| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC Accepted - Being L1 bid | |
| 2 | L2₹42.9 L+₹1.6 L (3.80%)Rejected-AOC | L2 | Rejected-AOC Rejected - Being higher than L1 bid | |
| 3 | L3₹48.4 L+₹7.1 L (17.1%)Rejected-AOC | L3 | Rejected-AOC Rejected - Being higher than L1 bid | |
| 4 | L4₹50.9 L+₹9.6 L (23.3%)Rejected-AOC | L4 | Rejected-AOC Rejected - Being higher than L1 bid |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
25 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SILCHAR
GE SILCHAR, MASIMPUR, ASSAM 788025
COMPREHENSIVE MAINT BR AND EM TO OTM ACCN OF MINOR UNITS AT MASIMPUR MIL STN UNDER GE SILCHAR
2021_MES_446559_1
8632/E8
Open Tender
Civil Works
Item Rate
180 days
MASIMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹80,000
Yes
3 Jul 2021
28 May 2021
26 Jun 2021
28 May 2021
25 Jun 2021
11 Jun 2021
60 days
Amount
PART-I (B/R WORKS) Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed
Dismantling timber scantlings 40 sqcm and over in section, in any position, unframed work, etc complete all as specified.
Dismantling of timber fillets rails, posts, rafters, purlins etc under 40 Sqcm in section, in any position in unframed work complete all as specified and directed.
Dismantling timber boarding of any description fixed in any position with nails complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, etc complete all as specified & directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) n.exc 1.5 sqm each complete all as specified & directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but n exc 4 sqm each complete all as specified & directed.
Taking down shutter of any description each not exceeding 1 Sqm each leaf complete all as specified and directed.
Taking down shutter of any description each exc. 1 Sqm but not exc.2 sqm each leaf complete all as specified and directed.
Taking down shutter of any description each not exceeding 1 Sqm each leaf & refixing in same opening complete all as specified and directed.
Taking down shutter of any description exceeding 1 Sqm & not exceeding 2 Sqm each leaf & refixing in same opening complete all as specified and directed.
Supply and fix second class hard wood plain, solid, straight chowkats and frames, wrought framed rebated on the solid rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
Supply and fix PVC door frame of size 50 mm X 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified & directed.
Supply and fix Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door frames with one or more rebates including hinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified and directed.
All as per item no.16 but of size 105x60 mm, complete all as specified and directed.
Supply and fix 30 mm thick second class hardwood glazed and skeleton shutters for ventilator/windows, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars,. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified.
Supply and fix Steel windows with side hung shutters including box type hinges with steel handles, 2 Nos steel tower bolts 100mm long peg stay complete with glazing bars, dovetailed or welded, including locking arrangements complete all as specified.
All as per item no. 19 above but without glazing bars, complete all as specified and directed.
Supply and fix Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements complete all as specified and directed.
M&L for 35 mm thick Second class Hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or 12mm thick veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified and directed.
M&L 2nd class hard wood, 35 mm thick, glazed and skeleton shutter, divided into square, with plain, chamfered or rounded mitered and , any number of panels, prepared to receive glass, gauge etc. edges of frames chamfered or round size of numbers of shutters as specifed in SSR Part-I section clause 8.24 (a) complete all as specified and directed.
Material and labour flush shutters, 30mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides including 6/8mm thick polished teak wood lipping alround the door properly fixed complete all as specified & directed.
Supply and fix Factory made wire gauzed PVC moulded door shutter 30 mm thick (style) panel will be of wire gauze in lieu of single side prelaminated sheet panel. The wire gauze shall be wrapped on an additional sqaure 8mm MS solid tube and this tube shall be welded to MS tubes the the wire gauze shall be stretched and tightened firmly consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and prelaminated colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified.
S&F 20mm dia mild steel, chromium plated curtain rods with brackets, including fixing stops, rollers bracket & side end cap fancy type complete all as specified and directed.
S&F 150 mm size mild steel door springs, complete all as specified and directed.
Supply and fixed door closer hydraulically , designation no.1, universal type of aluminium( extruded section body) suitable for door shutters, complete all as specified and directed.
Supply and fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm , complete all as specified and directed.
Supply and fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm and fixed in repairs, complete all as specified and directed.
Supply and fix 3.00 mm thick sheet galss ordinary quality and glazing with oil putty in square not exc. 0.50 sqm in each pane, complete all as specified and directed.
Supply and fix 3.00 mm thick sheet galss ordinary quality and glazing with oil putty hacking out old broken glass ( any thickness, size , quality or description) from wooden frame or stone, conrete or brick surrounds, glazed with putty or fixed with beads complete of size in square not exc. 0.50 sqm in each pane, complete all as specified and directed.
Supply and fix for GI wire netting 0.70 mm dia and 12 mm mesh lathing to wood or metal studding joints etc in walls ceiling stanchion, beams etc included all laps cutting and wasts complete all as specified & directed.
Supply and fix 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed.
Supply and fix 100 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed.
Supply and fix 150mm size extruded aluminium alloy handles cast type anodized complete all as specified & directed.
Supply and fix 100mm size extruded aluminium alloy handles cast type anodized complete all as specified & directed.
Supply and fix Butt hinges, medium weight, cold rolled mild steel, 100 mm size, complete all as specified & directed.
Supply and fix Butt hinges, medium weight, cold rolled mild steel, 75 mm size, cocomplete all as specified & directed.
S&F 2nd class hard wood timber scantling wrought fixed to framed work complete all as specified and directed.
S&F 2nd class hard wood timber scantling clean sawn fixed to framed work complete all as specified and directed.
Material and labour brick work with sub class ‘B’ brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6, complete all as specified and directed
Material and labour brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick wall built in cement mortar 1:4, complete all as specified and directed
Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water complete all as specified & directed.
M&L rendering 15 mm thick cement rendering in two layer each of 10+5 mm thick on fair faces of brick wall or concrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified & directed. Note -WPC shall be measured and paid separetly.
Material and labour rendering 10 mm thick in CM 1:6 on other than fair faces of brick work or concerete surfaces finished even and smooth without using extra cement complete all as specified & directed.
Material and labour rendering 10 mm thick in CM 1:6 on other side of lathing finished even and smooth without using extra cement complete all as specified & directed.
M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick one side of lathing in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified & directed.. Note -WPC shall be measured and paid separetly.
Supply only water proofing compound complete all as specifid and directed.
Material and labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in hold fast including necessary form work complete all as specified & directed.
Demolition cement concrete (un reinforced) of any description fin ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Material and labour for 75 mm thick PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregates as in floor finished fair and even complete all as specified & directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified & directed
Material and labour Non-skid colour ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors set and jointed in cement slurry and pointed in white or colour cement to match existing surfaces over & including 15 mm thick screed bed or bedding layer of cement mortar 1:6, for laying floor finishes over brushing with neat cement slurry with 3.00 Kg of cement per sqm complete all as specified & directed
Material and labour Non-skid colour ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors set and jointed in cement slurry and pointed in white or colour cement to match existing surfaces over & including 15 mm thick screed bed or bedding layer of cement mortar 1:6, for laying floor finishes over brushing with neat cement slurry with 3.00 Kg of cement per sqm complete all as specified & directed
Material and labour Non-skid colour ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in skirting set and jointed in cement slurry and pointed in white or colour cement to match existing surfaces over & including 14 mm thick screed bed or bedding layer of cement mortar 1:4, for laying floor finishes over brushing with neat cement slurry with 3.00 Kg of cement per sqm complete all as specified & directed
Material and labour Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm and not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed or bedding layer of cement mortar 1:6, for laying floor finishes over brushing with neat cement slurry with 3.00 Kg of cement per sqm incl roughening of surfaces complete all as specified & directed
Material and labour Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm and not exceeding 0.36 sqm, in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick screed bed or bedding layer of cement mortar 1:4, for laying floor finishes over brushing with neat cement slurry with 3.00 Kg of cement per sqm incl roughening of surfaces complete all as specified & directed
Material and labour of Glazed ceramic coloured tiles in vertical surfaces size 450 x 300 x 6 to 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10 mm thick screed bed or bedding layer of cement mortar 1:4, for laying floor finishes complete all as specified & directed
Material and labour for Granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite incl rounding edges including 15 mm thick screed bed or bedding layers in cement mortar 1:4 over brushing with neat cement slurry with 3.00 Kg of cement per sqm incl taking out of the existing complete all as specified & directed
M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement laid in panels and joints filled with bituminous 1 part and 3 part of sand complete all as specified and directed.
Material and labour for 25 mm thick pre polished chequered cement concrete tiles , area of each tiles exceeding 0.06 Sqm and not exceeding 0.11 sqm, set and jointed in neat cement slurry and pointed with white or coloured cement to match the tile over & including 20 mm thick screed bed or bedding layer of cement mortar 1:6, for laying floor finishes over brushing with neat cement slurry with 3.00 Kg of cement per sqm complete all as specified & directed
Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS:4923 - 1997 grade St.-210 complete all as specified & directed.
Supply and fix Framed work such as grills, gratings, etc. with ends of bars or forged into spikes, framed guard bars, barred iron doors; ladders; framed balusters, walk ways, railings, framework of water tanks and similar work con- forming to Fe 290 Gde E-165, complete all as specified and directed.
Supply and fix mild steel work hold fast, cleat etc for windows frame/ wooden batten etc quality confirming to Fe-290 Gde-E-165, complete all as specified and directed.
Dismantling of asbestos cement (Corrugated or semi corrugated etc) as in roof covering complete all as specified & directed
Material and labour for 6 mm thick asbestos cement corrugated or semi corrugated sheets as in roofs, walls etc fixed with ‘L’ type or ‘J’ type cranked hook complete all as specified & directed
Material and labour for Asbestos cement two piece adjustable ridge 6mm thick serrated ridge for corrugated or semi corrugated sheet fixed with ‘L’ type or ‘J’ type cranked hook complete all as specified & directed
Dismantling of plain or corrugated steel sheeting, any gauge or any thickness in roof covering /wall cladding complete all as specified & directed
Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed
Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed
Supply and fix 0.63 mm thick corrugated galvanised steel sheetings with two corrugation side lap fixed with ‘L’ type or ‘J’ type cranked hook bolts, nuts and washers as in roof, wall etc with grade of zinc coating 275 gm/sqm complete all as specified & directed
All as per item No.73 above but except sheets, complete all as specified and directed.
Supply and fix 0.63 mm thick plain galvanized mild steel sheeting in ridges , hips, valley, gutters, drip and straight flashings( length or girth as fixed) with grade of zinc coating 275 gm/sqm, complete all as specified and directed.
Supply and fix second class hard wood 50 mm thick boarding, clean sawn, fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified & directed
Supply and fix second class 20 mm thick boarding planned one side fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified & directed
Material and labour for 2nd class fillets square, rectangular or tringular in section clean sawn screwed with nails exceeding 6 sqcm and not exceeding 13 sqcm complete all as specified & directed
Material and labour for 2nd class fillets square, rectangular or tringular in section clean sawn screwed with nails exceeding 13 sqcm and not exceeding 25 sqcm complete all as specified & directed
Material and labour for 2nd class fillets square, rectangular or tringular in section wrought screwed with nails exceeding 6 sqcm and not exceeding 13 sqcm complete all as specified & directed
Material and labour for 2nd class fillets square, rectangular or tringular in section wrought screwed with nails exceeding 13 sqcm and not exceding 25 sqcm complete all as specified & directed
Material and labour for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall, Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600 mm grid and painted with two coats of acrylic emulsion paint of approved shed /make over a coat of cement primer before installing it on the grid all as specified and directed.
Material and labour for 4 mm thick Asbestos cement plain building boards, fixed to timber framework with screws as in ceiling complete all as specified & directed
Material and labour for second class hard wood plain fillets, square, rectangular and triangular in section, wrought, bull nosed, splayed, chamfered or rounded on one edge or face, sectional area exceeding 6 sqcm but not exceeding 13 sqcm complete all as specified & directed
Taking up or down 15mm dia GI steel tubing and connections complete all as specified & directed
Taking up or down 20mm dia GI steel tubing and connections complete all as specified & directed
Cutting grooves or rebates not exceeding 15 cm girth, and trimming with or without reinforced surfaces complete all as specified & directed
Supply and fix in GI tube 15 mm dia (ISI Marked) medium grade galvanished with all fittings laid in floors /wall etc. complete all as specified and directed.
Fixing only old steel tubing of 15mm bore and connections in new or old position (walls, ceiling, floors, etc) including cleaning or returning the old screw threads incl new GI fittings as required complete all as specified & directed Note : Serviceable steel tube obtained from taking down shall be reused.
Supply and fix in GI tube 20 mm dia (ISI Marked) medium grade galvanished with all fittings laid in floors /wall etc. complete all as specified and directed.
Fixing only old steel tubing of 20mm bore and connections in new or old position (walls, ceiling, floors, etc) including cleaning or returning the old screw threads incl new GI fittings as required complete all as specified Note : Serviceable steel tube obtained from taking down shall be reused.
Taking down rain water pipe & sewage line pipe of any type & any size including fittings complete all as specified & directed
Supply and fix 110mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or as in floor with suitable size complete all as specified & directed
Supply and fix as in repairs 75 mm dia PVC (SWR) pipes single socketed, in any length, fixed to walls with suitable size of MS clamp & nuts -bolts of suitable size complete all as specified & directed
Supply and fix in repair PVC (SWR) bends any radius, 110mm bore, fitted with oval access door complete all as specified & directed
Supply and fix in repair PVC (SWR) bends any radius, 110mm bore, fixed in repairs complete all as specified & directed
Supply and fix in repairs PVC (SWR) bends any radius, 75mm bore, fitted with oval access door complete all as specified & directed
Material and labour for 75mm dia oultlet PVC (SWR) floor trap, plain with chromium plated grating including jointing with solvent cement complete all as specified & directed
Supply and fix, as in repair, vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified.
Supply and fix, vitreous china squatting pan of Orrisa pattern size 580 mm x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including 'P' or 'S' trap and lime concrete bedding connection making good to floor fixed in repairs complete all as specified.
Vitreous China urinals, bowl type urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) all as specified.
Supply and fix in repairs PVC valveless, syphonic action type, low level PVC flushing cistren 10 ltr cap white with flush pipe & all fitting and flush pipe complete all as specified & directed
Supply and fix, as in repair, 15 mm bore bib taps fancy type, chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed
Supply and fix as in repair 15 mm bore pillar tap fancy type, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe complete all as specified & directed
Supply and fix, as in repair, angle stop valve fancy type, cast copper alloy, chromium plated, screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions complete all as specified & directed
Supply and fix Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 ltr capacity hoisted and fixed in position complete all as specified & directed
Supply and fix Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 ltr capacity hoisted and fixed in position complete all as specified & directed
Supply and fix 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixedcomplete all as spcified & directed
M&L for 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ ) complete all as specifed and directed
Supply and fix PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified & directed
Supply and fix PVC waste pipe 32mm dia of length 900mm PTMT fixed in repairs complete all as specified & directed
M&L for 15 mm bore Bib tap fancy type standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms). complete all as specified and directed.
M & L for preparation of new or previous untreated surfaces and applying three coats of white wash on surface walls complete all as specified and directed
Material and labour for preparation of newly plastered or un plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer over to make the surface finished even & smooth complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coat of oil bound distemper (white or tinted) over one coat of whiting on wall over one coat of 3 mm thick putty and primer complete all as specified and directed.
Material and labour for preparation of new or previously untreated surfaces and applying two coats of exterior emulsion ( anti fungal) over a coat of primer complete all as specified and directed
Material and labour for preparation of new or previously untreated wall surfaces and applying two coats of cement based paint over a coat of cement primer complete all as specified.
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified.
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description not exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified.
Material and labour for preparation of new or untreated steel surface of any description exceeding 10 cm in width or girth and applying two coats of synthetic enamel paints, over a coat of red oxide primer, complete all as specified.
PART-II (E/M WORKS)Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed.
Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated cable with stranded copper conductor of size 4 Sq. mm nominal area and drawing into PVC non metallic rigid PVC casing including one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor as earth wire complete all as specified and as directed. Note:- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of PVC casing caping will be measured as one unit.
Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated cable with stranded copper conductor of size 6 Sq. mm nominal area and drawing into PVC non metallic rigid PVC casing including one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit.
Supply and fix 1100 Volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 6 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanges not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable wire all as specified and directed.
Supply and fix 1100 Volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 10 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanges not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable wire all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc. all as directed.
Material and labour for Point wiring using approved colour coding as per IS with stranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with GI sunken boxes with earth dolly and 3mm laminated cover sheet suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light/fan/bell/exhaust fan point / bell point controlled by one switch.
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 109 above but with stranded copper conductor 2.5 Sq mm (nominal area), two single core, PVC insulated and unsheathed cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.
All as per item No. 109 above but with stranded copper conductor 4 Sq mm (nominal area), two single core, PVC insulated and unsheathed cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 4 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.
Supply and fix ceiling rose surface bakelite with three terminals all as specified and directed.
Supply and fix switch piano flush type button single pole one way 5 Amps complete all as specified and directed.
Supply and fix socket outlet 3/5 pin 5 Amps flush type completeall as specified and directed.
Supply and fix switch socket combination 2 in 1, 5/15 Amps flush type complete all as specified and directed.
Supply and fix ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified and directed.
Supply and fix lamp Angular holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix Bell Push flush type 5 Amps complete all as specified and directed.
Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
Supply and fix wall mounted LED batten for 1x22 watt LED tube rod both side connection box type complete all as specified. Make:- Havells, Product Code : REGALBATTERNT8UPTO1X22WDSBSWH or equivalent make of Philips/Bajaj/Wipro/Syska LED/Crompton Greaves/M/s Surya Roshni Limited /M/s Jaquar & Company Pvt Ltd
Supply and fix wall mounted LED tube rod 20 watt, pin on both side suitable for fixing upto 22 watt battens complete all as directed. Make: Cat No. CRYSTAL1213T8DSTL20WLED865SGLASS of Havells or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
Supply and fix street /bldg security light LED luminaire 15 watt IP 66 LED lamp, driver etc, including service bracket with all accessories as specified and directed. Make: Cat No. ENDURAPEARLSL15WLED757SASYTOPCMPof Havells or equivalent to Bajaj/Philips/Wipro/Syska LED/ M/S Surya Roshni Limited/M/S Jaquar & Company Pvt Ltd/Crompton Greaves
Supply and fix in repair plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. Make :- BAJAJ MAXIMA DX 5 BLADE (250 MM ) or equivalent.
Dismantling old unserviceable main switches, Sheet metal enclosures DB including MCBs etc and keeping in safe custody either for reuse or for disposal including making good to the disturbed surfaces of wall all as directed.
Supply and fix metal plug socket single pole and neutral enclosure with two pin earth plug with 1 No. MCB SP 20 Amp 'C' series complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated single phase DB for fixing of MCBs, 4 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated three phase and Neutral DB for fixing of MCBs, 4 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
Supply and fix MCB SP 240 volts, 50 Hz capacity 6-32 Amps all as specified and directed
Supply and fix MCB SPN 240 volts, 50 Hz of capacity 40 Amps all as specified and directed
Supply and fix MCB TPN 415 volts, 50 Hz of capacity 63 Amps all as specified and directed
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed.
Taking down MCCB's /change over of any size and capacity all as directed.
Supply and fix MCCB's 3 Pole, 415 volts Adjustable type, 160 Amp with breaking capacity of 16 kA all as specified.
Supply and fix MCCB's 3 Pole, 415 volts Adjustable type,250 Amp with breaking capacity of 36 kA all as specified.
Supply and fix MCCB's 3 Pole, 415 volts Adjustable type, 250 Amp with breaking capacity of 36 kA all as specified.
Taking down 600x600 mm/ 300x300mm/ round PL type light fitting down lighter complete with all accessories complete all as specified and directed.
Supply and fix 600x 600 mm LED type down lighter 36 Watt complete with drivers, connecting accessories and provision of fixing arrangement in false ceiling complete all as specified and directed. Make:- Crompton Cat No. LCPL-36-CDL(2X2) Aura 1 or equivalent in BAJAJ/PHILIPS/WIPRO/HAVELLS/SYSKA LED/ M/s SURYA ROSHNI LIMITED/M/S JAQUAR & COMPANY PVT LTD
Supply and fix 300x 300 mm LED type down lighter 9 Watt complete with drivers, connecting accessories and provision of fixing arrangement in false ceiling complete all as specified and directed. Make:- Crompton Cat No. LSDE0-09-CDL(1X1 FEET) Quartz or equivalent in BAJAJ/PHILIPS/WIPRO/HAVELLS/SYSKA LED/ M/s SURYA ROSHNI LIMITED/M/S JAQUAR & COMPANY PVT LTD.
Supply and fix round down lighter 9 watt complete with drivers, connectimg accessories and provision of fixing arrangement in false ceiling , complete all as specified and directed. Make:- Crompton Cat No. LCDE0-09-CDL Quartz or equivalent in BAJAJ/PHILIPS/WIPRO/HAVELLS/SYSKA LED/ M/s SURYA ROSHNI LIMITED/M/S JAQUAR & COMPANY PVT LTD.
Dismantling of unserviceable UG cable including of any size and keeping in safe custody for disposal all as directed.
Supply and lay cable or fixed to wall/floors XLPE insulated, PVC bedded, Galvanised steel strip or wire armoured, Electric power cable heavy duty with stranded alluminium conductors,1100 volt grade, 16 Sq mm, 4 Core all as specified and directed.
Supply and lay cable or fixed to wall/floors XLPE insulated,PVC bedded, Galvanised steel strip or wire armoured, Electric power cable heavy duty with stranded alluminium conductors,1100 volt grade, 25 Sq mm, 3.5 Core all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed.
Material and labour for laying of bricks locally available sub-class 'B' brick (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the directon of cable complete all as specified and directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
Material & labour GI tube light grade 40 mm for protection of UG cable including dismantling of old unsv pipe complete all as specified and directed.
M/S M P SHARMA
SURANA CORPORATION
Younus Khan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .