Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 14 5 TRIPUNITHURA KOTTAPARAMBIL BUILDINGS KOLLANPADY VILLAGE TOWN THIRUVANKULAM CITY TRIPUNITHURA ERNAKULAM KERALA 682309 INDIA | ERNAKULAM | KERALA | 682309 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance GREEN WORLD ELECTRIC PUTHUR PO GREEN WORLD ELECTRICAL ENGINEERING PANOOR VILLAGE TOWN PUTHUR CITY THALASSERY | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance H NO 8 1 398 PM 189 PARAMOUNT HILLS TOLICHOWKI HYDERABAD 500 008 | HYDERABAD | HYDERABAD | TELANGANA | 500008 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹12,100
Closing Date
7 Nov 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr. Sujith P.M
HOCL, AMBALAMUGAL
Renovation Of Occupation Health Centre (Electrical Works)
2024_HOCL_832219_1
HOC/ELE/WP/7051/24
Limited
Electrical Works
Works
365 days
HOCL, AMBALAMUGAL
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹12,100
Yes
8 Nov 2024
23 Oct 2024
8 Nov 2024
23 Oct 2024
7 Nov 2024
23 Oct 2024
Supply and installation of 20mm size of medium class PVC conduit along with bends, elbows, tee, PVC junction boxes and other accessories in conceiled manner including cutting the wall and making good the same as required
Supply and installation of 20mm size of medium class PVC conduit along with bends, elbows, tee, PVC junction boxes and other accessories as required. The wiring system should be surface wiring and holes should be provided in the required wall.
Supply and installation of 25mm size of medium class PVC conduit along with bends, elbows, tees, junction boxes and other accessories in conceiled manner including cutting the wall and making good the same.
Supply and installation of 25mm size of medium class PVC conduit along with bends, elbows, tees, junction boxes and other accessories as required. The wiring system should be surface wiring and holes should be provided in the required wall.
Supplying and drawing 1.5 sqmm size of FR/FRLS PVC insulated copper conductor, single core cable in the existing PVC conduit as required. 'Existing' refers to another item that has already been included in this list.
Supplying and drawing 2.5 sqmm size of FR/FRLS PVC insulated copper conductor, single core cable in the existing PVC conduit as required.'Existing' refers to another item that has already been included in this list.
Supplying and drawing 4 sqmm size of FR/FRLS PVC insulated copper conductor, single core cable in the existing PVC conduit as required. 'Existing' refers to another item that has already been included in this list.
Supplying and fixing 2 module, GI box alongwith modular non-metallic base and cover plate (1 or 2 module) for modular switchs in concealed manner including cutting the wall and making good the same.
Supplying and fixing 3 module, GI box alongwith modular non-metallic base and cover plate for modular switchs in concealed manner including cutting the wall and making good the same.
Supplying and fixing 4 module, GI box alongwith modular non-metallic base and cover plate for modular switchs in concealed including cutting the wall and making good the same.
Supplying and fixing 6 module, GI box alongwith modular non-metallic base and cover plate for modular switchs in concealed manner including cutting the wall and making good the same.
Supplying and fixing 8 module, GI box alongwith modular non-metallic base and cover plate for modular switchs in concealed including cutting the wall and making good the same.
Supplying and fixing 12 module, GI box alongwith modular non-metallic base and cover plate for modular switchs in concealed manner including cutting the wall and making good the same.
Supplying and fixing 1 way, 6A, 1 module modular switch on existing modular plate & switch box including connections but excluding modular plate, etc. as required.
Supplying and fixing 2 way, 6A,1 module modular switch on existing modular plate & switch box including connections but excluding modular plate, etc. as required.
Supplying and fixing 1 way, 6A, 2 module modular Bell push type switch on existing modular plate & switch box including connections but excluding modular plate, etc. as required.
Supplying and fixing 1 way, 16A, 1 module switch on existing modular plate & switch box including connections but excluding modular plate, etc. as required.
Supplying and fixing 3 pin, 6A modular socket outlet on existing modular plate & switch box including connections but excluding modular plate, etc. as required.
Supplying and fixing 6 pin, 16A modular socket outlet on existing modular plate & switch box including connections but excluding modular plate, switch box etc. as required.
Supplying and fixing one module stepped type electronic fan regulator on existing modular plate & switch box including connections but excluding modular plate, switch box, etc. as required.
Supplying and fixing Telephone socket outlet RJ11 modular socket outlet on existing modular plate & switch box including connections but excluding modular plate, switch box etc. as required.
Supplying and fixing LAN socket outlet RJ45 modular socket outlet on existing modular plate & switch box including connections but excluding modular plate, switch box etc. as required.
Supplying and fixing modular blanking plate (one module) on the existing plate & switch box excluding modular plate, switch box, etc. as required.
Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box including connections etc. as required.
Replacement of existing Distribution board with new 6 way, 26 module (8+3x6), TPN, sheet steel, MCD Distribution board (flush mounting, Double door enclosure), 415V, on concealed mannerincluding cutting the wall and making good the same , complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing, etc. as required. (But without MCB/RCCB/Isolator). Scope include dismantling of old DB including disconnection of circuits, MCBs, Isolation, Power cable, etc as required.
Supplying and making end termination with brass compression gland and alumimum reducer pin type lugs for 3.5Cx35sqmm size of PVC insulated armoured cable as required. The scope includes fixing of existing cable (of above size) in conceiled manner including cutting the wall and making good the same. (max 1.5 metre)
Supplying and fixing of 40A, four pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning, etc. as required
Supplying and fixing of 40A, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning, etc. as required
Supplying and fixing of 6A, 240/415V, 10kA, "C" Curve, MCB suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning, etc. as required
Supplying and fixing of 10A, 240/415V, 10kA, "C" Curve, MCB suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning, etc. as required
Supplying and fixing of 16A, 240/415V, 10kA, "C" Curve, MCB suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning, etc. as required
Supplying and fixing of 20A, 240/415V, 10kA, "C" Curve, MCB suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning, etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5sqmm FRLS PVC insulated, copper conductor, single core cable.
Installation of Exhaust fan in the existing opening
Supply and installation of recessed mounting 36/40 W LED fixture, 2FT X 2FT size, 6500K on false ceiling, connecting it using 3Cx1.5 sq. mm FR PVC insulated, copper conductor from the light fixture to the ceiling rose. Length of cable shall be 1 metre.
Supply and installation of Recessed Square Panel Light, 12W, 130mmx130mm approx size, 6500K on false ceiling, connecting it using 3Cx1.5 sq. mm FR PVC insulated, copper conductor from the light fixture to the ceiling rose. Length of cable shall be 1 metre.
Supply and installation of LED Batten tube light , 20W, 4FT along with Clips and Screws.
Supply and installation of Surface waterproof industrial luminaire suitable for single 4 FT, T8, LED Tube
Supply and installation of Retrofit LED Tube Rod, 6500K,
Dismantling old switch boards of size up to 10"x3" including disconnecting switches/sockets/regulators as required
Disconnecting old twin tube light fitting/ceiling fan from ceiling roof.
Dismanltling of old wiring circuits including removal of conduits, cables, casing caps, wires, PVC Junction boxes, saddles, etc as required.
ABY ELECTRICALS
GREEN WORLD ELECTRICAL ENGINEERING
Universal ELectricals
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .