Loading…
Loading…
Tender Value
₹55.7 L
EMD Value
₹55,724
Closing Date
31 Jul 2026, 5:00 pmClosed
Chief Officer NA,GIDC, Ankleshwar
ARC for Misc. Electrical Maintenance works for water supply and Drainage System at NA, GIDC, Ankleshwar
326719
01 of 2026-2027. Tender Sr. No. 06.
Open
Electrical and Maintenance Works
Works
Bharuch
17 documents required · 17 mandatory
₹2,832
Chief Officer, Notified Area, Ankleshwar
₹55,724
22 Jul 2026
22 Jul 2026
22 Jul 2026
31 Jul 2026
22 Jul 2026
No. 1 % LWC
Carry out routine maintenance and servicing
and testing up to 6300 Amp L.T. ACB with below
defined scope: (1) Cleaning of dust,spider web
,foreign particles. Etc . (2) Removal of old grease
with new grease for various parts.(3) Cleaning
of various parts with CRC.(4) Check the
1 tightness of all hardware (5)Checking of Spring 5 Job 1836.18
Charging, Closing & Tripping mechanism (11)
Measurement of IRV (12) Measuring of
closing/tripping time by time testing kit (13)
Measuring contact resistance by CRM kit.(14)
Release testing by OEM recommended testing
Carryout routine maintenance and servicing of
L.T. cubical panel board having approximately
15 to 22 Nos. of switches cleaning and servicing
the contacts with CRC, tighting the connections
of incoming and outgoing cables. and hacking
the operating mechanism for smooth
2 functioning of switches. and putting them in 5 Job 2140.19
smooth working order. (Consider of following
feeder on LT Cubical Panel - 800 Amp ACB -
Nos, 90-132 KW VFD-04 Nos, 150 KVA APFC
panel, all bus bar, switches, Power & Controle
wiring, all termination, Cooling fan of VFD &
Panel, 150 A SFU -03 Nos)
Servicing, overhauling, cleaning of the panel
board LT by liquid EPNF-065™ technology
after scanning the single side of panel by
thermal scanning technology. Thermal scanning
technology includes measuring temperature
before and after servicing by each & every space
of the panel board.
One side of panel must be cleaned by Air Sq.
Compressor Capacity 2.5 to 3.5 HP Motor, 1 or Mtr
3 phase, 230v, Air tank having capacity approx
50 kg with latest moisture filter, spray gun
having EPNF-065™ liquid. The work having time
constraints of 2 to 5 minutes single side of the
panel. After finishing work agency has to
provide 3 photographs or to provide 2 minutes
video. Dust or any waste material must be
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
collected by agency in the bottom of panel board
by non woven fabrics material or any scientific
materiel. Agency has to carry out work in
presence of site in charge engineer & to
complete the work as per site in charge
Labour charges for Round the clock Routine
Preventive Maintenance of below Panels. It
includes the Attending the fault and Complete
Control Panels Servicing / Repairing /Cleaning
of all panels with checking of all the terminals of
Star Delta Connectors/Over load Relay/Single
Phase Preventer /Timers/ Auto Transformer.
Checking of all the Lugs & Nut-bolts condition
and if found unhealthy then cleaning of all the
Rust and Deposited Carbon on faulty Terminal.
It means the job include the Complete Repair &
Maintenance of all the panels per month or as an
when required with all contact kits Cleaning,
Tightening of Connections, Power & Control
wiring repairing / Replacement of panel
accessories (if required)
Servicing & overhauling of HT-DP strecture with
GOD switch, DO fuse, lightining arrestors etc.
comp. With double coat Al. painting as
instructed by the engineer in charge. Job also
including replace all non working spare parts
like Male Contact, Female Contact, Tinned
Copper Jumper, M.S. Jumper Carrier, Back
Connector, Misc. Hardware like Nut-bolts,
Operating Road, Pin and Disc, Insulator Etc.
Complete as per directed by Engineer In-charge
Routine Maintenance of 300 to 1000KVA
Transformers. It includes the Checking/
Servicing/ Maintenance of H.V. /L.V. Cable End
Termination and if required then replacement
of H.V. / L.V. Side Lugs with Proper Method with
6 Required Tools like Crimping Machine. The Job 6 Job 10089.53
also includes the checking of Oil Level of
Transformer/ Silica Gel Brether Condition/
Day-farm Condition and attending the outside
oil leakage faults if found with replacement of
Outer Side Gasket if necessary.
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
SITC Of various spare part of ABB Make & ACS
550 - Model VFD AS and where Required as
Below for Following Capacity VFD - 157 Amp,
180 Amp and 195 Amp
a CONTROL BOARD SMIO-01C 1 Nos 25400.00
b DRIVE DISPLAY ACS-CP-C 1 Nos 5000.00
MAIN INTERFACE CARD SINT4610C (after
week 50/06 manuf)
CURRENT CARD SCIB-01C (after week 50/06
e SRFC4611C INPUT FILTER KIT 1 Nos 32500.00
f RFI) filter printed circuit board RRFC6641 3 Nos 6000.00
g MAIN FAN 6314 HR 1 Nos 20500.00
h DC Capacitor ALS30C1023NP 4 Nos 12500.00
Snubber Capacitor on IGBT MKP
C4BSNBX4120ZAJJ
j Chowk OCHO5630 IP21 1 Nos 15000.00
IGBT SKM300GB128D (FF200R12KE3)
IGBT FF300R12KE3 (SKM400GB128D)
IGBT FF300R12KE3 (SKM400GB128D)
n CHARGING RESISTOR CAH-150-C-27R 1 Nos 7000.00
o DISCHARGING RESISTOR NXBU-3X6,8 65W 1 Nos 8000.00
p THYRISTOR TD162N16KOF SPKIT 3 Nos 12610.00
q SKELTON PLASTIC HOSING DRIVE BODY 1 Nos 10000.00
SITC of Miniature circuit breaker single pole 6A
to 25A suitable to operate on 240 V A.C. system
8 and having breaking capacity 10 KA to be 2 Ea. 112.11
erected in existing box. confirming to IS
8828/1996 with ISI Mark.
Supplying & erecting directly operated single
9 phase preventer complete erected and 2 Ea. 1078.68
connected to supply up to 45 Amp. range
SITC of Digital volt meter/ Ammeter with
Supplying and erecting approved make set of
indicator lamps of LED type lamp, lens cover,
Bakelite holder complete erected with
necessary connections.
12 SITC of Push button with elements 2 Ea. 205.40
13 SITC of Electronic Timer 2 Ea. 1540.52
SITC of Electronic Overload Relay with auto
scrolling & all protection for motors)
15 SITC of 63A Contactor MNX400 L&T make 2 Ea. 7909.47
Measurement of earthing resistance by loop test
after isolating & cleaning joint.
All Inclusive comprehensive maintenance cost
for the period of one year for the EOT Crane,
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
Crane panel, Motor, Starter / Starter Panel,
remote, wiring & Cables of up to 5 Tone
Providing, and erecting 22 KV D.P. 6 mtr. high
Structure made of G.I. 6" x 3" ‘I’-Section Girder,
4" x 2"channels, clamps, nuts, bolts etc. Suitable
for erection of the followings duly connected
with necessary ACSR conductors. as per
drawing approved by the Engineer- in charge
complete with following. Height as per IS 7 Mtr
above ground ) (A)
22 KV 200 Amps Drop out fuses with S.R.B.P.
18 tubes carries.-Three nos (B) 22 KV G.O.D. 1 set 98433.59
switch complete with insulators, operating
handle with galvanised pipe, Sq.bar etc.
Amp.- One Set (C) 22 KV lightening
arrestor with clamp- Three Nos.
(D) 22 KV shackle insulators- Six Nos. (E)
The above D.P. structure should be earthed with
25 mm.X 3 mm thick double copper earth strips
run separately and connected with separate
copper plate earth electrode.
Making trench in soft soil of suitable width of
cm deep for laying cable or locating the fault all
over the run and back filling the same and
making the surface as normal ground.
Making trench in Hard Murrum / Tar Road of
suitable width of 90 cms or required depth for
20 laying any size of cable or locating the fault all 200 Mtr 74.74
over the run and back filling the same and
making the surface as normal ground.
(B) If additional machineries like hammer
driller or JCB use [Add]
Microprocessor Based LV Variable
Frequency Drive
Suppl, installation, testing & commissioning of
415 V Fully automatic microprocessor based
Variable Frequency drive for pump control
application as per general specification as
under: The VFD unit shall have modular
construction, 6 Pulse Bridge rectifier, speed
control by means of sensorless vector control
(open loop), high torque at low frequencies,
locking at high and low frequency settings, In-
built PID control, frequency accuracy of ± 0.1 %
(min), frequency resolution of ± 0.1 Hz (min),
protections against; a) overload (motor and
drive), b) short circuit, c) ground fault, d) input
/ output phase loss (open circuit), e) stalling, f)
input / output undervoltage (momentary power
loss restart), g) input / output overvoltage, h)
over-frequency, i) Input surge, j) over
temperature of heatsink, k) loss of remote speed
signal etc. The VFD shall also have userfriendly
programming software & it shall be capable of
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
at least two level parameter setting with
password lock for critical parameters,
programming for I/Os, speed search function,
copy parameters (upload / download) to other
identical unit, tuning to energy saving mode
(maximum efficiency), event / fault recording
(last 5 faults in non-volatile memory) & RS
communication port (MODBUS RTU protocol)
with required software. ( ABB Make (ACS
Model) suitable for 90 KW Motor (Pump
Application)
Supply, laying, testing & commissioning 1.1 kV
grade, XLPE insulated, stranded Aluminium
conductor, galvanised steel flat strip / round
wire armoured, extruded PVC type ST2
sheathed, heavy duty cable (to be laid on wall
23 surface with necessary clamps / in existing
cable trench / cable trays / conduit / pipe
sleeves at road crossing or floor as per site
requirement) conforming to IS:7098 (Part-1) &
IEC:60502 (Part-1) of following sizes:
a 4 Core x 10 Sqmm 500 Mtr 97.00
b 4 Core x 16 Sqmm 500 Mtr 108.00
c 3.5 Core x 25 Sqmm 200 Mtr 134.00
d 3.5 Core x 50 Sqmm 200 Mtr 211.00
e 3.5 Core x 70 Sqmm 200 Mtr 287.00
f 3.5 Core x 95 Sqmm 200 Mtr 343.00
g 3.5 Core x 120 Sqmm 200 Mtr 423.00
h 3.5 Core x 150 Sq.mm 100 Mtr 504.00
i 3.5 Core x 185 Sq.mm 100 Mtr 622.00
j 3.5 Core x 240 Sq.mm 100 Mtr 783.00
k 3.5 Core x 300 Sq.mm 100 Mtr 954.00
Supply, laying, testing & commissioning 1.1 kV
grade, XLPE insulated, stranded Copper
conductor, galvanised steel flat strip / round
wire armoured, extruded PVC type ST2
sheathed, heavy duty cable (to be laid on wall
surface with necessary clamps / in existing
cable trench / cable trays / conduit / pipe
sleeves at road crossing or floor as per site
requirement) conforming to IS: 7098 (Part-1) &
IEC: 60502 (Part-1) of following sizes:
a 4 Core x 2.5 Sq.mm 500 Mtr 81.00
b 4 Core x 4 Sq.mm 200 Mtr 141.00
c 4 Core x 10 Sq.mm 150 Mtr 295.00
d 3.5 Core x 25 Sq.mm 100 Mtr 640.00
e 3.5 Core x 50 Sq.mm 100 Mtr 1155.00
f 3.5 Core x 70 Sq.mm 100 Mtr 1634.00
g 3.5 Core x 95 Sq.mm 100 Mtr 2346.00
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
h 3.5 Core x 120 Sq.mm 150 Mtr 3001.00
i 3.5 Core x 240 Sq.mm 100 Mtr 5805.00
Supply, installation, testing & commissioning
heavy duty APP type capacitor unit, vacuum
impregnated with non-PCB / non toxic oil,
25 internally delta connected with built in internal 100 KVAR 285
fuses complete with discharge resistances &
terminal cover, rated for 440 V AC, 3 Phase,
Hz as per IS: 13585 Part-1. APP type Capacitor
Providing & fitting heavy duty brass cable
glands (nickel-plated) with washers & rubber
26 ring conforming to IS, suitable for 3, 3½ & 4 core
cables of following type & sizes: Single
Compression Brass Cable Glands
Solder less crimping type Aluminum lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
Solder less crimping type Copper lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
Providing pair of rubber hand gloves suitable
for working on 11 KV/22 KV supply.
Supplying rubber matting of following thickness
30 15 Sq.Mtr 3081.51
as per IS:15652/IEC 61111 - 12 mm
Providing and erecting cable end termination
kit, heat shrinkable Push on type Densons’/
‘Raychem’/ Elastimold make suitable for 22 KV
XLPE cable 3 core 95 & 120 Sq.mm
a Outdoor type 1 Ea 14611.67
b Indoor type 1 Ea 8004.25
Outside painting of Transformer for the
following capacity (A) 250 / 315 / 500 KVA,
32 cleaning of old paint, remove all corrosion with 10 Ea 1583.68
proper maner then after applyig pain as per
standered paint
Graphitized Expanded PTFE Graphite Braided
Compression Packing for Pump Gland or Valve
Stem or Mechanical Seal. Graphite / Asbestos
Gland Packing (3 mm to 45 mm ) Teflon Glamd
34 Supply of Standard Make oil & Grease
a 15W40 100 Ltr 375
b Valvoline (HLP 46) 100 Ltr 218
c Servo 90 GEAR HP 90 Gear Oil 100 Ltr 848
d Gulf Crown MultiPro Automotive and Non-
Automotive High-Performance, Multi-Purpose 100 Kg 330
Providing and erecting approved make four
pole moulded case circuit breaker having
braking capacity ICU of 25 KA to 50 KA at 415 V
35 with thermal & Magnetic release suitable to
work on A.C. supply 50 c/s. with all internal
connections & complete erected in existing
G.M.S. housing
a 125 Amp (35 KA) 1 Ea 8055.76
b 200 Amp (35 KA) 1 Ea 16221.61
c 250 Amp (35 KA) 1 Ea 20946.39
d 400 Amp (50 KA) 1 Ea 25228.79
Approved make Four Pole LT Heavy Duty
Switch Disconnector Fuse Unit Cubical type for
panel mounting complete with operating
36 mechanism suitable to operate on 415V A.C.
With HRC fuses of suitable load confirming to IS.
13947 (Part I & III). of following capacities. Cat-
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
a 125 Amp 1 Ea 6120.60
b 200 Amp 1 Ea 8072.93
c 250 Amp 1 Ea 9348.56
d 400 Amp 1 Ea 11684.69
Supplying Knife / Blade / DIN type HRC fuse link
37 capable to withstand 80 K.A. confirms to I.S.
13703 for following current capacity
a 63 Amp. to 100 Amp.(Size 000 ) 3 Ea 214.12
b 63 Amp to 100 Amp (Size 00) 3 Ea 309.06
c 125 Amp to 160 Amp (Size 00) 3 Ea 368.65
d 100 Amp to 200 Amp (Size 0) 3 Ea 445.41
e 125 Amp to 200 Amp (Size I ) 3 Ea 565.60
f 250 Amp (Size I ) 3 Ea 634.28
g 200 Amp to 400 Amp (Size II ) 3 Ea 831.23
h 400 Amp to 630 Amp (Size III ) 3 Ea 1275.63
Supplying & erecting earth pit of minimum bore
dia.150mm size , approved make Safe Earthing
Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free
G.I.Pipes having Outer pipe dia of 50mm having
38 80-200 Micron galvanising, Inner pipe dia of
mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant
ohmic value surrounded by highly conductive
compound with high charge dissipation suitable
for following type of applications.
(a)For Electrical installation up to 11 KV in
a normal soil. Length of Pipe : 2.00 mtrs Back 1 No 5760.03
filling Compound :1 no. Bag of 25 Kg.
(b) For Electrical Installation covering
Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer
b System(like Automation, SCADA) i.e 1 No 8636.51
independent Earthing in normal soil. Length of
Pipe : 3.00 mtrs Back filling Compound :2 nos
Bags of 25 Kg.
Providing and erecting AC-3 duty 3 pole power
contactor with 2 NO & 2 NC aux contacts
39 complete with 415V/220V operating coil
suitable for (L&T, BCH,T.C., Siemens, C&S
a for 25 / 32 A rating 3 No 1152.00
b for 40 A rating 3 No 2292.00
c for 60 / 70 A rating 2 No 3972.00
d for 80 / 95 A Rating 2 No 5400.00
e for 110 A rating 2 No 6612.00
Supplying skilled man power of at Notified Area
Ankleshwar as and when required. (i.e. 2 pairs
dresses, 1 pair safety shoes, badges, caps and
belts to his staff essential and suitable for
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
performing job). Necessary Insurance charges
statutory provision, EPF, Medical, Bonus, W.C.
Policy, Personal Protective Equipment (PPE),
pay leave (PL), Public Holiday(PH), weekly Off,
shall be borne by the agency. The agency has to
work as per instruction of Engineer- in- charge
/ Officer in charge of Notified Area Authority as
per specification given in Technical Bid. Agnecy
have strickly provide all statutory provision like
EPF, ESIC, Salary on Bank transfer, Bonus, Pay
Leave ETC per month with all required
document and then after bill process by the
department if not submitted as per rules
payment will be made accordingly
a Electrican / plumber/ Fitter 150 No 672.54
b Skill Labour 150 No 657.44
Providing and erecting required size HOT deep
Galvanised iron strip for earthing of H.T. , OCB/
ACB/ Transformer LT panel board, Motors etc.
using proper clamp.
Providing and erecting required size Copper
strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc. using
copper clamp.
Supply, installation, testing & commissioning of
flange ends Expansion Bellow as per EJMA
standards of overall length of minimum
mm, designed for 15 mm axial compression and
5 mm axial extension with tie rods etc. of
following MOC & pressure ratings. MOC:
Bellows: SA 240 Gr. 304; Internal Sleeve: SA
Gr. 304; Weldends: IS 2062 Gr. B; Flanges: IS
2062 Gr. B (Drilling as per IS 1538 / IS 6392 ) &
Limit Rods & Nuts: CS - IS 1367. PN -
Lowering / Lifting of 3 phase submersible pump
set with MS / GI column pipe or HDPE Pipe into
bore well inculding checking of therads of each
pipe with coupling / welding & jointing cable
44 with fuse unit box / control panel board 16 No 2800.00
including fitting accessories by means of
mechanised derrick / chain pulley block
including satisfactory testing. Above 150 meter
to 300 meter depth
Ultrasonic Type Level Transmitter with Remote
Display :
Design, Supply, Installation, Testing and
Commissioning of NOn Contact Ultrasonic Type
Level Transmitter with Remote
The sensor should be non contact type, field
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
mounting type, housing shall have minimum
IP65 protection, PP/ PVC Sensor MOC, with
sensor to transmitter cable.
Remote Indicator cum Transmitter:
Microprocessor based indicator with LED / LCD
digital display,panel/ wall mounting type,
power supply shall be 110-240 Vac or 15 to
Vdc, 50 Hz ± 10 %.
Accesories: Mounting bracket, nut, bolts etc as
per system requirement and Hook up diagram
of the Instruments.
Level Transmitter shall be suitable for following
Range. 4-20mA Splitter -02 Nos
Supply Voltage - 24VDC
Control Input - 4-20mA
Control Output - 2Nos 4-20mA
SMPS -01 Nos
Supply Voltage - 240VAC
Output Voltage - 24VDC
Current Capacity- 2A
IOT Gateway SMIT 1937i - 01 Nos
GPRS/GSM gateway Interface
Control Input - 4-20mA( Dual Channel)
Supply Voltage- 24VDC
Push data on Cloud , Din rail mounted
1 Year Subsciption included need to renew
every year
SIM CARD IN PARTY SCOPE
Display (25.20"x 12.60") - 01 Nos
Neumeric Dot Metrix Type 3 Digit Display
Supply Voltage - 240VAC
Control Input -4-20mA
Providing and fixing approved make Perforated
C type cable tray. Made from sheet steel. The
cable tray should be single or double bended as
per required and as per IS 2062/1079 and shall
be coated with hot dip galvanizing as per IS
46 2629/4759. with max 17.5% perforation with
coupler plate / Fish plate and GI hardware like
nut - bolt and washers etc. erection with
necessary support( included) as per
Specification and as per instruction of engineer
in charge..
(1) 50 X 50 X 1.6 mm Thick 50 Rmt 305.02
(2) 100 X 50 X 1.6 mm Thick 50 Rmt 360.57
(3) 150 X 50 X 1.6 mm Thick 50 Rmt 424.20
(4) 200 X 50 X 1.6 mm Thick 50 Rmt 496.92
(5) 300 X 50 X 2.0 mm Thick 150 Rmt 622.16
(6) 450 X 50 X 2.0 mm Thick 12 Rmt 801.94
Total Rs.
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
Sr.No Above Below
1 I / We hereby agree carry out the I / We hereby agree carry out the
work at the rate given in Schedule B work at the rate given in Schedule B
@ _______ % above. @ ______ % below.
2 Net Amount Rs. _______ Net Amount Rs. _______
Important Note:
1. The rates offered shall be inclusive of all applicable taxes (1% LWC, ESIC, PF,
packing, forwarding, insurance, loading, unloading, shifting & transportation at
store/ site of work at Ankleshwar Notified Area.)
The rates offered by Bidder shall be Exclusive of GST.
2. I/We have read the conditions mentioned in this tender & agree to abide by the
3. Please note that the agency in whose favor the tender is finalized by the competent
authority shall have to submit the document like insurance of the staff engaged
RPFC No. Labor license etc. and documents for vehicle.
4. This is a O&M work, the agency has to operate & maintain the system as per
instructions of engineer-in-charge during the contract period. During contract
period the wages & facilities to be provided to the staff engaged by the agency as
per labour laws & accordingly rate may please be quoted.
5. The successful bidder in whose favor the tender is finalize by the competent
authority has to enter in to an agreement with Notified Area office in B-1 agreement
form, the conditions & clauses of the agreement shall be binding to the agency. If
the bidder desires to study the same, the same is available in the office of the
Notified Area Officer, GIDC, and Ankleshwar during office hours of the working
7. 1% labour welfare cess on the bill amount will be deducted from the each RA bill
as per Govt. norms.
8. Agency has to pay ESI / Professional Tax/PF etc as per Govt. norms. Agency has to
submit the photocopy of challan of ESI and PF paid at every month. If the same is
not submitted by the agency, ESI /Professional Tax/PF deducted from the RA Bill
by the NAO. Payable amount.
SIGNATURE OF CONTRACTOR CHIEF OFFICER
NA, GIDC, ANKLESHWAR
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
DTP for ARC for Misc Electrical Maint .pdf
BOQ sr no 6.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .