Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC PLOT NO DSS 170 HUDA SHOPPING COMPLEX SECTOR 31 FARIDABAD FARIDABAD HARYANA FARIDABAD HARYANA 121003 | FARIDABAD | HARYANA | 121003 | ₹1.5 Cr | L1 | Accepted-AOC L1 hence accepted |
| 2 | L2₹1.7 Cr+₹14.9 L (9.66%)Rejected-AOC E 2 216 GROUND FLOOR SHIV RAM PARK NEAR LUCKY GARDEN NANGLOI NEW DELHI 110041 | WEST DELHI | DELHI | 110041 | ₹1.7 Cr+₹14.9 L (9.66%) | L2 | Rejected-AOC L2 hence rejected |
| 3 | L3₹1.7 Cr+₹17.1 L (11.1%)Rejected-AOC 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹1.7 Cr+₹17.1 L (11.1%) | L3 | Rejected-AOC L3 hence rejected |
| 4 | L4₹1.8 Cr+₹21.9 L (14.2%)Rejected-AOC | ₹1.8 Cr+₹21.9 L (14.2%) | L4 | Rejected-AOC L4 hence rejected |
| 5 | L5₹1.9 Cr+₹35.7 L (23.1%)Rejected-AOC 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹1.9 Cr+₹35.7 L (23.1%) | L5 | Rejected-AOC L5 hence rejected |
| Sl No | Description | Qty | Unit | Supertech Engineers L2 | S G TECHNOFAB PVT LTD L1 | Voltas Limited L5 | POWER TECHNOLOGIES L4 | STERLING AND WILSON PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Annual All Inclusive Comprehensive Maintenance of water cooled complete HVAC system having screw/centrifugal chiller,chilled and condenser water circulating system,cooling tower, AHUs, associated electrical and water softener systems, . The job includes day to day maintenance of the systems, attending to the complaints, repairs/rectification works including consumables / spares, breakdown/ preventive /routine maintenance as per OEM recommendations /maintenance schedules, maintaining records etc. as required as per list of Inventory in Technical Specification page no. TS 4 - TS 5.
International terminal HVAC Installations.
(i) First Year ( 2026-27) | 12 | Month | 1,42,500 ₹17,10,000 | 1,38,600 ₹16,63,200 | 1,44,015 ₹17,28,180 | 2,00,000 ₹24,00,000 | 1,12,429 ₹13,49,148 Lowest |
| 2.00 | Annual All Inclusive Comprehensive Maintenance of water cooled complete HVAC system having screw/centrifugal chiller,chilled and condenser water circulating system,cooling tower, AHUs, associated electrical and water softener systems, and all as detailed elsewhere in the tender document. The job includes day to day maintenance of the systems, attending to the complaints, repairs/rectification works including consumables / spares, breakdown/ preventive /routine maintenance as per OEM recommendations /maintenance schedules, maintaining records etc. as required as per Inventory list in Technical Specification page no. TS 4 - TS 5.
International terminal HVAC Installations.
(ii) Second Year ( 2027-28) | 12 | Month | 1,46,000 ₹17,52,000 | 1,44,900 ₹17,38,800 | 1,48,335 ₹17,80,020 | 2,10,000 ₹25,20,000 | 1,18,526 ₹14,22,312 Lowest |
| 3.00 | Annual All Inclusive Comprehensive Maintenance of water cooled complete HVAC system having screw/centrifugal chiller,chilled and condenser water circulating system,cooling tower, AHUs, associated electrical and water softener systems, and all as detailed elsewhere in the tender document. The job includes day to day maintenance of the systems, attending to the complaints, repairs/rectification works including consumables / spares, breakdown/ preventive /routine maintenance as per OEM recommendations /maintenance schedules, maintaining records etc. as requiredas per Inventory list in Technical Specification page no. TS 6.
Domestic terminal HVAC Installations.
(i) First Year ( 2026-27) | 12 | Month | 45,000 ₹5,40,000 | 31,500 ₹3,78,000 Lowest | 39,067 ₹4,68,804 | 60,000 ₹7,20,000 | 50,225 ₹6,02,700 |
| 4.00 | Annual All Inclusive Comprehensive Maintenance of water cooled complete HVAC system having screw/centrifugal chiller,chilled and condenser water circulating system,cooling tower, AHUs, associated electrical and water softener systems, and all as detailed elsewhere in the tender document. The job includes day to day maintenance of the systems, attending to the complaints, repairs/rectification works including consumables / spares, breakdown/ preventive /routine maintenance as per OEM recommendations /maintenance schedules, maintaining records etc. as required as per Inventory list in Technical Specification page no. TS 6.
Domestic terminal HVAC Installations.
(ii) Second Year (2027-28) | 12 | Month | 48,000 ₹5,76,000 | 33,600 ₹4,03,200 Lowest | 40,239 ₹4,82,868 | 65,000 ₹7,80,000 | 52,233 ₹6,26,796 |
| 5.00 | Operation of water cooled complete HVAC system of International and Domestic terminal buildings, with all related equipments and accessories including AMS operations on all days including Sundays, Holidays and National Holidays, as per the requirements of AAI as indicated in elsewhere in the tender document. | 24 | Month | 5,04,500 ₹1,21,08,000 | 4,60,000 ₹1,10,40,000 | 5,95,744 ₹1,42,97,856 | 4,50,000 ₹1,08,00,000 Lowest | 5,35,333 ₹1,28,47,992 |
| 6.00 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.80 mm sheet | 15 | Sqm | 1,220 ₹18,300 | 1,009 ₹15,135 Lowest | 1,350 ₹20,250 | 2,500 ₹37,500 | 2,400 ₹36,000 |
| 7.00 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.60 mm sheet | 40 | Sqm | 1,050 ₹42,000 | 871 ₹34,840 Lowest | 1,100 ₹44,000 | 2,500 ₹1,00,000 | 1,800 ₹72,000 |
| 8.00 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
19mm | 45 | Sqm | 1,050 ₹47,250 | 615 ₹27,675 | 710 ₹31,950 | 2,000 ₹90,000 | 612 ₹27,540 Lowest |
| 9.00 | Replacement of existing MS Drain pipes/Overflow pipes of cooling towers with 100mm CPVC pipes from cooling tower basin to the drain header lines for 08 nos branches each includes suitable termination to existing MS drain header line complete with all accessories like all fittings,threaded sockets,flanges etc for jointing complete as required . | 4 | Meter | 725 ₹2,900 | 519 ₹2,076 Lowest | 2,250 ₹9,000 | 2,500 ₹10,000 | 7,500 ₹30,000 |
| 10.00 | Replacement of existing MS Drain pipes/Overflow pipes of cooling towers with 80mm CPVC pipes from cooling tower basin to the drain header lines for 04nos branches each includes suitable termination to existing MS drain header line complete with all accessories like all fittings,threaded sockets,flanges etc for jointing complete as required . | 4 | Meter | 695 ₹2,780 | 391 ₹1,564 Lowest | 1,580 ₹6,320 | 5,000 ₹20,000 | 2,364 ₹9,456 |
Tender Value
₹2.0 Cr
EMD Value
₹6.0 L
Closing Date
5 Mar 2026, 11:00 amClosed
SM EE
SM(EE), AAI, Calicut International Airport, Calicut Airport PO, Malappuram, Kerala - 673647
ARMO of E and M Installation at Calicut International Airport 2025_26_ SH _ Operation and Annual Comprehensive Maintenance Contract for Centralized HVAC System at Calicut International Airport for 2026-28
2026_AAI_266572_1
AAI/CL/EE/299/NIT-09/2025-26
Open Tender
Electrical Works
Works
730 days
Calicut Airport
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,180
₹6.0 L
19 Jun 2026
11 Feb 2026
6 Mar 2026
12 Feb 2026
5 Mar 2026
12 Feb 2026
12 Feb 2026 - 18 Feb 2026
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
tenderdocument.pdf
Tender Documents • 6.67 MB
BOQ_310013.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .