject 1315/Conmix Re Con JVE of Conimix/Conbextra EP 10 of Fosroc/MONOPOL of Krishna Conchem ) and cutting the nozzole and filling the cavity with epoxy putty complete all as specified and as directed.
Providing, Epoxy bonding material to bonding of old concrete to new concrte by using and applying 25 mm avg thickness water compatible high strength thritropic ready use mortar (REP-PATCH 45 Tof infinite Options or equivalent) finished even and smooth complete all as specified and as directed.
Cutting the existing cracks in 'V' shape wherever the crack depth is less then 25 mm applying epoxy bonding material to bond old concrete to new concrete finishing the crack by polymer modified mortar complete all as specified and as directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
Anodised aluminium snap grid for false ceiling, with aluminium wall angle 25mm x 25mmx1.5mm, main T runner 38mmx25mmx1.4mm to be interlocked in such a way that the size of grid 605mm x 605mm and suspended with plain mild steel wire galvanised class 3 suspenders (2.5m long adjustable) including nuts and bolts, flat iron of size 25x3mm cut and bolts including provision of dash fasteners from ceiling all as specified and directed.
4mm thick decorative designer type pre-painted Non asbestos fibre cement building boards fixed or laid in slope and flat to Aluminium framework with screws of minimum size (600mm x 600mm) as in ceiling (Note: Existing E/M fittings and wiring in ceiling if any will be taken down carefully and refixing in same position, after completion of ceiling work without any extra cost to govt. complete all as specified and directed.
PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed
150 mm bore UPVC pipes including fittings, in any length with jointing till recharge pit complete all as specified and as directed
PVC half round joint brackets to join together length of plain pipe using the new pivot mounted clips to joint bracket through half round section of 300 mm dia fitted with deep rubber seals and screwed directed to facia and anchored by a suitable rafter bracket complete all as specified and as directed
Stainless steel CP Jet for EWC with hinges etc complete all as specified & as directed
Two way bib taps with health faucet with 1.2m brass flexible tube and wall hook mounted type cromium plated for EWC Make Prayag/Cera or equivalent complete all as specified and as directed
Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc.complete all as specified and as directed
Post construction Anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed.
Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified.
M&L for ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified.
Preparation of the surfaces of existing sunken floor thoroughly to have a sound base and application of two component acrylic polymer modified cementitious flexible waterproof coating with Brushbond Master Seal 550 (BASF) / Brushbond (Fosroc) / Pidifin 2K (Dr.Fixit) or equivalent in other approved makes at 1mm thickness. The coatings shall be applied at intervals and as per the manufacturer’s specifications. Providing Base Coat 20mm thick plastering in the CM 1:3 mixed with approved water proofing compound like Master pel 777(BASF) / Conplast WL (Fosroc) / Pidiproof LW (Dr.Fixit) or equivalent in other approved makes (Integral waterproofing compound confirming to IS 2645) for floor and walls. Proving Top Coat 20mm thick plastering in the CM 1:3 mixed with approved water proofing compound like Master pel 777(BASF) / Conplast WL (Fosroc) / Pidiproof LW (Dr.Fixit) or equivalent in other approved makes (Integral waterproofing compound confirming to IS 2645) for floor and walls. Providing and application Brushbond Coating of two component acrylic polymer modified cementitious flexible waterproof coating with Brushbond Master Seal 550 (BASF) / Brushbond (Fosroc) / Pidifin 2K (Dr.Fixit) or equivalent in other approved makes at 1mm thickness. The coatings shall be applied at intervals and as per the manufacturer’s specifications. NOTE :- The chemicals shall be applied only by specialist agency/approved applicator of the manufacturer. The specialist agency/approved applicator shall give necessary guarantee for ten years for the effectiveness of the treatment carried out.
ADDITION/ ALTERATION (B/R)
Precast cement concrete masonry type C4 as per IS-2185 Part-I 2005 with solid blocks having minimum average compressive strength of 4 N/Sqmm and minimum strength of individual unit is 3.2N/Sqmm, 10cm in width and setting in CM 1:4 all as specified
Precast cement concrete masonry type C4 as per IS-2185 Part-I 2005 with solid blocks having minimum average compressive strength of 4 N/Sqmm and minimum strength of individual unit is 3.2N/Sqmm exc 10cm in width and setting in CM 1:4 all as specified
Plain mild steel wire 4mm dia, galvanised class 3, in clothing line including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified and directed.
Mild steel nuts and bolts 20 mm dia exc 30 cm long provided with hole in each bolt for tightning of wire. Made with hexagonal or square head each screwed end to be fitted with washers complete all as specified and directed.
Rolled MS in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 290 Gde E-165 complete all as specified and directed.
Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc. complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and avg width of aperture 1.4mm dia fixed with tinned tacks of stainless steel wire stpales complete all as specified and as directed.
Powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified including powder coating (Minimum thicknesss of powder coating 50 micron) complete all as specified and directed.
Powder coated aluminium window and ventilator shutter, side hung type without sash, aluminium sections weighing 0.55kg/m incl necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no) hinges type B-21 100mm long(2 no) suitable handle (1 No) complete all as specified.(wire mesh / glass shutter) complete all as specified and directed.
Powder coated aluminium DECO grill 10mm thick DG 104 not less than 3.97Kg/Sqm fixed with necessary H/F/H channel etc complete all as specified and directed.(DECO grill fixed with windows with all fittings as directed by Engr-in-charge) complete all as specified and directed.
INTERNAL ELECTRIFICATION
Taking , down carefully copper / aluminium existing point wiring ( Light ,Fan , socket or power) complete (fittings such as switches , celling roses, pendants , regulators, sockets) etc complete all as specified and directed.
Taking down carefully U/S Main switch and DB's incl wooden board, and removing from site incl making good disturbed surfaces of wall all as complete as specified and as directed.
Dismantling and taking down fluorescent tube light single/ double Lamp, Mirror light, security light fittings of any wattage or size for repair or replacement of burnt/worn out/US accessories etc.complete all as specified and directed.
Point wiring complete as specification with 1100 V grade with 1.5 Sq mm single core PVC FRLS insulated unsheathed cable , copper conductor multistranded passing through including PVC concealed conduit of suitable size with all connected accessories & cutting chasing in any type of masonary wall and concealed GI/PVC/MS/cast iron box and logic modular white plates/ plate cover of suitable size as required at site with pvc insulated unsheathed stranded copper of size 1.5 sq. mm earth wire connected to common earth dully as specified for one light point /bell point /fan point controlled by one switch. with & including cutting/leaving forming chases for concealed conduits sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required complete all as specified and directed..
All as per item No 174 here-in-before but for 5 amps (2/3 pin) modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified and directed.
All as per item No 174 here-in-before but for 5 amps (2/3 pin) modular switch socket in Independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified and directed.
All as per item No 174 here-in-before but size of cable 4 Sq.mm for 16 amps and 6 amps (3 pin) combined and for industrial metal socket, modular switch socket in Independent board with earth wire 4 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified and directed.
Supply & fixing in repair Modular switch 1 way 6 Amps,1 module complete all as specified and directed.
S&F in repair Modular switch 1 way 16 Amps,1 module complete all as specified and directed.
S&F in repair Modular Socket 6A -2/3 pin combinaed 2 Module complete all as specified and directed.
S&F in repair Modular Socket 16A -2/3 pin combinaed 2 Module all as specified and directed by Engr-in-Charge
S&F in repair TV socket outlet modular type 1 module Make-Legrand or equivalentcomplete all as specified and directed.
S&F in repair RJ 11 Telephone socket modular type 1 module Make-Legrand or equivalent complete all as specified and directed.
S&F in repairs Metal flush boxes concealed for mounting TV /Telephone socket etc including logic modular plates and surrounds of suitable size Make- Legrand or equivalent complete all as specified and directed.
S&F in repair Rigid non -metallic PVC conduit of 20 mm dia concealed in wall exclusive of boxes (junction /terminal) but inclusive all tees bends elbows reducers and fixing accessories such as couplers lock nut saddles pipe hooks etc complete size of 20mm complete all as specified and directed.
Casing caping min 25 mm wide , double lock type in repairs by using existing wiring , for wifi/router cable, good finishing for including screws, bolts nuts, drilling etc complete all as specified and directed.
S&F in repair Ceiling rose surface bakelite White/ Ivory/ Urea Finish 50 mm dia three terminals including all electrical connections and supply and fix PVC square mounting block complete all as specified and directed.
Taking down existing light fitting fixed in wall/ceilling of any capacity or make with and S&F new 20W LED 4' Glaze LED Batten with decorative end caps and making necessary electrical connections and testing on completion all as directed Make Jaquar Cat No : LGLZ01X020XC 20 W CCT: CW or equivalent in other approved makes complete all as specified and directed.
Taking down existing light fitting fixed in wall/ceilling of any capacity or make with and S&F new 10W LED 2' Glaze LED Batten with decorative end caps and making necessary electrical connections and testing on completion all as directed Make Jaquar Cat No : LGLZ01X010XC 10 W CCT: CW or equivalent in other approved makes complete all as specified and directed.
S&F in repair new LED Recess mounted LED light fittings 36 Watts white powder coated CRCA housing with full window acrylic diffuser (2ftx2ft) and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Model ULTIMA ULTRA , Cat No LULTU1S036XC CCT; CW or equivalent in other approved makes complete all as specified and directed.
S&F LED Street light of 45 W in aluminium pressure die cast housing with toughen glass cover (IP 66 protection) on wall/Pole or in pipe, including connection from ceiling rose/ junction box to light fitting by using three core 1.5 sq mm cable multistranded copper conductor pvc insulated and pvc sheathed 1100V grade complete all as specified and directed. Make: Jaquar Model No-LED Street light Cat No- LSRT01S045XC CCT: CW or equivalent in other approved makes complete all as specified and directed.
S&F in repair 32 mm dia, 1.2 mtr length of medium grade pipe having suitable for item No 191 here-in-before and hold by saddle include all accessories to fix on the building complete all as specified and directed..
Taking down and refixing the Ceiling fan after repair work (i.e celaning, oiling, greasing, blade leveling, painting etc) complete with down rod and 3 core 1.5 sq mm copper conductor cable from ceiling rose to fan complete with all accessories complete all as specified and directed..
S&F in repair Step type electronic fan regulator modular type 120W ,2 Module complete all as specified and directed.
Supply and fix new exhaust fan, steel body copper wiring motor AC single Phase. 230V of size 450 mm sweep heavy duty with, blades, and frame and louvers/Shutter . Make- Bajaj or equivalent in other approved makes, including making hole of requisite size in round shape in existing wall and grouting the foundation bolts of required size and making good the disturbed surfaced with PCC 1:2:4 and Mortar 1:6 as reuuired duly painted with new paint matching with existing shape all as directed by Engr-in-charge.Including old exhaust fan deposite to MES store complete all as specified and directed.
Supply and fix exhaust fan, 300mm sweep, PVC body, AC, single phase, 230 V, copper winding motor, with blades, frame & louver shutter and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard with & including cutting, opening or required size hole (Square/ Round) through RR masonry/ brick walls for fixing exhaust fan and making good disturbed surfaces fo wall with CM 1:4 and painting with two coats of existing colour to match the wall complete all as directed by Engineer-in-Charge. NOTE : Old exhaust fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
Taking down and refixing the single phase electric geyser of any size/make after repair work (i.e. checking all electrical connection and replacement of connection cable of geyser, body painting) complete etc complete all as specified and directed.
S&F in repair Single pole enclosure with a two pin and earth plug and socket complete 240V with one single pole MCB 20 amp complete all as specified and directed.
Taking down Split/Window AC including refrigent gas recharge/suction in outdoor unit dismantling inner unit and piping with wiring carefully and keep in safe place and refixing same in similar place and position complete with and including testing after installation for smooth working complete all as specified and directed. Note:- Refrigerant gas recharge/suction and all required bricks/civil/ structure including outdoor unit stand deemed to inclusive in the same in above quoted rate.
S&F MCCB DB's VTPN (Vertical DB) 8 way, 415 V with rated bus bar, Suitable for Flush Mounting and Surface Mounting/ Concealed in wall, Make - Legrand Cat Part No 5077 52 Modules No- DPX3 160+24 with provision for DPX3 160 MCCB of 4P, 36KA Make - Legrant Cat Part No 4200 97 as Incomer, outgoing IP 54 Protection or equivalent in other approved makes, Complete all as specified and directed. Note: Rate of MCCB of 160 Amps and DB's VTPN are inclusive in above said item.
S&F Sheet metal encloser with socket plug top MCB TPN 63 Amp, 415 V , 50 HZ, 10KA, encloser with a three pin earth plug with socket complete with one triple pole MCB complete all as specified and directed.
S&F sheet metal enclosures for DB's double door in wall / nitch when MCB's to be used Triple pole and neutral, 4 way,415 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 12 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 8 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 4 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F in repair MCB SPN 40 AMP 240/415 V , 50 HZ, 10KA, complete all as specified and directed.
S&F in repair MCB SPN 32 AMP 240/415 V , 50 HZ, 10KA, complete all as specified and directed.
S&F in repair MCB TPN 63 Amp, 415 V , 50 HZ, 10KA, complete all as specified and directed.
S&F in repair MCB SP 240 V , 50 HZ, 10KA, suitable for lightning and other domestic load Rating 6-32 A complete all as specified and directed.
Taking down existing submain wiring and M&L concealed type sub main wiring along with earth wire with the folloing size of 2x6.0 Sq mm and 1x6.00 sq mm earth continuity conducor and connected to earth dolly ,PVC FRLS insulated single core multi stranded copper conductor cable drawn into and incl PVC concealed conduit of suitable size with all accessories and fittings like bends.crosses etc.complete all as specified and directed. Note: 3 runs of 6 sqmm cable and one run of PVC concealed conduit shall be measured as one unit length.
Taking down existin submain wiring and M&L concealed type sub main wiring along with earth wire with the folloing size of 2x4.0 Sq mm and 1x4.00 sq mm earth continuity conducor and connected to earth dolly ,PVC FRLS insulated single core multi stranded copper conductor cable drawn into and incl PVC concealed conduit of suitable size with all accessories and fittings like bends.crosses etc.complete all as specified and directed. NOTE : 1. 3 runs of 4 sqmm cable and one run of PVC concealed conduit shall be measured as one unit length. 2. Cost of cutting chases for concealed conduits and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in the quoted rate of this item.
Taking up existing Cable and Supply for Laying including fixing on wall/trenches/duct, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty electric LT UG cables with aluminium conductor, 1100 volts grade, cross sectional area 35 sq. mm 3.5 core compete all as directed.
Supply and Lay HDPE (High density polyethlene pipe) of pressure reting 6 Kg /cm 2 for protection of cable laid in trenches of Size 50 mm dia complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing and making good, cutting exc 10cm but not exc 20cm girth in stone walls, complete all as specified and as directed
Earthing complete with galvanised steel earth plate electrode 60x60cmx6.0 mm thick, buried directly in ground ( earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metras below normal ground level, connected to galvanised iron wire of 4 mm up to 7.5 mtr by means of bolt ,nuts ,check nuts and washers of galvanised iron or steel all as shown in electrcal plate No. 3 connected or indicated including testing on completion . incl necessry excation ,earth work ,pcc pit ,RCC cover, funnel with watering pipe 20mm bore medium grade ,GI protection pipe15 mm bore light grade complete all as specified and directed.
Taking down and refixing the existing electric meter single/three phase of any capacity or make, secure & make new all electrical connection complete all as directed by engineer-in-charge or as per site requirement complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep in soft /loose soil getting out and leveling of bottom surface to required level complete all as specified and directed.
Returning filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in trenches complete all as specified and directed.
Removal excavated material of soil from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5 mtr from the starting point complete all as specified and directed.
IDEAL CONSTRUCTION COMPANY
S t modi
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .