Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99,500Accepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.8 L+₹79,380 (79.8%)Accepted-AOC | L2 | Accepted-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹2,500
Closing Date
15 Jul 2020, 1:00 pmClosed
EXECUTIVE ENGINEER
P.H. DIVISION, KWA, THIRUVALLA
State Plan 2019-20 - Mini WSS to Nedumpala in Kottangal Panchayath - Supply and erection of booster pumpset
2020_KWA_363845_1
E-Tender No.1/2020-21/EE/PH/TVLA
Open Tender
Civil Works - Water Works
Item Rate
90 days
State Plan 2019-20 - Mini WSS to Nedumpala in Kott
Please refer Tender documents.
5 documents required · 5 mandatory
₹560
online
₹2,500
14 Aug 2020
10 Jun 2020
17 Jul 2020
10 Jun 2020
15 Jul 2020
10 Jun 2020
Amount
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore
Cutting and Grinding of dia. 50 mm G.I./ M.S. Pipe required for fabricating Non standard bend including cost of gas,all labour and hire charges of tools etc complete.as per direction.
Welding of dia 50 mm G.I./M.S Pipe, and special sheet required for fabricating Non standard bend by gas or electric plant for three run welding including cost of welding rod / gas, all labour and hire charges of tools etc complete.
Fabricating MS flanges of diameter 50 mm using 12 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates.
Providing flanged joints to double flanged G.I./C.I./ D.I pipes and specials, including testing of joints:up to 80 mm diameter pipe
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Supplying, Installation, testing and commissioning of pre-wired fluresent fittings / compact fluresent fittings of all types of TUBES , complete with all accessories etc.. Directly on sealing/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc... as required.
Providing and fixing plain 16/0.20mm (0.50 sq.mm) twin circular flexible FRLS PVC insulated, PVC sheathed copper cable direct to the wall with PVC clip / sealing etc.. . as required for connection
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amp modular socket outlet and 5/6 amp. Modular switchconnection etc… are required<br><br>
Wiring for circuit/Submain wiring alongwith earthwire with the 2x1.5 sq.mm +1 x1.5 sq.mm earth wire FRLS PVC insulated coper conducted single core cable in surface/ recessed medium class PVC coduit as required.<br><br>
Wiring for light point/ Fan point/Exhaust fan point/ call bell point 1.5 sq.mm FRLS PVC insulated coper conducted single core cable in surface/ recessed medium class PVC conduct with Modular switch, Modular plate, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated coper conductor single core cable etc... as required.
Supplying and fixing 5 Amp to 32 Amp rating, 240/415 volts 'C' curve miniture circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc..
Supplying, installing, testing and commissioning of 32 Amp. TPN (Main switch with box) tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising main complete with TPN disconnector FSU and HRC fuses, connections, earting as required.
Power allocation charges
Supply and erection of suitable HP submersible pumpset with all required accessories having the following specifications.Pump: Discharge-1.1lps, Head-65M, Motor speed 960-3000 rpm, Pf should be above 0.90,: The motor shall be squirrel cage induction motor of adequate capacity to drive the pump set at the specified duty condition. The motor shall be suitable for operating on 415 volts, Three/Single phase 50 hz AC supply and shall confirm to IS 315 and other relevant standards, including necessary panel board , capacitor , Earthing , erection & trial run of pumpset including maintenance for a period of 2 years.The contractor should prepare the paperwork for obtaining electric connections and charges to be paid to KSEB etc.. complete
MY OWN DISTRIBUTION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_513780.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .