AMRUT-Augmentation of UWSS to Nedumangad Muncipality-Upgradation of Existing 13.75 MLD Water Treatment Plant at Perumala and Providing 3000 FHTCsPackage 7-Supply and Erection of Transformer and other related works-Pipeline Work-Pipeline Work
2026_KWA_866351_1
08/2026-27/KWA/PHC/D3/TVM
Open Tender
Civil Works - Water Works
Item Rate
300 days
Nedumangad
Please refer NIT
7 documents required · 7 mandatory
₹5,515
₹50,000
Yes
21 Aug 2026
21 Aug 2026
2 Sept 2026
21 Aug 2026
1 Sept 2026
21 Aug 2026
21 Aug 2026 - 1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Construction of Electrical Substation and other allied works | |||||
| 1.001 | OD300787/2025-2026:H T CABLING - Supply of 3C 240 sq.mm (A2XFY/A2XWY) XLPE insulated, PVC sheathed, Armoured cable with conductors of best conductivity Aluminium conforming to IS: 7098/II/85, 11KV grade approved by the Engineer in charge | - | metre | - | - |
| 1.002 | OD300803/2025-2026:H T CABLING - Laying charges for 3C 240 sq.mm one number XLPE insulated, PVC sheathed,
Armoured cable with conductors of best conductivity Aluminium conforming to IS: 7098/II/85, 11KV grade of following sizes direct in ground including excavation of trench of depth 1200 mm, providing protective covering with country burnt bricks laid breadth wise, sand cushioning, refilling the trench etc. as required and approved by the Engineer in charge /Consultant. | - | metre | - | - |
| 1.003 | OD300785/2025-2026:H T CABLING - Laying charges for 3C 240 sq.mm one number XLPE insulated, PVC sheathed, XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. | - | metre | - | - |
| 1.004 | OD300796/2025-2026:HT Cable End termination - Supplying and making HT cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 185 sq. mm | - | no | - | - |
| 1.005 | OD300818/2025-2026:CT/PT UNIT (INDOOR) - Supply, Testing,Installation and Commissioning of cast resin CT/PT unit (CT required rating , class 0.2S, 15VA; PT 11000 /110V, class 0.2, VA 100). Indoor cabinet , including 200A LBS , 12kv 3pole , 50ka is dust and vermin proof, IP-42, floor mounted, front operated, made out of 14/16 SWG thick CRCA sheet fully compartmentalized as per approved design and requirements, hinged doors , HT insulator bus bar, connection , lighting arrester provision for energy meter, and sealing option for all doors The rate includes testing of CT/PT unit at TMR Division of KSEB, obtaining test certificate and remitting of necessary fees. | - | no | - | - |
| 1.006 | OD300804/2025-2026:TOD METER - Supply, Testing and Commissioning of HT TOD Meter including Test terminal block, 3p 4W, front
connector, screw type. The rate includes testing of TOD Meter at TMR Division of KSEB, obtaining test
certificate and remitting of necessary fees | - | no | - | - |
| 1.007 | OD300808/2025-2026:11 KV Switch gear(Indoor) - Supply, erection, testing and commissioning of 11KV, 630A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and draw out type vacuum circuit breaker single panel system (1 no. VCB ) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system, comprising of motorized and spring assisted, independent, trip free closing mechanism and all metering equipment, protective relays,heating coils etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armored multi core 2.5 Sq.mm copper control cables shall be used for all external internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT panel. | - | no | - | - |
| 1.008 | OD300809/2025-2026:OUTDOOR TRANSFORMERS - Supply erection testing commissioning of 11KV/433V, 3 phase, 50 Hz, Vector group Dyn-11, Copper wound,Energy Efficiency Level-1, ONAN cooled, Outdoor, 1000KVA Transformer (Continuous rating) with on load tappings with AVR unit from +5% to -10% in steps of 2.5%, first fill of Oil upto MOL in the conservator. Transformer should have cable end box on HT side, LT side bus trunk with all other standard fittings and accessories, complete as required as per KSEI specifications and confirming to IS 1180. | - | no | - | - |
| 1.009 | OD300777/2025-2026:NEUTRAL CT WITH ENCLOSURE - Supply Installation, Testing and Commissioning of Neutral CT for the Transformers having CT ratio of 100/5, 15VA, class 5P10. It should be placed in a protected Metal box with facility for Testing. | - | no | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.06 MB
08NIT.pdf
Tender Documents • 0.24 MB
BOQ_1466308.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].