Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹25.8 L+₹30,804 (1.21%)Rejected-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹26.3 L+₹80,348 (3.15%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST | |
| 4 | L4₹26.5 L+₹1.0 L (3.92%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST | |
| 5 | L5₹27.0 L+₹1.5 L (5.75%)Rejected-AOC AIR FORCE ROAD GORAIMARI PO HALESWAR PS TEZPUR DISTT SONITPUR ASSAM 784104 | SONITPUR | ASSAM | 784104 | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
30 Oct 2021, 6:00 pmClosed
GE(AF) TEZPUR
GE(AF) TEZPUR POST-SALONIBARI DIST- SONITPUR ASSAM-784104
REPAIR AND MAINT OF CRANE , LIFT, VOLTAGE STABILIZER, FIRE HYDRANT AND OTHER CONNECTED MISC WORKS AT AFS TEZPUR
2021_MES_466116_4
GE(AF)/TEZ/43/2021-22
Open Tender
Civil Works
Item Rate
180 days
AFS TEZPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) TEZPUR
₹50,000
Yes
2 Feb 2022
25 Oct 2021
1 Nov 2021
25 Oct 2021
30 Oct 2021
25 Oct 2021
Amount
M & L for perodic inspection/ servicing of 02Ton capacity flame proof EOT crane of any make installed at different building/location at site, making the cranes in serviceable condition complete all as specified and directed with and including opeartions for maintenance specified as under:- (A) LONG TRAVERSE MOTION/CROSS TRAVERSE MOTION/HOIST MOTION- (a) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (b) Checking functioning of all brakes of any capacity and making adjustment for proper working. (c) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (d) Checking of grease in geared coupling and tighting of nut/bolts etc. (e) Checking of motion cut off at extreme ends with limit switches. (f) Checking drive shaft and coupling including tighting of nut and bolts. (g) Checking oil in FLP thrustors checking any leakage any filling with new oil. (h) Checking terminal connection of all LT motion of three phase FLP electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (B) ELECTRICALS (a) Checking and tightening all electric connection (b) Checking the contactors/ relays etc for overheating or flashinng. (c)Clening off all connection and control cables. (d) Properly bunching the loose control cable. (e) Checking functioning of cable carriers. (f) Checking the connection and serviceability of VVVF drives for smooth working. ( C ) GROUND MOTION CONTROL PANEL Opening the push button control unit, checking all connection, replacing flashed/over heated connections, general cleaning and checking all the functions of the LT/CT/Hoist motion push buttons and lights/VVVF switch including reassembling the unit complete LOAD TESTING:- Load testing complete for LT/CT/Hoist motion of the 2 ton EOT cranes ( installed at eleven different location with in TA complex) for 125% capacity using any type of dead weight complete and as directed. Note: 1. Necessary weights shall be arranged by the MES department. 2. Shifting of load at site and shifting to different buidings/ locations with in the complex using truck/mobile crane etc of suitable capacity shall be arranged by the contractor. 3. tools, tackles ,chains and sling etc of suitable capacity required for load testing shall be arranged by the contractor. 4. Unit rate quoted shall be made. adjustment of brakes, motors, gear boxes, electrical system, load hook, steel wire ropes, limit switches and all related item complete all specified and directed.
All as per Srl No 1.00 here-in-before but for of 5 Ton capacity EOT Cranes.
All as per Srl No 1.00 here-in-before but for of 10 Ton capacity EOT Cranes
All as per Srl No 1.00 here-in-before but for of 10 Ton capacity flame proof EOT Cranes.
All as per Srl No 1.00 here-in-before but for of 2 Ton manually operated overhead traveller capacity Cranes.
Supply fixing and making all connection ,limit switch capacity 40 Amp 415 Volts all as per existing for LT/CT/ Hoist motion of 10 ton capacity EOT crane including taking down old unserviceable complete all as specified and as directed.
Supply fixing and making all connection ,limit switch capacity 40 Amp 415 Volts all as per existing for LT/CT/ Hoist motion of 10 ton capacity FLP EOT crane including taking down old unserviceable complete all as specified and as directed.
S&F flame proof thrustor unit complete as per existing capacity 18 Kg incl taking down the old unserviceable all as specified and as directed.
Supply only gear oil grade 680 suitable for reduction gear boxes Note :-For item no 1 to 5
S&F brake liner set suitable for 100 mm dia drum for LT/CT motion of 10 Ton capacity FLP crane complete all as directed and specified
All as per item No 10 here-in-before but 160 mm dia drum complete all as specified and as directed
Supply and fixing brake liner set suitable for 150 mm dia drum for hoist motion of 10 Ton capacity FLP crane complete incl taking down old unserviceable complete all as directed and specified
All as per item no 12 here in before but 200 mm dia drum complete all as specified and as directed
Supply and fixing torque spring suitable for 6 Kg capacity 100 mm dia drum brakes of LT/CT motion incl taking out the old unserviceable complete all as specified and as directed.
All as per item no 14 here-in-before but 9 Kg capacity and 160 mm dia drum for LT/CT/hoist motion complete all as specified and as directed.
All as per item no 14 here-in-before but 20 Kg capacity and 200 mm dia drum for hoist motion complete all as specified and as directed.
S&F air break contactor 12 amps coil voltage 110 volts 50 Hz complete incl taking out the old unserviceable complete all as specified and as directed. Make ABB/L&T/Seimens
All as per item No17 here-in-before but 32 amps complete all as specifed and directed
All as per item No 17 here-in-before but 12 Amp Aux contactor complete all as specified and directed
All as per item No 17 here-in-before but 25 Amp Aux contactor complete all as specified and directed
All as per item No 17 here-in-before but 32 Amp Aux contactor complete all as specified and directed
M&L for MS coupling 25 mm dia with nuts ,bolts and bushes suitable for LT/CT motors incl taking out the old unserviceable all as directed.
All as per item No 22 here-in-before but 50mm dia for drive shafts complete all as specified and as directed
M&L for Rewinding of Hoisting Motor 10 HP by supper enamelled Copper winding wire of same gauge as existing one including heating, Varnishing and testing after completion all as directed by Engr-in-Charge.
All as per item No 24 here-in-before but 5 HP complete all asspecified and as directed
M & L for Serviceing and repairing of Oil Cooled Servo Voltage Stabilizer , by disconnecting of all incomming and out going cable , opening of top cover carefully, cleaning of motor , service connection ,gear pininon, lifting of core from the tank by opening cover, cleaning of tank, removing the sediment, cleaning of coils / electrical connections, filtration of transformer oil,fixing the core back in the tank, making electrical connection by replacing the consumable spares such as gaskets, rubber oil seals complete etc but other spares as listed here-in-after shall be replaced and cost of spare parts as supply only shall be measured and paid separately under relevent item after that testing of servo voltage stabilizer in presence of Engr-in-charge , complete as directed by Engr-in-Charge capacity servo voltage stabilizer 75 KVA thre phase
All as per serial item no 26 here-in-before capacity 200/250 KVA 3 Phase
All as per serial item no 26 here-in-before capacity 500 KVA /630 KVA 3 Phase Note for serial item no 26 to 29:- (i) Spare parts required to make serviceable of above oil cooled servo voltage stabilizer shall be measured and paid separately under relevent item here-in-after. (ii) Rewinding of barrier assembly and transformer assembly will be measured and paid separately.
Supply only Potentiometer.Make Volina/Hindustan/AE
Supply only Voltmeter (Digita). Make MECO, Havells,L&T,HPL/Crompton/AE
Ampere Meter with C. T. (Digital) Make MECO, Havells,L&T,HPL/Crompton/AE
Supply only P C B Holder.Make Volina/Hindustan/Servocon
Supply only Servo Motor 10 Kg Torque.Make Volina/Hindustan/Servocon
Supply only Servo Motor 20 Kg Torque.Make Volina/Hindustan/Servocon
Supply only Carbon Brush (20amps to 200 amps) Make Volina/Hindustan/Servocon
Supply only Carbon Holder & Spring.Make Volina/Hindustan/Servocon
Supply only Servo motor gear pinion.Make Volina/Hindustan/Servocon
Supply only R C Net work for 10 Kg Motor.Make Volina/Hindustan/Servocon
Supply only R C Net work for 20 Kg Motor.Make Volina/Hindustan/Servocon
Supply only Drive assembly 75 Kva per phase.Make Volina/Hindustan/Servocon
Supply only Drive assembly 200/250 KVA per phase.Make Volina/Hindustan/Servocon
Supply only Digital Control Panel with Circuit board for high / low Voltage cut per phase suitable for 3 phase Voltage Stabilizer of capacity upto 75/200/250/500 630KVA.
Supply only front control with wiring kit .Make Volina/Hindustan/Servocon
Comprehensive maintenance of fire fighting pumping installation installed at seven no different location , including minor repair of all parts involved for smooth operation/function of plant including greasing, cleaning, adjustment, minor repairs of nuts, bolts, washers etc of centrifugal fire fighting & jockey pump sets, DG sets of different capacity etc with other related equipments of the pump house/ installations alongwith valves including cleaning of inside and outside areas of the respective fire fighting pump houses, replacement of gland packing,coupling maintenance of suction and delivery pipe lines, primary fill up of priming tanks at different locations complete all as specified and directed by Engr-in-Charge
M&L for repair and maint of star delta Starter of any capacity of any capacity after disconnecting of incoming/outgoing connection, checking the serviceability of all components i.e existing contactors, Over load relay, timer, single phase preventer, indicator lights, replacement of brunt out PVC insulated copper wire, copper timble, re-connect the same after throughly cleaning and testing all as required and directed at site. Note:- Spare part shall be measured and paid separtaely under respective items of this schedule)
replacement of contactor of capacity 12 Amp, 3 pole,415 Volt, AC rating 3, type MNX 12 including auxiliary contact block NO & NC ( Make L&T /C&S)
replacement of contactor of capacity 25 Amp, 3 pole,415 Volt, AC rating 3, type MNX 12 including auxiliary contact block NO & NC ( Make L&T /C&S)
replacement of contactor of capacity 32 Amp, 3 pole,415 Volt, AC rating 3, type MNX 12 including auxiliary contact block NO & NC ( Make L&T /C&S)
Repacement of thermal overload relay of range 24-40 A. Make:- L&T,/ C&S/ Havells
Repacement of Star Delta timer adjustible type from 3 to 30 sec
Repacement of single phase preventer , SPPR type SDz5, 380 V ( For MU-G30 /40/50/75)
Comprenesive maintenance and rapair including renewal/replacement of defective parts of all existing fire detection system complete consisting of addressable fire control panel, Remote Terminal Unit panels, smoke/heat detector, response indicator, sounder, Manual call Point, Amlifier, Loud speaker, Loop isolator, Zone monitor module, Modem etc. to make 100 % serviceability of the complete incl checking of fire detector, cleaning of detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of batteries, the alarm function of control and indicating eqpt be checked by the operation of trigger device in each zone as described, the system installed in Fire station every month during first or last week as directed by engineer-in-charge Note:- (i) Cost of new components shall be paid for separately under relevant items of schedule 'A" sec-1 Item No. 42 to 48. (ii) Contractor's rep will visit minimum once in a month to every panel and take serviceability certificate duly signed by the user. Note : "Repair and maintenance of Fire Alarm system should be done through OEM or through the authorized service provider of the OEM or any other agency dealing with the installation and maintenance of FIRE ALARM REMOTE COMMUNICATION SYSTEMS (RTU) and has vast experience in the relevant field as approved by the next higher authority to the Accepting Officer".
Dismantling ,servicing of all multisensor detector with heat and smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and directed every three month
Supply only of 6 V, 4.5 AH battery supply for back up to RTU panel each panel as 2 No. Make: Exide/Amar Raja
Supply only of 12 V, 7 AH battery for back up to all FACP panel. Make: Exide/Amar Raja
Supply, installation and testing of acid lead battery of capacity 12 volts, 150 AH with one set of heavy duty battery terminals for connection all complete all as per specified and directed. (old unsv Battery to be deposited to be MES store Yard).
Supply, installation and testing of acid lead battery of capacity 12 volts, 100 AH with one set of heavy duty battery terminals for connection all complete all as per specified and directed. (old unsv Battery to be deposited to be MES store Yard).
Supply only Indoor type detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric /optical with base with self built intelligence all as specified and as directed.
Supply only electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a)Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A , c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key, d) Ingress Protection IP-43 & Material-ABS Make: GST
Supply and fix in repair RCCB 63 Amps 4 pole, 415 volt, 50 Hz, 30/100 mA including taking down of existing unsv RCCB as directed by Engr-In-Charge.
Supply and fix in repair RCCB 40 Amps 4 pole, 415 volt, 50 Hz, 30/100 mA including taking down of existing unsv RCCB as directed by Engr-In-Charge.
Supply and fix in repair RCCB 63 Amps 4 pole, 415 volt, 50 Hz, 300 mA including taking down of existing unsv RCCB as directed by Engr-In-Charge.
Supply and fix, installation testing and commissioning Encoder/Main drive suitable for existing ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms, with power operated doors, installed in G+2 Building including taking down of old unsv encoder unit complete all as specified and as directed by Engr-In-Charge.
Supply and fix, installation testing and commissioning main controller, main drive, main card, ARD unit, display Card, Emergency light unit, Field harness shaft flow switch unit, floor fin, Transformer 220 V AC suitable for existing ‘THYSSENKRUPP’ Make Passenger Lift of car capacity 8 (Eight) Passengers, with power operated doors, installed in G+2 ATC Building
Supply and fix in replacement ARD Unit battery + ARD Card suitable for existing ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms, with power operated doors, installed in G+2 Building including taking down complete with testing and commissioning complete all as specified and as directed .
Supply and fix in replacement Safety circuit suitable for existing ‘OTIS’ Make Goods cum Passenger Lift of car capacity 2500 Kilograms, with power operated doors, installed in G+2 Building with complete accessories/unit including taking down complete with testing and commissioning complete all as specified and as directed.
kabitaconstruction
THE BUILDERS
M/S A K MITRA
M/S R.B. Construction
M/S Kangkans
KAILSON
M/S LAKSHMI COOLING CENTRE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .