Assistant Executive Engineer
Assistant Executive Engineer LSGD Division Idukki Painavu
GENERAL-DP Works 2021-22- Kaippa DWSS in Kudayathoor Gramapanchayath ( Elamdesam BP)(413/22)-General Electrical Work-TENDER
2023_LSGD_618685_3
11/T/AEE/LIDEW/IDK/2023-2024
Open Tender
Electrical Works
Item Rate
240 days
KUDAYATHUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
₹5,553
Yes
5 Jan 2024
3 Nov 2023
15 Nov 2023
3 Nov 2023
14 Nov 2023
3 Nov 2023
3 Nov 2023 - 14 Nov 2023
Amount
Providing Pump Set -
OD207727/2023-2024:Supply, conveyance, erection, testing and commissioning of 12.5HP VERTICAL OPENWELL SUBMERSABLE PUMPset working on 3 phase 415 V, with head 276 meter and discharge range 12000 LPH Pipe size 50mm x 50mm ( DECCAN or equalant make etc as required.
OD207703/2023-2024:Supply and providing BCH make Star Delta Starter control with protection against overload, single phasing, phase reversal & severe unbalanced voltages conditions, in accordance with latest IS/IEC 60947-4-1 specifications suitable for 12.5 HP submersible motor pump set complete duly internally connected
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
90.14.24.5:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors.
OD207704/2023-2024:Supply and providing Cable Joint Tape etc. as required.
OD207705/2023-2024:Supply and Providing 50 mm or nearest size UPVC Adaptor Set DC CI with accessories etc
OD207706/2023-2024:Supply and fixing 50mmx 12" GI Barrel nipple
OD207707/2023-2024:Supply and fitting 50 mm or nearest size GI Bend on pumping main with flanges welded and nut bolt etc on pumping main.
OD207709/2023-2024:Supply and fitting 50 mm or nearest size Non Return valve using required bolt and nut and flange etc
OD207710/2023-2024:Supply and providing clamp set CI 50mm Heavy
OD207711/2023-2024:Supply and fixing 25mm Ball Valve with 15mm nipple and 15mm socket duly welded as required
OD207712/2023-2024:S&I of Pressure meter with accessories and stopper valve etc on delivery side of 50 mm GI pipe line as required
OD207713/2023-2024:Supply and fitting 50 mm GI socket etc. as required.
OD207714/2023-2024:Supply and Providing 50 mm GI pipe (Medium class) Cutting threading welding and with accessaries etc
OD207715/2023-2024:Supply and provide NYLON ROPE MAXIMA LG 12MM or nearest size for hanging submersible pump set
OD207716/2023-2024:Supply and providing Cotton waste etc. as required.
OD207717/2023-2024:Supply and providing Shellac 50 ml etc. as required.
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD207719/2023-2024:Supply and providing 25x3mm brass nut and bolt etc. as required.
OD207720/2023-2024:Supply and fixing 63 A 415 V , 2 way neutral link mounted on DMC / SMC base in the existing meter board and giving connection etc.
OD207721/2023-2024:Supply and fixing 63 A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
K T SHAJI
Bidder Name
K T SHAJI
JOSEPH V J
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_928781.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .